CASE NO: 17PR0255 STATUS: PENDING APPROVAL
PROJECT NAME: GREENWICH WALK AT FO - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: MULTI-FAMILY
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 01 09/15/17 10/06/17 ******** ********
ENVIR.ENGR.-: 01 09/15/17 10/06/17 ******** ********
FIRE DEPT.--: 01 09/15/17 10/06/17 COMPLETE 09/22/17 AWB 717-6167
MAPPING/GIS-: 01 09/15/17 10/06/17 COMPLETE 10/10/17 AMJ 768-7549
PLANNING----: 01 09/15/17 10/06/17 COMPLETE 10/12/17 JJD 717-6191
TRANSPORT.--: 01 09/15/17 10/06/17 COMPLETE 09/19/17 SJA 751-4461
UTIL.PLAN.--: 01 09/15/17 10/06/17 ******** ********
UTILITIES---: 01 09/15/17 10/06/17 AMENDED* 09/27/17
UTIL.R.O.W.-: 01 09/15/17 10/06/17 ******** ********
VDOT--------: 01 09/15/17 10/06/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E./748-1338
NAME OF PLAN : GREENWICH WALK AT FOX CREEK PH 4
ADDRESS : 7311 OTTERDALE RD
SUBMISSION DATE : 6/7/16
PLAN DATED : 6/5/17
REVIEW DATE : 6/19/17
SITE PLAN NO. : 17PR0255
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. UTILITIES PROJECT NUMBER 17-0117 SHALL BE PLACED ON
THE LOWER RIGHT HAND CORNER OF EACH SHEET.
2. PLEASE PUT UTILITIES CONTACT MIKE LARSON, P.E. 748-
1338, LARSONM@CHESTERFIELD.GOV ON THE COVER SHEET.
3. PLEASE INDICATE THAT ALL WATER AND SEWER ITEMS ARE
PUBLIC ON THE COVER SHEET
4. SHEET C3.0 SHOWS THE WATER STUBS THAT WILL SERVE UNITS
21-238 AS 8". 6" WATER LINE IS APPROPRIATE FOR THESE STUB
AS THERE ARE NO FIRE HYDRANTS.
5. SHEET C3.0 SHOWS AN 8" X 8" TEE FOR THE LINE THAT WILL
*RVE UNITS 248-257. CONSIDER PLACING A HYDRANT ON THE 8"
NE AND THEN A 6" X 6" TEE TO SERVE THOSE UNITS.
6. RELOCATE THE TAPS FOR WATER SERVICE FOR UNIT 192 AND 1
AWAY FROM THE TEE AND ENSURE THE METER BOX IS NOT ON
TOP OF THE STORM PIPE
7. MOVE THE METER BOX FOR UNIT 240 SO THAT IT IS EQUIDIST
T*TO THE FUTURE DRIVEWAYS.
8. THE METER BOXES FOR UNITS 259 AND 260 NEED TO BE DUCT
E*IRON BOXES AS THEY ARE SUBJECT TO UNINTENTIONAL TRAFFIC.
9. LABEL CITORY WAY ON SHEET C3.2.
10. RATHER THAN HAVING TWO COPPER STUBS ON CITORY WAY NE
HALLOWELL RIDGE, CONSIDER LEAVING A SLEEVE FOR PRIVATE IR
GATION LINES UNDER THE PAVEMENT. THESE MAY BE PERMITTED B
VDOT THROUGH THE LU-IR PERMIT.
11. IF POSSIBLE, RELOCATE THE HYDRANT NEAR STA 18+70 TO T
HIGH POINT AT CITORY WAY AND HALLOWELL RIDGE SO THAT
THE AIR RELEASE VALVE CAN BE ELIMINATED.
12. A BEND MAY BE NEEDED ON HALLOWELL RIDGE IN CURVE C2,
L*ASE VERIFY THE RADIUS.
13. ENSURE THAT DESIGN FOR MH 24 MATCHES THE ACTUAL AS-B
LT INFORMATION THAT WAS FIELD ADJUSTED. INCLUDE A NOTE TH
THE MANHOLE IS TO BE CORE-DRILLED WITH A KOR-N-SEAL GASKE
INSTALLED.
14. PROVIDE A NOTE THAT ALL WATER METERS SHALL BE A MINIM
*OF 3 FT BEHIND THE SIDEWALK.
15. SINCE THERE ARE NO PROPOSED SERVICES ON THE STUBOUTS
R MH 33, 34, AND 35, WE WILL ALLOW THE STUBOUTS TO BE INST
LED WITHOUT A MANHOLE PROVIDED THAT THE PLUG IS
CALLED OUT AS AN M.J. PLUG. PROVIDE PROFILES FOR EACH FUT
E SEWER LINE UP TO THE FUTURE MANHOLE AND CALL OUT THE INV
T AT THE PROPOSED M.J. PLUG.
16. SHOW THE 6" PVC SLEEVE ON THE HALLOWELL RIDGE PROFILE
*
17. USE VERTICAL BENDS WITH RESTRAINED JOINTS TO GO UNDER
*E STORM PIPES.
18. ADJUST THE LOCATION OF THE PROPOSED VALVES AND HYDRAN
*EE SO THAT THE VALVES ARE NO MORE THAN 5 FT DEEP.
19. LABEL THE SIZE AND MATERIAL OF THE PROPOSED AND EXIST
G WATER LINES ON THE PROFIE. LABEL THE UTILITIES PROJECT
MBER ON THE EXISTING WATER LINES.
20. PLEASE BE ADVISED THAT THIS PROJECT WILL NOT BE
ACCEPTED INTO USE BY THE COUNTY UNTIL THE PHASE 1 AND PHAS
2 WATER AND SEWER ARE COMPLETE
21. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF MIKE LARSON
(LARSONM@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
22. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS).
