Site Plan Review Comments
All Site Plan Review Comments for Case # 17PR0210
Modify comments view for Case # 17PR0210

Go to Case Selection Form or Go to Project List

 
CASE NO: 17PR0210 STATUS: APPROVED - ADMIN
PROJECT NAME: BRANCH POINT STORAGE - LAST INTERNET UPDATE: 11/20/17
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 03 06/26/17 07/11/17 ******** ********
ENVIR.ENGR.-: 03 06/26/17 07/11/17 ******** ********
FIRE DEPT.--: 03 06/26/17 07/11/17 COMPLETE 06/28/17 AWB 717-6167
MAPPING/GIS-: 03 06/26/17 07/11/17 COMPLETE 07/10/17 AMJ 768-7549
PLANNING----: 03 06/26/17 07/11/17 COMPLETE 07/10/17 JJD 717-6191
TRANSPORT.--: 03 06/26/17 07/11/17 COMPLETE 06/30/17 SJA 751-4461
UTIL.PLAN.--: 03 06/26/17 07/11/17 ******** ********
UTILITIES---: 03 06/26/17 07/11/17 AMENDED* 07/10/17 CRP 796-7126
UTIL.R.O.W.-: 03 06/26/17 07/11/17 ******** ********
VDOT--------: 03 06/26/17 07/11/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RANDY PHELPS / 804-796-7126
NAME OF PLAN : BRANCH POINT STORAGE
ADDRESS : 6500 BRANCH POINT DRIVE
SUBMISSION DATE : 2/15/17
PLAN DATED : 2/10/17
REVIEW DATE : 03/03/17
SITE PLAN NO. : 17PR0210
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
.
.
1. PLACE COUNTY PROJECT NUMBER 15-0113 ON THE LOWER RIGHT
CORNER OF EACH SHEET.
2. PLEASE PUT UTILITIES CONTACT RANDY PHELPS, 796-
7126, PHELPSC@CHESTERFIELD.GOV ON THE COVER SHEET.
3. ON SHEET C-1, CORRECT THE PROJECT NAME SHOWN IN THREE
) LOCATIONS (TITLE, UNDER "SITE SUMMARY AND NOTES", AND IN
OWER RIGHT HAND CORNER) TO READ AS "6500 BRANCH POINT DRIV
SELF STORAGE FACILITY".
4. ON THE MATERIAL LIST, INDICATE ITEMS THAT ARE "PUBLIC"
ERSUS "PRIVATE".
.
.
5. ON SHEETS C-7 AND C-10, CHANGE THE SIZE OF ALL NEW WAT
LINE TO 8" INSTEAD OF 6". REVISE SIZE OF ALL ASSOCIATED T
S, VALVES AND PLUGS AS APPROPRIATE.
6. ON SHEET C-7, INDICATE THE DISTANCE BETWEEN THE WATER
NES AND FOC AS 4 FEET.
7. ADD TWO VALVES AT THE TEE BETWEEN WATER LINES 'A' AND
'.
8. PROVIDE A DETAIL OR NOTE INDICATING THAT THE EXISTING
MING OFF OF THE 24" WATER LINE ALONG HULL STREET ROA
IS TO BE USED FOR CUT-OFF DURING THE NEW WATER LINE TIE-IN
9. PROVIDE AND LABEL A 1" SERVICE LINE TO THE WATER
METER.
10. IT APPEARS THAT THE DOUBLE CHECK ASSEMBLY WILL BE LOCA
D INTERNALLY TO THE PROPOSED STRUCTURE. IF THIS IS ACCURAT
ADD A NOTE TO SHEET C-7 INDICATING SAME, AND DELETE DETAI
FIR-3 (BOTH INSTANCES) FROM SHEET C-16.
11. ON SHEETS C-7 AND C-19, SHOW A BUMP-OUT ON THE EASEME
FOR WATER LINE 'B' TO COVER THE WATER METER BOX.
12. LABEL THE FDC AND FIRE LINES ON THE PLAN AS "PRIVATE"
13. IS THERE A DESIRE FOR AN IRRIGATION METER ON THIS
PROJECT? IF SO, SHOW THE LOCATION IN THE PROXIMITY OF THE
OMESTIC METER, WITHIN THE EASEMENT, AND SUBMIT A METER SIZ
G FORM. ALSO, INDICATE THE REQUIRED BACKFLOW PREVENTION DE
CE.
14. SINCE THE SEWER LINE CLEANOUT WILL BE WITHIN A PAVED A
A, PROVIDE DETAIL SEW-11 ON SHEET C-16.
.
15. ON SHEET C-7, SHOW THE EXISTING SEWER SERVICE LATERAL,
OMING OUT OF THE MANHOLE AT THE SOUTHERN PROPERTY LINE, WH
H SERVES THE SONABANK ON GPIN 7276733007. LABEL AS "CO. PR
. U04-24D, 6" PVC SAN. SEWER". THIS SERVICE LATERAL IS TO
PROTECTED DURING ADJACENT DEMOLITION AND CONSTRUCTION WOR
.
.
EASEMENT AND APPROPRIATE TEMPORARY CONSTRUCTION EASEMENTS,
TUBBING OUT TO THE EASTERN PROPERTY LINE, BEGINNING AT A
POINT APPROXIMATELY 85 FEET FROM THE TERMINATING END OF WA
R LINE 'A'. THE UTILITIES DEPARTMENT DESIRES THAT THIS EAS
ENT BE PROVIDED TO ALLOW FOR THE FUTURE LOOPING OF WATER L
E 'A' WITH AN EXISTING 8" WATER LINE ON GPIN 7276747015 IF
EEMED NECESSARY FOR SYSTEM OPERATIONAL PURPOSES.
.
OWN ON SHEET C-10.
18. CLEARLY LABEL WATER LINES 'A' AND 'B' AS "PUBLIC" ON S
ETS C-7 AND C-10.
19. ON SHEET C-7, CLEARLY DELINEATE BETWEEN "PUBLIC" AND "
IVATE" AT THE EASEMENT.
.
20. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF RANDY PHELPS
(PHELPSC@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
21. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS).
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RANDY PHELPS / 804-796-7126
NAME OF PLAN : BRANCH POINT STORAGE
ADDRESS : 6500 BRANCH POINT DRIVE
SUBMISSION DATE : 4/06/17
PLAN DATED : 4/04/17
REVIEW DATE : 4/27/17
SITE PLAN NO. : 17PR0210
COMMENTS : 2ND REVIEW - APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
THE PLANS FOR "BRANCH POINT STORAGE", WITH THE LATEST REVI
ON DATE OF 04/04/17 ARE APPROVED WITH NO EXCEPTIONS. ONCE
L DEPARTMENTS HAVE APPROVED THE PLANS, PLEASE SUBMIT 3 COP
S DIRECTLY TO THE UTILITIES DEPARTMENT FOR USE DURING
CONSTRUCTION
THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF RANDY PHELPS
(PHELPSC@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RANDY PHELPS / 804-796-7126
NAME OF PLAN : BRANCH POINT STORAGE
ADDRESS : 6500 BRANCH POINT DRIVE
SUBMISSION DATE : 5/30/17
PLAN DATED : 5/25/17
REVIEW DATE : 6/19/17
SITE PLAN NO. : 17PR0210
COMMENTS : 3RD REVIEW - RE-APPROVED
TABLE REVIEW :
PLAT PROCESS :
THE PLANS FOR "BRANCH POINT STORAGE", WITH THE LATEST REVI
ON DATE OF 05/25/17 ARE RE-APPROVED WITH NO EXCEPTIONS. ON
ALL DEPARTMENTS HAVE APPROVED THE PLANS, PLEASE SUBMIT 3
PIES DIRECTLY TO THE UTILITIES DEPARTMENT FOR USE DURING C
STRUCTION.
THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF RANDY PHELPS
(PHELPSC@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RANDY PHELPS / 804-796-7126
NAME OF PLAN : BRANCH POINT STORAGE
ADDRESS : 6500 BRANCH POINT DRIVE
SUBMISSION DATE : 6/27/17
PLAN DATED : 6/26/17
REVIEW DATE : 7/7/17
SITE PLAN NO. : 17PR0210
COMMENTS : 4TH REVIEW - RE-APPROVED
TABLE REVIEW :
PLAT PROCESS :
THE PLANS FOR "BRANCH POINT STORAGE", WITH THE LATEST REVI
ON DATE OF 06/26/17 ARE RE-APPROVED WITH NO EXCEPTIONS. ON
ALL DEPARTMENTS HAVE APPROVED THE PLANS,
PLEASE SUBMIT 3 COPIES DIRECTLY TO THE UTILITIES DEPARTME
FOR USE DURING CONSTRUCTION.
THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOS
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE T
ITEMS TO THE ATTENTION OF RANDY PHELPS
(PHELPSC@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASE
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PL
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION O
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
LATEST PLAN DATE: 02/10/17
DEPT. REC'D. DATE: 02/16/17
SUBMITTAL NUMBER: ONE
REVIEW DATE: 02/16/17
RECOMMENDATION: APPROVAL PENDING ZONING CASE APPRVOAL
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
LATEST PLAN DATE: 04/04/17
DEPT. REC'D. DATE: 04/11/17
SUBMITTAL NUMBER: TWO
REVIEW DATE: 04/19/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
LATEST PLAN DATE: 05/25/17
DEPT. REC'D. DATE: 06/02/17
SUBMITTAL NUMBER: THREE
REVIEW DATE: 06/12/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
LATEST PLAN DATE: 06/26/17
DEPT. REC'D. DATE: 06/28/17
SUBMITTAL NUMBER: FOUR
REVIEW DATE: 06/30/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
EMAIL------------------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN----------- BRANCH POINT STORAGE
SITE PLAN NUMBER-------17PR0210
LATEST PLAN DATE------- 02/10/2017
DEPT. REC'D. DATE------ 02/15/2017
ACEEPTED FOR REVIEW-02/15/2017
SUBMITTAL NUMBER---ONE -CURSORY REVIEW ONLY
REVIEW DATE------------ 03/07/2017
RECOMMENDATION---------NOT APPROVED
TABLE REVIEW----------- NO
LANDSCAPE PLAN STATUS- REQUESTED
ARCHITECTURAL ELEVATIONS-REQUESTED
LIGHTING PLAN/CUTSHEETS--- REQUESTED
IRRIGATION/HOSEBIB PLAN--- REQUESTED
REVIEW COMMENTS:
.
01.RESUBMIT 12 FULL SETS & 1 COPY OF THE SITE PLAN SHEET
TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. THE
FIRST SUBMITTAL SHALL INCLUDE A PLAN DATE (MONTH, DAY &
YEAR), AND EACH REVISED SET OF PLANS SHALL SHOW A
REVISION DATE PUT A REVISION DATE ON THE RESUBMITTED
PLANS.
.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS USING THE
SPACE BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE
ADDRESSED EACH REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED. PROVIDE A
TRANSMITTAL LETTER TO DESCRIBE ANY CHANGES TO THE PLANS
NOT CAUSED BY STAFF REVIEW COMMENTS. (CL X.X
REPRESENTS CHECKLIST ITEM #)
.
03. NOTE THAT THE PROJECT SITE IS CURRENTLY IN THE ZONING
PROCESS. UNDERSTANDING THIS, THIS SUBMITTAL REVIEW IS
A CURSORY REVIEW AS ZONING CONDITIONS MAY ALTER THE
DESIGN OF THE PLAN. ZONING APPROVAL WILL BE REQUIRED
PRIOR TO PLAN APPROVAL.
.
04. THE NAME OF THE PROJECT IS REQUIRED TO BE THE SAME
ON BOTH THE APPLICATION AND PLANS. PLEASE REVISE.
REVIEWER RECOMMENDS CHANGING THE NAME ON PLANS TO
BRANCH POINT STORAGE TO POSSIBLY AVOID RE-ADVERTISING
PUBLIC NOTICE.
.
05. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER
17PR0210 IN THE LOWER RIGHT CORNER OF EACH SHEET.
.
06. PRIOR TO SITE PLAN APPROVAL, SUBMIT A LETTER FROM
THE BRANDERMILL COMMUNITY ASSOCIATION APPROVING
ARCHITECTURAL ELEVATIONS.
07. SHOW ANY EXISTING AND/OR PROPOSED GAS, POWER, AND
TELEPHONE LINES AND EASEMENTS (IF KNOWN). SEC. 19.1-27. F.
.
08. IF PENDING CASE 17SN0602 IS APPROVED, PLEASE UPDATE
SITE SUMMARY & GENERAL NOTES TO REFLECT THIS CASE AND
ZONING CLASSIFICATION.
.
09. UNDER SITE SUMMARY & NOTES CHANGE USE DESCRIPTION
FROM "STORAGE" TO "INDOOR SELF STORAGE FACILITY".
.
10. PER MY DISCUSSION WITH RYAN RAMSEY THE CASE
MANAGER FOR THE PENDING ZONING CASE THE APPLICANT
TENTATIVELY IS REQUESTING A 20' REAR BUFFER AND 30'
SIDE YARD BUFFER ON THE WEST LINE. THE PROPOSED LIMITS
OF LAND DISTURBANCE SHOW ENCROACHMENT INTO THE
PROPOSED BUFFERS. IN ADDITION, IF THE ZONING CASE IS
APPROVED LABEL THE BUFFER AND REQUIRED LANDSCAPE.
.
11. LABEL ON THE PLAN ANY SETBACK EXCEPTIONS ALLOWED
BY A VARIANCE, ZONING CASE, OR BY SETBACK AVERAGING ALONG
A MAJOR ARTERIAL STREET PER SEC. 19.1-27F
.
12. PER SEC. 19-572, SITES SHALL BE DESIGNED AND
BUILDINGS ORIENTED SO THAT LOADING AREAS ARE SCREENED
FROM VIEW OF ADJACENT PROPERTIES WHERE SUCH A USE IS
NOT PERMITTED.
.
13. SHOW PROPOSED NUMBER OF STORIES AND HEIGHTS
FOR BUILDING. HEIGHT IS LIMITED TO 2 STORIES/30'FEET.
.
14. SHOW LOCATION OF ALL SOLID WASTE STORAGE AREAS (
DUMPSTERS/TRASH CANS). ANY SUCH STORAGE AREA
WITHIN 100 FEET OF AN R, R-TH, R-MF, SHALL HAVE
THE ENCLOSURE CONSTRUCTED OF MATERIALS SIMILAR TO
THE BUILDING IT SERVES.
.
15. ANY DUMPSTERS WITHIN 1000 FEET OF A RESIDENTIAL
DISTRICT SHALL NOT BE SERVICED BETWEEN THE
HOURS OF 9:00 P.M. AND 6:00 A.M. SUCH AREAS
SHALL BE PROMINENTLY POSTED WITH A SIGN NOT TO
EXCEED SIX SQUARE FEET DESIGNATING THE HOUR'S IN
WHICH THE SOLID WASTE STORAGE AREA MAY BE SERVICED.
PROVIDE SIGN DETAIL ON PLANS
.
16. IS ANY OUTDOOR PUBLIC ADDRESS OR INTERCOM SYSTEM
PROPOSED? OUTDOOR PUBLIC ADDRESS SYSTEMS ARE
ALLOWED ONLY BY CONDITIONAL USE.
.
OR GREATER, A 4-FOOT-HIGH FENCE SHALL BE INSTALLED ON
THE UPPER SIDE OF THE WALL. IT'S VISIBLE TO THE PUBLIC,
THE FENCE SHE'LL HAVE A DECORATIVE DESIGN.L. ANY
FENCE AROUND THE VISIBLE FROM PUBLIC VIEW OR ADJACENT
PROPERTIES ARE REQUIRED TO BE AN ORNAMENTAL FENCE
REQUIRING THE APPROVAL OF BOTH PLANNING AND
ENVIRONMENTAL ENGINEERING.
18. IDENTIFY THE BUILDING, DRIVEWAY, AND PARKING SETBACKS
FOR FRONT, SIDE, AND REAR YARDS, AND LABEL THEM ON THE PLA
ALONG WITH ANY REQUIRED LANDSCAPE STANDARD TO BE APPLIED
THROUGH THE DEVELOPMENT OF THE LANDSCAPE PLAN.
.
