All Site Plan Review Comments for Case # 17PR0240
Modify comments view for Case # 17PR0240

Go to Case Selection Form or Go to Project List

 
CASE NO: 17PR0240 STATUS: APPROVED - ADMIN
PROJECT NAME: HANCOCK VILLAGE PH I - LAST INTERNET UPDATE: 11/20/17
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 01 06/13/17 07/06/17 ******** ********
ENVIR.ENGR.-: 01 06/13/17 07/06/17 ******** ********
FIRE DEPT.--: 01 06/13/17 07/06/17 COMPLETE 06/23/17 AWB 717-6167
MAPPING/GIS-: 01 06/13/17 07/06/17 COMPLETE 07/06/17 AMJ 768-7549
PLANNING----: 01 06/13/17 07/06/17 COMPLETE 07/07/17 CH 717-6042
TRANSPORT.--: 01 06/13/17 07/06/17 COMPLETE 06/26/17 SJA 751-4461
UTIL.PLAN.--: 01 06/13/17 07/06/17 ******** ********
UTILITIES---: 01 06/13/17 07/06/17 AMENDED* 08/10/17 A U
UTIL.R.O.W.-: 01 06/13/17 07/06/17 ******** ********
VDOT--------: 01 06/13/17 07/06/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, P.E./(804)748-1343
NAME OF PLAN : HANCOCK VILLAGE PHASE II RETAIL
ADDRESS : 14601 HANCOCK VILLAGE STREET
SUBMISSION DATE : 5/3/17
PLAN DATED : 4/21/17
REVIEW DATE : 5/12/17
CASE NO. : 17PR0240
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. COUNTY PROJECT NUMBER 17-0092 SHALL BE PLACED ON THE
LOWER RIGHT HAND CORNER OF EACH SHEET.
2. ADD THE FOLLOWING UTILITIES CONTACT INFORMATION TO THE
COVER SHEET: ANNE URENDA, P.E., 804-748-1343,
URENDAA@CHESTERFIELD.GOV.
*
3. PLEASE INDICATE WHAT VERTICAL DATUM WAS USED. BE
ADVISED THAT CHESTERFIELD COUNTY REQUIRES NGVD 29;
THEREFORE, MAKE ANY NECESSARY CORRECTIONS AS APPLICABLE.
*
4. FIX THE NUMBERING OF THE GENERAL NOTES ON THE COVER
SHEET.
*
5. ON THE UTILITY MATERIALS QUANTITIES TABLE, LIST
SEWER ITEMS.
*
6. ON SHEET C2.1, PLEASE SHOW THE 2 EXISTING METER BOXES
(ONE THAT WILL BE USED FOR RETAIL A AND THE OTHER ONE
ACROSS FROM THE WATER VAULT). PLEASE ADD THE FOLLOWING
NOTE: "ALL SALVAGEABLE ITEMS ARE TO BE RETURNED TO
UTILITIES AT THE DISCRETION OF THE UTILITIES INSPECTOR."
*
7. SHOW THE LOCATION OF A MINIMUM OF ONE BENCHMARK ON
SHEET C5.0.
*
8. PROVIDE NUMBERING FOR THE EXISTING SANITARY MANHOLES
BASED UPON THE NUMBERS USED ON THE AS-BUILT PLANS, FOR
EXAMPLE MH-EX8, MH-EX9, ETC.
*
9. ADD A NOTE STATING THAT MANHOLE INSERTS ARE REQUIRED
FOR MH-EX8, MH-EX9, AND MH-EX10. THE APPROVED INSERT SHAL
BE PARSON PMI3SE WITH VALVE, GASKET, AND STRAP. PLEASE AD
THE INSERTS TO THE QUANTITIES LIST.
*
10. ADD A NOTE ABOUT CONNECTING THE PROPOSED LATERAL TO
MH-EX9 USING KOR-N-SEAL CONNECTOR.
*
11. TYPE K COPPER IS REQUIRED FOR THE PUBLIC PORTIONS OF
THE DOMESTIC SERVICE LINES; PLEASE LABEL OR ADD NOTE.
*
12. LABEL THE PORTION OF SEWER OUTSIDE OF THE EASEMENT AS
PRIVATE.
*
13. ADD A LINE TO SHOW THE PIPE BETWEEN THE EXISTING
WATERLINE AND THE EXISTING FIRE HYDRANT NEAR THE WATER
VAULT.
