Thanksgiving Holiday Closings... MORE

Hover here for Site Tools
Site Plan Review Comments
All Site Plan Review Comments for Case # 18PR0117
Modify comments view for Case # 18PR0117

Go to Case Selection Form or Go to Project List

 
CASE NO: 18PR0117 STATUS: PENDING APPROVAL
PROJECT NAME: MAG GRN CHARLESTON C - LAST INTERNET UPDATE: 11/21/17
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 08/03/17 08/24/17 ******** ********
ENVIR.ENGR.-: 01 10/31/17 11/22/17 ******** ********
FIRE DEPT.--: 01 10/31/17 11/22/17 COMPLETE 11/02/17 AWB 717-6167
MAPPING/GIS-: 01 10/31/17 11/22/17 COMPLETE 11/14/17 AMJ 768-7549
PLANNING----: 01 10/31/17 11/22/17 ******** ********
TRANSPORT.--: 01 10/31/17 11/22/17 COMPLETE 11/02/17 SJA 751-4461
UTIL.PLAN.--: 01 10/31/17 11/22/17 ******** ********
UTILITIES---: 01 10/31/17 11/22/17 ******** 08/30/17 A U
UTIL.R.O.W.-: 01 10/31/17 11/22/17 ******** ********
VDOT--------: 01 10/31/17 11/22/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, P.E./(804)748-1343
NAME OF PLAN : MAGNOLIA GREEN CHARLESTON CLUB AMENITY
ADDRESS : TWIN FALLS LANE AND TWIN FALLS COURT
SUBMISSION DATE : 8/3/17
PLAN DATED : 7/20/17
REVIEW DATE : 8/18/17
PLANNING CASE NO.: 18PR0117
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
COUNTY PROJECT NUMBER 17-0155 SHALL BE PLACED ON THE
LOWER RIGHT-HAND CORNER OF EACH SHEET.
REVISE THE UTILITIES CONTACT INFORMATION TO
ANNE URENDA, P.E., 804-748-1343,
URENDAA@CHESTERFIELD.GOV (SHEETS C1.0 AND C3.0).
*
3. ADD "PRIVATE" TO THE APPROXIMATE WATER QUANTITIES TABLE
*
4. ADD A PRV TO THE CUSTOMER SIDE OF WATERLINE SERVICE
SINCE THE ELEVATION IS BELOW 270.
*
5. LABEL THE 2" WATER SERVICE AS PRIVATE.
PROVIDE AN EASEMENT AROUND THE WATER METERS THAT EXTENDS
APPROXIMATELY 5 FEET IN ALL DIRECTIONS AROUND THE METERS.
THE BACKFLOW PREVENTER MUST REMAIN OUTSIDE OF THE EASEMENT
SHOW A BENCHMARK ON THE LAYOUT AND UTILITY PLAN SHEET.
*
8. ON THE UTILITY NOTES ON SHEET C3.0, NOTE 10 CONTRADICTS
WITH WHAT IS SHOWN ON THE PLAN.
*
9. CONFIRM THAT THE SWIMMING POOL BACKWASH FILTER RATE CAN
BE ACCOMMODATED IN THE DOWNSTREAM SANITARY SEWER. PROVIDE
CALCULATIONS WITH NEXT SUBMITTAL. NOTE THAT THE BACKWASH
CANNOT BE DISCHARGED TO THE STORM SEWER.
WILL THERE BE ANY OUTDOOR SHOWERS? IF SO, THEY WILL
NEED TO BE COVERED SO THAT RAINWATER DOES NOT ENTER THE
SANITARY SEWER THROUGH A FLOOR DRAIN.
LABEL THE SEWER AS PRIVATE ON THE PROFILE UPSTREAM OF
THE PROPERTY LINE. NOTE THE PUBLIC PORTION OF THE SEWER
LATERAL ENDS AT THE PROPERTY LINE.
*
12. THE COUNTY DETAILS SHOWN ON C8.3 ARE NOT APPLICABLE TO
THIS PROJECT AND CAN BE REMOVED.
*
13. ON SHEET C8.3, THE CHESTERFIELD WATER AND SEWER NOTES
AND UTILITY GENERAL NOTES ARE NOT APPLICABLE TO THIS
PROJECT OR ARE ALREADY INCLUDED IN THE UTILITY NOTES ON
SHEET C3.0. THE EXCEPTIONS ARE NOTE 19 OF THE WATER AND
SEWER NOTES AND NOTE 2 OF THE UTILITY GENERAL NOTES. THES
CAN BE MOVED TO THE UTILITY NOTES ON SHEET C3.0.
*
14. IF ANY CHANGES TO THE PROPOSED UTILITIES ARE MADE BASE
ON THESE COMMENTS, PLEASE UPDATE THE MATERIAL QUANTITIES O
THE COVER SHEET ACCORDINGLY.
*
15. SUBMIT AN 8½"X11" METER SIZING FORM WITH THE NEXT
SUBMITTAL. FORM SHOULD INCLUDE A SIGNATURE.
WILL A LANDSCAPE PLAN BE FORTHCOMING? IF SO, ENSURE
THAT ALL PROPOSED WATER UTILITIES ARE SHOWN. THIS INCLUDE
WATER SERVICE LINES AND WATERMAINS AS WELL AS SEWER
LATERALS. TREES MUST BE LOCATED AT LEAST 8 FEET FROM
SERVICE LINES/WATERMAINS AND LATERALS/CLEANOUTS AND MAY NO
BE LOCATED WITHIN PUBLIC EASEMENTS.
BE ADVISED THAT FOR ALL ONSITE PUBLIC WATERLINES AND/OR