19. ARE THERE ANY RETAINING WALLS PROPOSED. IF YES,
SHOW LOCATION ON SITE LAYOUT AND GRADING PLANS AND
PROVIDE A RETAINING WALL DETAIL. PER SEC. 19.1-320 (
RETAINING WALLS USE SAME SETBACKS AS REQUIRED FOR
DRIVES AND PARKING PER SEC. 19.1-320.1(C), AND MAY
INCREASE WHEN LANDSCAPING IS REQUIRED TO INSURE 10
FEET OF PLANTING AREA FREE FROM EASEMENTS, UTILITIES,
OR OTHER ENCUMBRANCES THAT MIGHT PREVENT THE
INSTALLATION OF REQUIRED LANDSCAPING.)
IN ADDITION, DECORATIVE FENCING IS REQUIRED. 19.1-320:
FOR RETAINING WALL'S HAVING A HEIGHT OF 4 FEET
OR GREATER, A 4-FOOT-HIGH FENCE SHALL BE INSTALLED ON
THE UPPER SIDE OF THE WALL. IT'S VISIBLE TO THE PUBLIC,
THE FENCE SHE'LL HAVE A DECORATIVE DESIGN.
.
20. PER SEC. 19.1-247A1, GRADING WITHIN
BUFFERS THAT IMPACTS EXISTING VEGETATION IS NOT ALLOWED
EXCEPT AS SPECIFIED IN THIS SECTION.
.
21. PER SEC. 19.1-262.B, USES IN BUFFERS ARE LIMITED TO
LANDSCAPING AND SCREENING, SIGNS, SECURITY FENCING,
UTILITIES THAT RUN PERPENDICULAR THROUGH THE BUFFER,
PEDESTRIAN WALKWAYS, AND SIMILAR USES AS APPROVED
THROUGH SITE OR SCHEMATIC PLAN REVIEW
.
22. PER SEC. 19-264(D) (18), PROVIDE 2 COPIES OF
RENDERINGS/ELEVATIONS OF THE BUILDINGS WITH ALL
BUILDING MATERIALS AND COLORS IDENTIFIED, LOCATIONS
OF JUNCTION AND ACCESS BOXES SHOWN, AND HOW
ALL MECHANICAL EQUIPMENT IS SCREENED WHETHER
IT IS MOUNTED ON THE ROOF OR ON THE GROUND.
ELEVATIONS MUST COMPLY WITH PENDING ZONING CASE,
ROUTE 360 CORRIDOR WEST - SEC. 19-586.2) &
ACHIEVES COMPATIBILITY WITH THE OVERALL PROJECT.
ENSURE ELEVATIONS REFLECT LOADING AREAS.
.
23. SHOW LOCATION OF ROOF ACCESS IF ANY ACCESS
TO ROOF MUST BE INSIDE BUILDING. EXTERIOR
LADDERS NOT ALLOWED.
.
24. PER SEC. 19.1-317C, SHOW THAT JUNCTION AND
ACCESS BOXES ARE EITHER SCREENED OR PAINTED TO
MATCH THE BUILDING.
.
25. PER SEC. 19.1-317D, MECHANICAL EQUIPMENT,
WHETHER ROOF-TOP OR GROUND LEVEL, SHALL BE
SHIELDED AND SCREENED FROM PUBLIC VIEW AND
DESIGNED TO BE PERCEIVED AS AN INTEGRAL PART
OF THE BUILDING SHOW ALL UNITS IN RELIEF BEHIND
PARAPETS AND/OR WALLS USED FOR SCREENING TO
SHOW THAT UNITS ARE FULLY SCREENED.
OF THE BUILDING SHOW ALL UNITS IN RELIEF BEHIND
PARAPETS AND/OR WALLS USED FOR SCREENING TO
SHOW THAT UNITS ARE FULLY SCREENED.
26.. LABEL DEED BOOK & PAGE NUMBER OF RECORDED
EASEMENT AGREEMENT ALLOWING ACCESS TO PROPERTY.
.
LIGHTING:
.
01.PER SEC.19.1-205, SHOW ON THE LANDSCAPE PLAN OR
ADDITIONALLY, ON A SEPARATE LIGHTING PLAN THE LOCATION
OF ALL EXTERIOR SITE LIGHTING MOUNTED ON POLES, THE
BUILDING, OR ON THE GROUND AND HAVE THEM KEYED TO
CUT SHEETS FOR EACH LIGHT FIXTURE SHOWN ON THE PLAN.
.
02. PROVIDE CATALOGUE CUT SHEETS FOR EACH EXTERIOR LIGHT
FIXTURE PROPOSED. PER PROFFERED CONDITION 10, PARKING
LOT LIGHTING SHALL NOT EXCEED A HEIGHT OF TWENTY (20)
FEET.
.
03. PER SEC..1-205, SUBMIT A FOOT-CANDLE OUTPUT DIAGRAM
WHENEVER A SITE IS ADJACENT TO A RESIDENTIAL DISTRICT AND
DOCUMENT THAT THE MAXIMUM ILLUMINATION DOES NOT
EXCEED 0.5 FOOT-CANDLES AT THE PROPERTY LINE WITH THE
RESIDENTIAL DISTRICT.
.
04. PER SEC.19.1-205ALL LIGHT FIXTURES SHALL BE OF A
DIRECTIONAL TYPE THAT SHIELDS THE LIGHT SOURCE FROM
DIRECT VIEW FROM ANY ADJOINING, A, R, R-TH, MH,
TND, OR R-MF DISTRICT OR PUBLIC RIGHT-OF -WAY.
.
LANDSCAPING & IRRIGATION
.
01. PER SEC. 19.1-253B(A), PARKING LOTS MUST BE DESIGNED
TO INCLUDE 30 S. F. OF INTERIOR PARKING LOT LANDSCAPING
FOR EACH PARKING SPACE. PROVIDE A CALCULATION
FOR THE TOTAL NUMBER OF PARKING SPACES TIMES
30 S.F. TO DETERMINE TOTAL LANDSCAPE AREA WITHIN
PARKING LOT. (EXAMPLE: 100 PARKING SPACES X 30
S.F. = 3000 S.F. LANDSCAPE AREA IN PARKING LOT)
.
02. PER SEC. 19.1-253.C, THE TOTAL NUMBER OF TREES IN
A PARKING LOT SHALL BE 1 PER 200 S.F. OF LANDSCAPE
AREA IN THE PARKING LOT. SHOW THE CALCULATION
FOR TOTAL NUMBER OF TREES. (EXAMPLE: 3000 S.F.
LANDSCAPE AREA DIVIDED BY 200 S.F. PER TREE = 15 TREES)
03. PER SEC. 19.1-253.C, AT LEAST 50% OF THE TREES
SHALL BE LARGE MATURING TREES THAT ARE IN ISLANDS
WITH A MINIMUM WIDTH OF 15 FEET AND 250 S.F.
IN SIZE. SMALL MATURING TREES SHALL BE IN ISLANDS
WITH A MINIMUM WIDTH OF 9 FEET AND BE 150 S.F. IN SIZE.
.
04. PER SEC. 19.1-27 E, THE LANDSCAPE PLAN
SHALL IDENTIFY THE STATE REGISTERED
LANDSCAPE ARCHITECT, NURSERYMAN, OR LANDSCAPE
DESIGNER PREPARING THE PLAN.
.
05. THE LANDSCAPE PLAN SHALL SHOW THE FOLLOWING:
PER SEC. 19-517(A) AND (B), AT LEAST A CONCEPTUAL
LANDSCAPING PLAN SHALL BE APPROVED PRIOR TO RELEASE OF
FINAL SITE PLAN APPROVAL. WHETHER THE PLAN SUBMITTED IS
A CONCEPTUAL OR DETAILED LANDSCAPE PLAN, THE PLAN SHALL
SHOW THE FOLLOWING:
A. ALL EASEMENTS AND RIGHTS OF WAY, FIRE HYDRANT LOCATIONS
AND SITE LIGHTING LOCATIONS.
B. WIDTH OF PERIMETER YARDS AND BUFFERS AND THE
ORDINANCE STANDARD FOR THE PLANTING OF EACH YARD
AND/OR BUFFER - SHOW SEPARATE TABULAR CALCULATION OF
REQUIRED AND PROPOSED PLANTINGS FOR EACH YARD AND/OR
BUFFER.
C. SHOW CALCULATIONS FOR PLANTING OF INTERIOR PARKING LOT
AREAS (SEE SEC. D - PARKING - REVIEW COMMENTS 15-20).
D. SHOW BMP AREAS AND ADDRESS PER SEC. 19-518(I) IF
REQUIRED TO TREAT AS A VISUAL AMENITY.
