Site Plan Review Comments
All Site Plan Review Comments for Case # 17PR0264
Modify comments view for Case # 17PR0264

Go to Case Selection Form or Go to Project List

 
CASE NO: 17PR0264 STATUS: PENDING APPROVAL
PROJECT NAME: RESIDENCE INN HOTEL - LAST INTERNET UPDATE: 07/19/18
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ENVIR.ENGR.-: 04 06/01/18 06/22/18 ******** ********
FIRE DEPT.--: 04 06/01/18 06/22/18 COMPLETE 06/07/18 AWB 717-6167
MAPPING/GIS-: 04 06/01/18 06/22/18 COMPLETE 06/25/18 AMJ 768-7549
PLANNING----: 04 06/01/18 06/22/18 COMPLETE 06/08/18 BSM 717-6143
TRANSPORT.--: 04 06/01/18 06/22/18 COMPLETE 06/07/18 SJA 751-4461
UTIL.PLAN.--: 04 06/01/18 06/22/18 ******** ********
UTILITIES---: 04 06/01/18 06/22/18 ******** 12/29/17 LV 748-1863
UTIL.R.O.W.-: 04 06/01/18 06/22/18 ******** ********
VDOT--------: 04 06/01/18 06/22/18 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : LINNETTE VASQUEZ, P.E./748-1863
NAME OF PLAN : RESIDENCE INN HOTEL
ADDRESS : 10701 CENTER VIEW DR AND PART OF 1021
KOGER CENTER BLVD.
SUBMISSION DATE : 7/5/17
PLAN DATED : 6/22/17
REVIEW DATE : 7/20/17
SITE PLAN NO. : 17PR0264
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW :
PLAT PROCESS :
*
1. UTILITIES PROJECT 17-0140 NUMBER SHALL BE PLACED ON
THE LOWER RIGHT HAND CORNER OF EACH SHEET.
*
2. UPDATE PUBLIC AND PRIVATE MATERIALS LIST PER FOLLOWING
COMMENTS.
*
3. PROVIDE A COPY OF NOTIFICATIONS TO ALL ADJACENT
PROPERTY OWNERS PRIOR TO PERFORMING ANY DESIGN AND/OR
SURVEYING WORK. COORDINATE WITH APPLICABLE ADJACENT
PROPERTY OWNERS IN REGARDS TO ANY POSSIBLE IMPACTS
INCLUDING BUT NOT LIMITED TO PROPERTY ACCESS.
*
4. PROVIDE A SIGNED ENGINEERS CHECKLIST.
*
5. ADD DETAIL DES-2 TO PLANS. REVISE STANDARD SEWER AND
WATER NOTE #4 INDICATING AN ELEVATION AT OR BELOW 301 FEET
*
6. PROVIDE VERTICAL BAR SCALE ON PROFILE SHEETS.
*
7. PROVIDE WATERLINE STATIONING ON UTILITY PLAN SHEET.
*
8. NO STRUCTURES MAY BE PROPOSED IN ANY EXISTING OR
PROPOSED WATER OR SEWER EASEMENT. THIS INCLUDES ALL
PROPOSED STORM SEWERS, ETC. MOVE PROPOSED STORAGE BUILDING
OUTSIDE OF SEWER EASEMENT.
*
9. SHOW AND LABEL CLEARLY ALL EXISTING EASEMENTS
ACCURATELY AND PROVIDE RECORDATION INFORMATION INCLUDING
EXISTING SANITARY SEWER AND EASEMENT.
*
10. FIELD VERIFY SEWER TIE IN MANHOLE INFORMATION
INCLUDING TOP ELEVATION.
*
11. ARE THERE ANY EXISTING SERVICES OR LATERALS THAT ARE
PROPOSED TO BE ABANDONED?
*
12. PROVIDE LOCATION OF VERTICAL BENCH MARK ON PLANS.
*
13. LABEL ALL EXISTING AND PROPOSED STORM SEWER LINES,
GAS, TELEPHONE, POWER, AND OTHER UTILITY LINES WHICH CROSS
OR RUN PARALLEL TO THE SEWER OR WATER MAINS. LABEL CROSSIN
ON SHEET C4.2 AT APPROXIMATE STATION 3+25.
*
14. LABEL REFERENCE DISTANCES FROM PROPOSED WATERLINE TO
RIGHT OF WAY, OTHER UTILITY LINES, FACE OF CURB, ETC. ON
UTILITY PLAN SHEET.
*
15. SHOW EXISTING AND PROPOSED WATER AND SEWER LINES ON
LIGHTING AND LANDSCAPING PLAN BEING PROPOSED TO ENSURE THA
NO LIGHT POLES OR TREES LOCATED WITHIN A WATER OR SEWER
EASEMENT.
*
16. PROVIDE A MINIMUM OF TWO VALVES FOR TEES AND THREE
VALVES FOR CROSSES INCLUDING FIRE HYDRANT TEES.
