CASE NO: 18PR0128 STATUS: PENDING APPROVAL
PROJECT NAME: THE GLEN & COLONIAL - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: MULTI-FAMILY
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 01 10/19/17 11/01/17 ******** ********
ENVIR.ENGR.-: 01 10/19/17 11/01/17 ******** ********
FIRE DEPT.--: 01 10/19/17 11/01/17 COMPLETE 11/16/17 AWB 717-6167
MAPPING/GIS-: 01 10/19/17 11/01/17 COMPLETE 11/17/17 AMJ 768-7549
PLANNING----: 01 10/19/17 11/01/17 COMPLETE 11/01/17 L M 717-6836
TRANSPORT.--: 01 10/19/17 11/01/17 COMPLETE 11/21/17 SJA 751-4461
UTIL.PLAN.--: 01 10/19/17 11/01/17 ******** ********
UTILITIES---: 01 10/19/17 11/01/17 AMENDED* 10/30/17 A U
UTIL.R.O.W.-: 01 10/19/17 11/01/17 ******** ********
VDOT--------: 01 10/19/17 11/01/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, P.E./(804)748-1343
NAME OF PLAN : THE GLEN AND COLONIAL RIDGE AT COLONIA
HEIGHTS
ADDRESS : 2609 MANGOWOOD DRIVE
SUBMISSION DATE : 9/13/17
PLAN DATED : 9/8/17
REVIEW DATE : 10/2/17
PLANNING CASE NO.: 18PR0128
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
*
1. COUNTY PROJECT NUMBER 17-0197 SHALL BE PLACED ON THE
LOWER RIGHT-HAND CORNER OF EACH SHEET
. INDICATE WHICH VERTICAL DATUM WAS USED.
*
3. PROVIDE A MINIMUM OF ONE BENCHMARK ON THE SITE AND
UTILITY PLAN SHEETS.
*
4. FILL IN THE "PUBLIC" AND "PRIVATE" QUANTITIES ON THE
MATERIAL QUANTITIES TABLE. ADD 2" COPPER WATERLINE,
1½" METER SERVICE, 5/8" METER SERVICE, IRRIGATION SERVICE,
AND BACKFLOW PREVENTER TO WATER QUANTITIES.
*
5. UPDATE THE LEGEND SO THAT THE SYMBOLS MATCH WHAT IS
SHOWN ON THE PLAN SHEETS. SEVERAL ITEMS HAVE 2 DIFFERENT
SYMBOLS (EXISTING WATER METERS, SANITARY MANHOLES, WATER
VALVES). USE A SINGLE SYMBOL FOR EACH ITEM. ADD OTHER
SYMBOLS SHOWN ON THE PLANS BUT NOT IN THE LEGEND.
*
6. ON THE EXISTING CONDITIONS AND DEMOLITION PLAN SHEETS,
SHOW AND LABEL EXISTING WATERLINES, SEWER LINES, AND
UTILITY EASEMENTS. INCLUDE THE COUNTY PROJECT NUMBER OF
THE EXISTING UTILITIES (77-7091) AND DB/PG OF THE WATER
EASEMENTS ON THE 2 PARCELS.
ON SHEET C1.1, LABEL THE EXISTING 1" WATER METER AND
1½" SERVICE LINE.
ON SHEET C1.4, SHIFT THE SEWER EASEMENT SO THAT IT
ENCOMPASSES THE EXISTING SEWER LINE.
*
9. ON SHEET C1.4, LABEL THE EXISTING 1" WATER METER AND
1½" SERVICE LINE. ADD A NOTE THAT THE 1½" SERVICE LINE
NEEDS TO BE ABANDONED PER COUNTY SPECIFICATIONS PRIOR TO
ANY OTHER LAND DISTURBING ACTIVITIES.
*
10. ON SHEET C1.4, THE PORTION OF SANITARY SEWER BEING
ABANDONED NEEDS TO BE FILLED WITH FLOWABLE FILL. ADD NOTE
TO PLANS.
*
ON SHEET C1.4, SHOW THE LOCATION OF THE EXISTING SEWER
LATERAL THAT WILL BE DEMOLISHED.
*
13. ON THE SITE & UTILITY PLAN SHEETS, SHOW AND LABEL
EXISTING WATERLINES, SEWER LINES, AND UTILITY EASEMENTS.
IDENTIFY IF THE UTILITY LINES ARE PUBLIC OR PRIVATE.