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E./748-1338
NAME OF PLAN : GREENWICH WALK AT FOX CREEK PH 4
ADDRESS : 7311 OTTERDALE RD
SUBMISSION DATE : 6/7/16
PLAN DATED : 9/12/17
REVIEW DATE : 9/25/17
SITE PLAN NO. : 17PR0255
COMMENTS : 2ND REVIEW-NOT APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
1. PROVIDE PROFILES FOR THE THREE SEWER STUBOUTS WITH EXTE
IONS TO THE FUTURE MANHOLES SHOWN AS "PRELIMINARY".
2. SHOW A CURB STOP VALVE ON THE 2" COPPER STUBOUT.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: GREENWICH WALK AT FOX CREEK PHASE 4
SITE PLAN NUMBER: 17PR0255
LATEST PLAN DATE: 06/05/17
DEPT. REC'D. DATE: 06/08/17
SUBMITTAL NUMBER: ONE
REVIEW DATE: 06/12/17
RECOMMENDATION: SUBSTANTIAL APPROVAL
(COMPLETION OF VILLAGE SQUARE PKY)
PLAT PROCESSING: R/W DEDICATION FOR LOCAL ROADS
.
PRIOR TO ISSUANCE OF ANY BUILDING PERMITS FOR THIS PHASE,
VILLAGE SQUARE PKY PHASES I (08PR0289) & II (O8PR0290)
SHALL BE COMPLETED IN ACCORDANCE WITH APPROVED TRAN PHASIN
PLAN DATED 10/28/15 (RECEIVED & SIGNED BY CDOT ON 11/9/15)
.
SITE PLAN APPROVAL HAS BEEN PROVIDED FOR 138 UNITS.
TRANSPORTATION PHASING PLAN REQUIRES CONSTRUCTION OF
VILLAGE SQUARE PY, AS SHOWN ON REFERENCED SITE PLANS, PRIO
TO ISSUANCE OF CUMULATIVE TOTAL OF MORE THAN 100 UNITS.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: GREENWICH WALK AT FOX CREEK PHASE 4
SITE PLAN NUMBER: 17PR0255
LATEST PLAN DATE: 09/12/17
DEPT. REC'D. DATE: 09/18/17
SUBMITTAL NUMBER: TWO (DOPP)
REVIEW DATE: 06/12/17
RECOMMENDATION: SUBSTANTIAL APPROVAL
(COMPLETION OF VILLAGE SQUARE PKY)
PLAT PROCESSING: R/W DEDICATION FOR LOCAL ROADS
.
PRIOR TO ISSUANCE OF ANY BUILDING PERMITS FOR THIS PHASE,
VILLAGE SQUARE PKY PHASES I (08PR0289) & II (O8PR0290)
SHALL BE COMPLETED.
==========================================================
==========================================================
REVIEWER / PHONE #-----JEFF DOPP/717-6191
EMAIL------------------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN----------- GREENWICH WALK AT FOX CREEK PHASE
SITE PLAN NUMBER-------17PR0255
LATEST PLAN DATE------- 06/05/2017
DEPT. REC'D. DATE------ 06/062017
ACCEPTED FOR REVIEW - 06/07/2017
SUBMITTAL NUMBER-------ONE
REVIEW DATE------------ 07/05/17
RECOMMENDATION----NOT APPROVED
TABLE REVIEW----------- NO
LANDSCAPE PLAN STATUS- SEE COMMENTS
STREET TREE LANDSCAPE PLAN-REQUESTED
BUILDER BOOK POD LANDSCPAE PLAN: APPROVAL REQUIRED
PRIOR TO BUILDING PERMIT SUBMITTAL.
ARCHITECTURAL ELEVATIONS APPROVAL REQUIRED PRIOR TO
BUILDING PERMIT SUBMITTAL.
LIGHTING PLAN/CUTSHEETS--REQUESTED
IRRIGATION/HOSEBIB PLAN-APPROVAL REQUIRED PRIOR TO
BUILDING PERMIT SUBMITTAL.
REVIEW COMMENTS:
01. PUT A REVISION DATE ON THE RESUBMITTED
PLANS. RESUBMIT 12 FULL SETS & 1 COPY OF
THE SITE PLAN SHEET TO THE PLANNING
DEPARTMENT FOR YOUR NEXT REVIEW.
.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS
USING THE SPACE BELOW EACH COMMENT TO
DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED.
PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT
CAUSED BY STAFF REVIEW COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM #)
SUBMIT SIX COPIES OF RESPONSE TO COMMENTS
SO EACH DEPARTMENT HAS A COPY TO CONDUCT A
REVIEW. PLANS WILL NOT BE ACCEPTED FOR REVIEW
IF THIS IS NOT INCLUDED WITH RESUBMITTAL.
.
03. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER
17PR0255 IN THE LOWER RIGHT CORNER OF EACH SHEET.
.
04. THIS IS MULTI-FAMILY DEVELOPMENT AND MUST
PROVIDE FOR CLUSTER BOX MAL UNITS (CBU'S). SHOW
ON SITE PLAN.
.
05. SHEET C1.0: ADD ZONING CASE # 16SN0691
.
ABUTS UP AGAINST THE ADJACENT PROPERTY LINE OF LOT 17
SEC 2. OF PRIMROSE CREEK FURTHER AWAY FROM PROPERTY
LINE TO BE CONSISTENT WITH THE GENERAL LOCATION
SHOWN ON APPROVED EXHIBIT A FOR CASE 12SN0226.
.7. SHEET C6..0: GENERAL NOTES 36 IS MISSING
11. WIDEN THE PATH TO A MINIMUM OF 5' FEET TO IMPROVE
PATH FUNCTIONALITY.KING SPACES.
.