*
17. SHOW AND LABEL ALL EXISTING VALVES AND TEES NEAR
WATERLINE CONNECTION POINTS INCLUDING VALVES TO BE USED FO
CUT-OFF DURING TIE-IN. CALCULATE AND LABEL DISTANCE FROM
EXISTING VALVES TO PROPOSED CONNECTION.
*
18. REVISE SIMULTANEOUS FLOW TEST INFORMATION RESULTS ON
WATER FLOW INFORMATION AS PER DES-5 ON WATER MODEL & FLOW
CALCULATION SHEET. FLOW SIMULTANEOUSLY THE REQUIRED MINIMU
REQUIRED FIRE FLOW AT THE REQUIRED NUMBER OF HYDRANTS.
*
19. VERIFY ALL INFORMATION INDICATED ON METER SIZING FORM
INCLUDES ALL PROPOSED FIXTURES. INDICATE IF AN IRRIGATION
SYSTEM WILL BE PROPOSED WITH THIS PROJECT.
*
20. INDICATE IF THERE WILL BE A COMMERCIAL KITCHEN FOR THE
PROPOSED PROJECT. A GREASE TRAP AND MONITORING MANHOLE MAY
BE REQUIRED DEPENDING ON THE PROPOSED USE.
*
21. IF REQUIRED THE MONITORING MANHOLE WILL BE PRIVATE AND
LOCATED IN A GRASSY AREA IF POSSIBLE. IT NEEDS TO BE
LOCATED OUTSIDE THE EASEMENT AND ON THE PROJECT PROPERTY.
*
22. THE DOMESTIC LINE NEEDS TO BE SEPARATED AND THEN FLOW
BACK BEFORE THE MONITORING MANHOLE. REFER TO MONITORING
MANHOLE DETAIL.
*
23. PROVIDE AND LABEL DOUBLE CHECK ASSEMBLY BACKFLOW
PREVENTION AS APPLICABLE.
*
24. PROVIDE THRUST PROTECTION AT ALL BENDS, TRANSITIONS,
AND END OF LINES. ADD NOTE TO PROFILE FOR FITTINGS. FOR EN
OF WATERLINE CALCULATE AND LABEL LENGTH THE RESTRAINT
SYSTEM. CLEARLY SHOW AND LABEL ON PROFILE SHEET.
*
25. NOTE ON PLAN AND PROFILE SHEETS THAT ALL VALVE BOXES,
MANHOLE FRAME AND COVERS, ARVS, WATER METERS, BLOW-OFFS,
ETC. AFFECTED BY PROPOSED GRADING WORK TO BE ADJUSTED TO
FINAL GRADE.
*
26. SHOW FDC IN VAULT NO MORE THAN 100 FEET AWAY FROM
DEDICATED HYDRANT.
*
27. UPDATE DETAILS TO INCLUDE AS APPLICABLE MONITORING
MANHOLE, FIRE LINE CONNECTIONS, ETC.
*
28. VERIFY THAT SEWER HYDRAULIC ANALYSIS HAS BEEN
CONDUCTED FOR THIS PROPOSED USE.
*
29. PROVIDE A PDF TO VASQUEZL@CHESTERFIELD.GOV WITH THE
NEW PROPOSED CONFIGURATION FOR THE FDC AND SEWER LINE TO
REVIEW PRIOR TO RESUBMITTAL.
*
30. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF LINNETTE VASQUEZ
(VASQUEZL@CHESTERFIELD.GOV). THE BID PROPOSAL
MUST BE BASED ON THE APPROVED SITE PLAN. BE ADVISED THAT I
THE SITE PLAN IS REVISED AND REAPPROVED SUBSEQUENT TO THE
PREPARATION OR RECORDATION OF THE UTILITIES CONTRACT, THE
BID PROPOSAL SHALL BE REVISED ACCORDINGLY AND A REVISED
UTILITIES CONTRACT MAY BE NECESSARY.
*
31. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN ADDITI
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS).
**********************************************************
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : LINNETTE VASQUEZ, P.E./748-1863
NAME OF PLAN : RESIDENCE INN HOTEL
ADDRESS : 10701 CENTER VIEW DR AND PART OF 1021
KOGER CENTER BLVD.
SUBMISSION DATE : 11/2/17
REVISION DATE :11/16/17
REVIEW DATE : 12/13/17
SITE PLAN NO. : 17PR0264
COMMENTS : 2ND REVIEW-NOT APPROVED
TABLE REVIEW : REFER TO COMMENT # 17
PLAT PROCESS :
*
1. IN REFERENCE TO PREVIOUS COMMENT #2, UPDATE PUBLIC AND
PRIVATE MATERIALS LIST PER FOLLOWING COMMENTS.
