Site Plan Review Comments
All Site Plan Review Comments for Case # 18PR0151
Modify comments view for Case # 18PR0151

Go to Case Selection Form or Go to Project List

 
CASE NO: 18PR0151 STATUS: PENDING APPROVAL
PROJECT NAME: BERMUDA CROSSING APA - LAST INTERNET UPDATE: 02/23/18
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 10/26/17 11/16/17 ******** ********
ENVIR.ENGR.-: 01 01/29/18 02/19/18 ******** ********
FIRE DEPT.--: 01 01/29/18 02/19/18 COMPLETE 02/02/18 AWB 717-6167
MAPPING/GIS-: 01 01/29/18 02/19/18 COMPLETE 02/14/18 AMJ 768-7549
PLANNING----: 01 01/29/18 02/19/18 ******** ********
TRANSPORT.--: 01 01/29/18 02/19/18 COMPLETE 02/09/18 SJA 751-4461
UTIL.PLAN.--: 01 01/29/18 02/19/18 ******** ********
UTILITIES---: 01 01/29/18 02/19/18 ******** 11/22/17 A U
UTIL.R.O.W.-: 01 01/29/18 02/19/18 ******** ********
VDOT--------: 01 01/29/18 02/19/18 ******** ********
REVIEW DEPARTMENT : UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, (804) 748-1343
NAME OF PLAN : BERMUDA CROSSING APARTMENTS
ADDRESS : 12006 BERMUDA CROSSROADS LANE
SUBMISSION DATE : 10/26/17
PLAN DATED : 10/24/17
REVIEW DATE : 11/15/17
SITE PLAN NO. : 18PR0151
COMMENTS : 1ST REVIEW - NOT APPROVED
TABLE REVIEW : NO
ADD THE UTILITIES PROJECT NUMBER (15-0201) TO THE COVER SH
T AND ALL UTILITIES SHEETS AT A MINIMUM
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVISE THE FOLLOWING UTILITIES CONTACT INFORMATION: ANNE
URENDAA@CHESTERFIELD.GOV.3,
ON NOTE 4 OF THE PUBLIC UTILITIES NOTES, ADD 95 AS THE ELE
REQUIRED.OUR BELOW WHICH PRV'S WILL BE
ON THE UTILITY MATERIAL QUANTITIES, IDENTIFY WHICH ITEMS A
PUBLIC AND PRIVATE AND THE QUANTITIES OF
EACH. ADD 2" COPPER WATER SERVICE TO THE WATER QUANTITIES
SHOW THE LOCATION OF THE REQUIRED WATERLINE "JUMPER" ON TH
EXISTING WATERLINE. THE JUMPER MUST CONFORM TO DETAIL WAT
AND THE DETAIL MUST BE ADDED TO THE PLAN
LABEL THE COUNTY PROJECT NUMBER OF THE EXISTING WATERLINE
8-0064).
LABEL THE WATER AND SEWER LINES AS PUBLIC OR PRIVATE IN BO
*PLAN AND PROFILE VIEWS.
8. ADD EASEMENTS AROUND THE FIRE HYDRANT (10' X 10') AND F
EASEMENT TO THE PROPOSED WATER METER (10' WIDE). THE PRIV
THE EASEMENTS.HOULD BE LOCATED OUTSIDE OF
*
9. LABEL THE 2" COPPER WATER SERVICE AND SIZE OF THE PROPO
**WATER METER.
10. CALL OUT THE EXISTING WATER VALVE THAT WILL BE CLOSED
* TIE-IN OF THE NEW WATERLINE.
11. LABEL THE EXISTING WATER EASEMENT WITH TYPE, SIZE, DEE
BOOK AND PAGE NUMBER.
. IDENTIFY 8" X 6 TEES FOR FIRE HYDRANT ASSEMBLIES AS HYDR
MATERIAL QUANTITIES LIST ON THE COVER.N IN THE
*
ON THE WATERLINE PROFILES, LABEL THE SIZE AND MATERIAL OF
E WATERLINE AND THE STORM SEWERS
. IDENTIFY THE VERTICAL COORDINATE SYSTEM USED FOR THE SUR
Y. NOTE THAT THE COUNTY USES NVD29
ON THE WATER MAIN PROFILE, THERE IS INSUFFICIENT SEPARATIO
THE EXISTING STORM SEWER. THE WATER MAIN WILL NEED TO BE
WERED UNDER THE STORM SEWER.