08. SHEET C1.1: SOME OF THE NUMBER OF UNITS SHOWN
ON THE CHART ARE INCORRECT. CORRECT THE NUMBER OF
ATTACHED UNITS FOR PHASE 1 AND PHASE 4 AND CORRECT
THE TOTAL UNITS FOR EACH PHASE AND TOTAL UNITS FOR ALL
ADA ACCESSIBLE.
.
09. CONDITION 3. ZONING CASE 12SN0226 REQUIRES A
WALKING TRAIL AS GENERALLY SHOWN ON EXHIBIT A OF THE
TEXTUAL STATEMENT PREPARED BY KOONTZ-BRYANT, DATED
10/8/2013. A PORTION OF THE REQUIRED TRAIL IS SHOWN
ON THE PLANS. HOWEVER, BECAUSE THE PROPERTY IS ZONED
R-MF, THE TRAIL REQUIRES SITE PLAN APPROVAL AND MUST BE
PART OF PHASE 4. PLEASE CLEARLY HATCH OUT THE LIMITS OF
PHASE 4 TO INCLUDE THE REQUIRED WALKING TRAIL.
.
10. PLEASE SHIFT LOCATION OF THE SECTION OF TRAIL THAT
SEC 2. OF PRIMROSE CREEK FURTHER AWAY FROM PROPERTY
LINE TO BE CONSISTENT WITH THE GENERAL LOCATION
SHOWN ON APPROVED EXHIBIT A FOR CASE 12SN0226.
.
11. WIDEN THE PATH TO A MINIMUM OF 5' FEET TO IMPROVE
PATH FUNCTIONALITY.
.
12. PLANS SHOW PATH WILL CONSIST OF GRAVEL. PROVIDE A
PROFILE FOR THE PATH SHOWING TYPE OF GRAVEL MATERIAL AND
DEPTH OF MATERIAL. PLANNING RECOMMENDS PATH
CONSIST OF STONE DUST. MAKE SURE PATH AND MATERIAL IS
ADA ACCESSIBLE.
EXTEND TO ADJACENT PROPERTIES.
.3. CONDITION 3. ZONING CASE 12SN0226 REQUIRES A
WALKING TRAIL AS GENERALLY SHOWN ON EXHIBIT A OF THE
TEXTUAL STATEMENT PREPARED BY KOONTZ-BRYANT, DATED
10/8/2013. A PORTION OF THE REQUIRED TRAIL IS SHOWN
ON THE PLANS. PLEASE BE AWARE THAT THE REMAINDER OF THE
TRAIL WILL NEED TO BE SHOWN AND INCLUDED WITH PHASE 5.
.
14. LABEL, DIMENSION AND SHOW THE REQUIRED 50' BUFFER
ADJACENT TO SEC 2. OF PRIMROSE CREEK AND IDENTIFY
THE REQUIRED PERIMETER LANDSCAPE REQUIREMENT ON ALL
LAYOUT AND UTILITY PLANS, EROSION, AND GRADING PLANS.
THE 50' BUFFER IS REQUIRED TO BE INCLUDED WITH THE SITE PL
. FOR THE 50' BUFFER ADJACENT TO PRIMROSE
@ FOXCREEK LABEL AS "1.5 X PERIMETER LANDSCAPE C".
.
15. PER SEC. 19.1-262.B, USES IN BUFFERS ARE LIMITED TO
LANDSCAPING AND SCREENING, SIGNS, SECURITY FENCING, UTILIT
THAT RUN PERPENDICULAR THROUGH THE BUFFER, PEDESTRIAN
WALKWAYS, AND SIMILAR USES AS APPROVED THROUGH SITE OR
SCHEMATIC PLAN REVIEW.
.
16. PER SEC. 19-668, PEDESTRIAN ACCESS SHALL
CONNECT USES WITHIN INDIVIDUAL DEVELOPMENTS AND
EXTEND TO ADJACENT PROPERTIES.
.
17. PER TABLE 19.1-236.A, NOTE 4, PARKING WITHIN A GARAGE
OR COVERED SPACE MAY BE COUNTED TOWARD PARKING
REQUIREMENTS FOR RESIDENTIAL USES. CONVERSION OF
SUCH GARAGE OR COVERED SPACE IS PROHIBITED
.
18. SHEET C3.1: DIMENSION DISTANCE BETWEEN UNITS 198 &
199.
.
19. SHOW HORIZONTAL SCALE ON EACH SHEET INCLUDING
A GRAPHIC SCALE.
.
20. GHOST LINE ALL SIDEWALKS APPROVED UNDER DIFFERENT PHAS
.
21. SHEET C3.2: LABEL AND DIMENSION THE DISTANCE BETWEEN
THE UNIT FOUNDATION AND WALKWAY FOR UNITS 212, 213, 216, 2
SHOW THERE IS A MINIMUM 4' FOOT SEPARATION TO INSTALL
REQUIRED PLANTING BEDS.
.
22. SHEET C3.2: LABEL AND DIMENSION THE DISTANCE BETWEEN
THE UNIT FOUNDATION AND WALKWAY FOR UNITS 204 AND 210 TO
SHOW THERE IS A MINIMUM 4' FOOT SEPARATION TO INSTALL
REQUIRED PLANTING BEDS.
23. CONDITION OF ZONING REQUIRES STREET TREES SHALL
BE PLANTED ALONG BOTH SIDES OF ALL STREETS. UNITS
205-208 ARE NOT CONDUCIVE TO PLANTING TREES AND
CONFLICT WITH THE PROPOSED STORM WATER SEWER LINE.
PLANTINGS ARE REQUIRED TO BE SETBACK A MINIMUM OF
8' FEET FROM STORM SEWER LINE. REVISE PLANS TO
MEET ZONING REQUIREMENT TO PROVIDE FOR STREET TREES.
.