*
2. CLEARLY LABEL PUBLIC AND PRIVATE WATERLINE ON PLANS.
ALL WATERLINES PASSED PROPOSED WATER METER TO BE PRIVATE.
UPDATE PROPOSED EASEMENTS NEAR METER AS APPLICABLE. FIRE
LINE VALVE NEEDS TO BE RIGHT AT EDGE OF EASEMENT.
*
3. PROVIDE APPROXIMATE LOCATION OF WATERLINE JUMPER
LOCATION. PROVIDE DETAIL ON PLANS.
*
4. IN REFERENCE TO PREVIOUS COMMENT # 4, PROVIDE A HARD
COPY OF SIGNED ENGINEERS CHECKLIST. EMAIL NOT RECEIVED.
*
5. IN REFERENCE TO PREVIOUS COMMENT # 8, NO STRUCTURES
MAY BE PROPOSED IN ANY EXISTING OR PROPOSED WATER OR SEWER
EASEMENT WITHOUT A LICENSE AGREEMENT. THIS INCLUDES ALL
SIGNS, CURB AND GUTTER, PARKING ISLANDS, ETC. PLEASE
CONTACT JOAN COURSON AT 804-748-1362 AND/OR
COURSONJ@CHESTERFIELD.GOV FOR ANY QUESTIONS CONCERNING
OBTAINING A LICENSE.
*
6. IN REFERENCE TO PREVIOUS COMMENT # 9, SHOW AND LABEL
CLEARLY ALL EXISTING SEWER EASEMENT NEAR CONNECTING MANHOL
WITH SIZE AND RECORDATION INFORMATION.
*
7. IN REFERENCE TO PREVIOUS COMMENT # 10, REVISE DROP TO
BE UNDER 2 FEET OR SHOW PROPOSED DROP INLET CONNECTION.
MATCH CROWNS TO EXISTING SEWER LINE. SHOW EXISTING STORM
SEWER LINE AND SEPARATION DISTANCE ON SEWER LATERAL
PROFILE.
*
8. IN REFERENCE TO PREVIOUS COMMENT # 13, LABEL ALL
EXISTING WATER AND SEWER LINES WITH SIZE AND UTILITIES
PROJECT NUMBER ON BOTH PLAN AND PROFILE VIEWS.
*
9. IN REFERENCE TO PREVIOUS COMMENT #14, CLEARLY LABEL
DISTANCE OF PROPOSED FIRE HYDRANTS FROM CURB AND GUTTER A
MINIMUM OF 3 FEET BEHIND.
*
10. SHOW EXISTING SEWER LINE ON BMP PLAN SHEET C5.2 ON
PLAN AND PROFILE VIEWS. PROVIDE A CROSS SECTION OF THE
EXISTING SEWER LINE THE DISTANCE FROM THE OUTSIDE LIMITS O
THE BMP TO THE EXISTING ROAD. CLEARLY SHOW EXISTING AND
PROPOSED COVER OVER EXISTING LINE. PLEASE NOTE ADDITIONAL
REQUIREMENTS AND/OR NOTES MAY BE REQUIRED DEPENDING ON THE
INFORMATION PROVIDED.
*
11. IN REFERENCE TO PREVIOUS COMMENT # 15, CLEARLY SHOW
EXISTING SEWER EASEMENTS ON LIGHTING AND LANDSCAPING PLAN
TO ENSURE THAT NO LIGHT POLES OR TREES ARE LOCATED WITHIN
WATER OR SEWER EASEMENT.
*
12. IN REFERENCE TO PREVIOUS COMMENT # 18, ADD NOTE THAT
THE THREE FIRE FLOWS OF 1,000 GPM FOR EACH HYDRANT HAVE
BEEN RUN SIMULTANEOUSLY. REFER TO DETAIL DES-5.
*
13. IN REFERENCE TO PREVIOUS COMMENT # 20 AND # 22,
INDICATE THE KIND OF FOOD PREPARATION THAT WILL BE SERVED
AT THE HOTEL AND THE APPROXIMATE AMOUNT OF GREASE
PRODUCTION. DEPENDING ON THE AMOUNT OF GREASE BEING
PROPOSED WILL DETERMINE WHETHER AN INSIDE OR OUTSIDE GREAS
TRAP WILL BE REQUIRED AND IF THE DOMESTIC LINE NEEDS TO BE
SEPARATED BEFORE THE MONITORING MANHOLE.
*
14. IN REFERENCE TO PREVIOUS COMMENT # 21, PROVIDE A
PRIVATE MONITORING MANHOLE LOCATED IN A GRASSY AREA IF
POSSIBLE. IT NEEDS TO BE LOCATED OUTSIDE THE EASEMENT AND
ON THE PROJECT PROPERTY. A CLEANOUT AND/OR MONITORING
MANHOLE IS REQUIRED AT THE EDGE OF THE EXISTING SEWER
EASEMENT SHOW AND CLEARLY LABEL ON PLAN AND PROFILE VIEWS
THE LIMITS OF THE PUBLIC AND PRIVATE SEWER.