*
14. ON SHEET C4.1, UTILITIES RECOMMENDS SERVICE LINES BE
SIZED ONE SIZE LARGER THAN THE SIZE OF THE WATER METER
(WM). IF EXISTING 1½" SERVICE LINE IS TO BE REPLACED WITH
NEW 2" SERVICE LINE, PLEASE NOTE ON PLANS. A NEW METER BOX
IS REQUIRED FOR THE LARGER METER. SHOW A NEW 10' WATER
EASEMENT FROM THE EXISTING WATER EASEMENT TO THE NEW METER
BOX.
*
15. ON SHEET C4.3, SHIFT THE TIE-IN LOCATION OF THE NEW
WATER SERVICE SO THAT IT IS 10 FEET FROM SEWER LATERAL.
*
16. ON SHEET C4.3, CHANGE LABEL OF WATER SERVICE TO
1" COPPER SERVICE LINE. SHOW A NEW 10' WATER EASEMENT FROM
THE EXISTING WATER EASEMENT TO THE NEW METER BOX.
*
17. ON SHEET C4.4, SHOW A NEW 16' WIDE SEWER EASEMENT
AROUND THE PROPOSED SEWER.
ON SHEET C4.4, SHOW AND LABEL THE NEW 2" COPPER WATER
SERVICE FROM THE WATERMAIN TO THE NEW 1½" WATER METER. A
NEW METER BOX IS REQUIRED FOR THE LARGER METER. SHOW A NE
10' WATER EASEMENT FROM THE EXISTING WATER EASEMENT TO THE
NEW METER BOX.
*
20. CONFIRM THAT THE SWIMMING POOL BACKWASH FILTER RATE CA
BE ACCOMMODATED IN THE DOWNSTREAM SANITARY SEWER. PROVIDE
CALCULATIONS WITH NEXT SUBMITTAL. NOTE THAT THE BACKWASH
CANNOT BE DISCHARGED TO THE STORM SEWER.
*
WILL THERE BE ANY OUTDOOR SHOWERS? IF SO, THEY WILL
NEED TO BE COVERED SO THAT RAINWATER DOES NOT ENTER THE
SANITARY SEWER THROUGH A FLOOR DRAIN.
*
22. ALL PROPOSED MANHOLES WILL REQUIRE MANHOLE INSERTS.
ADD A NOTE STATING THAT INSERTS ARE REQUIRED FOR ALL
MANHOLES AND THE APPROVED INSERT SHALL BE PARSON PMI3SE
WITH VALVE, GASKET, AND STRAP. ADDITIONALLY, THE INSERTS
MUST BE ADDED TO THE QUANTITIES LIST.
*
23. ON SHEET C4.6, DELETE THE DUPLICATE COPIES OF THE MET-
DETAILS.
IN THE STANDARD DETAIL DES-2, NOTE 4, ADD 95 FEET AS
THE CONTOUR BELOW WHICH PRVS WILL BE REQUIRED.
*
25. ON SHEET C6.0, ADD THE COUNTY PROJECT NUMBER OF THE
EXISTING SEWER TO THE SANITARY SEWER PROFILE. CHANGE THE
EX MH2 TO A PROPOSED MANHOLE.
*
26. ADD A NOTE TO THE SANITARY SEWER PROFILE INDICATING AL
MH RIMS ALONG THE UNDEVELOPED SEGMENT MUST BE INSTALLED AT
12" ABOVE GRADE. THE PROFILE SHOULD SHOW THE MANHOLE RIM
ELEVATIONS GRAPHICALLY.
*
27. ADD A NOTE STATING THAT ALL SALVAGEABLE PUBLIC WATER
APPURTENANCES ARE TO BE RETURNED TO THE CHESTERFIELD
DEPARTMENT OF UTILITIES AT THE DISCRETION OF THE UTILITIES
INSPECTOR.
*
28. IF ANY CHANGES TO THE PROPOSED UTILITIES ARE MADE BASE
ON THESE COMMENTS, PLEASE UPDATE THE MATERIAL QUANTITIES O
THE COVER SHEET ACCORDINGLY.