24. PROVIDE A PEDESTRIAN CROSS-WALK ACROSS HALLOWELL
RIDGE TO CONNECT REQUIRED TRAIL AND IMPROVE PEDESTRIAN
SAFETY. MAKE SURE CROSSWALK IS DESIGNED NOT TO BE IN
THE PATH OF DROP INLETS SHOWN ON PLAN. PROVIDE CG-12
ON BOTH SIDES OF ROAD.
.
25. SHOW CONCREATE MARKING FOR SIDEWALK IN-BETWEEN
DRIVEWAYS SERVING UNITS 219 & 220.
.
26. DESIGN GRADING PLAN TO BE CONDUCIVE TO
THE INSTALLATION OF A 4' FOOT WIDE PLANTING BED MEASURED
FROM THE FRONT AND CORNER SIDE FOUNDATIONS OF ALL SIDES
FACING A STREET.
.
27. TO ENSURE ADEQUATE ACCESS IS PROVIDED FOR EACH
COVERED PARKING SPACE, A 16' WIDE DOUBLE DOOR WILL BE
REQUIRED FOR ALL UNITS WITH TWO COVERED PARKING SPACES.
IF ONLY ONE COVERED PARKING SPACE IS PROVIDED AT MINIMUM
A 9' FOOT WIDE GARAGE DOOR WILL NEED TO BE PROVIDED.
.
28. ANY UNCOVERED PARKING SPACE WILL NEED TO BE SHOWN
DIMENSIONED ON THE SITE PLAN AND SHALL HAVE A MINIMUM
WIDTH OF NINE FEET AND A MINIMUM DEPTH OF 18 FEET.
THE LOCATION OF EXTERIOR PARKING SPACES MAY NOT BLOCK
ACCESS TO ANY COVERED PARKING SPACES AND MAY NOT
ENCROACH INTO SHARED DRIVEWAY AISLES. SEC. 19-514(A)
.
29. PER SEC. 19-509(C), PARKING WITHIN A GARAGE
OR COVERED SPACE MAY BE COUNTED TOWARD PARKING
REQUIREMENTS FOR RESIDENTIAL USES. CONVERSION OF
SUCH GARAGE OR COVERED SPACE IS PROHIBITED UNLESS
SUFFICIENT OFF-STREET PARKING IS PROVIDED.
.
30. PER SEC. 19-510(A) (3), PARKING OF RECREATIONAL
EQUIPMENT IS PROHIBITED IN R-TH, R-MF, AND
TND DISTRICTS UNLESS A COMMON STORAGE AREA IS
PROVIDED THAT IS SCREENED FROM VIEW, AND SPACES
ARE NOT COUNTED AS ANY OF THE TOTAL REQUIRED PARKING
FOR THE OTHER USES ON SITE.
..
PROPOSED TREES AND SHRUBS WITH THE PLAN SIZES, PLANT ING
SPECIES, COUNTY REQUIRED NOTES AND DETAILS AND ANY SPECIFI
REQUIREMENTS FOR THE SITE. (CL D.4)
32. SUBMIT DOCUMENTS DEMONSTRATING COMPLIANCE WITH
CONDITION 7 OF CASE 12SN0226 PERTAINING TO THE VIRGINIA
CONDOMINIUM ACT AND THE CONDOMINIUM ASSOCIATION
RESPONSIBILITIES OF MAINTENANCE OF ALL COMMON AREAS,
ARCHITECTURAL REVIEW COMMITTEE. THE CONDOMINIUM
ASSOCIATION SHALL BE PART OF THE FOXCREEK HOMEOWNER'S
ASSOCIATION. ALSO, ENSURE HOA DOCUMENTS MEET ALL
REQUIREMENTS OF ORDINANCE SEC. 19-559.
.
33. SUBMIT THE STREET TREE LANDSCAPE PLANS
TO THE PLANNING DEPARTMENT IN ACCORDANCE WITH
CONDITIONS OF CASE 12SN0226 AND THE COUNTY ORDINANCE.
(REF. COUNTY ORDINANCE AND TEXTUAL STATEMENT DATED
NOVEMBER 15, 2013 APPROVED UNDER CASE 12SN0226).
SHOW ALL SITE IMPROVEMENTS INCLUDING UTILITIES, STORM SEWE
EASEMENTS AND RIGHTS-OF-WAY, FIRE HYDRANT AND VAULT LOCATI
AND SITE LIGHTING (IF SITE IS TO BE LIT). THIS PLAN MUST B
TO SCALE. THE PLAN MUST INCLUDE DIMENSIONS OF PERIMETER
YARDS AND BUFFERS AND APPROPRIATE LANDSCAPE REQUIREMENTS F
EACH YARD OR BUFFER, BMP AREAS AND ANY OTHER LANDSCAPE
REQUIREMENTS. THE PLAN MUST SHOW THE LAYOUT OF EXISTING AN
PROPOSED TREES AND SHRUBS WITH THE PLAN SIZES, PLANT
SPECIES, COUNTY REQUIRED NOTES AND DETAILS AND ANY SPECIFI
REQUIREMENTS FOR THE SITE. (CL D.4)
.
34. (NOTE: REFERENCE SEC. C - SETBACKS AND BUFFERS - REVIE
COMMENT 1 PRIOR TO DEVELOPING THE LANDSCAPE PLAN. COUNTY
STANDARDS FOR LANDSCAPING SHALL BE LABELED ON THE SITE PLA
WITHIN THE SETBACK AND BUFFER AREAS.)
.
1. PER SEC. 19-264(A), THE LANDSCAPE PLAN SHALL
IDENTIFY THE STATE REGISTERED LANDSCAPE ARCHITECT,
NURSERYMAN, OR LANDSCAPE DESIGNER PREPARING THE
LANDSCAPE PLAN.
.
2. PER SEC. 19-517(A) AND (B), AT LEAST A CONCEPTUAL
LANDSCAPING PLAN SHALL BE APPROVED PRIOR TO RELEASE
OF FINAL SITE PLAN APPROVAL. WHETHER THE PLAN
SUBMITTED IS A CONCEPTUAL OR DETAILED LANDSCAPE
PLAN, THE PLAN SHALL SHOW THE FOLLOWING:
.