E. IF A CONCEPTUAL PLAN IS SUBMITTED, SHOW ARRANGEMENT OF
ALL PLANTS AND IDENTIFY EACH AS LARGE OR SMALL DECIDUOUS
TREES, EVERGREEN TREES, MEDIUM SHRUBS, AND SMALL SHRUBS/
GROUNDCOVERS. THESE MAY BE KEYED TO A CONCEPTUAL PLANT
LIST SHOWING THESE PLANT TYPES AND THE QUANTITIES OF EACH.
F. IF A DETAILED LANDSCAPE PLAN IS SUBMITTED, SPECIFY THE
PLANTS AND THEIR REQUIRED SIZES FOR EACH OF THE PLANT TYPE
REQUIRED PER SEC. 19-518(B).
G. SHOW ALL AREAS OF EXISTING TREES TO REMAIN AND CLEARLY
LABEL AS SUCH. SEE SEC. 19-518(D) REGARDING REQUIREMENTS
FOR TREE PRESERVATION.
H. HEALTHY EXISTING TREES MAY BE CREDITED TOWARD PLANTING
REQUIREMENTS SO LONG AS EXISTING VEGETATION IS
REASONABLY DISTRIBUTED THROUGHOUT THE LENGTH OF THE SETBAC
AREA.
I. REMOVAL OF EXISTING TREES WITHIN THE SETBACK OR BUFFER
WITHOUT WRITTEN APPROVAL FROM THE PLANNING DEPARTMENT
SHALL RESULT IN TWO TREES BEING PLANTING FOR EACH TREE
REMOVED. THE 50' AND 100" FOOT BUFFERS MAY NOT BE
DISTURBED PER CONDITION OF ZONING.
J. ANY EXISTING TREES IN SETBACKS THAT ARE APPROVED FOR
REMOVAL SHALL BE SHOWN AS SUCH ON THE EROSION CONTROL,
GRADING AND LANDSCAPE PLANS.
K. PER SEC. 19-518(C), THE LANDSCAPE DESIGN SHALL BE
REQUIRED TO PROVIDE A PROFESSIONALLY ACCEPTABLE
COMPOSITION AND MIX OF VEGETATION.
L. PER SEC. 19-518(C), DECORATIVE WALLS AND FENCES,
HAVING A MINIMUM HEIGHT OF 36 INCHES, MAY REDUCE
THE AMOUNT OF REQUIRED PLANT MATERIALS AS DETERMINED
AT TIME OF SITE PLAN OR SCHEMATIC APPROVAL.
M. PROVIDE STANDARD COUNTY LANDSCAPE NOTES ON DETAILED
LANDSCAPE PLAN
N. EACH REVIEW OF DETAILED LANDSCAPE PLANS AFTER
APPROVAL OF THE SITE PLAN INCURS A RESUBMITTAL FEE AND
IS TRACKED AS A SITE PLAN REVIEW UNTIL APPROVED.
APPROVAL MUST BE OBTAINED PRIOR TO TEMPORARY OCCUPANCY
OF THE BUILDING.
.
06. PER SEC. 19.1-249 ALL LANDSCAPED AREAS SHALL BE
PROVIDED WITH A READILY AVAILABLE WATER SUPPLY. THE
COUNTY ACCEPTS EITHER YARD HYDRANTS AND/OR HOSE BIBS
WITHIN 100 FEET OF ALL NEW PLANTINGS OR AN IRRIGATION
SYSTEM FOR ALL AREAS OF NEW PLANTINGS.
THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE
WITH WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE
SPECIES. INSURE WATER INFORMATION IS SUPPLIED ON UTILITY
DEPARTMENT METER SIZING FORMS. ONE OTHER ALTERNATIVE
IN LIEU OF IRRIGATION REQUIREMENTS ARE TO PLANT DROUGHT
TOLERANT NATIVE PLANT SPECIES CHOSEN FROM THE CHESTERFIELD
COUNTY PLANT MATERIAL LIST. PLEASE CONTACT JEFF DOPP FOR
A COPY OF THIS LIST.
.
07. THE LANDSCAPE PLAN MUST INCLUDE STANDARD
LANDSCAPE NOTES. CONTACT JEFF DOPP IF YOU
.
08. SUBMIT TWO SEPARATE COPIES OF THE IRRIGATION AND/OR
HOSE BIB PLAN MUST BE SUBMITTED DIRECTLY TO THE
PLANNING DEPARTMENT. THIS PLAN MUST BE APPROVED
PRIOR TO RELEASE OF THE BUILDING PERMIT. SHOW ALL
CONNECTIONS TO THE MAIN WATER LINE. HOSE BIBS
SHOULD BE SHOWN ON THE LANDSCAPE PLAN. AND
IRRIGATION HEADS AND COVERAGE AREAS MUST BE
SHOWN ON A SEPARATE IRRIGATION PLAN. (CL D.13)
SEC. 19-518(E).
.
09. PRIOR TO RECEIVING A TEMPORARY OCCUPANCY PERMIT,
THE APPLICANT SHALL PROVIDE A LETTER OF GUARANTEE
(COUNTY FORMAT) TO REPLACE ALL UNHEALTHY OR DEAD
PLANTS OR POLLARDED TREES IDENTIFIED BY THE ONE
YEAR INSPECTION BY THE PLANNING DEPARTMENT.
ADDITIONALLY, A FORM OF SURETY (BOND OR LETTER OF CREDIT)
AN AMOUNT EQUAL TO THE COST OF COMPLETING THE REQUIRED
LANDSCAPING SHALL BE PROVIDED TO THE PLANNING
DEPARTMENT.
##########################################################
##########################################################
##########################################################
##########################################################
REVIEWER / PHONE #-----JEFF DOPP/717-6191
EMAIL------------------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN----------- BRANCH POINT STORAGE
SITE PLAN NUMBER-------17PR0210
LATEST PLAN DATE------- 04/04/2017
DEPT. REC'D. DATE------ 04/05/2017
ACEEPTED FOR REVIEW-04/06/2017
SUBMITTAL NUMBER---TWO -CURSORY REVIEW ONLY
REVIEW DATE------------ 05/01/2017
RECOMMENDATION---------NOT APPROVED
TABLE REVIEW----------- NO
LANDSCAPE PLAN STATUS- REQUESTED
ARCHITECTURAL ELEVATIONS-NOT APPROVED
LIGHTING PLAN/CUTSHEETS---REQUESTED
IRRIGATION/HOSEBIB PLAN--- REQUESTED
REVIEW COMMENTS:
.
01.RESUBMIT 12 FULL SETS & 1 COPY OF THE SITE PLAN SHEET
TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. THE
FIRST SUBMITTAL SHALL INCLUDE A PLAN DATE (MONTH, DAY &
YEAR), AND EACH REVISED SET OF PLANS SHALL SHOW A
REVISION DATE PUT A REVISION DATE ON THE RESUBMITTED
PLANS.
.
03. NOTE THAT THE PROJECT SITE IS CURRENTLY IN THE ZONING
PROCESS. THIS SUBMITTAL REVIEW IS A CURSORY REVIEW
AS ZONING CONDITIONS MAY ALTER THE DESIGN OF THE PLAN.
ZONING APPROVAL WILL BE REQUIRED PRIOR TO PLAN APPROVAL.
DETERMINATION OF THIS CASE IS SCHEDULED FOR BOS
CONSIDERATION ON 5/24/2017.
.
04. PRIOR TO SITE PLAN APPROVAL, SUBMIT A LETTER FROM
THE BRANDERMILL COMMUNITY ASSOCIATION APPROVING
THE ARCHITECTURAL ELEVATIONS.
.
05. SHEET C-1: PLEASE REVISE SITE SUMMARY & GENERAL
NOTES TO INCLUDE CASE 17SN0602 AND CHANGE ZONING
CLASSIFICATION FROM O-2 TO "GENERAL COMMERCIAL C-5
WITH CUPD".
.
06. SHEET C-1: LABEL FOLLOWING NOTE: "HOURS OF
OPERATION SHALL BE NO EARLIER THAN 6:00 A.M. AND NO
LATER THAN 10:00 P.M. DAILY".
.
07. THE PROPOSED LIMITS OF LAND DISTURBANCE SHOW
ENCROACHMENT INTO THE REQUIRED BUFFERS. REVISE
LIMITS OF LAND DISTURBANCE SO DISTURBANCE DOES
.
