Site Plan Review Comments
All Site Plan Review Comments for Case # 17PR0198
Modify comments view for Case # 17PR0198

Go to Case Selection Form or Go to Project List

 
CASE NO: 17PR0198 STATUS: APPROVED - ADMIN
PROJECT NAME: CUSTOM METAL FABR SI - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: INDUSTRIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 01/05/17 01/27/17 ******** ********
ENVIR.ENGR.-: 01 03/14/17 04/04/17 ******** ********
FIRE DEPT.--: 01 03/14/17 04/04/17 COMPLETE 03/20/17 AWB 717-6167
MAPPING/GIS-: 01 03/14/17 04/04/17 COMPLETE 03/31/17 AMJ 768-7549
PLANNING----: 01 03/14/17 04/04/17 COMPLETE 04/11/17 CH 717-6042
TRANSPORT.--: 01 03/14/17 04/04/17 COMPLETE 03/30/17 SJA 751-4461
UTIL.PLAN.--: 01 03/14/17 04/04/17 ******** ********
UTILITIES---: 01 03/14/17 04/04/17 AMENDED* 03/22/17 A U
UTIL.R.O.W.-: 01 03/14/17 04/04/17 ******** ********
VDOT--------: 01 03/14/17 04/04/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA/748-1343
NAME OF PLAN : SITE IMPROVEMENTS FOR CUSTOM METAL FABR
ADDRESS : 7601 WHITEPINE ROAD
SUBMISSION DATE : 1/5/17
PLAN DATED : 12/27/16
REVIEW DATE : 1/10/17
SITE PLAN NO. : 17PR0198
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. UTILITIES PROJECT NUMBER 16-0315 SHALL BE PLACED ON
THE LOWER RIGHT HAND CORNER OF EACH SHEET.
ADD UTILITIES CONTACT ANNE URENDA, P.E., 804-748-1343, URE
AA@CHESTERFIELD.GOV ON THE COVER SHEET.
DOES THE BUILDING ADDITION INCLUDE ADDITIONAL FIXTURES? T
WATER METER SIZING FORM SHOULD INCLUDE EXISTING AND PROPO
D FIXTURES. IF NO ADDITIONAL FIXTURES, ADD NOTE STATING A
FIXTURES ARE EXISTING.
FILL IN PART B OF THE WATER METER SIZING FORM. DOMESTIC D
AND IS 20 GPM AND ACTUAL METER SIZE BASED ON DEMAND IS 5/8
NCH.
ADD A NOTE TO THE WATER METER SIZING FORM STATING THERE IS
N EXISTING 1-INCH METER.
NEW LANDSCAPING HAS BEEN PROPOSED. IF IRRIGATION IS
REQUIRED FOR THESE AREAS, PLEASE ADD IRRIGATION DEMAND TO
TER METER SIZING FORM.
AFTER FINAL SITE PLAN APPROVAL, SUBMIT 3 SETS OF THE APPRO
D PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FOR OUR USE D
ING CONSTRUCTION INSPECTION. THIS IS IN ADDITION TO THE O
APPROVED SET FROM PLANNING (4 TOTAL SETS).
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA/748-1343
NAME OF PLAN : SITE IMPROVEMENTS FOR CUSTOM METAL FABR
ADDRESS : 7601 WHITEPINE ROAD
SUBMISSION DATE : 3/14/17
PLAN DATED : 3/9/17
REVIEW DATE : 3/22/17
SITE PLAN NO. : 17PR0198
COMMENTS : 2ND REVIEW-APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: CUSTOM METAL FABRICATORS
SITE PLAN NUMBER: 17PR0198
LATEST PLAN DATE: 12/27/16
DEPT. REC'D. DATE: 01/09/17
SUBMITTAL NUMBER: ONE
REVIEW DATE: 01/10/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: CUSTOM METAL FABRICATORS
SITE PLAN NUMBER: 17PR0198
LATEST PLAN DATE: 03/09/17
DEPT. REC'D. DATE: 03/20/17
SUBMITTAL NUMBER: TWO
REVIEW DATE: 03/30/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------CUSTOM METAL FABRICATORS -
SITE PLAN NUMBER----------17PR0198
ADDRESS-------------------7601 WHITEPINE ROAD
LATEST PLAN DATE----------12/21/16
DEPT. REC'D. DATE---------12/28/16
SUBMITTAL NUMBER----------1
REVIEW DATE---------------01/30/17
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------NO
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----SUBMITTED
ARCHITECTURAL ELEVATIONS--PDF SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT SUBMITTED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A
COMPLETE RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE
PLANNING DEPARTMENT. BELOW EACH COMMENT DESCRIBE HOW YOU
HAVE ADDRESSED EACH REVIEW COMMENT. INDICATE WHICH SHEETS
SHOW THE REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF
REVIEW COMMENTS.
2. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER 17PR0198 I
THE LOWER RIGHT CORNER OF EACH SHEET.
3. FOR COUNTY INDEXING PURPOSES CHANGE THE TITLE ON THE
DRAWING SET TO 'CUSTOM METAL FABRICATORS - BUILDING
ADDITION AND PARKING MODIFICATIONS'
4. ON THE COVER SHEET ADD THE CASE NUMBERS OF THE CURRENT
ZONING CASE AND THE CASE REQUESTING RELIEF FROM THE AIRPOR
INDUSTRIAL PARK RESTRICTIVE COVENANTS THAT ARE TO BE
SUBMITTED TO PLANNING COMMISSION AND BOARD OF SUPERVISORS
FOR SETBACK EXCEPTIONS.
5. NOTE THAT SITE PLAN APPROVAL CANNOT BE GRANTED UNTIL
APPROVAL BY THE BOARD OF SUPERVISORS OF EXCEPTIONS TO
SETBACK REQUIREMENTS AS DEFINED IN BOTH THE AIRPORT
INDUSTRIAL PARK RESTRICTIVE COVENANTS AND THE COUNTY ZONIN
ORDINANCE.
6. ON THE SITE LAYOUT PLAN AND LANDSCAPE PLAN ADD THE
FOLLOWING NOTES RELATED TO SETBACKS:
"SETBACKS SHOWN ARE PROVIDED PER THE AIRPARK INDUSTRIAL
PARK RESTRICTIVE COVENANTS 90CR001. EXCEPTIONS TO FRONT,
SIDE, AND REAR YARD SETBACKS HAVE BEEN GRANTED BY THE BOAR
OF SUPERVISORS PER CASE # ________"
"EXCEPTIONS TO SETBACK REQUIREMENTS PER THE ZONING
ORDINANCE (NOT SHOWN ON THESE PLANS) HAVE BEEN GRANTED BY
THE BOARD OF SUPERVISORS PER CASE # ________"
7. LABEL THE HANDICAP PARKING SPACE PROVIDED ON THE SITE
LAYOUT PLAN. PROVIDE A BUMPER BLOCK AND HANDICAP PARKING
SIGN. PROVIDE DETAILS FOR THE BUMPER BLOCK AND PARKING
SIGN.
8. ON THE SITE PLAN AND LANDSCAPE PLAN, HATCH AND LABEL
AREAS WITH THE SQUARE FOOTAGE PROVIDED FOR INTERIOR PARKIN
LOT LANDSCAPING.
9. ONE LARGE AND ONE SMALL TREE ARE REQUIRED FOR INTERIOR
PARKING LOT LANDSCAPING. LARGE TREES HAVE BEEN PROVIDED. I
PLACE OF THE LONDON PLANE TREES AROUND THE DUMPSTER, ADD A
SMALL TREE, SUCH AS A REDBUD IN THE ISLAND NEAR THE
DUMPSTER, OUTSIDE OF THE SETBACK. FOR DUMPSTER SCREENING,
USE 5 EVERGREEN TREES, SUCH AS HOLLIES THAT REACH MIN. 8-1
FEET HT. AT MATURITY AND ARE 7 FEET HT. AT INSTALLATION.
10. ON THE LANDSCAPE PLAN WHERE SETBACKS ARE SHOWN, LABEL
THE PERIMETER LANDSCAPE TREATMENT REQUIRED FOR EACH YARD
SETBACK.
11. PER SECTION 19.1-27(E), LANDSCAPE PLANS SHALL BE
CERTIFIED BY A STATE OF VIRGINIA REGISTERED LANDSCAPE
ARCHITECT, NURSERYMAN OR LANDSCAPE DESIGNER. THE COUNTY CA
NOT REVIEW THE LANDSCAPE PLAN UNTIL IT IS CERTIFIED PER
THIS REQUIREMENT.
12. ALL TREES WITHIN THE SETBACK FROM A PUBLIC RIGHT OF WA
SHALL BE RETAINED UNLESS REMOVAL IS NECESSARY TO
ACCOMMODATE VEHICULAR ACCESS AND/OR UTILITIES THAT RUN
GENERALLY PERPENDICULAR THROUGH THE SETBACK. THESE TREE
SAVE AREAS SHALL BE SHOWN WITH TREE PROTECTION FENCING ON
THE EROSION CONTROL, GRADING AND LANDSCAPE PLANS. REDUCE
THE AREA OF CLEARING AND DISTURBANCE IN THE WOODED FRONT
YARD SETBACK AT THE ENTRANCE OFF VIRGINIA PINE COURT TO TH
MAXIMUM EXTENT POSSIBLE.