CALCULATE THE REQUIRED LENGTH OF RESTRAINT FOR ALL HORIZON
L AND VERTICAL FITTINGS, VERTICAL TRANSITIONS,
AND DEAD-ENDS. THE CALCULATED LENGTHS OF RESTRAINT MUST B
RESTRAINT CALCULATIONS WITH THE NEXT SUBMITTAL.
*
17. ON THE WATER LATERAL PROFILE, DUCTILE IRON PIPE IS REQ
PIPE WHICH CROSSES THROUGH THE EXCAVATED AREA WHERE SEDIME
*BASIN ST2 WAS LOCATED.
18. ON THE SANITARY SEWER PROFILE, CHANGE THE LABEL OF THE
XISTING MANHOLE TO EX-16.
ALL PROPOSED MANHOLES WILL REQUIRE MANHOLE INSERTS. ADD A
REQUIRED FOR ALL MANHOLES AND THE APPROVED INSERT IS A PAR
GASKET, AND STRAP. ADDITIONALLY, THE PARSON'S INSERTS MUS
*E ADDED TO THE QUANTITIES LIST.
A SAMPLING MANHOLE IS UNNECESSARY FOR THIS SITE. REMOVE D
*IL MAN-17 FROM THE PLANS.
21. REMOVE THE NOTES DISCUSSING THE PROCEDURES FOR INSTALL
SEWER.CH LATERALS WHICH PERTAIN TO PUBLIC
*
22. REPLACE DETAIL MET-1 WITH MET-7 SINCE THE METER BEING
*TALLED IS 1½" IN SIZE.
23. REPLACE DETAIL MET-11 WITH DETAIL MET-12 SINCE THE WAT
SERVICE IS 2" IN SIZE.
WILL A LANDSCAPING PLAN BE FORTHCOMING? IF SO, PLEASE ENSU
THAT ALL PROPOSED WATER UTILITIES ARE
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
A SAMPLING MANHOLE IS UNNECESSARY FOR THIS SITE. REMOVE D
*IL MAN-17 FROM THE PLANS.
21. REMOVE THE NOTES DISCUSSING THE PROCEDURES FOR INSTALL
SEWER.CH LATERALS WHICH PERTAIN TO PUBLIC
*
22. REPLACE DETAIL MET-1 WITH MET-7 SINCE THE METER BEING
*TALLED IS 1½" IN SIZE.
23. REPLACE DETAIL MET-11 WITH DETAIL MET-12 SINCE THE WAT
SERVICE IS 2" IN SIZE.
WILL A LANDSCAPING PLAN BE FORTHCOMING? IF SO, PLEASE ENSU
THAT ALL PROPOSED WATER UTILITIES ARE SHOWN. THIS INCLUDE
WATER SERVICE LINES AND WATER METERS AS WELL AS SEWER
LATERALS.
STREET TREES MUST BE LOCATED AT LEAST 10' FROM SERVICE LIN
/WATER METERS AND LATERALS/CLEANOUTS ANDM AY NOT BE LOCATE
WITHIN PUBLIC EASEMENTS.
25. THE OWNER IS REQUIRED TO ENTER INTO A COUNTY UTILITIES
ONTRACT PRIOR TO THE START OF CONSTRUCTION. PRIOR TO THE P
PARTATION OF THE UTILITIES CONTRACT, UTIITIES MUST BE IN R
EIPT OF THE "ACCEPTED" BID PROPOSAL BETWEEN THE DEVELOPER
D THE COUNTY APPROVED UTILITIES CONTRACTOR AS WELL AS THE
OJECT'S
IST". PLEASE SEND THOSE TWO ITEMS TO THE ATTENION OF ANNE
ENDA (URENDAA@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE
BASED ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SI
PLAN IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATI
OR RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES CONTR
T MAY BE NECESSARY.
26. AFTER FINAL SITE PLAN APPROVAL, FOUR SETS TOTAL OF TH
PROVED PLANS MUST BE SENT DIRECTLY TO THE UTILITIES DEPART
NT FOR OUR USE DURING CONSTRUCITON INSPECTION. ONE ADDTION
ROLLED SET WILL BE REQUESTED AFTER THE PROJECT IS RELEASE
TO CONSTRUCITON TO BE USED FOR AS-BUILTS.
