Thanksgiving Holiday Closings... MORE

Hover here for Site Tools
Site Plan Review Comments
All Site Plan Review Comments for Case # 17PR0212
Modify comments view for Case # 17PR0212

Go to Case Selection Form or Go to Project List

 
CASE NO: 17PR0212 STATUS: APPROVED - ADMIN
PROJECT NAME: COXENDALE RECYCLING - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: INDUSTRIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 02/22/17 03/15/17 ******** ********
ENVIR.ENGR.-: 01 06/07/17 06/28/17 ******** ********
FIRE DEPT.--: 01 06/07/17 06/28/17 COMPLETE 06/15/17 AWB 717-6167
MAPPING/GIS-: 01 06/07/17 06/28/17 COMPLETE 06/27/17 AMJ 768-7549
PLANNING----: 01 06/07/17 06/28/17 ******** ********
TRANSPORT.--: 01 06/07/17 06/28/17 COMPLETE 06/12/17 SJA 751-4461
UTIL.PLAN.--: 01 06/07/17 06/28/17 ******** ********
UTILITIES---: 01 06/07/17 06/28/17 AMENDED* 06/28/17 CRP 796-7126
UTIL.R.O.W.-: 01 06/07/17 06/28/17 ******** ********
VDOT--------: 01 06/07/17 06/28/17 ******** ********
.
PROPOSED WITH THIS PLAN, AS PER THE ENGINEER.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ADDRESS : 1800 AND 1830 COXENDALE ROAD
SUBMISSION DATE : 2/22/17
PLAN DATED : 2/20/17
REVIEW DATE : 3/7/17
SITE PLAN NO. : 17PR0212
COMMENTS : 1ST REVIEW -APPROVED
TABLE REVIEW :
PLAT PROCESS :
1. NO UTILITIES IMPACT. THERE ARE NO UTILITY CONNECTIONS
PROPOSED WITH THIS PLAN, AS PER THE ENGINEER.
.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RANDY PHELPS/796-7126
NAME OF PLAN : COXENDALE RECYCLING FACILITY
ADDRESS : 1800 AND 1830 COXENDALE ROAD
SUBMISSION DATE : 6/7/17
PLAN DATED : 6/5/17
REVIEW DATE : 6/27/17
SITE PLAN NO. : 17PR0212
COMMENTS : 2ND REVIEW - RE-APPROVED
TABLE REVIEW :
PLAT PROCESS :
1. NO UTILITIES IMPACT. THERE ARE NO UTILITY CONNECTIONS P
POSED WITH THIS PLAN, AS PER THE ENGINEER.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: COXENDALE RECYCLING FACILITY
SITE PLAN NUMBER: 17PR0212
LATEST PLAN DATE: 02/20/17
DEPT. REC'D. DATE: 02/27/17
SUBMITTAL NUMBER: ONE
REVIEW DATE: 03/10/17
RECOMMENDATION: NOT APPROVED
.
1. PRIOR TO SITE PLAN APPROVAL, DEDICATE 35' FROM
CENTERLINE ALONG THE PROPERTY'S FRONTAGE TO COXENDALE RD.
.
2. FOR THE FUTURE THOROUGHFARE PLAN ALIGNMENT:
A. REDUCE WIDTH OF FUTURE ALIGNMENT TO 90';
B. BOLD OR THICKEN MAJOR ARTERIAL LIMITS; AND,
C. LABEL AS "APPROXIMATE LOCATION OF 90' MAJOR ARTERIAL PE
COUNTY'S THORUGHFARE PLAN."
.
3. PROVIDE VDOT STANDARD COMMERCIAL ACCESS TO COXENDALE RD
.
4. NOTE COUNTY CLASSIFICATION (COLLECTOR) FOR COXENDALE RD
.
5. ADVISORY COMMENT: ANY FUTURE DEVELOPMMENT WILL REQUIRE
THE CONSTRUCTION OF LEFT AND RIGHT TURN LANES INTO THE
DEVELOPMENT. RIGHT TURN LANES WERE DESIGNED AND APPROVED
WITH PREVIOUS SITE PLAN CASE 93PR0176.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: COXENDALE RECYCLING FACILITY