*
29. BASED ON NOTE 23 OF THE GENERAL DEVELOPMENT NOTES, AN
IRRIGATION SYSTEM IS PROPOSED. SHOW THE IRRITATION METER
AND BACKFLOW PREVENTION DEVICE ON THE PLANS. THE METER
SHOULD BE SHOWN IN A 10' WATER EASEMENT. SUBMIT A METER
SIZING FORM FOR THE PROPOSED IRRIGATION WATER METER. ADD
ALL METER SIZING FORMS TO THE PLANS.
*
30. ON SHEET L1.1, SHOW AND LABEL ALL PROPOSED WATER
SERVICES, METER BOXES, AND WATER EASEMENTS. NO TREES CAN
BE LOCATED WITHIN THE UTILITY EASEMENTS. METER BOXES
SHOULD HAVE A MINIMUM OF 24 INCHES OF CLEARANCE FROM
BUSHES.
BE ADVISED THAT FOR ALL ONSITE PUBLIC WATERLINES AND/OR
SEWER LINES THAT ARE CONTAINED WITHIN EASEMENTS, THE
EASEMENTS MUST BE DEDICATED PRIOR TO ACCEPTANCE OF
UTILITIES INTO SYSTEM.
PRIOR TO RELEASE OF THE PROJECT TO THE CONSTRUCTION
SECTION, A COPY OF THE ENVIRONMENTAL ENGINEERING APPROVAL
LETTER AND/OR ALL OTHER APPLICABLE LOCAL STATE AND FEDERAL
AGENCIES' APPROVAL LETTERS MUST BE RECEIVED BY THE
UTILITIES DEPARTMENT.
*
33. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY-APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THESE
DOCUMENTS TO THE ATTENTION OF ANNE URENDA
(URENDAA@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
*
34. PROVIDE ONE SET OF PLANS WITH REVISIONS WITH NEXT
SUBMISSION.
*
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, P.E./(804)748-1343
NAME OF PLAN : THE GLEN AND COLONIAL RIDGE AT COLONIA
HEIGHTS
ADDRESS : 2609 MANGOWOOD DRIVE
SUBMISSION DATE : 10/19/17
PLAN DATED : 10/17/17
REVIEW DATE : 10/27/17
PLANNING CASE NO.: 18PR0128
COMMENTS : 2ND REVIEW-NOT APPROVED
TABLE REVIEW : YES
I COULD NOT FIND THE BENCHMARK ON THE SITE AND UTILITY
PLAN SHEETS. PLEASE MAKE THE BENCHMARK SYMBOL MORE VISIBLE
*
2. ON THE MATERIAL QUANTITIES TABLE, ADD THE LENGTH OF NEW
2" COPPER WATERLINE AND THE 1 1/2" WATER METER WHICH WILL
SERVE THE YMCA BUILDING EXPANSION. ADD 3 MH INSERTS TO THE
SEWER QUANTITIES TABLE.
ON SHEET C1.1, DARKEN AND LABEL THE EXISTING 1½" SERVICE
LINE SERVING THE YMCA. THE EXISTING WATER SERVICE BETWEEN
THE WATERLINE AND THE METER NEEDS TO BE ABANDONED IN PLACE
PER COUNTY SPECIFICATIONS PRIOR TO ANY OTHER LAND
DISTURBING ACTIVITIES. STATE THAT THE EXISTING 1" WATER
METER IS TO BE REMOVED. THE EXISTING 1½" WATERLINE
BETWEEN THE NEW METER METER AND THE BUILDING CAN EITHER BE
ABANDONED OR REPLACED WITH THE NEW 2" COPPER SERVICE.
*
4. ON SHEET C1.4, CHANGE THE TEXT FOR THE EXISTING 1" WATE
METER TO STATE THAT IT WILL BE REMOVED, NOT RELOCATED. ON
THE LABEL POINTING TO THE 1 ½" SERVICE LINE, DELETE
"& 1" WM".
ON SHEET C4.1, SHOW A NEW 2" SERVICE LINE TO THE YMCA
BUILDING NEXT TO THE EXISTING 1 ½" SERVICE LINE BETWEEN TH
WATERLINE AND THE NEW 1½" METER. THE NEW SERVICE LINE
NEEDS TO BE A MINIMUM OF 18" FROM EXISTING 1½" SERVICE
LINE. SHOW AND LABEL A NEW 1½" METER. MOVE THE 10' WATER
EASEMENT FROM ITS CURRENT LOCATION SO THAT IT IS CENTERED
OVER THE NEW 2" SERVICE LINE. LABEL THE PROPOSED 10'
WATERLINE EASEMENT. THE WORDS "TO HERE BY DEDICATED TO THE
CHESTERFIELD COUNTY" ARE NOT REQUIRED ON THE PROPOSED
WATERLINE AND SEWER EASEMENT LABELS.