*
15. IN REFERENCE TO PREVIOUS COMMENT # 23, A RP IS
REQUIRED ON THE WATER DOMESTIC LINE SINCE THE BUILDING WIL
BE FOUR STORIES.
*
16. IN REFERENCE TO PREVIOUS COMMENT # 23, THE PROPOSED
BACKFLOW PREVENTER MUST BE WITHIN FIFTY FEET OF THE MAIN
WATERLINE. MOVE OUTSIDE OF BUILDING IF NECESSARY.
*
17. IF A FIRE PUMP IS PROPOSED CONNECTION TO THE LINE
NEEDS TO BE DOWNSTREAM OF THE PUMP. PLEASE CONFIRM.
*
18. IN REFERENCE TO PREVIOUS COMMENT # 26, LABEL DEDICATED
HYDRANT WITHIN 50 FEET FROM FDC.
*
19. IN REFERENCE TO PREVIOUS COMMENT # 27, UPDATE DETAILS
TO INCLUDE AS APPLICABLE MONITORING MANHOLE, FIRE LINE
CONNECTIONS, JUMPER, ETC.
*
20. PROVIDE A PDF WITH A DRAFT OF PROPOSED CHANGES
HIGHLIGHTED PRIOR TO RESUBMITTAL TO
VASQUEZL@CHESTERFIED.GOV IN ORDER TO VERIFY THAT ALL
COMMENTS HAVE BEEN ADDRESSED. PLEASE CALL WITH ANY
QUESTIONS AT 804-748-1863.
*
21. BE ADVISED THAT FOR ALL ONSITE PUBLIC WATERLINES
AND/OR SEWER LINES THAT ARE CONTAINED WITHIN EASEMENTS OR
PROPOSED RIGHTS-OF-WAY, THE EASEMENTS OR RIGHTS-OF-WAY MUS
BE DEDICATED PRIOR TO ACCEPTANCE OF UTILITIES INTO SYSTEM.
*
22. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF LINNETTE VASQUEZ
(VASQUEZL@CHESTERFIELD.GOV). THE BID PROPOSAL
MUST BE BASED ON THE APPROVED SITE PLAN. BE ADVISED THAT I
THE SITE PLAN IS REVISED AND REAPPROVED SUBSEQUENT TO THE
PREPARATION OR RECORDATION OF THE UTILITIES CONTRACT, THE
BID PROPOSAL SHALL BE REVISED ACCORDINGLY AND A REVISED
UTILITIES CONTRACT MAY BE NECESSARY.
*
23. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS).
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
LATEST PLAN DATE: 06/22/17
DEPT. REC'D. DATE: 06/30/17
SUBMITTAL NUMBER: ONE (BSMORRISON)
REVIEW DATE: 07/17/17
RECOMMENDATION: NOT APPROVED
PLAT PROCESSING: ADDITIONAL R/W OR ESMTS?
.
1. JOHNSTON WILLIS DR & CENTERVIEW DR ARE ON THE BIKEWAYS
& TRAILS PLAN. FACILITIES SHALL BE PROVIDED IN ACCORDANCE
WITH ZONING ORDINACE SECTION 19.1-208.
.
2. NOTE JOHNSTON WILLIS & CENTERVIEW AS URBAN LOCAL ROADS.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
LATEST PLAN DATE: 11/16/17
DEPT. REC'D. DATE: 11/22/17
SUBMITTAL NUMBER: TWO (BSMORRISON)
REVIEW DATE: 12/13/17
RECOMMENDATION: NOT APPROVED
PLAT PROCESSING: ADDITIONAL R/W OR ESMTS?
.
COUNTY STAFF IS REVIEWING THE PROPOSED BIKEWAYS/TRAILS
ACCOMMODATION AND COMMENTS WILL BE FORTHCOMING. DEVELOPER
IS REQUIRED TO ADDRESS THIS PLAN IN ACCORDANCE WITH ZONING
ORDINACE SECTION 19.1-208.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
LATEST PLAN DATE: 02/20/18
DEPT. REC'D. DATE: 02/26/18
SUBMITTAL NUMBER: THREE (BSMORRISON)
REVIEW DATE: 03/13/18
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
LATEST PLAN DATE: 04/25/18
DEPT. REC'D. DATE: 04/30/18
SUBMITTAL NUMBER: FOUR (MORRISON)
REVIEW DATE: 05/16/18
RECOMMENDATION: SUBSTANTIAL APPROVAL
PLAT PROCESSING: R/W DEDICATION - JOHNSTON WILLIS
CENTER VIEW
.
