CASE NO: 18PR0115 STATUS: PENDING APPROVAL
PROJECT NAME: MIDLOTHIAN RETAIL - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 08/03/17 08/24/17 ******** ********
ENVIR.ENGR.-: 01 10/30/17 11/21/17 ******** ********
FIRE DEPT.--: 01 10/30/17 11/21/17 COMPLETE 11/02/17 AWB 717-6167
MAPPING/GIS-: 01 10/30/17 11/21/17 COMPLETE 11/16/17 AMJ 768-7549
PLANNING----: 01 10/30/17 11/21/17 ******** 08/15/17 WST 768-7566
TRANSPORT.--: 01 10/30/17 11/21/17 COMPLETE 11/02/17 SJA 751-4461
UTIL.PLAN.--: 01 10/30/17 11/21/17 ******** ********
UTILITIES---: 01 10/30/17 11/21/17 AMENDED* 11/09/17 M L 748-1338
UTIL.R.O.W.-: 01 10/30/17 11/21/17 ******** ********
VDOT--------: 01 10/30/17 11/21/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E./748-1338
NAME OF PLAN : WHITTEN SERVICE BUILDING
ADDRESS : 622 JOHNSTON WILLIS DR
SUBMISSION DATE : 8/3/17
PLAN DATED : 7/6/17
REVIEW DATE : 8/10/17
SITE PLAN NO. : 18PR0115
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. UTILITIES PROJECT NUMBER 17-0151 SHALL BE PLACED ON THE
OWER RIGHT HAND CORNER OF EACH SHEET.
2. PLEASE PUT UTILITIES CONTACT MIKE LARSON, P.E. 748-1338
*ARSONM@CHESTERFIELD.GOV ON THE COVER SHEET.
3. IN NOTE 2 ON THE COVER SHEET, CHANGE 20% TO 2%.
*
4. IN NOTE 4 ON THE COVER SHEET, THE ELEVATION CONTOUR FOR
*IVATE PRVS IN THIS PRESSURE ZONE IS 301.
5. ON SHEET D-3, USE THE VDOT PAVEMENT REPAIR DETAIL INSTE
*OF PAV-2.
6. INCLUDE MANHOLE INSERTS FOR EACH MANHOLE, PRIVATE AND P
LIC ON THE MATERIALS LIST.
7. LABEL THE EXISTING WATER LINE WHERE THE CONNECTION WILL
E MADE AS 8" PVC, PROJECT 90-0247.
8. WE RECOMMEND UPSIZING THE SERVICE LINE TO EACH METER BY
*E NOMINAL SIZE, I.E. FROM 1" TO 1-1/2".
9. THE EASEMENT LINE SHOULD CROSS AT THE 6" GATE VALVE BET
*N PRIVATE AND PUBLIC WATER LINE.
10. SHOW THE EXISTING PHONE AND POWER ON JOHNSTON WILLIS D
*E ON THE PLAN VIEW.
11. SHOW THE EXTENT OF PAVEMENT REPAIR ON JOHNSTON WILLIS
*VE.
12. LABEL MH-1 AS A DOGHOUSE MANHOLE.
13. PUT A NOTE NEAR EX MH 3 AND EX MH 4 THAT THE INVERTS H
* BEEN FIELD LOCATED.
14. LABEL THE PROJECT NUMBER, SIZE, AND MATERIAL OF THE
EXISTING PIPES AT THE WATER AND SEWER CONNECTIONS ON THE P
(ILES.
15. LABEL THE STATIONING ON THE SANITARY PROFILE.
*
16. AT MH-2, THE INVERT SHOULD BE AT A 0.1' DROP FOR MANHO
* LESS THAN 12 FEET DEEP.
17. THE WORD "PRIVATE" IS MISSPELLED BETWEEN MH 2 AND 3.
*
18. THE SEWER BETWEEN MH 4-5 SHOULD BE LABELED PRIVATE, NO
*UBLIC.
19. ON THE WATER LINE, DRAW A DEMARCATION POINT AT THE
VALVE TO THE FIRE SERVICE BETWEEN PUBLIC AND PRIVATE WATER
LINE.
20. IT IS SUGGESTED THAT THE VERTICAL BENDS LOWERING THE P
*ATE FIRE LINE BE RESTRAINED.
21. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY UTI
TIES CONTRACT PRIOR TO THE START OF CONSTRUCTION. PRIOR T
THE PREPARATION OF THE UTILITIES CONTRACT, UTILITIES MUST
IN RECEIPT OF THE "ACCEPTED" BID PROPOSAL BETWEEN THE DEV
OPER AND THE COUNTY APPROVED UTILITIES CONTRACTOR AS WELL
THE PROJECT'S INFORMATIONAL SHEET FOUND ON THE "DEVELOPER
CHECKLIST". PLEASE SEND THOSE TWO
ITEMS TO THE ATTENTION OF MIKE LARSON (LARSONM@CHESTERFIE
.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
ECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL SHA
BE REVISED ACCORDINGLY AND A REVISED UTILITIES CONTRACT M
BE NECESSARY.
22. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF T
APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FOR O
USE DURING CONSTRUCTION INSPECTION. THIS IS IN ADDITION
THE ONE APPROVED SET FROM PLANNING (4 TOTAL SETS).
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
THIS WAS ENTERED UNDER THE WRONG CASE NO. SHOULD BE 18PR01
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RANDY PHELPS / 804-796-7126
NAME OF PLAN : MIDLOTHIAN RETAIL
ADDRESS : 11309 MIDLOTHIAN TURNPIKE
SUBMISSION DATE : 8/3/17
PLAN DATED : 8/1/17
REVIEW DATE : 8/17/17
SITE PLAN NO. : 18PR0115
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW :
PLAT PROCESS :
. PLACE COUNTY PROJECT NUMBER 17-0163 ON THE LOWER RIGHT
CORNER OF EACH SHEET.
PLEASE PUT UTILITIES CONTACT RANDY PHELPS, 796-7126, PHELP
LD.GOV ON THE COVER SHEET.
3. PROVIDE DETAILS FOR:
" DOGHOUSE MANHOLE (NOTE: UTILITIES REVIEW ENGINEER WILL E
" INSIDE DROP MANHOLE CONNECTION (USE UTILITIES SPEC. DETA
" FIRE HYDRANT INSTALLATION (USE UTILITIES SPEC. DETAIL FI
4)
RELOCATE THE PROPOSED MONITORING MANHOLE OUT OF THE DRIVE
SLE. SHIFT APPROX. 20 FEET TO NEAREST GRASSY AREA AT END O
PARKING ROW.
SHOW THE SEWER EASEMENT AS TERMINATING JUST BEFORE THE
MONITORING MANHOLE. THE MONITORING MANHOLE IS TO BE "PRIVA
".
6. SHOW BACKFLOW PREVENTION DEVICES BEHIND BOTH THE DOMEST
AND IRRIGATION METERS.
7. LABEL THE 6" FIRE HYDRANT SUPPLY LINE AND DENOTE AS "PU
IC".
8. SHOW A PUBLIC WATER EASEMENT TO INCLUDE THE PROPOSED FI
HYDRANT AND SUPPLY LINE, AND THE DOMESTIC AND IRRIGATION
TERS.
LABEL THE 8" SEWER LINE AS "PUBLIC" AND THE 6" SERVICE LIN
AS "PRIVATE".
ON SHEET C01, ON THE MATERIALS LIST, DENOTE THAT THE 6"
FIRE LINE AND HYDRANT, AND 8" SEWER LINE AND ONE MANHOLE A
IC"; ALL ELSE ARE "PRIVATE".
11. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF RANDY PHELPS
(PHELPSC@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS).
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RANDY PHELPS / 804-796-7126
NAME OF PLAN : MIDLOTHIAN RETAIL
ADDRESS : 11309 MIDLOTHIAN TURNPIKE
SUBMISSION DATE : 11/1/17
PLAN DATED : 10/27/17
REVIEW DATE : 11/8/17
SITE PLAN NO. : 18PR0115
COMMENTS : 2ND REVIEW-NOT APPROVED
TABLE REVIEW :
PLAT PROCESS :
1. PREVIOUS COMMENT #4 REGARDING MOVING THE MONITORING M
HOLE HAS BEEN ADDRESSED THANKS! HOWEVER, WE NOTE THAT
E LANDSCAPING PLAN (L01) SHOWS A SMALL CALIBER TREE TO BE
LOCATED IN CLOSE PROXIMITY. PLEASE SHIFT THE MANHOLE WEST
WARDS THE FIRST PARKING SPACE TO MAXIMIZE THE SEPARATION B
2. PLEASE SUBMIT HARD COPIES OF THE METER SIZING FORMS FOR
HE DOMESTIC AND IRRIGATION METERS, WHICH WE WILL FORW
D TO OUR NEW CONSTRUCTION SECTION.
THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF RANDY PHELPS
(PHELPSC@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS).
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: MIDLOTHIAN RETAIL
SITE PLAN NUMBER: 18PR0115
LATEST PLAN DATE: 08/01/17
DEPT. REC'D. DATE: 08/08/17
SUBMITTAL NUMBER: ONE (TUGWELL)
REVIEW DATE: 08/09/17
RECOMMENDATION: SUBSTANTIAL APPROVAL
PLAT PROCESSING: R/W DEDICATION - ROUTE 60
.
FINAL SITE PLAN APPROVAL IS PENDING RIGHT-OF-WAY DEDICATIO
ALONG ROUTE 60 TO ACCOMMODATE THE SIDEWALK.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: MIDLOTHIAN RETAIL
SITE PLAN NUMBER: 18PR0115
LATEST PLAN DATE: 08/01/17
DEPT. REC'D. DATE: 11/01/17
SUBMITTAL NUMBER: TWO (TUGWELL)
REVIEW DATE: 11/02/17
RECOMMENDATION: SUBSTANTIAL APPROVAL
PLAT PROCESSING: R/W DEDICATION - ROUTE 60
.
FINAL SITE PLAN APPROVAL IS PENDING RIGHT-OF-WAY DEDICATIO
ALONG ROUTE 60.
==========================================================
==========================================================
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE # --STEVE TUGWELL /(804)768-7566
EMAIL------------------TUGWELLS@CHESTERFIELD.GOV
NAME OF PLAN-----------MIDLOTHIAN RETAIL
SITE PLAN NUMBER-------18PR0115
ADDRESS----------------11309 MIDLOTHIAN TURNPIKE
ORIGINAL PLAN DATE-----8/1/17
LATEST PLAN DATE-------
DEPT. REC'D. DATE------8/3/17
SUBMITTAL NUMBER-------1
REVIEW DATE------------8/15/17
RECOMMENDATION---------NOT APPROVED
TABLE REVIEW-----------NO
LANDSCAPE PLAN STATUS- 1ST DRAFT SUBMITTED
ARCHITECTURAL ELEVATIONS- NOT YET SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT YET SUBMITTED
IRRIGATION/HOSEBIB PLAN- NOT YET SUBMITTED
REVIEW COMMENTS:
PUT A REVISION DATE ON THE RESUBMITTED PLANS.
RESUBMIT 10 FULL SETS & 1 COPY OF THE SITE PLAN
SHEET TO THE PLANNING DEPARTMENT FOR YOUR NEXT
REVIEW. PROVIDE A RESPONSE TO COMMENTS, USING THE
SPACE BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE
ADDRESSED EACH REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED. PROVIDE A
TRANSMITTAL LETTER TO DESCRIBE ANY CHANGES TO THE
PLANS NOT CAUSED BY STAFF REVIEW COMMENTS.
1. PROVIDE THE PROJECT SITE PLAN CASE NUMBER
(18PR0115) IN THE LOWER RIGHT-HAND CORNER OF
EACH SHEET. [19.1-27.F.]
2. PROVIDE DUMPSTER SERVICING HOURS LIMITATIONS
SIGN DETAILS ON SHEET C15. (THIS SITE IS WITHIN 1,000 FEET
F A-ZONED PROPERTY) [19.1-206.B.]
3. SETBACKS ARE MEASURED FROM THE ULTIMATE RIGHT-
OF-WAY. LABEL THE EXISTING RIGHT-OF-WAY AND THE
ULTIMATE RIGHT-OF-WAY ON ALL PUBLIC ROADS ON THE
SITE PLAN, EVEN IF THE ULTIMATE AND EXISTING
RIGHT-OF-WAY AND THE
ULTIMATE RIGHT-OF-WAY ON ALL PUBLIC ROADS ON THE
SITE PLAN, EVEN IF THE ULTIMATE AND EXISTING
RIGHT-OF-WAY ARE THE SAME. [19.1-209.B.]