ON SHEET C4.4, THE SANITARY LATERAL ENTERING MH1 NEEDS
TO BE 6" FROM THE CLEANOUT TO THE MANHOLE.
THE REQUEST FROM THE FIRST SUBMITTAL TO REPLACE SANITARY
MANHOLE EX9 WAS BASED ON THE SMALL SEPARATION DISTANCE
BETWEEN THE OPENING IN THE MANHOLE LEFT BY THE EXISTING
MANHOLE AND THE NEW OPENING FOR THE RELOCATED SEWER. ADD
NOTE IN THE PLAN AND PROFILE VIEWS STATING THAT THE
CONTRACTOR MUST FILL THE ABANDONED HOLE WITH A CONCRETE MI
TO ENSURE A WATERTIGHT SEAL IN THE MANHOLE WALL. IF THE
KOR-N-SEAL ASSEMBLY CANNOT BE PROPERLY INSTALLED IN THE NE
CORED OPENING DUE TO PROXIMITY TO EXISTING OPENING, MANHOL
REPLACEMENT MAY BE NECESSARY.
*
8. PLEASE PROVIDE UPDATED 8.5" X 11" SIGNED METER SIZING
FORMS. YOU CAN EMAIL THEM TO ME AT
URENDAA@CHESTERFIELD.GOV.
AS A CONDITION OF A TABLE REVIEW, REVISED PLAN SHEETS
AND A COMMENT RESPONSE LETTER MUST BE SUBMITTED IN PDF
FORMAT TO URENDAA@CHESTERFIELD.GOV BY THE FRIDAY PRIOR TO
THE TABLE REVIEW DATE.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: GLEN & COLONIAL RIDGE
SITE PLAN NUMBER: 18PR0128
LATEST PLAN DATE: 09/08/17
DEPT. REC'D. DATE: 09/15/17
SUBMITTAL NUMBER: ONE (MIGNARDI)
REVIEW DATE: 09/22/17
RECOMMENDATION: APPROVED
.
LABEL JEFFERSON DAVIS HWY AS A MAJOR ARTERIAL PER COUNTY'S
THOROUGHFARE PLAN.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: GLEN & COLONIAL RIDGE
SITE PLAN NUMBER: 18PR0128
LATEST PLAN DATE: 10/17/17
DEPT. REC'D. DATE: 10/23/17
SUBMITTAL NUMBER: TWO (MIGNARDI)
REVIEW DATE: 10/26/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: GLEN & COLONIAL RIDGE
SITE PLAN NUMBER: 18PR0128
LATEST PLAN DATE: 11/13/17
DEPT. REC'D. DATE: 11/14/17
SUBMITTAL NUMBER: THREE (MIGNARDI)
REVIEW DATE: 11/21/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: LUIGI MIGNARDI / 717-6836
PLAN NAME: THE GLEN & COLONIAL RIDGE
PLAN NUMBER: 18PR0128
ORIGINAL PLAN DATE: 09/08/17
REVIEW DATE: 10/03/17
LATEST SUBMISSION DATE:
SUBMITTAL NUMBER: 1
STATUS: CORRECTIONS REQUIRED
TABLE REVIEW: NO
.
01. PER THE MOU INCLUDE THE THE NON-RESIDENT PARKING
OUTSIDE THE FENCED AREA. SHOW SIDEWALKS AND HOW
GUESTS
02. PER THE MOU SHOW THE FENCING ON THE PLAN ALONG
WITH DETAILS
03. ON SHEET C4.4 THERE IS A PROPOSED ACCESSIBLE PARKING
ON THE SOUTHERN PORTION OF THE PARKING LOT THAT DOES NOT G
TO ACCESSIBLE UNIT, LOOK AT MOVING THE SPACE TO THE NORTH
SIDE OF THE PARKING LOT WITH THE OTHER TWO ACCESSIBLE SPAC
04. CALL OUT ON PLANS QUANTITIES AND LOCATIONS OF THE PROP
AMENITIES SHOWN ON SHEET L1.5, THIS INCLUDES PICNIC TABLES
BENCHES, TRASH RECEPTACLES AND GRILLING STATIONS
05. PROVIDE A DETAIL OF THE CONCRETE SLAB AND PICNIC
PAVILION FOUNDATION FOOTERS
06. PROVIDE A DETAIL AND MATERIAL TO BE USED FOR THE
PROPOSED CONCRETE PATIO BY THE YMCA BUILDING ON
SHEET C4.1
07. ON SHEET L1.3 SHOWS NEW FOUNDATION PLANTINGS
FOR EXISTING BUILDINGS, PROVIDE ACTUAL QUANTITIES OF
PROPOSED PLANTS SO CONTRACTOR/OWNER CAN ACCURATELY
BUDGET FOR THE PROJECT
08. PROVIDE STANDARD COUNTY LANDSCAPE NOTES ON DETAILED
LANDSCAPE PLAN.