FINAL SITE PLAN APPROVAL IS PENDING RIGHT-OF-WAY DEDICATIO
ALONG JOHNSTON WILLIS DR AND COURT VIEW DR TO ACCOMMODATE
ROAD IMPROVEMENTS.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
LATEST PLAN DATE: 05/30/18
DEPT. REC'D. DATE: 06/05/18
SUBMITTAL NUMBER: FIVE (MORRISON)
REVIEW DATE: 06/07/18
RECOMMENDATION: SUBSTANTIAL APPROVAL
PLAT PROCESSING: R/W DEDICATION - JOHNSTON WILLIS
CENTER VIEW
.
FINAL SITE PLAN APPROVAL IS PENDING RIGHT-OF-WAY DEDICATIO
ALONG JOHNSTON WILLIS DR AND COURT VIEW DR TO ACCOMMODATE
ROAD IMPROVEMENTS.
==========================================================
==========================================================
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: BRAD MORRISON / 717-6143
PLAN NAME: RESIDENCE INN
PLAN NUMBER : 17PR0264
ORIGINAL PLAN DATE: 6/22/17
REVISION DATE:
LATEST SUBMISSION DATE: 6/28/17
REVIEW DATE: 7/21/17
SUBMITTAL NUMBER : 1
STATUS: REVISIONS REQUIRED
.
1. INCLUDE ZONING CASE #84SN0109 IN GENERAL NOTES.
[19.1-27F]
.. INCLUDE ZONING OF ADJACENT PROPERTY [19.1-27.F].
.
3. LABEL ON PLANS SETBACK EXCEPTIONS ALLOWED BY
ZONING CASES (84SN01090 [19.1-316].
.
4. COMMENT 4 RETRACTED
.
.
5. SHOW WIDTHS OF ALL DRIVES. WIDTH REQUIREMENT
LISTED IN SEC. 19.1-238.C.
.
6. LABEL PARKING SPACES OCCUPIED BY OFF-SITE-USE.
SPECIFY THE ZONING OF THE OFF-SITE USE OCCUPYING
ONSITE PARKING. [19.1-235B]. USE OF OFF SITE PARKING
SHOULD BE LEASED AND RECORDED WITH CLERK OF THE
CIRCUIT COURT.
.
7. LABEL SQUARE FOOTAGE OF LANDSCAPED AREAS
UTILIZED FOR PARKING LOT LANDSCAPING [19.1-253.B].
.
8. THE PROPERTY IS LOCATED ON THE BIKEWAY AND
TRAILS PLAN ON JOHNSTON WILLIS DR AND
CENTERVIEW DR. ADEQUATE FACILITIES MUST BE
INSTALLED ON BOTH FRONTAGES.
THE PROVIDED FACILITIES MUST BE CONSISTENT
WITH THE RECOMMENDATIONS OF THE BIKEWAY AND
TRAILS CHAPTER OF THE COMPREHENSIVE PLAN.
[19.1-27], [19.1-208].
.
ANY OPTION RECOMMENDED BY THE COMPREHENSIVE
MAY BE EXPLORED. A 10' SHARED USE PATH
IS AN OPTION. A 5' BIKE LINE IN CONJUNCTION
WITH A 5' SIDEWALK IS ANOTHER OPTION. IF THE
BIKE LANE AND SIDEWALK OPTION IS CHOSEN,
CENTERIVIEW DR WOULD NEED SIDEWALK INSTALLED.
THE CURB TO CURB WIDTH WILL ACCOMMODATE
STRIPING OF A BIKE LANE AT A LATER DATE.
JOHNSTON WILLIS DRIVE WOULD NEED A SIDEWALK
IN ADDITION TO THE FOLLOWING IMPROVEMENTS
TO ACCOMMODATE A STRIPED BIKE LANE:
A BIKE LANE ALONG THE ENTIRE PROPERTY
FRONTAGE TO JOHNSTON WILLIS DRIVE AND DEDICATE
APPROPRIATE RIGHT-OF-WAY TO ACCOMMODATE THE
FACILITY TO ENSURE VDOT MAINTENANCE. THIS WOULD
RESULT IN 5' PAVEMENT WIDENING WITH DITCH AND
SHOULDER SECTION OR 4' PAVEMENT WIDENING WITH
CURB/GUTTER SECTION, INCLUDING PAVEMENT
MARKINGS AND ASSOCIATED SIGNAGE REQUIRED
BY VDOT. THIS IMPROVEMENT WILL REQUIRE
MODIFICATIONS TO THE EXISTING GUARDRAIL AND
CONCRETE TOWARDS THE SOUTHERN PROPERTY LINE.
LINEAR FOOTAGE OF BIKEWAYS AND TRAILS PROVIDED
SHALL BE LISTED IN THE SITE DATA ON THE COVER SHEET
OF THE SITE PLAN. OTHER DESIGNS CONSISTENT
WITH COMPREHENSIVE PLAN MAY PROPOSED SUCH AS
THE SHARED USE PATH.
.
CURB RAMPS SHOULD BE INSTALLED AT THE CORNER OF
JOHNSTON WILLIS AND CENTERVIEW DR. C
.