4. PROVIDE A SITE LIGHTING PLAN THAT PROVIDES CATA
G CUT-SHEETS AND MODEL NUMBERS FOR ALL EXTERIOR LIGH
NG SOURCES. ALSO PROVIDE THE MOUNTING HEIGHT. ALSO
RIFY THAT ALL FIXTURES ARE FULL CUT-OFF, THAT DIRECT L
HT SOURCE IS SHIELDED FROM VIEW, AND DOWNWARD DIRECTI
AL. [19.1-205]
5. THE TOTAL NUMBER OF TREES IN A PARKING LOT SHALL
BE 1 PER 200 SQUARE FEET OF LANDSCAPE AREA IN
THE PARKING LOT. SHOW THE CALCULATION FOR TOTAL
NUMBER OF TREES. [19.1-253.C.]
6. AT LEAST 50% OF THE TREES SHALL BE LARGE
MATURING TREES THAT ARE IN ISLANDS WITH A
MINIMUM WIDTH OF 15 FEET AND 250 SQ. FT. IN
SIZE. SMALL MATURING TREES SHALL BE IN ISLANDS
WITH A MINIMUM WIDTH OF 9 FEET AND 150 SQ. FT.
IN SIZE. [19.1-253.C.]
7. STAFF RECOMMENDS REDUCING THE PARKING IN THE
EAST-CENTRAL LOT FROM 18 SPACES TO 16
SPACES, AND WIDENING THE LANDSCAPE ISLAND ON
THE EASTERN SIDE OF THE SITE. THIS WILL
COMPENSATE FOR THE LACK OF TREES IN THE FRONT
SETBACK DUE TO EASEMENTS AND VISIBILITY TO
EXISTING SIGNS.
8. STAFF RECOMMENDS CREATING A LANDSCAPE ISLE ON
THE SOUTH END OF THE LOADING AREA, WHERE
VEGETATION IS LACKING AND THE LOADING AREA IS
EXPOSED.
9. SUBSTITUTE THE BOSQUE ELM WITH A CREPE MYRTLE
IN FRONT OF THE PATIO LOCATION. THIS WILL
INCREASE VISIBILITY TO WALL-MOUNTED BUILDING
SIGNAGE, WHILE PROVIDING SHADE TO THE OUTDOOR
AREA. ALSO, IS THERE A SITE-DISTANCE EASEMENT
FOR THE EXISTING OUTDOOR ADVERTISING SIGN ON
THE ADJACENT PROPERTY LOCATED TO THE WEST?
10. PROVIDE 2 COPIES OF RENDERINGS/ELEVATIONS OF
THE PROPOSED BUILDING THAT INCLUDE MATERIALS
AND COLORS IDENTIFIED, LOCATIONS OF JUNCTION
AND ACCESS BOXES SHOWN, AND HOW ALL MECHANICAL
EQUIPMENT IS SCREENED WHETHER IT IS GROUND-
MOUNTED OR MOUNTED ON THE ROOF. PLEASE LABEL
ELEVATIONS AS NORTH, SOUTH, EAST, AND WEST.
ALSO, PLEASE NOTE THAT JUNCTION BOXES SHOULD
EITHER BE INTEGRATED INTO THE ARCHITECTURAL
TREATMENT OF THE BUILDING, OR PAINTED TO MATCH
THE EXTERIOR. ALSO, PROVIDE A DETAIL FOR
THE ORNAMENTAL FENCE AROUND THE OUTDOOR PATIO
AREA. [19.1-317.A.]
11. SHOW THE LOCATION OF THE ROOF ACCESS. EXTERIOR
LADDER ACCESS AND PARAPET OPENINGS SHALL NOT BE
VISIBLE FROM ADJACENT PROPERTIES AND PUBLIC
RIGHT-OF-WAYS. ANY EXTERIOR ACCESS MUST BE
DESIGNED IN A MANNER INTERGRAL TO THE
BUILDING'S ARCHITECTURE. RECOMMEND PROVIDING
INTERIOR ACCESS IF POSSIBLE.
12. SHOW A CONNECTION FROM THE PROPOSED SIDEWALK
PERPENDICULAR INTO THE SITE, AND PROVIDE A
PAINTED CROSSWALK IN THE DRIVE-THRU LANE TO THE
SIDEWALK IN FRONT OF THE PROPOSED BUILDING.