*
14. ON THE SERVICE LINE TO RETAIL B, THE UTILITIES
DEPARTMENT RECOMMENDS A SERVICE LINE ONE PIPE SIZE LARGER
THAN THE METER.
15. SHOW A NEW 8" X 8" TEE ON THE EXISTING FIRE LINE WHER
IT WILL REPLACE THE EXISTING 8" 90-DEGREE ELBOW.
16. LABEL THE SIZE AND MATERIAL OF THE RELOCATED FIRE
LINE.
17. LABEL THE PROPOSED FIRE LINES AS PRIVATE AND CALLOUT
* BENDS.
18. FOR THE 6" SEWER LATERAL WHICH SERVICES RETAIL B,
PLEASE ADD A CLEANOUT AT THE EASEMENT LINE AND ANOTHER
CLEANOUT AT THE 45-DEGREE BEND.
*
19. PLEASE SUBMIT A SITE UTILIZATION FORM. PLEASE NOTE
THAT IF ANY OF THE PROPOSED RETAIL STORES HAVE THE
POTENTIAL TO DISCHARGE A WASTE PRODUCT OTHER THAN NORMAL
SANITARY WASTEWATER, A PRIVATE SAMPLING MANHOLE SHALL BE
PROVIDED TO FACILITATE RANDOM SAMPLING.
*
20. A CURRENT START POINT FLOW TEST IS REQUIRED FOR THIS
SITE AND THE INFORMATION PROVIDED MUST BE ADDED TO THE
PLANS. PLEASE CONTACT TERRY MAPLES AT 804-751-4435 OR VIA
EMAIL AT MAPLEST@CHESTERFIELD.GOV FOR MORE INFORMATION.
*
21. IN THE STANDARD DETAIL DES-2, ADD 225 FEET AS THE
CONTOUR BELOW WHICH PRVS WILL BE REQUIRED. PLEASE BE
ADVISED THAT ALL SERVICE LINES INSTALLED BELOW THIS
ELEVATION WILL RESULT IN PRESSURE GREATER THAN 80 PSI.
DETERMINE IF THIS IS THE CASE AND ADD A PRV TO THE CUSTOME
SIDE OF THE METER IF NECESSARY.
*
22. PLEASE SUBMIT SEPARATE METER SIZING FORMS IN PDF
FORMAT USING THE ATTACHED METER SIZING FORM. INCLUDE THE
ADDRESS AND RETAIL STORE IDENTIFIER (FOR EXAMPLE RETAIL A)
IN THE TITLE BLOCK. THE FORMS SHOULD INCLUDE A SIGNATURE.
*
23. REMOVE DETAIL WAT-6 AND ADD DETAIL MET-12.
*
24. THERE IS A DISCREPANCY BETWEEN THE FIRE LINE SIZE
SHOWN ON THE PLANS AND THE SIZE SHOWN ON THE DETAIL "FIRE
PROTECTION SYSTEM RISER". PLEASE MAKE NECESSARY CHANGE TO
THE DETAIL OR SHOW REDUCER ON PLANS AND/OR DETAIL.
25. REVISE THE APPROXIMATE QUANTITIES TABLE ON THE COVER
SHEET AS NECESSARY BASED ON THESE COMMENTS.
*
26. BE ADVISED THAT FOR ALL ONSITE PUBLIC WATERLINES
AND/OR SEWER LINES THAT ARE CONTAINED WITHIN EASEMENTS, TH
EASEMENTS MUST BE DEDICATED PRIOR TO ACCEPTANCE OF
UTILITIES INTO SYSTEM.
*
27. PRIOR TO RELEASE OF THE PROJECT TO THE CONSTRUCTION
SECTION, A COPY OF THE ENVIRONMENTAL ENGINEERING APPROVAL
LETTER AND/OR ALL OTHER APPLICABLE LOCAL STATE AND FEDERAL
AGENCIES' APPROVAL LETTERS MUST BE RECEIVED BY THE
UTILITIES DEPARTMENT.
*
28. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY-APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THESE
DOCUMENTS TO THE ATTENTION OF ANNE URENDA
(URENDAA@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
*
29. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO ONE APPROVED SET FROM PLANNING (4 TOTAL SETS).
ONE ADDITIONAL ROLLED SET WILL BE REQUESTED AFTER THE
PROJECT IS RELEASED TO CONSTRUCTION TO BE USED FOR AS-
BUILTS.