PLEASE NOTE PER ZONING ORDINANCE SECTION 19.1-209.B,
SETBACKS SHALL BE MEASURED WITHOUT INCLUDING
THE EXPANDED RIGHT-OF-WAY, EXCEPT THAT THE
SETBACK SHALL NOT BE LESS THAN ONE (1) FOOT
FROM THE EXPANDED RIGHT-OF-WAY.
.
9. PER SEC. 19.1-317 A, B, PROVIDE 2 COPIES OF
RENDERINGS/ELEVATIONS OF THE BUILDINGS WITH
ALL BUILDING MATERIALS AND COLORS IDENTIFIED,
LOCATIONS OF JUNCTION AND ACCESS BOXES SHOWN,
AND HOW ALL MECHANICAL EQUIPMENT IS SCREENED
WHETHER IT IS MOUNTED ON THE ROOF
OR ON THE GROUND.
.
PER SEC.19.1-317 A, B , OR ANY PROJECT WITH MORE THAN
ONE BUILDING, THE DEVELOPER SHALL SUBMIT DOCUMENTS
THAT DEFINE THE OVERALL ARCHITECTURAL THEME.
THE THEME SHALL DESCRIBE HOW EXTERIOR MATERIALS,
COLORS, ARCHITECTURAL STYLE AND BUILDING SCALE
SHALL BE USED TO DEVELOP A CONSISTENT ARCHITECTURAL TREATM
COMPATIBILITY IS REQUIRED BETWEEN BUILDINGS
WITHIN THE PROJECT.
.
10. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER
(17PR0264) IN THE LOWER RIGHT CORNER OF EACH SHEET.
[SEC. 19.1-27.F.]
.
11. PUT NOTE ON PLANS, "ALL PROPOSED UTILITIES ARE TO BE
INSTALLED UNDERGROUND INCLUDING ELECTRIC,
TELEPHONE AND CATV." [SEC. 19.1-27.F.]
***********************************************
REVIEW DEPARTMENT: PLANNING
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: BRAD MORRISON / 717-6143
PLAN NAME: RESIDENCE INN
PLAN NUMBER : 17PR0264
ORIGINAL PLAN DATE: 6/22/17
REVISION DATE:
LATEST SUBMISSION DATE: 11/16/17
REVIEW DATE: 12/7/17
SUBMITTAL NUMBER : 2
STATUS: REVISIONS REQUIRED
.
1. INCLUDE ZONING CASE #84SN0109 IN GENERAL NOTES.
[19.1-27F]- CHECK TYPO
.
2. LABEL PARKING SPACES OCCUPIED BY OFF-SITE-USE.
MUST DELINEATE ON SITE PLAN. SPECIFY THE ZONING
OF THE OFF-SITE USE OCCUPYING ONSITE PARKING.
[19.1-235B].
USE OF OFF SITE PARKING SHOULD BE LEASED AND
RECORDEDWITH CLERK OF THE CIRCUIT COURT.
.
3. PARKING TABULATION MUST INCLUDE THE NUMBER
REQUIRED AND PROVIDED SPACES FOR EACH SITE.
SPACES OCCUPIED BY ATHLETIC CLUB CANNOT
BE COUNTED IN SPACES PROVIDED FOR EITHER
HOTEL.
.
4. BIKEWAYS MUST BE CONSISTENT WITH THE
RECOMMENDATIONS OF THE BIKEWAY AND
TRAILS CHAPTER OF THE COMPREHENSIVE PLAN.
[19.1-27], [19.1-208]. THE PROPOSED FACILITIES
ARE NOT CONSISTENT WITH RECOMMENDATIONS.
ADDITIONALLY, THERE MUST BE A SEAMLESS
TRANSITION BETWEEN JOHNSTON WILLES AND
CENTERVIEW DRIVE.
.
PLEASE NOTE PER ZONING ORDINANCE SECTION 19.1-209.B,
SETBACKS SHALL BE MEASURED WITHOUT INCLUDING
THE EXPANDED RIGHT-OF-WAY, EXCEPT THAT THE
SETBACK SHALL NOT BE LESS THAN ONE (1) FOOT
FROM THE EXPANDED RIGHT-OF-WAY.
.
5. PER SEC. 19.1-317 A, B, PROVIDE 2 COPIES OF
RENDERINGS/ELEVATIONS OF THE BUILDINGS WITH
ALL BUILDING MATERIALS AND COLORS IDENTIFIED,
LOCATIONS OF JUNCTION AND ACCESS BOXES SHOWN,
AND HOW ALL MECHANICAL EQUIPMENT IS SCREENED
WHETHER IT IS MOUNTED ON THE ROOF
OR ON THE GROUND.
.