27. PLEASE SUBMIT 1 SET OF REVISED PLANS WITH THE NEXT
SUBMITTAL.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: BERMUDA CROSSING APARTMENTS
SITE PLAN NUMBER: 18PR0151
LATEST PLAN DATE: 10/24/17
DEPT. REC'D. DATE: 10/31/17
SUBMITTAL NUMBER: ONE (LAMSON)
REVIEW DATE: 11/02/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: BERMUDA CROSSING APARTMENTS
SITE PLAN NUMBER: 18PR0151
LATEST PLAN DATE: 01/16/18
DEPT. REC'D. DATE: 02/01/18
SUBMITTAL NUMBER: TWO (LAMSON)
REVIEW DATE: 02/09/18
RECOMMENDATION: APPROVED
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : BERMUDA CROSSING APARTMENTS
CASE NUMBER : 18PR0151
LATEST PLAN DATE : 10/24/2017
RECEIVED DATE : 11/1/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 11/15/17
ADDRESS : PENDING
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. INDICATE THE METHOD OF MAIL DELIVERY - INSIDE
BUILDING KIOSK; OR NEIGHBORHOOD DELIVERY COLLECTION
BOX UNIT (NDCBU). IF DELIVERY IS BY NDCBU, PLACE THE
LOCATION OF THE NDCBU KIOSK ON THE PLAN.
2. PLEASE PROVIDE A FLOORPLAN LAYOUT FOR THE APARTMENT
BUILDING.
3. FOR PURPOSES OF ADDRESSING APARTMENT UNITS: TOWNHOUSE
STYLE UNITS WITH FRONT DOORS FACING THE PARKING LOT WILL
RECEIVE INDIVIDUAL ADDRESSES. UNITS WITH ACCESS FROM A
COMMON BREEZEWAY WILL RECEIVE THE BUILDING ADDRESS
NUMBER WITH A UNIT NUMBER BEGINNING WITH 101 FOR THE
FIRST FLOOR, LEFT FRONT UNIT AND INCREASING IN THE
CLOCKWISE DIRECTION; SECOND FLOOR WILL BEGIN WITH 201
FOR THE FRONT LEFT UNIT, ETC. NO ALPHA-NUMERIC UNIT
NUMBERS WILL BE ASSIGNED.
4. STREET ADDRESS LOCATION IS NOT SHOWN. IT CAN BE
LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF A
MONUMENT SIGN. LOCATION AND MATERIAL USED MUST BE NOTED
ON THE SITE PLAN. IF YOU ARE USING A MONUMENT SIGN, A
DETAIL OF THE MONUMENT SIGN MUST BE ON THE SITE PLAN.
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : BERMUDA CROSSING APARTMENTS
CASE NUMBER : 18PR0151
LATEST PLAN DATE : 1/16/18
RECEIVED DATE : 2/1/18
SUBMITTAL NUMBER : 2
REVIEW DATE : 2/14/18
ADDRESS : 12006 BERMUDA CROSSROAD LN (WITH APT
NUMBERS INSIDE)
STATUS : APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: BERMUDA CROSSING APARTMENTS
SITE PLAN NUMBER: 18PR0151
ADDRESS: 12006 BERMUDA CROSSROAD LANE
LATEST PLAN DATE: 10/24/17
DEPT. REC'D. DATE: 10/31/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 11/13/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. ADD A NOTE TO THE UTILITY PLAN STATING:
"THE 4.5 INCH DISCHARGE OF THE FIRE HYDRANT SHALL FACE
IN THE DIRECTION INDICATED BY THE ARROW ON THE PLAN."
2. ADD AN ARROW TO THE FIRE HYDRANT INDICATING WHICH
DIRECTION IT SHALL FACE.
3. THE FOLLOWING NOTE SHALL BE ADDED TO THE GENERAL
NOTES ON PLANS:
"AN APPROVED KEY BOX SHALL BE PROVIDED FOR THE PROPOSED
BUILDING IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE,
SECTION 506.1 THE REQUIRED FORMS AND INSTALLATION
INSTRUCTIONS FOR THE KEY BOX CAN BE OBTAINED FROM
CHESTERFIELD FIRE AND EMS, FIRE AND LIFE SAFETY DIVISION,
AT 748-1426."