[19.1-231.F.]
13. PLEASE VERIFY THE CORRECT PROPERTY OWNER NAME
STATED FOR GPIN# 742-708-5328.
14. ALL JUNCTION BOXES AND ELECTRICAL TRANSFORMERS
MUST EITHER BE INTEGRATED INTO THE
ARCHITECTURAL TREATMENT OR SCREENED ON AT LEAST
THREE (3) SIDES WITH SHRUBBERY OR LATTICE.
[19.1-317.C.1]
15. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A
READILY AVAILABLE WATER SUPPLY. THE COUNTY
ACCEPTS EITHER YARD HYDRANTS AND/OR HOSE BIBS
WITHIN 100 FEET OF ALL NEW PLANTINGS OR AN
IRRIGATION SYSTEM FOR ALL AREAS OF NEW
PLANTINGS. [19.1-249]
REVIEW NOTES:
1. PER THE INTERNATIONAL FIRE CODE, FEDERAL
REGULATIONS FOR HIGH VOLTAGE TRANSMISSION
LINES, THE COUNTY CPTED POLICY, AND COUNTY
ORDINANCE SEC. 19.1-246, THE DESIGN OF PARKING
AREAS SHALL FULLY CONSIDER AND PLAN TO
MINIMIZE POTENTIAL CONFLICTS BETWEEN
MATURING LANDSCAPING AND THE VISIBILITY AND
ACCESS TO FIRE HYDRANTS, CLEARANCES TO HIGH
POWER TRANSMISSION LINES, SITE LIGHTING, AND
VISIBILITY FOR MOTORISTS EXITING PARKING ROWS.
SITE LAYOUT SHALL BE CHECKED TO DETERMINE THAT
SUFFICIENT INTERNAL PARKING LOT PLANTING AREAS
EXISTS TO MEET THE REQUIREMENTS OF SEC. 19.1-
253 WITH FIRE HYDRANTS AND RELATED UTILITY
BOXES, AND CONFLICTS WITH OVERHEAD POWER LINES
AND SITE LIGHTING.
2. LANDSCAPING SURETY REQUIREMENTS AND MAINTENANCE
SHALL BE PERFORMED IN ACCORDANCE WITH SEC.
19.1-248.A & B. OF THE ZONING ORDINANCE.
3. MAINTENANCE GUARANTEE: PRIOR TO RECEIVING AN
OCCUPANCY PERMIT. THE APPLICANT SHALL PROVIDE A
LETTER OF GUARANTEE (COUNTY FORMAT) TO INSURE
REPLACEMENT OF UNHEALTHY, DYING, DEAD OR
POLLARDED LANDSCAPING WITHIN THE FIRST YEAR OF
INSTALLATION, PER SEC. 19.1-248.B.
4. LANDSCAPE REPLACEMENT SHALL BE REGULATED PER
SEC. 19.1-249.1., 2., & 3. OF THE ZONING
ORDINANCE.
5. PLEASE NOTE THAT IF ANY OUTDOOR MUSIC OR OUTDOOR
PUBLIC ADDRESS INTERCOMS ARE PROPOSED, THEY ARE
ALLOWED ONLY BY CONDITIONAL USE IN THE C-5
ZONING DISTRICT.
6. SIGNAGE SHALL REQUIRE A SEPARATE SIGN PERMIT.
**********END OF 1ST PLANNING REVIEW*************
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON (N)768-7549
PROJECT NAME : MIDLOTHIAN RETAIL
CASE NUMBER : 18PR0115
LATEST PLAN DATE : 8/1/17
RECEIVED DATE : 8/7/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 8/7/17
ADDRESS : PENDING
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. IT IS UNCLEAR FROM THE PLAN WHETHER THIS BUILDING
WILL HAVE ONE TENANT OR MORE THAN ONE TENANT. PLEASE
CONFIRM SO CORRECT ADDRESSING CAN BE DONE.
.
2. SHOW THE LOCATION OF THE MAIL BOX KIOSKS OR CLUSTER
BOXES ON THE PLAN SHEET OR INDICATE IN WHICH BUILDING THEY
ARE LOCATED. ONLY IF MORE THAN ONE TENANT IN THE BUILDING.
.