13. HEALTHY EXISTING TREES MAY BE CREDITED TOWARD PLANTING
REQUIREMENTS SO LONG AS EXISTING VEGETATION IS REASONABLY
DISTRIBUTED THROUGHOUT THE LENGTH OF THE SETBACK AREA.
14. REMOVAL OF EXISTING TREES DURING CONSTRUCTION WITHIN
THE SETBACK OR BUFFER WITHOUT WRITTEN APPROVAL FROM THE
PLANNING DEPARTMENT SHALL RESULT IN TWO TREES BEING
PLANTING FOR EACH TREE REMOVED
15. ANY EXISTING TREES IN SETBACKS THAT ARE APPROVED FOR
REMOVAL SHALL BE SHOWN AS SUCH ON THE EROSION CONTROL,
GRADING AND LANDSCAPE PLANS.
16. IN THE SIDE YARD SETBACK ON THE SOUTHWEST PROPERTY
LINE, INDICATE WHETHER EXISTING VEGETATION WILL BE RETAINE
OR REMOVED. PROVIDE PERIMETER LANDSCAPE B WITHIN THIS
SETBACK USING EXISTING OR PROPOSED VEGETATION.
17. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A READILY
AVAILABLE WATER SUPPLY. THE COUNTY ACCEPTS EITHER YARD
HYDRANTS AND/OR HOSE BIBS WITHIN 100 FEET OF ALL NEW
PLANTINGS OR AN IRRIGATION SYSTEM FOR ALL AREAS OF NEW
PLANTINGS. SHOW LOCATION OF HYDRANTS, BIBS OR IRRIGATION
SLEEVES. THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE WITH
WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE SPECIES.
INSURE WATER INFORMATION IS SUPPLIED ON UTILITY DEPARTMENT
METER SIZING FORMS. 19.1-249.B
18. INSTALLATION SURETY: PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, THE REQUIRED LANDSCAPING IS COMPLETED; O
A FORM OF SURETY SATISFACTORY TO THE DIRECTOR OF PLANNING
IS SUBMITTED IN AN AMOUNT EQUAL TO THE COST OF COMPLETING
THE REQUIRED LANDSCAPING. IF SURETY HAS BEEN SUBMITTED, TH
REQUIRED LANDSCAPING SHALL BE INSTALLED BASED UPON THE
APPROVED PHASING PLAN OR DURING THE FIRST PLANTING SEASON
FOLLOWING DATE OF ISSUANCE OF THE SURETY. 19.1-248.A.2
19. MAINTENANCE GUARANTEE: PRIOR TO RECEIVING AN OCCUPANCY
PERMIT, THE APPLICANT SHALL PROVIDE A LETTER OF GUARANTEE
(COUNTY FORMAT) TO INSURE REPLACEMENT OF UNHEALTHY, DYING,
DEAD OR POLLARDED LANDSCAPING WITHIN THE FIRST YEAR OF
INSTALLATION. 19.1-248.B
20. IF NEW EXTERIOR SITE LIGHTING IS TO BE INSTALLED, SHOW
THE LOCATION OF POLE AND BUILDING MOUNTED FIXTURES ON THE
LANDSCAPE PLAN OR ON A SEPARATE LIGHTING PLAN. PROVIDE
FIXTURE INFORMATION CUT-SHEETS. ALL SPECIFIED FIXTURES ARE
TO BE FULL CUT OFF, DOWNWARD DIRECTIONAL, AND DIRECT LIGHT
SOURCE SHIELDED FROM VIEW.
21. PROVIDE (2) HARDCOPY ARCHITECTURAL ELEVATIONS. THE
COLOR OF THE ADDITION IS TO MATCH THE EXISTING BUILDING.
PROVIDE COLOR RENDERED ELEVATIONS OR ADD A NOTE TO THE
ELEVATIONS THAT COLORS ARE TO MATCH.