*
ATTACHMENTS:
METER SIZING FORM (EMAIL ATTACHMENT)
SITE UTILIZATION FORM (EMAIL ATTACHMENT)
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, P.E./(804)748-1343
NAME OF PLAN : HANCOCK VILLAGE PHASE II RETAIL
ADDRESS : 14601 HANCOCK VILLAGE STREET
SUBMISSION DATE : 6/16/17
PLAN DATED : 6/13/17
REVIEW DATE : 6/28/17
CASE NO. : 17PR0240
COMMENTS : 2ND REVIEW-NOT APPROVED
TABLE REVIEW : YES
1. ON THE UTILITY MATERIALS QUANTITIES TABLE, LIST
"PUBLIC" AND "PRIVATE" QUANTITIES FOR BOTH THE WATER AND
SEWER ITEMS. ALSO CHECK THE QUANTITIES FOR THE
8" 45-DEGREE BENDS, 2" PVC PIPE, AND 2" COPPER PIPE.
I CAME UP WITH DIFFERENT QUANTITIES.
2. REPLACE DETAIL WAT-11 WITH DETAIL MET-12.
3. AS A CONDITION OF A TABLE REVIEW, REVISED PLAN SHEETS
AND A COMMENT RESPONSE LETTER MUST BE SUBMITTED IN PDF
FORMAT TO ANNE URENDA BY THE FRIDAY PRIOR TO THE TABLE
REVIEW DATE.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, P.E./(804)748-1343
NAME OF PLAN : HANCOCK VILLAGE PHASE II RETAIL
ADDRESS : 14601 HANCOCK VILLAGE STREET
SUBMISSION DATE : 8/9/17
PLAN DATED : 8/9/17
REVIEW DATE : 8/9/17
CASE NO. : 17PR0240
COMMENTS : APPROVED
TABLE REVIEW :
*
THIS PLAN HAS NOW BEEN APPROVED BY UTILITIES AT TABLE REVI
.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: HANCOCK VILLAGE PHASE II RETAIL
SITE PLAN NUMBER: 17PR0240
LATEST PLAN DATE: 04/21/17
DEPT. REC'D. DATE: 05/03/17
SUBMITTAL NUMBER: ONE
REVIEW DATE: 05/17/17
RECOMMENDATION: APPROVED
.
ADVISORY COMMENT (NO RESPONSE REQUIRED): UPON APPROVAL OF
THIS PLAN, THE REMAINING DENSITY IS 93,188 SF SHOP CENTER
AND 55,000 SF OF OFFICE/WAREHOUSE OR EQUIVALENT DENSITY AS
DETERMINED BY CDOT.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: HANCOCK VILLAGE PHASE II RETAIL
SITE PLAN NUMBER: 17PR0240
LATEST PLAN DATE: 06/13/17
DEPT. REC'D. DATE: 06/16/17
SUBMITTAL NUMBER: TWO
REVIEW DATE: 06/26/17
RECOMMENDATION: APPROVED
.
ADVISORY COMMENT (NO RESPONSE REQUIRED): UPON APPROVAL OF
THIS PLAN, THE REMAINING DENSITY IS 93,218 SF SHOP CENTER
AND 55,000 SF OF OFFICE/WAREHOUSE OR EQUIVALENT DENSITY AS
DETERMINED BY CDOT.
==========================================================
==========================================================
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------HANCOCK VILLAGE, PHASE II
SITE PLAN NUMBER----------17PR0240
ADDRESS-------------------14601 HANCOCK VILLAGE STREET
LATEST PLAN DATE----------04/21/17
DEPT. REC'D. DATE---------04/21/17
SUBMITTAL NUMBER----------1
REVIEW DATE---------------05/17/17
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------YES
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----NOT REQUIRED
ARCHITECTURAL ELEVATIONS--PRELIMINARY SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT REQUIRED
IRRIGATION/HOSEBIB PLAN---NOT REQUIRED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS.
RESUBMIT 10 FULL SETS AND ONE COPY OF THE SITE PLAN
SHEET TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW.
PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH
COMMENT DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW
COMMENT. INDICATE WHICH SHEETS SHOW THE REQUIRED
CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE ANY
CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
2. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER IN THE
LOWER RIGHT CORNER OF EACH SHEET: 17PR0240
3. LIST THE APPLICABLE CASES IN THE SITE DATA ON THE COVER
95SN0278, 07PR0220
4. LIST THE CORRECT DESIGN DISTRICT IN THE SITE DATA ON TH
COVER: ROUTE 360 WEST
5. CONDITION 25 OF ZONING CASE 95SN0278 STATES THE
FOLLOWING: THE LAST KNOWN PRESIDENT OF THE ASHBROOK
COMMUNITY ASSOCIATION SHALL BE MAILED NOTICES BY THE
OWNER/DEVELOPER OF ANY SITE PLAN SUBMISSION TO CHESTERFIEL
COUNTY. PRIOR TO SITE PLAN APPROVAL THE OWNER/DEVELOPER
SHALL PROVIDE THE PLANNING DEPARTMENT WITH EVIDENCE OF SUC
MAILING.