.
08. LABEL AND DIMENSION ALL REQUIRED BUFFERS AND
REQUIRED LANDSCAPING (1.5 X PERIMETER C) ON THE
SITE LAYOUT, EROSION AND SEDIMENT CONTROL AND
GRADING SHEETS. REFERENCE CASE 17SN0602 FOR
REQUIRED BUFFERS AND LANDSCAPING.
.
09. ON ALL SITE LAYOUT, GRADING AND EROSION SEDIMENT
CONTROL SHEETS, WITHIN EACH BUFFER, LABEL "BUFFER TO
BE LEFT UNDISTURBED NO GRADING OR CLEARING OF
EXISTING VEGETATION ALLOWED".
.
10. ON EROSION AND SEDIMENT CONTROL AND GRADING
PLANS, SHOW TREE PROTECTION FENCING ALONG ALL
BUFFERS AND KEY THE TREE PROTECTION FENCING SYMBOL
TO THE LEGEND ON EACH SHEET.
.
11. DESIGN CONSULTANT HAS RESPONDED THAT NO SOLID
WASTE STORAGE IS PROVIDED. WHAT METHOD AND LOCATION
WILL SOLID WASTE BE STORED? IF INDOORS, ADD NOTE ON
PLANS THAT READS "SOLID WASTE STORAGE WILL BE STORED
INSIDE. TRASH CANS ARE STORED INSIDE BUILDING.
NO SOLID WASTE SERVICE WILL OCCUR BETWEEN 9:00PM
AND 6:00 A.M.".
12. RETAINING WALL'S HAVING A HEIGHT OF 4 FEET
OR GREATER, A 4-FOOT-HIGH FENCE SHALL BE INSTALLED ON
THE UPPER SIDE OF THE WALL. PLEASE ADD THIS NOTE ON
SHEET C-6 SHOWING THE RETAINING WALL DETAIL.
.
13. SHEET C-13: ADD NOTE TO THE SECURITY FENCE DETAIL
THAT STATES "ALTERNATIVE FENCE REQUIRES PLANNING
DEPARTMENT APPROVAL."
14. LABEL DEED BOOK & PAGE NUMBER OF RECORDED
EASEMENT AGREEMENT ALLOWING ACCESS TO PROPERTY.
.
LIGHTING:
01.PER SEC.19.1-205, SHOW ON THE LANDSCAPE PLAN OR
ADDITIONALLY, ON A SEPARATE LIGHTING PLAN THE LOCATION
OF ALL EXTERIOR SITE LIGHTING MOUNTED ON POLES, THE
BUILDING, OR ON THE GROUND AND HAVE THEM KEYED TO
CUT SHEETS FOR EACH LIGHT FIXTURE SHOWN ON THE PLAN.
.
02. PROVIDE CATALOGUE CUT SHEETS FOR EACH EXTERIOR
LIGHT FIXTURE PROPOSED. PER PROFFERED CONDITION 06,
LIGHT POLES SHALL NOT EXCEED FIFTEEN (15) FEET IN HEIGHT
.
03. PER SEC..1-205, SUBMIT A FOOT-CANDLE OUTPUT DIAGRAM
WHENEVER A SITE IS ADJACENT TO A RESIDENTIAL DISTRICT AND
DOCUMENT THAT THE MAXIMUM ILLUMINATION DOES NOT
EXCEED 0.5 FOOT-CANDLES AT THE PROPERTY LINE WITH THE
RESIDENTIAL DISTRICT.
.
04. PER SEC.19.1-205ALL LIGHT FIXTURES SHALL BE OF A
DIRECTIONAL TYPE THAT SHIELDS THE LIGHT SOURCE FROM
DIRECT VIEW FROM ANY ADJOINING, A, R, R-TH, MH,
TND, OR R-MF DISTRICT OR PUBLIC RIGHT-OF -WAY.
.
LANDSCAPING & IRRIGATION
,
01.PREPARE THE LANDSCAPE PLAN TO SHOW PERIMETER/
BUFFER LANDSCAPE PLANTINGS ARE BEING ACHIEVED.
HEALTHY EXISTING TREES OR SHRUBS MAYBE CREDITED
TOWARD LANDSCAPING REQUIREMENTS IF REASONABLY
DISTRIBUTED THROUGHOUT THE LENGTH OF THE BUFFER
AND OR SETBACK AREA.
.
02. PREPARE THE LANDSCAPE PLAN TO SHOW PERIMETER/BUFFER
LANDSCAPE PLANTINGS ARE BEING ACHIEVED. HEALTHY
EXISTING TREES OR SHRUBS MAYBE CREDITED TOWARD
LANDSCAPING REQUIREMENTS IF REASONABLY DISTRIBUTED
THROUGHOUT THE LENGTH OF THE AREA.
SEC. 19.1-262: BUFFER PROVIDED SHALL BE AN
UNBROKEN LANDSCAPE STRIP.
.
03.REGARDING THE LANDSCAPE PLAN SHOWING REQUIRED
PLANTINGS WITHIN THE 20' AND 30' BUFFERS, YOU MAY
EITHER HAVE A STATE REGISTERED LANDSCAPE ARCHITECT
PREPARES AND SUBMIT A DETAILED LANDSCAPE PLAN
MEETING ALL ORDINANCE REQUIREMENTS
OR LABEL THE FOLLOWING NOTE ON THE SITE PLAN AND
LANDSCAPE PLAN:
"AT TIME OF COMPLETION OF CLEARING AND GRADING, ALL
BUFFERS WILL BE FLAGGED AND DEVELOPER WILL CONTACT
THE PLANNING DEPARTMENT FOR A BUFFER INSPECTION.
IF THE QUANTITIES OF HEALTHY PLANTINGS ARE INSUFFICIENT
AND THE PLANTINGS ARE NOT REASONABLY DISTRIBUTED
THROUGHOUT EACH BUFFER, A LANDSCAPE PLAN WILL BE
PREPARED AND SUBMITTED IN ACCORDANCE WITH
SECTION 19.1-27 E, REQUIRING THE LANDSCAPE PLAN
TO BE PREPARED BY A STATE REGISTERED LANDSCAPE
ARCHITECT OR NURSERYMAN. CERTIFICATE OF OCCUPANCY
WILL NOT BE ISSUED UNTIL LANDSCAPE PLAN IS
APPROVED AND PLANTINGS ARE INSTALLED.
.
04.SHOW ON LANDSCAPE PLAN INTERIOR PARKING LOT
CALCULATIONS, PLANTINGS AND PLANT SCHEDULE.
PER SEC. 19.1-253B(A), PARKING LOTS MUST BE DESIGNED
TO INCLUDE 30 S. F. OF INTERIOR PARKING LOT LANDSCAPING
FOR EACH PARKING SPACE. PROVIDE A CALCULATION
FOR THE TOTAL NUMBER OF PARKING SPACES TIMES
30 S.F. TO DETERMINE TOTAL LANDSCAPE AREA WITHIN
PARKING LOT. (EXAMPLE: 100 PARKING SPACES X 30
S.F. = 3000 S.F. LANDSCAPE AREA IN PARKING LOT)
.
05. PER SEC. 19.1-253.C, THE TOTAL NUMBER OF TREES IN
A PARKING LOT SHALL BE 1 PER 200 S.F. OF LANDSCAPE
AREA IN THE PARKING LOT. SHOW THE CALCULATION
FOR TOTAL NUMBER OF TREES. (EXAMPLE: 3000 S.F.
LANDSCAPE AREA DIVIDED BY 200 S.F. PER TREE = 15 TREES)
.
06. PER SEC. 19.1-253.C, AT LEAST 50% OF THE TREES
SHALL BE LARGE MATURING TREES THAT ARE IN ISLANDS
WITH A MINIMUM WIDTH OF 15 FEET AND 250 S.F.
IN SIZE. SMALL MATURING TREES SHALL BE IN ISLANDS
WITH A MINIMUM WIDTH OF 9 FEET AND BE 150 S.F. IN SIZE.
.
07. PER SEC. 19.1-27 E, THE LANDSCAPE PLAN
SHALL IDENTIFY THE STATE REGISTERED
LANDSCAPE ARCHITECT, NURSERYMAN, OR LANDSCAPE
DESIGNER PREPARING THE PLAN.