22. PER SEC. 19.1-317.D, MECHANICAL EQUIPMENT, WHETHER
ROOF-TOP OR GROUND LEVEL, SHALL BE SHIELDED AND SCREENED
FROM PUBLIC VIEW AND DESIGNED TO BE PERCEIVED AS AN
INTEGRAL PART OF THE BUILDING EXCEPT AS ALLOWED IN I-2 AND
I-3 DISTRICTS. SHOW ALL UNITS IN RELIEF BEHIND PARAPETS
AND/OR WALLS USED FOR SCREENING TO SHOW THAT UNITS ARE
FULLY SCREENED. 19.1-317.D
23. IF ROOF TOP UNITS ARE PROPOSED, ON THE ARCHITECTURAL
ELEVATIONS, SHOW IN RELIEF USING A DASHED LINE THE LOCATIO
OF ROOF TOP MECHANICAL UNITS IN RELATION TO THE PARAPET
WALL. IF THE PLANNING DEPARTMENT DETERMINES THAT UNITS ARE
VISIBLE TO THE PUBLIC, THE PARAPETS SHALL BE EXTENDED UNTI
THE SCREENING IS ACCOMPLISHED, BUT NO HIGHER THAN THE TOP
OF THE RTU'S. THIS SHALL BE REQUIRED PRIOR TO THE RELEASE
OF A TEMPORARY CERTIFICATE OF OCCUPANCY, OR A BOND PLACED
WITH THE COUNTY FOR THE COST OF THE ADDITIONAL BUILDING.
19.1-317.D
**********************************************************
.
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------CUSTOM METAL FABRICATORS
SITE PLAN NUMBER----------17PR0198
ADDRESS-------------------7601 WHITEPINE ROAD
LATEST PLAN DATE----------03/09/17
DEPT. REC'D. DATE---------03/13/17
SUBMITTAL NUMBER----------2
REVIEW DATE---------------03/30/17
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------YES
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----SUBMITTED
ARCHITECTURAL ELEVATIONS--SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT SUBMITTED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS.
RESUBMIT 10 FULL SETS AND ONE COPY OF THE SITE PLAN
SHEET TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW.
PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH
COMMENT DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW
PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH
COMMENT DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW
COMMENT. INDICATE WHICH SHEETS SHOW THE REQUIRED
CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE ANY
CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
2. SETBACKS AS REQUIRED BY THE AIRPORT COVENANTS ARE
CORRECTLY SHOWN ALL SHEETS EXCEPT C2, EXISTING SITE
CONDITIONS. CORRECT THE SIDE AND REAR YARD SETBACKS ON
THIS SHEET.
3. ADD A NORTH ARROW TO THE LANDSCAPE PLAN.
4. INDICATE HEIGHT IN THE PLANT SCHEDULE, NOT CALIPER,
FOR EVERGREEN TREES.
5. AMERICAN HOLLY SELECTED FOR THE EVERGREENS AT THE
DUMPSTER GROW TOO LARGE TO BE SPACED AT 5 FEET ON
CENTER. INSTEAD USE LITTLE GEM MAGNOLIA SPACED AT 6 FEET
ON CENTER SPECIFIED AT 7 FEET HEIGHT.
6. PER SECTION 19.1-27(E), LANDSCAPE PLANS SHALL BE
CERTIFIED BY A STATE OF VIRGINIA REGISTERED LANDSCAPE
ARCHITECT, NURSERYMAN OR LANDSCAPE DESIGNER. THE COUNTY
CAN NOT REVIEW THE LANDSCAPE PLAN UNTIL IT IS CERTIFIED
PER THIS REQUIREMENT.
7. HEALTHY EXISTING TREES MAY BE CREDITED TOWARD
PLANTING REQUIREMENTS SO LONG AS EXISTING VEGETATION IS
REASONABLY DISTRIBUTED THROUGHOUT THE LENGTH OF THE
SETBACK AREA.
8. REMOVAL OF EXISTING TREES DURING CONSTRUCTION WITHIN
THE SETBACK OR BUFFER WITHOUT WRITTEN APPROVAL FROM THE
PLANNING DEPARTMENT SHALL RESULT IN TWO TREES BEING
PLANTING FOR EACH TREE REMOVED
9. EXISTING VEGETATION IS SHOWN AS TO BE REMOVED IN THE
290 FOOT SIDE YARD SETBACK TO ALLOW FOR THE BUILDING
ADDITION AND ASSOCIATED GRADING. SINCE ADDING LARGE
TREES BETWEEN THE BUILDING ADDITION AND PROPERTY LINE IS
NOT FEASIBLE, PERIMETER LANDSCAPE B CAN BE USED IN THIS
SETBACK WITH THE FOLLOWING ADJUSTMENTS: 6 SMALL
DECIDUOUS TREES SPACED ALONG BACK OF BUILDING (1/50 FT),
4 LARGE DECIDUOUS TREES NEAR THE ENTRANCE (1/50 FT - 2),
12 EVERGREEN TREES ALONG THE PARKING (1/30 FT +2), AND
20 MEDIUM SHRUBS NEAR THE ENTRANCE (1/15 FT). THE ROOF
DRAIN LINE WILL NEED TO BE SHIFTED TO TOWARD THE CURB OR
THE PROPERTY LINE TO ALLOW FOR PLANTING AREA. A SKETCH
SHOWING THE LAYOUT OF THE SETBACK PLANTINGS CAN BE
PROVIDED BY PLANNING.