A. ALL EASEMENTS AND RIGHTS OF WAY, FIRE HYDRANT LOCATIONS
AND SITE LIGHTING LOCATIONS. SHOW VDOT SIGHT LINES
FROM ENTRANCES.
B. WIDTH OF PERIMETER YARDS AND BUFFERS AND THE ORDINANCE
STANDARD FOR THE PLANTING OF EACH YARD AND/OR BUFFER -
SHOW SEPARATE TABULAR CALCULATION OF REQUIRED AND
PROPOSED PLANTINGS FOR EACH YARD AND/OR BUFFER.
C. SHOW CALCULATIONS FOR PLANTING OF INTERIOR PARKING LOT
AREAS (SEE SEC. D - PARKING - REVIEW COMMENTS 15-20).
D. SHOW BMP AREAS AND ADDRESS PER SEC. 19-518(I) IF REQUIR
O TREAT AS A VISUAL AMENITY.
E. IF A CONCEPTUAL PLAN IS SUBMITTED, SHOW ARRANGEMENT OF
ALL PLANTS AND IDENTIFY EACH AS LARGE OR SMALL DECIDUOUS
TREES, EVERGREEN TREES, MEDIUM SHRUBS, AND SMALL SHRUBS/
GROUNDCOVERS. THESE MAY BE KEYED TO A CONCEPTUAL
PLANT LIST SHOWING THESE PLANT TYPES AND THE QUANTITIES
OF EACH.
F. IF A DETAILED LANDSCAPE PLAN IS SUBMITTED, SPECIFY THE
PLANTS AND THEIR REQUIRED SIZES FOR EACH OF THE PLANT
TYPES REQUIRED PER SEC. 19-518(B).
G. SHOW ALL AREAS OF EXISTING TREES TO REMAIN AND CLEARLY
LABEL AS SUCH. SEE SEC. 19-518(D) REGARDING REQUIREMENTS
FOR TREE PRESERVATION.
1. ALL TREES WITHIN THE SETBACK FROM A PUBLIC RIGHT OF
WAY SHALL BE RETAINED UNLESS REMOVAL IS NECESSARY TO
ACCOMMODATE VEHICULAR ACCESS AND/OR UTILITIES THAT
RUN GENERALLY PERPENDICULAR THROUGH THE SETBACK.
THESE TREE SAVE AREAS SHALL BE SHOWN ON THE EROSION
2. HEALTHY EXISTING TREES MAY BE CREDITED TOWARD
PLANTING REQUIREMENTS SO LONG AS EXISTING VEGETATION
IS REASONABLY DISTRIBUTED THROUGHOUT THE LENGTH OF THE
SETBACK AREA.
3. REMOVAL OF EXISTING TREES WITHIN THE SETBACK OR
BUFFER WITHOUT WRITTEN APPROVAL FROM THE PLANNING
DEPARTMENT SHALL RESULT IN TWO TREES BEING PLANTING
FOR EACH TREE REMOVED
4. ANY EXISTING TREES IN SETBACKS THAT ARE APPROVED
FOR REMOVAL SHALL BE SHOWN AS SUCH ON THE EROSION
CONTROL, GRADING AND LANDSCAPE PLANS.
H. PER SEC. 19-518(C), THE LANDSCAPE DESIGN SHALL BE
REQUIRED TO PROVIDE A PROFESSIONALLY ACCEPTABLE
COMPOSITION AND MIX OF VEGETATION.
I. PER SEC. 19-518(C), DECORATIVE WALLS AND FENCES,
HAVING A MINIMUM HEIGHT OF 36 INCHES, MAY REDUCE
THE AMOUNT OF REQUIRED PLANT MATERIALS AS
DETERMINED AT TIME OF SITE PLAN OR SCHEMATIC APPROVAL.
J. PROVIDE STANDARD COUNTY LANDSCAPE NOTES ON DETAILED
LANDSCAPE PLAN
K. EACH REVIEW OF DETAILED LANDSCAPE PLANS AFTER
APPROVAL OF THE SITE PLAN INCURS A RESUBMITTAL FEE
AND IS TRACKED AS A SITE PLAN REVIEW UNTIL APPROVED.
APPROVAL MUST BE OBTAINED PRIOR TO TEMPORARY
OCCUPANCY OF THE BUILDING.
.
OCCUPANCY OF THE BUILDING.
.
.
35. REGARDING THE 50' BUFFER ALONG THE NORTHERN P/L,
REQUIRES THE LANDSCAPE PLAN IDENTIFY AND SHOW LOCATION
OF ALL EXISTING HEALTHY PLANTINGS THAT ARE BE CREDITED T
TOWARDS THE REQUIRED NUMBER OF PLANTINGS WITHIN THE
50' BUFFER. TO SIMPLIFY YOU MAY ADD THE FOLLOWING
NOTE ON LANDSCAPE, SITE LAYOUT AND GRADING PLAN:
"AT TIME OF COMPLETION OF CLEARING AND GRADING,
FIXTURE SHOWN ON THE PLAN.D AND DEVELOPER WILL
CONTACT THE PLANNING DEPARTMENT FOR A BUFFER
INSPECTION. IF THE QUANTITIES OF HEALTHY PLANTINGS
ARE INSUFFICIENT AND THE PLANTINGS ARE NOT REASONABLY
DISTRIBUTED THROUGHOUT EACH BUFFER, A LANDSCAPE
PLAN WILL BE PREPARED AND SUBMITTED IN ACCORDANCE
WITH SECTION 19.1-27 E, REQUIRING THE LANDSCAPE
PLAN TO BE PREPARED BY A STATE REGISTERED
LANDSCAPE ARCHITECT OR NURSERYMAN. CERTIFICATE
OF OCCUPANCY WILL NOT BE ISSUED UNTIL LANDSCAPE
PLAN IS APPROVED AND PLANTINGS ARE INSTALLED.