6. PER SEC.19.1-317 A, B , OR ANY PROJECT WITH MORE
THAN ONE BUILDING, THE DEVELOPER SHALL SUBMIT
DOCUMENTS THAT DEFINE THE OVERALL ARCHITECTURAL
THEME. THE THEME SHALL DESCRIBE HOW EXTERIOR
MATERIALS, COLORS, ARCHITECTURAL STYLE AND
BUILDING SCALE SHALL BE USED TO DEVELOP A
CONSISTENT ARCHITECTURAL TREATMENT. COMPATIBILITY
IS REQUIRED BETWEEN BUILDINGS WITHIN THE PROJECT.
************************************************
REVIEW DEPARTMENT: PLANNING
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: BRAD MORRISON / 717-6143
PLAN NAME: RESIDENCE INN
PLAN NUMBER : 17PR0264
ORIGINAL PLAN DATE: 6/22/17
REVISION DATE: 2/20/18
LATEST SUBMISSION DATE: 2/20/18
REVIEW DATE: 3/1/18
SUBMITTAL NUMBER : 3
STATUS: REVISIONS REQUIRED
TABLE REVIEW: YES - IF ARCHITECTURE IS SUBMITTED
AND APPROVED PRIOR TO.
.
1. ADD CURB RAMP TO SIDEWALK AT WESTERN MOST
SIDEWALK STUB ON CENTER VIEW DRIVE
[19.1-27], [19.1-208].
.
2. PER SEC. 19.1-317 A, B, PROVIDE 2 COPIES OF
RENDERINGS/ELEVATIONS OF THE BUILDINGS WITH
ALL BUILDING MATERIALS AND COLORS IDENTIFIED,
LOCATIONS OF JUNCTION AND ACCESS BOXES SHOWN,
AND HOW ALL MECHANICAL EQUIPMENT IS SCREENED
WHETHER IT IS MOUNTED ON THE ROOF
OR ON THE GROUND.
.
PER SEC.19.1-317 A, B , OR ANY PROJECT WITH MORE THAN
ONE BUILDING, THE DEVELOPER SHALL SUBMIT DOCUMENTS
THAT DEFINE THE OVERALL ARCHITECTURAL THEME.
THE THEME SHALL DESCRIBE HOW EXTERIOR MATERIALS,
COLORS, ARCHITECTURAL STYLE AND BUILDING SCALE
SHALL BE USED TO DEVELOP A CONSISTENT ARCHITECTURAL
TREATMENT. COMPATIBILITY IS REQUIRED BETWEEN
BUILDINGS WITHIN THE PROJECT.
****************************************
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: BRAD MORRISON / 717-6143
PLAN NAME: RESIDENCE INN
PLAN NUMBER : 17PR0264
ORIGINAL PLAN DATE: 6/22/17
REVISION DATE: 4/25/18
REVIEW DATE: 5/10/18
SUBMITTAL NUMBER : 4
STATUS: SUBSTANTIAL APPROVAL
TABLE REVIEW: YES
.
1. PER SEC. 19.1-317 A, B, PROVIDE 2 COPIES OF
RENDERINGS/ELEVATIONS OF THE BUILDINGS WITH
ALL BUILDING MATERIALS AND COLORS IDENTIFIED,
LOCATIONS OF JUNCTION AND ACCESS BOXES SHOWN,
AND HOW ALL MECHANICAL EQUIPMENT IS SCREENED
WHETHER IT IS MOUNTED ON THE ROOF
OR ON THE GROUND.
*************************************************
CURRENT PLANS SHOW BOTTOM EDGE LESS THAN 4 FEET.
REVIEWER / PHONE #: BRAD MORRISON / 717-6143
PLAN NAME: RESIDENCE INN
PLAN NUMBER : 17PR0264
ORIGINAL PLAN DATE: 6/22/17
REVISION DATE: 5/30/18
LATEST SUBMISSION DATE: 5/30/18
REVIEW DATE: 5/10/18
SUBMITTAL NUMBER : 5
STATUS: APPROVED WITH CONDITIONS
TABLE REVIEW: YES
CONDITIONS:
.
1. AT TIME OF BUILDING PERMIT THE LOCATIONS OF
JUNCTION AND ACCESS BOXES MUST BE SHOWN,
AND HOW ALL MECHANICAL EQUIPMENT IS SCREENED
WHETHER IT IS MOUNTED ON THE ROOF
OR ON THE GROUND.
.
2. REFER TO SHEET C3.1 ALL ABOVE GRADE PARKING
SPACE SIGNSMUST HAVE THE BOTTOM EDGE OF THE
SIGN NO LOWER THAN 4 FEET NO HIGHER THAN 7 FEET
IN ACCORDANCE WITH VCC 2012SECTION 1106.8.
CURRENT PLANS SHOW BOTTOM EDGE LESS THAN 4 FEET.
*****************************************************
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : RESIDENCE INN HOTEL
CASE NUMBER : 17PR0264
LATEST PLAN DATE : 6/22/17
RECEIVED DATE : 7/3/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 7/18/17
ADDRESS : PENDING
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY.