08. THE LANDSCAPE PLAN SHALL SHOW THE FOLLOWING:
PER SEC. 19-517(A) AND (B), AT LEAST A CONCEPTUAL
LANDSCAPING PLAN SHALL BE APPROVED PRIOR TO RELEASE OF
FINAL SITE PLAN APPROVAL. WHETHER THE PLAN SUBMITTED IS
A CONCEPTUAL OR DETAILED LANDSCAPE PLAN, THE PLAN SHALL
SHOW THE FOLLOWING:
A. ALL EASEMENTS AND RIGHTS OF WAY, FIRE HYDRANT LOCATIONS
AND SITE LIGHTING LOCATIONS.
B. WIDTH OF PERIMETER YARDS AND BUFFERS AND THE
ORDINANCE STANDARD FOR THE PLANTING OF EACH YARD
AND/OR BUFFER - SHOW SEPARATE TABULAR CALCULATION OF
REQUIRED AND PROPOSED PLANTINGS FOR EACH YARD AND/OR
BUFFER.
C. SHOW CALCULATIONS FOR PLANTING OF INTERIOR PARKING LOT
AREAS (SEE SEC. D - PARKING - REVIEW COMMENTS 15-20).
D. SHOW BMP AREAS AND ADDRESS PER SEC. 19-518(I) IF
REQUIRED TO TREAT AS A VISUAL AMENITY.
E. IF A CONCEPTUAL PLAN IS SUBMITTED, SHOW ARRANGEMENT OF
ALL PLANTS AND IDENTIFY EACH AS LARGE OR SMALL DECIDUOUS
TREES, EVERGREEN TREES, MEDIUM SHRUBS, AND SMALL SHRUBS/
GROUNDCOVERS. THESE MAY BE KEYED TO A CONCEPTUAL PLANT
LIST SHOWING THESE PLANT TYPES AND THE QUANTITIES OF EACH.
F. IF A DETAILED LANDSCAPE PLAN IS SUBMITTED, SPECIFY THE
PLANTS AND THEIR REQUIRED SIZES FOR EACH OF THE PLANT TYPE
LANDSCAPE PLAN C. 19-518(B).
G. SHOW ALL AREAS OF EXISTING TREES TO REMAIN AND CLEARLY
LABEL AS SUCH. SEE SEC. 19-518(D) REGARDING REQUIREMENTS
FOR TREE PRESERVATION.
H. HEALTHY EXISTING TREES MAY BE CREDITED TOWARD PLANTING
REQUIREMENTS SO LONG AS EXISTING VEGETATION IS
REASONABLY DISTRIBUTED THROUGHOUT THE LENGTH OF THE SETBAC
AREA.
I. REMOVAL OF EXISTING TREES WITHIN THE SETBACK OR BUFFER
WITHOUT WRITTEN APPROVAL FROM THE PLANNING DEPARTMENT
SHALL RESULT IN TWO TREES BEING PLANTING FOR EACH TREE
REMOVED. THE 50' AND 100" FOOT BUFFERS MAY NOT BE
DISTURBED PER CONDITION OF ZONING.
J. ANY EXISTING TREES IN SETBACKS THAT ARE APPROVED FOR
REMOVAL SHALL BE SHOWN AS SUCH ON THE EROSION CONTROL,
GRADING AND LANDSCAPE PLANS.
K. PER SEC. 19-518(C), THE LANDSCAPE DESIGN SHALL BE
REQUIRED TO PROVIDE A PROFESSIONALLY ACCEPTABLE
COMPOSITION AND MIX OF VEGETATION.
L. PER SEC. 19-518(C), DECORATIVE WALLS AND FENCES,
HAVING A MINIMUM HEIGHT OF 36 INCHES, MAY REDUCE
THE AMOUNT OF REQUIRED PLANT MATERIALS AS DETERMINED
AT TIME OF SITE PLAN OR SCHEMATIC APPROVAL.
M. PROVIDE STANDARD COUNTY LANDSCAPE NOTES ON DETAILED
LANDSCAPE PLAN
N. EACH REVIEW OF DETAILED LANDSCAPE PLANS AFTER
APPROVAL OF THE SITE PLAN INCURS A RESUBMITTAL FEE AND
IS TRACKED AS A SITE PLAN REVIEW UNTIL APPROVED.
APPROVAL MUST BE OBTAINED PRIOR TO TEMPORARY OCCUPANCY
OF THE BUILDING.
.
09. PER SEC. 19.1-249 ALL LANDSCAPED AREAS SHALL BE
PROVIDED WITH A READILY AVAILABLE WATER SUPPLY. THE
COUNTY ACCEPTS EITHER YARD HYDRANTS AND/OR HOSE BIBS
WITHIN 100 FEET OF ALL NEW PLANTINGS OR AN IRRIGATION
SYSTEM FOR ALL AREAS OF NEW PLANTINGS.
THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE
WITH WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE
SPECIES. INSURE WATER INFORMATION IS SUPPLIED ON UTILITY
DEPARTMENT METER SIZING FORMS. ONE OTHER ALTERNATIVE
IN LIEU OF IRRIGATION REQUIREMENTS ARE TO PLANT DROUGHT
TOLERANT NATIVE PLANT SPECIES CHOSEN FROM THE CHESTERFIELD
COUNTY PLANT MATERIAL LIST. PLEASE CONTACT JEFF DOPP FOR
A COPY OF THIS LIST.
.
10. THE LANDSCAPE PLAN MUST INCLUDE STANDARD
LANDSCAPE NOTES. CONTACT JEFF DOPP IF YOU
NEED A COPY.
.
11. SUBMIT TWO SEPARATE COPIES OF THE IRRIGATION AND/OR
HOSE BIB PLAN MUST BE SUBMITTED DIRECTLY TO THE
PLANNING DEPARTMENT. THIS PLAN MUST BE APPROVED
PRIOR TO RELEASE OF THE BUILDING PERMIT. SHOW ALL
CONNECTIONS TO THE MAIN WATER LINE. HOSE BIBS
SHOULD BE SHOWN ON THE LANDSCAPE PLAN. AND
IRRIGATION HEADS AND COVERAGE AREAS MUST BE
SHOWN ON A SEPARATE IRRIGATION PLAN. (CL D.13)
SEC. 19-518(E).
.
12. PRIOR TO RECEIVING A TEMPORARY OCCUPANCY PERMIT,
THE APPLICANT SHALL PROVIDE A LETTER OF GUARANTEE
(COUNTY FORMAT) TO REPLACE ALL UNHEALTHY OR DEAD
PLANTS OR POLLARDED TREES IDENTIFIED BY THE ONE
YEAR INSPECTION BY THE PLANNING DEPARTMENT.
ADDITIONALLY, A FORM OF SURETY (BOND OR LETTER OF CREDIT)
AN AMOUNT EQUAL TO THE COST OF COMPLETING THE REQUIRED
LANDSCAPING SHALL BE PROVIDED TO THE PLANNING
DEPARTMENT.
.
ARCHITECTURAL ELEVATIONS
.
01.THE ELEVATIONS SUBMITTED ARE FOR A DIFFERENT
PROJECT LOCATED ON DABNEY ROAD THAT IS IN A
DIFFERENT LOCALITY. PLEASE SUBMIT CORRECT ELEVATIONS.
.
02.ZONING CASE 17SNM0602 REQUIRES THE ELEVATIONS
TO BE SUBSTANTIALLY SIMILAR TO THE ELEVATIONS SHOWN ON
EXHIBIT B. THE ELEVATIONS SUBMITTED ARE NOT SUBSTANTIALLY
SIMILAR. PLEASE REVISE IN ACCORDANCE TO CONDITION OF
ZONING.
.
03. PER SEC. 19-264(D) (18), PROVIDE 2 COPIES OF
COLORED RENDERINGS/ELEVATIONS OF THE BUILDINGS WITH ALL
BUILDING MATERIALS AND COLORS IDENTIFIED, LOCATIONS
OF JUNCTION AND ACCESS BOXES SHOWN, AND HOW
ALL MECHANICAL EQUIPMENT IS SCREENED WHETHER
IT IS MOUNTED ON THE ROOF OR ON THE GROUND.
ELEVATIONS MUST COMPLY WITH PENDING ZONING CASE,
ROUTE 360 CORRIDOR WEST - SEC. 19-586.2) &
ACHIEVES COMPATIBILITY WITH THE OVERALL PROJECT.