.
36. PER REVIEWER'S EMAIL CORRESPONDENCE WITH
ENGINEER DATED 4/15/15, MANUFACTURER CUT
SHEETS FOR BUILDING MOUNTED LIGHTS ATTACHED TO
DWELLING UNITS WILL NOT BE REQUIRED UNTIL TIME
OF BUILDING PERMIT. HOWEVER, IN CONJUNCTION
WITH SITE PLAN APPROVAL, MANUFACTURER CUT SHEETS
AND A LIGHTING PLAN ARE REQUIRED FOR PROPOSED
STREET LIGHTS AND YARD LIGHTS. PER SEC. 19-508.3,
SHOW ON THE LANDSCAPE PLAN OR ADDITIONALLY ON
A SEPARATE LIGHTING PLAN THE LOCATION OF ALL EXTERIOR
SITE LIGHTING MOUNTED ON POLES, OR ON THE GROUND
AND HAVE THEM KEYED TO CUT SHEETS FOR EACH LIGHT
FIXTURE SHOWN ON THE PLAN.
.
37. INDICATE PROPOSED SITE AREA LIGHTING ON THE
LANDSCAPE PLAN. PROPOSE LANDSCAPING AND LIGHTING
LOCATIONS SHALL BE COORDINATED TO PREVENT PLANT
MATERIAL AT MATURE SIZES FROM INTERFERING WITH
LIGHT FIXTURES. (REF SEC 19-571 (B)
.
38. PROVIDE CATALOGUE CUT SHEETS FOR EACH EXTERIOR
LIGHT FIXTURE PROPOSED.
.
39. PER SEC. 19-508.3, UNLESS A PROJECT IS APPROVED
FOR ORNAMENTAL PEDESTRIAN-STYLE LIGHTING, ALL LIGHT
FIXTURES SHALL BE OF A DIRECTIONAL TYPE THAT SHIELDS
THE LIGHT SOURCE FROM DIRECT VIEW FROM ANY
ADJOINING, A, R, R-TH, MH, TND, OR R-MF DISTRICT
OR PUBLIC RIGHT-OF -WAY.
.
40. PROPERTY CONDITION REQUIRES THAT OPEN SPACE RECREATION
BE PROVIDED THROUGHOUT THE DEVELOPMENT INDICATE THESE
AREAS ON THE SITE PLANS.
..
41. NOTE: SHEETS C1.1 C1.3, C1.4, C3.0:
PER REVIEWER'S DISCUSSION WITH GREG ALLEN AND
OF THE 50' BUFFER ADJACENT TO OTTERDALE ROAD WILL BE
FINALIZED WITH THE SUBMITTAL OF PHASE SIX TO ALLOW
THE DEVELOPER TO WORK WITH CDOT ON
TRANSPORTATION REQUIREMENTS.
.
42. NOTE: PER GREG ALLEN'S EMAIL DATED NOVEMBER
4, 2015, THE IRRIGATION COVERAGE PLAN MAY BE
SUBMITTED AT TIME OF BUILDING PERMIT SUBMITTAL FOR
EACH PHASE. PLEASE ENSURE THE IRRIGATION PLAN IS
DESIGNED TO MEET BOTH ORDINANCE REQUIREMENTS AND
THE TEXTUAL STATEMENT DATED NOVEMBER 15, 2013
APPROVED UNDER CASE 12SN0226) REQUIRING ALL FRONT
YARDS TO BE SODDED AND IRRIGATED. INSURE WATER INFORMATION
IS SUPPLIED ON UTILITY DEPARTMENT METER SIZING FORMS.
.
43. NOTE: NO BUILDING PERMIT SHALL BE RELEASED
UNTIL FULL SITE PLAN APPROVAL IS GRANTED AND IRRIGATION
COVERAGE AND POD LANDSCAPE PLANS ARE APPROVED.
.
44. NOTE: PER JEFF DOPP'S EMAILS DATED 1/27/16, &
12/14/16. THE BUILDERS BOOK LANDSCAPE POD PLANS
MAY BE SUBMITTED FOR REVIEW AT TIME OF BUILDING PERMIT
SUBMITTAL. LANDSCAPE POD PLANS WILL NEED TO BE
DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF
THE CHESTERFIELD COUNTY ZONING ORDINANCE AND THE
TEXTUAL STATEMENT APPROVED WITH ZONING CASE
12SN0226. ALSO, PLEASE SEE PREVIOUS REVIEW
COMMENTS.
.
45. NOTE: PER JEFF DOPP'S EMAIL DATED 12/14/16,
SITE PLAN APPROVAL LETTER WILL INCLUDE A CONDITION
REQUIRING THAT ARCHITECTURAL ELEVATIONS SHALL BE
SUBMITTED TO AND APPROVED BY PLANNING PRIOR TO
BUILDING PERMIT SUBMITTAL.
.
46. PER SEC. 19.1-248.B., A FORM OF SURETY SUCH AS A
PERFORMANCE BOND IN AN AMOUNT EQUAL TO 50 PERCENT
OF THE INITIAL INSTALLATION COST OF THE LANDSCAPING
SHALL BE SUBMITTED TO THE PLANNING DEPARTMENT PRIOR TO
THE PLANNING DEPARTMENT'S APPROVAL OF THE OCCUPANCY
PERMIT OR CERTIFICATE OF COMPLETION. WITHIN A YEAR OF
INSTALLATION AND PRIOR TO RELEASE OF THE BOND, THE
PLANNING DEPARTMENT SHALL INSPECT THE LANDSCAPING.
ANY PLANTS MISSING, DEAD, OR IN POOR CONDITION SHALL
BE REPLACED BY THE OWNER OR CONTRACTOR.