2. FYI: WHEN THE ADDRESS FOR THE HOTEL IS ASSIGNED, IT
WILL BE ADDRESSED OFF OF JOHNSTON WILLIS DR.
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : RESIDENCE INN HOTEL
CASE NUMBER : 17PR0264
LATEST PLAN DATE : 11/16/17
RECEIVED DATE : 11/18/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 11/30/17
ADDRESS : 1350 JOHNSTON WILLIS DR 23235
STATUS : APPROVED
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : RESIDENCE INN HOTEL
CASE NUMBER : 17PR0264
LATEST PLAN DATE : 2/20/18
RECEIVED DATE : 2/28/18
SUBMITTAL NUMBER : 3
REVIEW DATE : 3/12/18
ADDRESS : 1350 JOHNSTON WILLIS DR 23235
STATUS : APPROVED
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : RESIDENCE INN HOTEL
CASE NUMBER : 17PR0264
LATEST PLAN DATE : 4/25/18
RECEIVED DATE : 5/3/18
SUBMITTAL NUMBER : 4
REVIEW DATE : 5/17/18
ADDRESS : 1350 JOHNSTON WILLIS DR 23235
STATUS : APPROVED
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : RESIDENCE INN HOTEL
CASE NUMBER : 17PR0264
LATEST PLAN DATE : 5/30/18
RECEIVED DATE : 6/7/18
SUBMITTAL NUMBER : 5
REVIEW DATE : 6/25/18
ADDRESS : 1350 JOHNSTON WILLIS DR 23235
STATUS : APPROVED
==========================================================
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
ADDRESS: 10701 CENTER VIEW DRIVE
LATEST PLAN DATE: 6/22/1
DEPT. REC'D. DATE: 6/30/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 7/6/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. RELOCATE THE FDC TO AN AREA NEAR THE HYDRANT ON
THE SOUTHWEST CORNER OF THE PROPERTY.
2. THE MINIMUM REQUIRED FIRE FLOW FOR PROTECTION PURPOSES
SHALL BE SHOWN ON THE SUBMITTED DRAWINGS. REFER TO THE
INTERNATIONAL FIRE CODE (2012), SECTION B105 AND THE
COUNTY CODE OF CHESTERFIELD FOR EXCEPTIONS ALLOWED FOR
SPRINKLER PROTECTED BUILDINGS
REFER TO THE INTERNATIONAL FIRE CODE (2012) -
SECTION B104, B104.1, B104.2 AND B104.3 FOR THE CALCULATIO
PROCESS AND ALLOWANCES. THE CORRECT FORMAT AND CALCULATION
SHEET CAN BE OBTAINED VIA THE INTERNET AT
CHESTERFIELD COUNTY- CHESTERFIELD FIRE AND EMS - DIVISION
OF FIRE AND LIFE SAFETY
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
3. ON THE UTILITY PLAN, SHOW THE GATE VALVE AND BOX AT THE
END OF THE UTILITY EASEMENT SERVING THE FIRE PROTECTION
UNDERGROUND WITH INTERIOR BACKFLOW PREVENTER.
4. PROVIDE THE DETAILS FOR THE AUTOMATIC SPRINKLER SYSTEM
RUN-IN AND STUB UP, INCLUDING ALL APPLICABLE NOTES. SEE:
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
FOR A COPY OF THE DETAILS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
ADDRESS: 10701 CENTER VIEW DRIVE
LATEST PLAN DATE: 11/16/17
DEPT. REC'D. DATE: 11/27/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 11/27/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. . PROVIDE THE DETAILS FOR THE AUTOMATIC SPRINKLER SYSTE
RUN-IN AND STUB UP, INCLUDING ALL APPLICABLE NOTES. SEE:
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
FOR A COPY OF THE DETAILS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
ADDRESS: 10701 CENTER VIEW DRIVE
LATEST PLAN DATE: 2/20/18
DEPT. REC'D. DATE: 2/23/18
SUBMITTAL NUMBER: 3RD REVIEW
REVIEW DATE: 3/12/18
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
ADDRESS: 10701 CENTER VIEW DRIVE
LATEST PLAN DATE: 4/25/18
DEPT. REC'D. DATE: 5/1/18
SUBMITTAL NUMBER: 4TH REVIEW
REVIEW DATE: 5/2/18
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: RESIDENCE INN HOTEL
SITE PLAN NUMBER: 17PR0264
ADDRESS: 10701 CENTER VIEW DRIVE
LATEST PLAN DATE: 5/30/18
DEPT. REC'D. DATE: 6/5/18
SUBMITTAL NUMBER: 5TH REVIEW
REVIEW DATE: 6/7/18
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.

Modify comments view for case # 17PR0264



Go to Case Selection Form or Go to Project List