09. PER SEC. 19.1-317 A, B, PROVIDE 2 COPIES OF
RENDERINGS/ELEVATIONS OF THE BUILDINGS WITH ALL BUILDING
MATERIALS AND COLORS IDENTIFIED, LOCATIONS OF JUNCTION AND
ACCESS BOXES SHOWN, AND HOW ALL MECHANICAL
EQUIPMENT IS SCREENED WHETHER IT IS MOUNTED ON THE ROOF
OR ON THE GROUND.
10. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER 18PR0128
IN THE LOWER RIGHT CORNER OF EACH SHEET.
11. PUT NOTE ON PLANS, "ALL PROPOSED UTILITIES ARE TO BE
INSTALLED UNDERGROUND INCLUDING ELECTRIC, TELEPHONE AND
CATV."
12. PUT NOTE ON PLANS, "ANY SIGN IN EXCESS OF EIGHT (8)
SQUARE FEET REQUIRES A PERMIT. PERMIT MUST BE OBTAINED
THROUGH BUILDING INSPECTIONS DEPARTMENT." IF A SIGN IS
SHOWN ON THE SITE PLAN, NOTE ON PLAN "SIGNAGE
CONTINGENT UPON APPROVAL THROUGH SIGN PERMIT REVIEW
PROCESS."
13.THE FIRST SUBMITTAL SHALL INCLUDE A PLAN DATE (MONTH, D
& YEAR), AND EACH REVISED SET OF PLANS SHALL SHOW A REVISI
DATE.
14. AS DISCUSSED IN THE PRELIMINARY MEETING LOOK AT ADDING
A MORE FORMAL LANDSCAPE AND BENCHES AND OR PAVILION
IN THE LAWN AREA SOUTH OF THE CLUBHOUSE TO HELP DEFINE THE
ENTRANCEWAY.
----------------------------------------------------------
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: LUIGI MIGNARDI / 717-6836
PLAN NAME: THE GLEN & COLONIAL RIDGE
PLAN NUMBER: 18PR0128
ORIGINAL PLAN DATE: 09/08/17
REVIEW DATE: 11/01/17
LATEST SUBMISSION DATE: 10/17/17
SUBMITTAL NUMBER: 2
STATUS: SUBSTATIAL APPROVAL
TABLE REVIEW: YES
.
01. THE FENCING IS STILL NOT CLEAR ON THE PLANS, IT STILL
LOOKS LIKE THERE ARE GAPS IN AREAS. PLEASE ADJUST SO
IT MEETS THE INTENT OF THE MOU
02. CALL OUT WHERE GRILLING STATIONS WILL BE, IT'S HARD TO
DECIPHER WHERE THEY ARE ON THE PLAN.
03. THERE ARE FEW AMENITIES ON THE NORTH PART
OF THE SITE, WILL ANY BENCHES, GRILLING STATIONS OR
PLAY AREAS BE ADDED TO THIS LOCATION?
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : THE GLEN AND COLONIAL RIDGE
CASE NUMBER : 18PR0128
LATEST PLAN DATE : 9/8/17
RECEIVED DATE : 9/15/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 10/2/17
ADDRESS : 2609 MANGOWOOD DR/2717 MARTINGALE RD
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY ON SHEET C0.1.
2. ADDRESS SIGN FOR THE CLUBHOUSE IS NOT SHOWN. IT CAN
BE LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF
A MONUMENT SIGN. LOCATION AND MATERIAL USED MUST BE
NOTED ON THE SITE PLAN. IF YOU ARE USING A MONUMENT
SIGN, A DETAIL OF THE MONUMENT SIGN MUST BE ON THE
SITE PLAN.