##########################################################
##########################################################
REVIEWER / PHONE #-----JEFF DOPP/717-6191
EMAIL------------------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN----------- GREENWICH WALK AT FOX CREEK PHASE
SITE PLAN NUMBER-------17PR0255
LATEST PLAN DATE------09/12/2017
DEPT. REC'D. DATE------ 09/15/2017
ACCEPTED FOR REVIEW - 09/15/2017
SUBMITTAL NUMBER------TWO
REVIEW DATE------------ 10/06/2017
RECOMMENDATION----NOT APPROVED
TABLE REVIEW----------- NO
LANDSCAPE PLAN STATUS- SEE COMMENTS
STREET TREE LANDSCAPE PLAN - SEE COMMENT
BUILDER BOOK POD LANDSCPAE PLAN: APPROVAL REQUIRED
PRIOR TO BUILDING PERMIT SUBMITTAL.
ARCHITECTURAL ELEVATIONS APPROVAL REQUIRED PRIOR TO
BUILDING PERMIT SUBMITTAL.
LIGHTING PLAN/CUTSHEETS-2ND REQUEST
IRRIGATION/HOSEBIB PLAN-APPROVAL REQUIRED PRIOR TO
BUILDING PERMIT SUBMITTAL.
REVIEW COMMENTS:
.
01. PUT A REVISION DATE ON THE RESUBMITTED
PLANS. RESUBMIT 12 FULL SETS & 1 COPY OF
THE SITE PLAN SHEET TO THE PLANNING
DEPARTMENT FOR YOUR NEXT REVIEW.
.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS
USING THE SPACE BELOW EACH COMMENT TO
DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED.
PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT
CAUSED BY STAFF REVIEW COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM #)
SUBMIT SIX COPIES OF RESPONSE TO COMMENTS
SO, EACH DEPARTMENT HAS A COPY TO CONDUCT A
REVIEW. PLANS WILL NOT BE ACCEPTED FOR REVIEW
IF THIS IS NOT INCLUDED WITH RESUBMITTAL.
.
03. THIS IS MULTI-FAMILY DEVELOPMENT AND MUST
PROVIDE FOR CLUSTER BOX MAIL UNITS (CBU'S). SHOW
ON SITE PLAN.
.
04. THE REQUIRED 50' BUFFER ADJACENT TO SEC 2.
PRIMROSE CREEK IS INCORRECTLY LABELED "50' SETBACK".
REVISE ALL SHEETS AND IDENTIFY AS "50' BUFFER" WITH
PERIMETER 1.5 C LANDSCAPING."
.
05. THE 50' BUFFER ADJACENT TO PRIMROSE @ FOXCREEK
IS A CONDITION OF ZONING AND REQUIRED TO BE INCLUDED
AS PART OF THE SITE PLAN REVIEW. SHEET C1.12 DOES NOT
SHOW THE BUFFER WITHIN THE LIMITS OF PHASE 4. SHOW THE
50' BUFFER WITHIN THE LIMITS OF PHASE 4. IF BUFFER WILL BE
INCLUDED IN A DIFFERENT PHASE PLEASE CONTACT JEFF DOPP
TO DISCUSS PRIOR TO RESUBMITTAL.
.
06. THE 50' BUFFER IS REQUIRED TO BE PLANTED WITH PERIMETE
1.5 C LANDSCAPING. PLEASE VERIFY THE EXISTING VEGETATION
MEETS THIS REQUIREMENT. IF NOT, PLEASE SUBMIT A LANDSCAPE
PLAN.
.
07. SHEET C1.11: REVISE OPEN SPACE TO INCLUDE 50'
BUFFER. BUFFER MAINTENANCE WILL BE THE RESPONSIBILITY
OF THE HOA FOR GREENWICH WALK AT FOX CREEK.
.
08. SHEETS C3.1 & C3.2: GHOST LINE ALL SIDEWALKS
APPROVED UNDER DIFFERENT PHASES.
.
09. SHEETS L1.1 & C3.2 RESPONSE TO PREVIOUS
COMMENT 23 NOT TO INSTALL STREET TREES VIOLATES
ZONING CONDITIONS. CONDITION OF ZONING REQUIRES
STREET TREES SHALL BE PLANTED ALONG BOTH SIDES OF
ALL STREETS AND ONE FLOWERING TREE REQUIRED IN
EACH FRONT YARD OF ALL UNITS. UNITS 205-208 ARE
NOT CONDUCIVE TO PLANTING TREES AND CONFLICT WITH
THE PROPOSED STORM WATER SEWER LINE. PLANTINGS
ARE REQUIRED TO BE SETBACK A MINIMUM OF 8' FEET
FROM STORM SEWER LINE. SHIFT LOCATION OF STORM
SEWER INLET AND PIPES TO ACCOMMODATE REQUIRED
PLANTINGS.
.
10. SUBMIT DOCUMENTS DEMONSTRATING COMPLIANCE WITH
CONDITION 7 OF CASE 12SN0226 PERTAINING TO THE VIRGINIA
CONDOMINIUM ACT AND THE CONDOMINIUM ASSOCIATION
RESPONSIBILITIES OF MAINTENANCE OF ALL COMMON AREAS,
ARCHITECTURAL REVIEW COMMITTEE. THE CONDOMINIUM
ASSOCIATION SHALL BE PART OF THE FOXCREEK HOMEOWNER'S
ASSOCIATION. ALSO, ENSURE HOA DOCUMENTS MEET ALL
REQUIREMENTS OF ORDINANCE SEC. 19-559.
.
11. SHEET C1.12: THE PUBLIC ROADS ARE LABELED "COMMON
AREA". THE ENTIRE PROJECT MINUS PUBLIC
ROADS AND LOCATION OF UNITS NEEDS TO BE IDENTIFIED AND
LABELED "COMMON AREA & OPEN SPACE" TO AVOID
ANY CONFUSION OF THE HOA RESPONSIBILITIES TO
MAINTAIN.