4. A NOTE ADDRESSING THE REQUIREMENTS BELOW SHALL BE
ADDED TO THE GENERAL NOTES ON THE SITE PLAN.
"DURING THE CONSTRUCTION OF ANY STRUCTURE OR BUILDING,
PERMANENT FIRE HYDRANTS SHALL BE INSTALLED, PRIOR TO THE
USE OF COMBUSTIBLE MATERIALS IN CONSTRUCTION BEING USED
ON ANY FLOOR ABOVE THE FIRST FLOOR OR GROUND FLOOR
LEVEL HYDRANTS SHALL BE FUNCTIONAL FOR FIRE FIGHTING
PURPOSES AND MAINTAINED ACCESSIBLE TO FIRE FIGHTING
APPARATUS AT ALL TIMES. AN APPROVED ALL-WEATHER ROAD
SURFACE SHALL BE PROVIDED FOR ACCESS TO THE FIRE HYDRANTS
DURING CONSTRUCTION." SEE CHESTERFIELD COUNTY CODE
SECTION 106.9
5. THE FOLLOWING SHALL BE ADDED TO THE GENERAL NOTES ON
PLANS FOR BUILDINGS EQUIPPED WITH AN AUTOMATIC FIRE
SPRINKLER SYSTEM AND/OR STANDPIPE SYSTEM: "APPROVAL OF
SITE PLAN DOES NOT INCLUDE THE DESIGN OF THE FIRE
SPRINKLER SYSTEM UNDERGROUND PIPING FROM BACKFLOW
PREVENTION DEVICE TO ONE FOOT ABOVE FINISH FLOOR LEVEL.
PRIOR TO INSTALLATION, SHOP DRAWINGS AND A SEPARATE
PERMIT APPLICATION AND SHALL BE SUBMITTED THROUGH THE
DEPARTMENT OF BUILDING INSPECTIONS FOR REVIEW AND
APPROVAL."
6. SHOW THE NODE MAP AND RESULTS TABLE FOR THE PROPOSED
OR EXISTING HYDRANTS ON SITE SHOWING THE MAXIMUM FIRE
FLOW CAN BE ACHIEVED. WHEN MULTIPLE FIRE HYDRANTS ARE
USED THE COMBINED FLOW MUST BE SIMULTANEOUS.
7. THE APPROXIMATE LOCATION OF ALL REQUIRED FIRE LANE
SIGNS AND CURB / STREET MARKING SHALL BE INDICATED ON
THE PLAN. FIRE LANES THAT ARE BETWEEN TWENTY AND
TWENTY-SIX FEET IN WIDTH SHALL BE POSTED AND MARKED ON
BOTH SIDES OF THE ROADWAY. FIRE LANES IN EXCESS OF
TWENTY-SIX FEET IN WIDTH UP TO THIRTY-TWO FEET IN WIDTH
SHALL BE POSTED AND MARKED ON ONE SIDE OF THE
ROADWAY. THE LOCATION OF AND METHOD OF MARKING FIRE
LANES SHALL BE CLEARLY INDICATED ON THE SUBMITTED SITE
PLAN. ALL FIRE LANE SIGNS SHALL BE DOUBLE FACED AND
INSTALLED PERPENDICULAR TO THE CURB.
8. ON THE UTILITY PLAN, SHOW THE GATE VALVE AND BOX AT THE
END OF THE UTILITY EASEMENT SERVING THE FIRE PROTECTION
UNDERGROUND WITH INTERIOR BACKFLOW PREVENTER.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: BERMUDA CROSSING APARTMENTS
SITE PLAN NUMBER: 18PR0151
ADDRESS: 12006 BERMUDA CROSSROAD LANE
LATEST PLAN DATE: 1/16/18
DEPT. REC'D. DATE: 2/1/18
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 2/2/18
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. PROVIDE THE DETAILS FOR THE AUTOMATIC SPRINKLER SYSTEM
RUN-IN AND STUB UP, INCLUDING ALL APPLICABLE NOTES. SEE:
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
FOR A COPY OF THE DETAILS

Modify comments view for case # 18PR0151