3. THE CLUBHOUSE WILL KEEP THE EXISTING ADDRESS OF 2609
MANGOWOOD DR. THE PROPOSED MAINTENANCE BUILDING WILL BE
2713 MARTINGALE RD.
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : THE GLEN AND COLONIAL RIDGE
CASE NUMBER : 18PR0128
LATEST PLAN DATE : 10/17/17
RECEIVED DATE : 10/25/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 11/1/17
ADDRESS : 2609 MANGOWOOD DR/2717 MARTINGALE RD
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY ON SHEET C0.1.
2. ADDRESS SIGN FOR THE CLUBHOUSE IS NOT SHOWN. IT CAN
BE LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF
A MONUMENT SIGN. LOCATION AND MATERIAL USED MUST BE
NOTED ON THE SITE PLAN. IF YOU ARE USING A MONUMENT
SIGN, A DETAIL OF THE MONUMENT SIGN MUST BE ON THE
SITE PLAN.
3. THE ABOVE COMMENTS ARE APPEARING AGAIN BECAUSE THEY
HAVE NOT YET BEEN CORRECTED.
4. THE CLUBHOUSE WILL KEEP THE EXISTING ADDRESS OF 2609
MANGOWOOD DR. THE PROPOSED MAINTENANCE BUILDING WILL BE
2713 MARTINGALE RD.
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON(N)768-7549
PROJECT NAME : THE GLEN AND COLONIAL RIDGE
CASE NUMBER : 18PR0128
LATEST PLAN DATE : 11/13/17
RECEIVED DATE : 11/16/17
SUBMITTAL NUMBER : 3
REVIEW DATE : 11/17/17
ADDRESS : 2609 MANGOWOOD DR/2717 MARTINGALE RD
STATUS : APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: THE GLEN & COLONIAL RIDGE
SITE PLAN NUMBER: 18PR0128
ADDRESS: 2609 MANGOWOOD DRIVE
LATEST PLAN DATE: 9/8/17
DEPT. REC'D. DATE: 9/19/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 9/27/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. A FIRE FLOW ESTIMATE FORM NEEDS TO BE COMPLETED
FOR THE YMCA EXPANSION BUILDING AND THE PROPOSED
CLUBHOUSE.
2. PROVIDE COMPUTER GENERATED WATER FLOW TEST DATA,
PROVIDED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT, VERIFYING THE REQUIRED WATER FLOW FOR FIRE
PROTECTION IS AVAILABLE AT THE SITE. THE WATERFLOW TEST
RESULTS AND GRAPH SHALL BE SHOWN ON THE SUBMITTED PLAN.
THE MINIMUM REQUIRED FIRE FLOW FOR ALL BUILDINGS, WITH
THE EXCEPTION OF ONE AND TWO-FAMILY DWELLINGS, IS 1500
GPM (SPRINKLER PROTECTED OR NON-SPRINKLER PROTECTED) IN
ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (2012) -
SECTION B105.2 AND TABLE B105.1.
3. LABEL THE FIRE HYDRANTS ON THE UTILITY PLAN.
4. INSURE THERE IS A HYDRANT WITHIN 250 FEET OF THE PROPOS
CLUBHOUSE.
5. PROVIDE THE GATE DETAIL FOR THE GATE SECURING THE FIRE
APPARATUS ACCESS ROAD. THE DETAILS SHALL COMPLY WITH
THE 2012 INTERNATIONAL FIRE CODE, APPENDIX D,
SECTION D103.5
6. A MINIMUM OF 20 FEET IS REQUIRED FOR FIRE DEPARTMENT
APPARATUS ACCESS ROADS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: THE GLEN & COLONIAL RIDGE
SITE PLAN NUMBER: 18PR0128
ADDRESS: 2609 MANGOWOOD DRIVE
LATEST PLAN DATE: 10/17/17
DEPT. REC'D. DATE: 10/31/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 10/31/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: THE GLEN & COLONIAL RIDGE
SITE PLAN NUMBER: 18PR0128
ADDRESS: 2609 MANGOWOOD DRIVE
LATEST PLAN DATE: 11/13/17
DEPT. REC'D. DATE: 11/16/17
SUBMITTAL NUMBER: 3RD REVIEW
REVIEW DATE: 11/16/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.

Modify comments view for case # 18PR0128



Go to Case Selection Form or Go to Project List