ADMINISTRATIVE SITE PLAN AND PLANNING COMMISSION SITE PLAN
NOTICES SHALL BE POSTMARKED A MINIMUM OF 10 DAYS PRIOR TO
APPROVAL OR DISAPPROVAL OF THE PLAN. 19.1-42.E.2.C
6. PROVIDE A SIDEWALK OF AT LEAST 5 FEET IN WIDTH ALONG TH
WEST SIDE OF THE NEW BUILDING EXTENDING FROM THE SIDEWALK
IN THE FRONT OF THE BUILDING TO THE REAR OF THE BUILDING
FOR PEDESTRIAN CONNECTION TO FUTURE DEVELOPMENT ON THE
PARCEL BEHIND THE SHOPPING CENTER.
7. PROVIDE TWO FULL SIZED COPIES OF COLOR RENDERED BUILDIN
ELEVATIONS THAT REFLECT ELEMENTS INCLUDED IN DISCUSSIONS
WITH STAFF. SOME OF THESE ELEMENTS INCLUDE: RAISED CORNICE
ON TUESDAY MORNING SIMILAR TO FIVE BELOW, EIGHT FOOD DEEP
CONTINUOUS CANOPY ON THE FRONT OF THE BURLINGTON.
8. PROVIDE A BUILDING ELEVATION THAT SHOWS A FULL CORNICE
ALONG THE REAR OF THE NEW PORTION OF THE BUILDING SIMILAR
TO THE TREATMENT ON THE EXISTING PORTION OF THE BUILDING.
9. PER SEC. 19.1-317.C, SHOW THAT JUNCTION AND ACCESS BOXE
ARE EITHER SCREENED OR PAINTED TO MATCH THE BUILDING EXCEP
AS ALLOWED IN I-2 AND I-3 DISTRICTS.
10. PER SEC. 19.1-317.D, MECHANICAL EQUIPMENT, WHETHER
ROOF-TOP OR GROUND LEVEL, SHALL BE SHIELDED AND SCREENED
FROM PUBLIC VIEW AND DESIGNED TO BE PERCEIVED AS AN
INTEGRAL PART OF THE BUILDING EXCEPT AS ALLOWED IN I-2 AND
I-3 DISTRICTS. SHOW ALL UNITS IN RELIEF BEHIND PARAPETS
AND/OR WALLS USED FOR SCREENING TO SHOW THAT UNITS ARE
FULLY SCREENED. 19.1-317.D
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------HANCOCK VILLAGE, PHASE II
SITE PLAN NUMBER----------17PR0240
ADDRESS-------------------14601 HANCOCK VILLAGE STREET
LATEST PLAN DATE----------06/13/17
DEPT. REC'D. DATE---------06/13/17
SUBMITTAL NUMBER----------2
REVIEW DATE---------------07/06/17
RECOMMENDATION------------SUBSTANTIAL APPROVAL
TABLE REVIEW--------------YES
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----NOT REQUIRED
ARCHITECTURAL ELEVATIONS--SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT REQUIRED
IRRIGATION/HOSEBIB PLAN---NOT REQUIRED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS.
RESUBMIT 10 FULL SETS AND ONE COPY OF THE SITE PLAN
SHEET TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW.
PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH
COMMENT DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW
COMMENTS.
2. ARCHITECTURAL ELEVATIONS PROVIDED BY TIMMONS VIA EMAIL
ON 06-30-17 WERE REVIEWED IN LIEU OF THE PRINTED COLOR
ELEVATIONS SUBMITTED WITH THE SITE PLAN. THE SUBMITTED
PRINTED ELEVATIONS WERE AN EARLIER DESIGN ITERATION.
PLEASE ADDRESS THE FOLLOWING PERTAINING TO THE
ARCHITECTURAL ELEVATIONS:
A. INCREASE THE DEPTH OF THE CANOPIES ON THE FRONT OF THE
BURLINGTON STORE TO A MINIMUM OF 8 FEET TO PROVIDE
SIGNIFICANT COVER FOR PEDESTRIANS.