ENSURE ELEVATIONS REFLECT LOADING AREAS.
.
04. PER SEC. 19.1-317C, ADD NOTE ON
ELEVATION SHEETS THAT JUNCTION AND ACCESS
BOXES WILL BE SCREENED OR PAINTED TO
MATCH THE BUILDING.
.
05. PER SEC. 19.1-317D, MECHANICAL EQUIPMENT,
WHETHER ROOF-TOP OR GROUND LEVEL, SHALL BE
SHIELDED AND SCREENED FROM PUBLIC VIEW AND
DESIGNED TO BE PERCEIVED AS AN INTEGRAL PART
OF THE BUILDING SHOW ALL UNITS IN RELIEF BEHIND
PARAPETS AND/OR WALLS USED FOR SCREENING TO
SHOW THAT UNITS ARE FULLY SCREENED.
################################################
.
REVIEWER / PHONE #-----JEFF DOPP/717-6191
EMAIL------------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN----------- BRANCH POINT STORAGE
SITE PLAN NUMBER-------17PR0210
LATEST PLAN DATE------- 05/25/2017
DEPT. REC'D. DATE------ 05/36/2017
ACEEPTED FOR REVIEW-05/30/2017
SUBMITTAL NUMBER---THREE
REVIEW DATE------------ 06/12/2017
RECOMMENDATION---- NOT APPROVED
TABLE REVIEW----YES-SEE COMMENT
LANDSCAPE PLAN STATUS-NOT APPROVED
ARCHITECTURAL ELEVATIONS NOT APPROVED
LIGHTING PLAN/CUTSHEETS---NOT APPROVED
IRRIGATION/HOSEBIB PLAN---NOT REQUIRED
DROUGHT TOLERANT NATIVE PLANTS PROVIDED.
REVIEW COMMENTS:
.
01.RESUBMIT 12 FULL SETS & 1 COPY OF THE SITE PLAN SHEET
TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. THE
FIRST SUBMITTAL SHALL INCLUDE A PLAN DATE (MONTH, DAY &
YEAR), AND EACH REVISED SET OF PLANS SHALL SHOW A
REVISION DATE PUT A REVISION DATE ON THE RESUBMITTED
PLANS.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS USING THE
SPACE BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE
ADDRESSED EACH REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED. PROVIDE A
TRANSMITTAL LETTER TO DESCRIBE ANY CHANGES TO THE PLANS
NOT CAUSED BY STAFF REVIEW COMMENTS. (CL X.X
REPRESENTS CHECKLIST ITEM #)
.
03. SUBMIT A $350.00 RESUBMITTAL FEE.
.
04. PER PREVIOUS REVIEW COMMENT SUBMIT A LETTER
FROM THE BRANDERMILL COMMUNITY ASSOCIATION
APPROVING THE ARCHITECTURAL ELEVATIONS.
.
05. ADJACENT PROPERTY TO NORTH IDENTIFIED AS TAX ID#
727-673-1375 ZONING IS INCORRECTLY SHOWN AS C-3.
REVISE TO SHOW ZONED I-1.
.
06. THE APPROVED TEXTUAL STATEMENT REQUIRES
THE 30' BUFFER ALONG THE WESTERN LINE TO BE
PLANTED WITH A TREATMENT FOR A 50-FOOT-WIDE BUFFER
TREATMENT. THIS REQUIRES1.5 PERIMETER C LANDSCAPING.
PLEASE REVISE TO SHOW 1.5X PERIMETER C ON ALL SHEETS.
.
07. SHEET C-13: LABEL AND DIMENSION REQUIRED
BUFFERS ON SWM/BMP PLAN.
08. SHEET L-400: LIGHT POLES SHALL NOT EXCEED
FIFTEEN (15) FEET IN HEIGHT. PROPOSED LIGHT POLE
SES-25-50-7TA-DB DOES NOT SHOW HEIGHT AND
INDICATES A 25' TALL POLE. PLEASE PROVIDE A
MANUFACTURER SPEC SHEET KEYED TO SHOW A 15'
MAXIMUM POLE HEIGHT.
.
LANDSCAPING & IRRIGATION
.
09. L100: THE WIDTH OF THE PARKING LOT ISLAND
ADJACENT TO THE 8 PARKING SPACES DOES NOT MEET
THE MINIMUM WIDTH OF 15' FEET TO ACCOMMODATE
A LARGE DECIDUOUS TREE. REVISE TO REMOVE A PARKING
SPACE OR SHOW A SMALL DROUGHT TOLERANT DECIDUOUS
INTERIOR PARKING LOT TREE FROM THE CHESTERFIELD
COUNTY PLANT MATERIAL LIST. PER SEC. 19.1-253.C,
AT LEAST 50% OF THE TREES SHALL BE LARGE MATURING
TREES THAT ARE IN ISLANDS WITH A MINIMUM WIDTH
OF 15 FEET AND 250 S.F. IN SIZE. SMALL MATURING TREES
SHALL BE IN ISLANDS WITH A MINIMUM WIDTH OF 9 FEET
AND BE 150 S.F. IN SIZE.
.
10. L100: SHIFT THE AUTUMN GOLD GINGKO FURTHER
AWAY FROM DRIVE AISLE TO PREVENT ROOT DAMAGE TO
DRIVEWAY.
.
11. SHEET L100: LABEL METES AND BOUNDS FOR
ALL PROPERTY LINES AND LABEL THE PERIMETER LANDSCAPE
REQUIREMENTS WITHIN ALL BUFFERS AND SETBACKS.
IF PLAN QUALIFIES FOR A TABLE REVIEW. EMAIL A PDF
OF REVISED LANDSCAPE PLAN IF A MINIMUM OF 3 BUSINESS
DAYS PRIOR TO SCHEDULED TABLE REVIEW AND REVIEWER WILL
PROVIDE A CURSORY REVIEW.
.
12. PER SEC. 19-264(D) (18), PROVIDE 2 COPIES OF
COLORED RENDERINGS/ELEVATIONS FOR ALL SIDES OF THE
BUILDINGS. IDENTIFY MATERIALS AND COLORS. TWO
COLOR COPIES SUBMITTED WERE NOT COMPLETE
WITH PORTION OF BUILDING CUT-OFF AND COLOR
TREATMENTS WERE NOT IDENTIFIED.
.
13. PER SEC. 19.1-317C, ADD NOTE ON
ELEVATION SHEETS THAT JUNCTION AND ACCESS
BOXES WILL BE SCREENED OR PAINTED TO
MATCH THE BUILDING.
.
14. PER SEC. 19.1-317D, MECHANICAL EQUIPMENT,
WHETHER ROOF-TOP OR GROUND LEVEL, SHALL BE
SHIELDED AND SCREENED FROM PUBLIC VIEW AND
DESIGNED TO BE PERCEIVED AS AN INTEGRAL PART
OF THE BUILDING SHOW ALL UNITS IN RELIEF BEHIND
PARAPETS AND/OR WALLS USED FOR SCREENING TO
SHOW THAT UNITS ARE FULLY SCREENED. GHOST LINE
RTU'S IS ACCEPTABLE TO MEET THIS REQUIREMENT.
.
15. IF ALL DEPARTMENTS RECOMMEND A TABLE REVIEW
PLEASE SEND REVISED ELEVATIONS PRIOR TO TABLE REVIEW.
#################################################
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #-----JEFF DOPP/717-6191
EMAIL------------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN----------- BRANCH POINT STORAGE
SITE PLAN NUMBER-------17PR0210
LATEST PLAN DATE------- 06/26/2017
DEPT. REC'D. DATE------ 06/26/2017
SUBMITTAL NUMBER---FOUR
REVIEW DATE------------ 07/06/2017
RECOMMENDATION----
TABLE REVIEW----YES-
LANDSCAPE PLAN STATUS- APPROVED
ARCHITECTURAL ELEVATIONS -NOT APPROVED
LIGHTING PLAN/CUTSHEETS---APPROVED
IRRIGATION/HOSEBIB PLAN---NOT REQUIRED
DROUGHT TOLERANT NATIVE PLANTS PROVIDED.
REVIEW COMMENTS:
.
01.RESUBMIT 12 FULL SETS & 1 COPY OF THE SITE PLAN SHEET
TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. THE
FIRST SUBMITTAL SHALL INCLUDE A PLAN DATE (MONTH, DAY &
YEAR), AND EACH REVISED SET OF PLANS SHALL SHOW A
REVISION DATE PUT A REVISION DATE ON THE RESUBMITTED
PLANS.