.
12. REVISE ALL NOTES THAT REFERENCE THE HOA'S
RESPONSIBILITY TO MAINTAIN COMMON AREAS AND
REVISE TO INCLUDE HOA IS RESPONSIBLE FOR ALL
COMMON AREAS AND OPEN SPACE WITHIN THE LIMITS
OF ALL PHASES WITHIN THE OVERALL PROJECT.
.
13. PER REVIEWER'S EMAIL CORRESPONDENCE WITH
ENGINEER DATED 4/15/15, MANUFACTURER CUT
SHEETS FOR BUILDING MOUNTED LIGHTS ATTACHED TO
DWELLING UNITS WILL NOT BE REQUIRED UNTIL TIME
OF BUILDING PERMIT. HOWEVER, IN CONJUNCTION
WITH SITE PLAN APPROVAL, MANUFACTURER CUT SHEETS
AND A LIGHTING PLAN ARE REQUIRED FOR PROPOSED
STREET LIGHTS AND YARD LIGHTS. PER SEC. 19-508.3,
SHOW ON THE LANDSCAPE PLAN OR ADDITIONALLY ON
A SEPARATE LIGHTING PLAN THE LOCATION OF ALL EXTERIOR
SITE LIGHTING MOUNTED ON POLES, OR ON THE GROUND
AND HAVE THEM KEYED TO CUT SHEETS FOR EACH LIGHT
FIXTURE SHOWN ON THE PLAN.
.
14. INDICATE PROPOSED SITE AREA LIGHTING ON THE
LANDSCAPE PLAN. PROPOSE LANDSCAPING AND LIGHTING
LOCATIONS SHALL BE COORDINATED TO PREVENT PLANT
MATERIAL AT MATURE SIZES FROM INTERFERING WITH
LIGHT FIXTURES. (REF SEC 19-571 (B)
.
15. PROVIDE CATALOGUE CUT SHEETS FOR EACH EXTERIOR
LIGHT FIXTURE PROPOSED.
.
16. IT HAS BEEN BROUGHT TO REVIEWER'S ATTENTION
THAT SUBSEQUENT HOA DOCUMENTS AND DECLARATIONS
HAVE BEEN RECORDED WITH THE CLERK OF THE CIRCUIT
COURT. THESE DOCUMENTS APPEAR TO HAVE BEEN RECORDED
WITHOUT BEING SUBMITTED TO THE COUNTY ATTORNEY AND
PLANNING FOR REVIEW. REVIEWER WILL DISCUSS THIS
WITH COUNTY ATTORNEY.
##################################################
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : GREENWICH WALK AT FOX CREEK, PH. 4
CASE NUMBER : 17PR0255
LATEST PLAN DATE : 6/5/17
RECEIVED DATE : 6/9/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 6/28/17
ADDRESS : PENDING
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. THE SITE ADDRESS IS INCORRECT IN THE SITE DATA.
THE CORRECT ADDRESS IS: 6800 DALES PONY DR.
2. SHOW THE LOCATION OF THE MAIL BOX KIOSKS OR CLUSTER
BOXES ON THE PLAN SHEET OR INDICATE IN WHICH BUILDING
THEY ARE LOCATED.
3. A STREET SIGN FEE OF $150 PER INTERSECTION (2) NEEDS
TO BE PAID TO ENVIRONMENTAL ENGINEERING PRIOR TO
SUBSTANTIAL APPROVAL SO THAT STREET SIGNS CAN BE
MANUFACTURED. PAYMENT SHOULD BE MADE OUT TO "TREASURER,
CHESTERFIELD COUNTY" AND SUBMITTED TO CAROLE CLIBORNE IN
ENVIRONMENTAL ENGINEERING AND REFERENCED TO SITE PLAN
NUMBER 17PR0255.
==========================================================
NUMBER 17PR0255.==========================================
==========================================================
REVIEWER : AMY JOHANSON (N) 768-7549
PROJECT NAME : GREENWICH WALK AT FOX CREEK, PH. 4
CASE NUMBER : 17PR0255
LATEST PLAN DATE : 9/12/17
RECEIVED DATE : 9/16/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 10/5/17
ADDRESS : PENDING
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. I DO NOT SEE WHERE THE FOLLOWING TWO COMMENTS HAVE
BEEN ADDRESSED. NO SHEET FOR THESE COMMENTS IN THE PACKET
2. SHOW THE LOCATION OF THE MAIL BOX KIOSKS OR CLUSTER
BOXES ON THE PLAN SHEET OR INDICATE IN WHICH BUILDING
THEY ARE LOCATED.
3. A STREET SIGN FEE OF $150 PER INTERSECTION (2) NEEDS
TO BE PAID TO ENVIRONMENTAL ENGINEERING PRIOR TO
SUBSTANTIAL APPROVAL SO THAT STREET SIGNS CAN BE
MANUFACTURED. PAYMENT SHOULD BE MADE OUT TO "TREASURER,
CHESTERFIELD COUNTY" AND SUBMITTED TO CAROLE CLIBORNE IN
ENVIRONMENTAL ENGINEERING AND REFERENCED TO SITE PLAN
NUMBER 17PR0255.
==========================================================
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: GREENWICH WALK AT FOX CREEK, PH. 4
SITE PLAN NUMBER: 17PR0255
ADDRESS: 7311 OTTERDALE ROAD
LATEST PLAN DATE: 6/5/17
DEPT. REC'D. DATE: 6/12/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 6/15/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: GREENWICH WALK AT FOX CREEK, PH. 4
SITE PLAN NUMBER: 17PR0255
ADDRESS: 7311 OTTERDALE ROAD
LATEST PLAN DATE: 9/12/17
DEPT. REC'D. DATE: 9/19/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 9/22/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.