3. STREET ADDRESS LOCATION IS NOT SHOWN. IT CAN BE
LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF A
MONUMENT SIGN. LOCATION AND MATERIAL USED MUST BE NOTED
ON THE SITE PLAN. IF YOU ARE USING A MONUMENT SIGN, A
DETAIL OF THE MONUMENT SIGN MUST BE ON THE SITE PLAN.
.
4. IF THE ADDRESS IS TO BE ON THE BUILDING, YOU MUST
SHOW WHERE IT WILL BE LOCATED ON THE BUILDING AND WHAT
IT WILL BE MADE OF. IF THE ADDRESS IS TO BE ON A PYLON
SIGN, YOU MUST SHOW WHERE IT WILL BE LOCATED ON THE
PROPERTY AND WHAT IT WILL BE MADE OF.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON (N)768-7549
PROJECT NAME : MIDLOTHIAN RETAIL
CASE NUMBER : 18PR0115
LATEST PLAN DATE : 10/27/17
RECEIVED DATE : 10/29/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 11/16/17
ADDRESS : 11309 AND 11311 MIDLOTHIAN TPKE 23235
STATUS : APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: MIDLOTHIAN RETAIL
SITE PLAN NUMBER: 18PR0115
ADDRESS: 11309 MIDLOTHIAN TURNPIKE
LATEST PLAN DATE: 8/1/17
DEPT. REC'D. DATE: 8/8/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 8/11/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. PROVIDE COMPUTER GENERATED WATER FLOW TEST DATA,
PROVIDED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT, VERIFYING THE REQUIRED WATER FLOW FOR FIRE
PROTECTION IS AVAILABLE AT THE SITE. THE WATERFLOW TEST
RESULTS AND GRAPH SHALL BE SHOWN ON THE SUBMITTED PLAN.
THE MINIMUM REQUIRED FIRE FLOW FOR ALL BUILDINGS, WITH
THE EXCEPTION OF ONE AND TWO-FAMILY DWELLINGS, IS 1500
GPM (SPRINKLER PROTECTED OR NON-SPRINKLER PROTECTED) IN
ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (2012) -
SECTION B105.2 AND TABLE B105.1.
2. SHOW THE NODE MAP AND RESULTS TABLE FOR THE PROPOSED
OR EXISTING HYDRANTS ON SITE SHOWING THE MAXIMUM FIRE
FLOW CAN BE ACHIEVED. WHEN MULTIPLE FIRE HYDRANTS ARE
USED THE COMBINED FLOW MUST BE SIMULTANEOUS.
3. THE APPROXIMATE LOCATION OF ALL REQUIRED FIRE LANE
SIGNS AND CURB / STREET MARKING SHALL BE INDICATED ON
THE PLAN. FIRE LANES THAT ARE BETWEEN TWENTY AND
TWENTY-SIX FEET IN WIDTH SHALL BE POSTED AND MARKED ON
BOTH SIDES OF THE ROADWAY. FIRE LANES IN EXCESS OF
TWENTY-SIX FEET IN WIDTH UP TO THIRTY-TWO FEET IN WIDTH
SHALL BE POSTED AND MARKED ON ONE SIDE OF THE
ROADWAY. THE LOCATION OF AND METHOD OF MARKING FIRE
LANES SHALL BE CLEARLY INDICATED ON THE SUBMITTED SITE
PLAN. ALL FIRE LANE SIGNS SHALL BE DOUBLE FACED AND
INSTALLED PERPENDICULAR TO THE CURB.
4. PARKING STALLS OR OTHER OBSTRUCTIONS, AS INDICATED IN
THE INTERNATIONAL FIRE CODE (2012) - SECTION 508.5.4,
SHALL NOT BE PLACED IN FRONT OF THE ACCESS TO FIRE
HYDRANTS, FIRE PUMP TEST HEADERS, FIRE DEPARTMENT
SPRINKLER SYSTEM CONNECTIONS, FIRE DEPARTMENT STANDPIPE
CONNECTIONS OR FIRE PROTECTION SYSTEM CONTROL VALVES.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: MIDLOTHIAN RETAIL
SITE PLAN NUMBER: 18PR0115
ADDRESS: 11309 MIDLOTHIAN TURNPIKE
LATEST PLAN DATE: 10/27/17
DEPT. REC'D. DATE: 11/2/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 11/2/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.