.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS USING THE
SPACE BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE
ADDRESSED EACH REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED. PROVIDE A
TRANSMITTAL LETTER TO DESCRIBE ANY CHANGES TO THE PLANS
NOT CAUSED BY STAFF REVIEW COMMENTS. (CL X.X
REPRESENTS CHECKLIST ITEM #)
.
03. SUBMIT A $350.00 RESUBMITTAL FEE IF A RESUBMITTAL
OR TABLE REVIEW IS REQUIRED.
.
4. IDENTIFY AND LABEL ON THE EAST AND WEST ELEVATIONS
THE OBJECT PROTRUDING ABOVE THE PARAPET LOCATED
GENERALLY IN THE CENTER. IF THIS IS AN RTU, IT WILL
NOT BE ALLOWED TO EXCEED THE HEIGHT OF THE BUILDING
PARAPET.
.
5. REVIEWER HAS CONCERNS THE HEIGHT FROM TOP OF
ROOF STRUCTURE TO TOP OF MECHANICAL EQUIPMENT IS
ONLY 3' 8". THIS HEIGHT APPEARS TO BE INSUFFICIENT
TO FULLY SCREEN RTU'S. DEPENDING ON THE UNIT TONNAGE
AND MANUFACTUER REQUIRMENTS THE HEIGHT OF A 20-75 T
ON UNIT NOT INCLUDING THE ROOF CURB CAN RANGE FROM
5" 8' TO 6'-8" IN HEIGHT. IN ADDITION, MANUFACTUER'S
MAY HAVE ROOF CURB SPECIFICATIONS RANGING FROM
12" -24" INCHES.
PER SEC. 19.1-317D, MECHANICAL EQUIPMENT,
WHETHER ROOF-TOP OR GROUND LEVEL, SHALL BE
SHIELDED AND SCREENED FROM PUBLIC VIEW AND
DESIGNED TO BE PERCEIVED AS AN INTEGRAL PART
OF THE BUILDING SHOW ALL UNITS IN RELIEF BEHIND
PARAPETS AND/OR WALLS USED FOR SCREENING TO
SHOW THAT UNITS ARE FULLY SCREENED. GHOST LINE
RTU'S IS ACCEPTABLE TO MEET THIS REQUIREMENT.
.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : BRANCH POINT STORAGE
CASE NUMBER : 17PR0210
LATEST PLAN DATE : 2/10/17
RECEIVED DATE : 2/17/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 3/3/17
ADDRESS : 6500 BRANCH POINT DR
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. THE PROPERTY ADDRESS IS INCORRECT ON PAGE C-1 IN THE
TITLE, THE PROJECT NAME AND IN THE SITE SUMMARY & NOTES.
2. MORE THAN ONE DIRECTION OF TRAVERSE IS SHOWN.
PLEASE REVISE THE SURVEY TO SHOW ONLY ONE PATH OF
TRAVERSE.
3. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY.
4. STREET ADDRESS LOCATION IS NOT SHOWN. IT CAN BE
LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF A
MONUMENT SIGN. LOCATION AND MATERIAL USED MUST BE
NOTED ON THE SITE PLAN. IF YOU ARE USING A MONUMENT
SIGN, A DETAIL OF THE MONUMENT SIGN MUST BE ON THE
SITE PLAN.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : BRANCH POINT STORAGE
CASE NUMBER : 17PR0210
LATEST PLAN DATE : 2/10/17
RECEIVED DATE : 4/11/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 4/26/17
ADDRESS : 6500 BRANCH POINT DR
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. STREET ADDRESS LOCATION IS NOT SHOWN. IT CAN BE
LOCATED ON THE BUILDING, ON A SIGN OR AS A PART OF A
MONUMENT SIGN. LOCATION AND MATERIAL USED MUST BE
NOTED ON THE SITE PLAN. IF YOU ARE USING A MONUMENT
SIGN, A DETAIL OF THE MONUMENT SIGN MUST BE ON THE
SITE PLAN.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : BRANCH POINT STORAGE
CASE NUMBER : 17PR0210
LATEST PLAN DATE : 5/25/17
RECEIVED DATE : 6/1/17
SUBMITTAL NUMBER : 3
REVIEW DATE : 6/20/17
ADDRESS : 6500 BRANCH POINT DR
STATUS : APPROVED
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : BRANCH POINT STORAGE
CASE NUMBER : 17PR0210
LATEST PLAN DATE : 6/26/17
RECEIVED DATE : 6/30/17
SUBMITTAL NUMBER : 4
REVIEW DATE : 7/10/17
ADDRESS : 6500 BRANCH POINT DR
STATUS : APPROVED
==========================================================
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
ADDRESS: 6500 BRANCH POINT DRIVE
LATEST PLAN DATE: 2/10/17
DEPT. REC'D. DATE: 2/17/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 3/6/16
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. A NOTE ADDRESSING THE REQUIREMENTS BELOW SHALL BE
ADDED TO THE GENERAL NOTES ON THE SITE PLAN.
"DURING THE CONSTRUCTION OF ANY STRUCTURE OR BUILDING,
PERMANENT FIRE HYDRANTS SHALL BE INSTALLED, PRIOR TO THE
USE OF COMBUSTIBLE MATERIALS IN CONSTRUCTION BEING USED
ON ANY FLOOR ABOVE THE FIRST FLOOR OR GROUND FLOOR
LEVEL HYDRANTS SHALL BE FUNCTIONAL FOR FIRE FIGHTING
PURPOSES AND MAINTAINED ACCESSIBLE TO FIRE FIGHTING
APPARATUS AT ALL TIMES. AN APPROVED ALL-WEATHER ROAD
SURFACE SHALL BE PROVIDED FOR ACCESS TO THE FIRE HYDRANTS
DURING CONSTRUCTION." SEE CHESTERFIELD COUNTY CODE
SECTION 106.9
2. RELOCATE THE FDC TO SAME SIDE OF THE DRIVE AISLE AS THE
FIRE HYDRANT
3. PROVIDE THE CODE MODIFICATION REQUEST LETTER TO ADDRESS
NOT MEETING THE SECOND ACCESS FOR A BUILDING TALLER THAN
30 FEET.
4. REPLACE THE FIR-3 DETAIL WITH THE 2012 EDITION.
5. PROVIDE THE DETAILS FOR THE AUTOMATIC SPRINKLER SYSTEM
RUN-IN AND STUB UP, INCLUDING ALL APPLICABLE NOTES. SEE:
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
FOR A COPY OF THE DETAILS
6. PROVIDE THE REQUIRED THRUST BLOCK DESIGN AND RODDING
DETAIL CHART FOR FIRE PROTECTION UNDERGROUND. ALSO
PROVIDE THE MINIMUM CONCRETE AMOUNT DESIGN CHART. THRUST
BLOCKS FOR FIRE PROTECTION UNDERGROUND SHALL BE DESIGNED
AT A MINIMUM TEST PRESSURE OF 225 PSI. THE REQUIRED
CHARTS AND DETAILS CAN BE OBTAINED FROM THE INTERNET FOR
CHESTERFIELD COUNTY - CHESTERFIELD FIRE AND EMS -
DIVISION OF FIRE AND LIFE SAFETY -
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
ADDRESS: 6500 BRANCH POINT DRIVE
LATEST PLAN DATE: 4/4/17
DEPT. REC'D. DATE: 4/10/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 4/11/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. ATTACH THE CODE MODIFICATION REQUEST LETTER
AND THE CODE MODIFICATION APPROVAL LETTER TO THE
SITE PLAN.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
ADDRESS: 6500 BRANCH POINT DRIVE
LATEST PLAN DATE: 5/2517
DEPT. REC'D. DATE: 6/1/17
SUBMITTAL NUMBER: 3RD REVIEW
REVIEW DATE: 6/8/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: BRANCH POINT STORAGE
SITE PLAN NUMBER: 17PR0210
ADDRESS: 6500 BRANCH POINT DRIVE
LATEST PLAN DATE: 6/26/17
DEPT. REC'D. DATE: 6/26/17
SUBMITTAL NUMBER: 4TH REVIEW
REVIEW DATE: 6/29/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.

Modify comments view for case # 17PR0210



Go to Case Selection Form or Go to Project List