SEWER LINES THAT ARE CONTAINED WITHIN EASEMENTS OR PROPOSE
RIGHTS-OF-WAY, THE EASEMENTS OR RIGHTS-OF-WAY MUST
BE DEDICATED PRIOR TO ACCEPTANCE OF UTILITIES INTO SYSTEM.
A COUNTY UTILITIES CONTRACT WILL NOT BE REQUIRED FOR
THIS PROJECT; HOWEVER, A BID PROPOSAL FOR THE UTILITY WORK
MUST BE SUBMITTED TO UTILITIES BY THE CONTRACTOR PRIOR TO
THE PROJECT BEING RELEASED FOR CONSTRUCTION.
PLEASE SUBMIT ONE SET OF REVISED PLANS WITH THE NEXT
SUBMITTAL.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: MAG GREEN CHARLESTON CLUB AMENTITY
SITE PLAN NUMBER: 18PR0117
LATEST PLAN DATE: 07/20/17
DEPT. REC'D. DATE: 08/08/17
SUBMITTAL NUMBER: ONE (LAMSON)
REVIEW DATE: 08/09/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: MAG GREEN CHARLESTON CLUB AMENTITY
SITE PLAN NUMBER: 18PR0117
LATEST PLAN DATE: 10/25/17
DEPT. REC'D. DATE: 11/01/17
SUBMITTAL NUMBER: TWO (LAMSON)
REVIEW DATE: 11/02/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON (N) 768-7549
PROJECT NAME : MAGNOLIA GREEN- CHARLESTON CLUB AMENITY
CASE NUMBER : 18PR0117
LATEST PLAN DATE : 7/20/17
RECEIVED DATE : 8/7/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 8/7/17
ADDRESS : PENDING
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. THIS SITE CANNOT BE APPROVED UNTIL ANOTHER SECTION OF
SUBDIVISION IS RECORDED TO ESTABLISH ROAD FRONTAGE.
.
2. STREET ADDRESS LOCATION IS NOT SHOWN. IT CAN BE
LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF A
MONUMENT SIGN. IT IS NOT CLEAR IF THE ADDRESS WILL BE
INCLUDED ON THE SIGN SHOWN IN THE ENTRANCE MEDIAN.
.
3. IF THE ADDRESS IS TO BE ON THE BUILDING, YOU MUST
SHOW WHERE IT WILL BE LOCATED ON THE BUILDING AND WHAT
IT WILL BE MADE OF. IF THE ADDRESS IS TO BE ON A PYLON
SIGN, YOU MUST SHOW WHERE IT WILL BE LOCATED ON THE
PROPERTY AND WHAT IT WILL BE MADE OF.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON (N) 768-7549
PROJECT NAME : MAGNOLIA GREEN- CHARLESTON CLUB AMENITY
CASE NUMBER : 18PR0117
LATEST PLAN DATE : 10/25/17
RECEIVED DATE : 10/27/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 11/14/17
ADDRESS : 17700 TWIN FALLS LANE
STATUS : SUBSTANTIALLY APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. THIS SITE CANNOT BE APPROVED UNTIL PINE VALLEY SECTION
2 IS RECORDED TO PROVIDE DEDICATED ROAD FRONTAGE. I HAVE
SUBSTANTIALLY APPROVED PENDING SUBDIVISION RECORDATION.
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: MAG GRN CHARLESTON CLB AMENITY
SITE PLAN NUMBER: 18PR0117
ADDRESS: 6700 OTTERDALE ROAD
LATEST PLAN DATE: 7/20/17
DEPT. REC'D. DATE: 8/8/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 8/10/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. PROVIDE COMPUTER GENERATED WATER FLOW TEST DATA,
PROVIDED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT, VERIFYING THE REQUIRED WATER FLOW FOR FIRE
PROTECTION IS AVAILABLE AT THE SITE. THE WATERFLOW TEST
RESULTS AND GRAPH SHALL BE SHOWN ON THE SUBMITTED PLAN.
THE MINIMUM REQUIRED FIRE FLOW FOR ALL BUILDINGS, WITH
THE EXCEPTION OF ONE AND TWO-FAMILY DWELLINGS, IS 1500
GPM (SPRINKLER PROTECTED OR NON-SPRINKLER PROTECTED) IN
ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (2012) -
SECTION B105.2 AND TABLE B105.1.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: MAG GRN CHARLESTON CLB AMENITY
SITE PLAN NUMBER: 18PR0117
ADDRESS: 6700 OTTERDALE ROAD
LATEST PLAN DATE: 10/25/17
DEPT. REC'D. DATE: 11/2/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 11/2/17/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.

Modify comments view for case # 18PR0117



Go to Case Selection Form or Go to Project List