B. PROVIDE (2) FULL-SIZED PRINTED COLOR ELEVATIONS FOR
REVIEW.
3. PER SEC. 19.1-317.C, SHOW THAT JUNCTION AND ACCESS BOXE
ARE EITHER SCREENED OR PAINTED TO MATCH THE BUILDING EXCEP
AS ALLOWED IN I-2 AND I-3 DISTRICTS.
4. PER SEC. 19.1-317.D, MECHANICAL EQUIPMENT, WHETHER
ROOF-TOP OR GROUND LEVEL, SHALL BE SHIELDED AND SCREENED
FROM PUBLIC VIEW AND DESIGNED TO BE PERCEIVED AS AN
INTEGRAL PART OF THE BUILDING EXCEPT AS ALLOWED IN I-2 AND
I-3 DISTRICTS. SHOW ALL UNITS IN RELIEF BEHIND PARAPETS
AND/OR WALLS USED FOR SCREENING TO SHOW THAT UNITS ARE
FULLY SCREENED. 19.1-317.D
**********************************************************
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : HANCOCK VILLAGE PH II RETAIL
CASE NUMBER : 17PR0240
LATEST PLAN DATE : 4/21/17
RECEIVED DATE : 5/5/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 5/11/17
ADDRESS : PENDING
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. MORE THAN ONE DIRECTION OF TRAVERSE IS SHOWN.
PLEASE REVISE THE SURVEY TO SHOW ONLY ONE PATH OF
TRAVERSE.
2. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY.
3. THE PARCEL BOUNDARY SURVEY DOESN'T CLOSE. THE
DISTANCE FOR N42-02-39E IS TOO LONG. IT SHOULD BE 77.13
FEET.
4. STREET ADDRESS LOCATIONS ARE NOT SHOWN. THEY CAN BE
LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF A
MONUMENT SIGN. LOCATION AND MATERIAL USED MUST BE NOTED
ON THE SITE PLAN. IF YOU ARE USING A MONUMENT SIGN, A
DETAIL OF THE MONUMENT SIGN MUST BE ON THE SITE PLAN.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : HANCOCK VILLAGE PH II RETAIL
CASE NUMBER : 17PR0240
LATEST PLAN DATE : 6/13/17
RECEIVED DATE : 6/19/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 7/6/17
ADDRESS : SHOWN BELOW
STATUS : APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. STREET ADDRESS LOCATIONS ARE NOT SHOWN. LOCATION AND
MATERIAL USED MUST BE NOTED ON THE SITE PLAN.
2. THE ADDRESSES WILL BE AS FOLLOWS:
RETAIL A-1: 14601 HANCOCK VILLAGE ST.
RETAIL A-2: 14605 HANCOCK VILLAGE ST.
RETAIL A-3: 14609 HANCOCK VILLAGE ST.
RETAIL B: 14613 HANCOCK VILLAGE ST.
RETAIL C: 14617 HANCOCK VILLAGE ST.
==========================================================
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: HANCOCK VILLAGE PH. 2 RETAIL
SITE PLAN NUMBER: 17PR0240
ADDRESS: 14601 HANCOCK VILLAGE STREET
LATEST PLAN DATE: 4/21/17
DEPT. REC'D. DATE: 5/8/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 5/15/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. PROVIDE COMPUTER GENERATED WATER FLOW TEST DATA,
PROVIDED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT, VERIFYING THE REQUIRED WATER FLOW FOR FIRE
PROTECTION IS AVAILABLE AT THE SITE. THE WATERFLOW TEST
RESULTS AND GRAPH SHALL BE SHOWN ON THE SUBMITTED PLAN.
THE MINIMUM REQUIRED FIRE FLOW FOR ALL BUILDINGS, WITH
THE EXCEPTION OF ONE AND TWO-FAMILY DWELLINGS, IS 1500
GPM (SPRINKLER PROTECTED OR NON-SPRINKLER PROTECTED) IN
ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (2012) -
SECTION B105.2 AND TABLE B105.1.
2. SHOW THE DETAIL OF THE P.I.V.'S TO INSURE THE NEW P.I.V
WILL NOT BE DOWNSTREAM FROM THE EXISTING P.I.V. OR EACH
OTHER.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: HANCOCK VILLAGE PH. 2 RETAIL
SITE PLAN NUMBER: 17PR0240
ADDRESS: 14601 HANCOCK VILLAGE STREET
LATEST PLAN DATE: 6/13/17
DEPT. REC'D. DATE: 6/20/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 6/23/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.