SITE PLAN NUMBER: 17PR0212
LATEST PLAN DATE: 06/05/17
DEPT. REC'D. DATE: 06/08/17
SUBMITTAL NUMBER: TWO
REVIEW DATE: 06/12/17
RECOMMENDATION: NOT APPROVED
PLAT PROCESSING: R/W DEDICATION - COXENDALE RD
SITE PLAN APPROVAL IS PENDING RIGHT-OF-WAY DEDICATION ALON
COXENDALE ROAD 35' FROM CENTERLINE ALONG PROPERTY'S
FRONTAGE. COORDINATE WITH JOE DUTY IN COUNTY R/W SECTION.
.
ADVISORY COMMENT: ANY FUTURE DEVELOPMMENT WILL REQUIRE
THE CONSTRUCTION OF LEFT AND RIGHT TURN LANES INTO THE
DEVELOPMENT. RIGHT TURN LANES WERE DESIGNED AND APPROVED
WITH PREVIOUS SITE PLAN CASE 93PR0176.
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : COXENDALE RECYCLING FACILITY
CASE NUMBER : 17PR0212
LATEST PLAN DATE : 2/20/17
RECEIVED DATE : 2/24/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 3/14/17
ADDRESS : 1800 AND 1830 COXENDALE RD
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY.
2. STREET ADDRESS LOCATION IS NOT SHOWN. LOCATION AND
MATERIAL USED MUST BE NOTED ON THE SITE PLAN. THE
MATERIAL USED MUST BE MORE DURABLE THAN WOOD.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : COXENDALE RECYCLING FACILITY
CASE NUMBER : 17PR0212
LATEST PLAN DATE : 6/5/17
RECEIVED DATE : 6/9/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 6/27/17
ADDRESS : 1800 AND 1830 COXENDALE RD
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. STREET ADDRESS SIGN LOCATION IS NOT SHOWN. LOCATION
AND MATERIAL USED MUST BE NOTED ON THE SITE PLAN FOR
PUBLIC SAFETY AND THE ROUTING OF FIRST RESPONDERS. THE
MATERIAL USED MUST BE MORE DURABLE THAN WOOD.
==========================================================
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: COXENDALE RECYCLING FACILITY
SITE PLAN NUMBER: 17PR0212
ADDRESS: 1800 COXENDALE ROAD
LATEST PLAN DATE: 2/20/17
DEPT. REC'D. DATE: 2/27/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 3/7/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. VIRGINIA STATEWIDE FIRE PREVENTION CODE (2012) STATES T
FOLLOWING:
2808.3 SIZE OF PILES: PILES SHALL NOT EXCEED 25 FEET IN
HEIGHT, 150 FEET IN WIDTH AND 250 FEET IN LENGTH.
EXCEPTION: THE FIRE CODE OFFICIAL IS AUTHORIZED TO
ALLOW THE PILE SIZE TO BE INCREASED WHEN ADDITIONAL
FIRE PROTECTION IS PROVIDED IN ACCORDANCE WITH
CHAPTER 9. THE INCREASE SHALL BE BASED UPON THE
CAPABILITIES OF THE SYSTEM INSTALLED.
2808.4 PILE SEPARATION: PILES SHALL BE SEPARATED FROM
ADJACENT PILES BY APPROVED APPARATUS ACCESS ROADS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: COXENDALE RECYCLING FACILITY
SITE PLAN NUMBER: 17PR0212
ADDRESS: 1800 COXENDALE ROAD
LATEST PLAN DATE: 6/5/17
DEPT. REC'D. DATE: 6/12/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 6/15/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.

Modify comments view for case # 17PR0212



Go to Case Selection Form or Go to Project List