10. IN THE 250 FOOT REAR YARD SETBACK, EXISTING
VEGETATION IS SHOWN TO BE SAVED TO MEET THE PERIMETER
LANDSCAPE B REQUIREMENT. IF THE REQUIREMENT IS NOT MET
WITH PRESERVED VEGETATION AT THE TIME OF OCCUPANCY
INSPECTION, THEN SUPPLEMENTAL PLANT MATERIAL MAY BE
REQUIRED.
11. DROUGHT TOLERANT PLANTS HAVE BEEN PROVIDED. NO
IRRIGATION SYSTEM IS REQUIRED. REGULAR WATERING WILL BE
NEEDED DURING THE FIRST GROWING SEASON AFTER PLANTING
FOR PROPER ESTABLISHMENT AND LONG TERM SURVIVAL.
12. ADD A NOTE TO THE LANDSCAPE PLAN THAT DROUGHT
TOLERANT PLANTS USED HAVE BEEN APPROVED BY CHESTERFIELD
COUNTY PLANNING AND IRRIGATION IS NOT REQUIRED.
13. REQUIRED LANDSCAPING WHICH IS REMOVED, BECOMES
UNHEALTHY OR DIES, OR IS POLLARDED SHALL BE REPLACED
DURING THE NEXT PLANTING SEASON. 19.1-249.
14. INSTALLATION SURETY: PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, THE REQUIRED LANDSCAPING IS COMPLETED; O
A FORM OF SURETY SATISFACTORY TO THE DIRECTOR OF PLANNING
IS SUBMITTED IN AN AMOUNT EQUAL TO THE COST OF COMPLETING
THE REQUIRED LANDSCAPING. IF SURETY HAS BEEN SUBMITTED, TH
REQUIRED LANDSCAPING SHALL BE INSTALLED BASED UPON THE
APPROVED PHASING PLAN OR DURING THE FIRST PLANTING SEASON
FOLLOWING DATE OF ISSUANCE OF THE SURETY. 19.1-248.A.2
15. MAINTENANCE GUARANTEE: PRIOR TO RECEIVING AN OCCUPANCY
PERMIT, THE APPLICANT SHALL PROVIDE A LETTER OF GUARANTEE
(COUNTY FORMAT) TO INSURE REPLACEMENT OF UNHEALTHY, DYING,
DEAD OR POLLARDED LANDSCAPING WITHIN THE FIRST YEAR OF
INSTALLATION. 19.1-248.B
**********************************************************
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : SITE IMP. FOR CUSTOM METAL FABR.
CASE NUMBER : 17PR0198
LATEST PLAN DATE : 12/27/16
RECEIVED DATE : 1/11/17
SUBMITTAL NUMBER : 1
REVIEW DATE : 1/26/17
ADDRESS : 7601 WHITEPINE RD
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. THE PARCEL BOUNDARY SURVEY IS INCOMPLETE. THE CURVE
DATA IS MISSING AT THE CORNER OF WHITEPINE RD AND
VIRGINIA PINE CT.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : SITE IMP. FOR CUSTOM METAL FABR.
CASE NUMBER : 17PR0198
LATEST PLAN DATE : 3/9/17
RECEIVED DATE : 3/17/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 3/31/17
ADDRESS : 7601 WHITEPINE RD
STATUS : APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: SITE IMP. FOR CUSTOM METAL FABR.
SITE PLAN NUMBER: 17PR0198
ADDRESS: 7601 WHITEPINE ROAD
LATEST PLAN DATE: 12/27/16
DEPT. REC'D. DATE: 1/10/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 1/27/17
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. PROVIDE DETAILS AS TO THE METHOD TO BE USED TO PROVIDE
ACCESS TO ALL EXTERIOR POINTS OF THE BUILDING FROM
WITHIN 150 FEET OF AN APPROVED EMERGENCY FIRE APPARATUS
ACCESS ROADWAY. SEE THE 2012 INTERNATIONAL FIRE CODE,
SECTION 503.1.1 FOR CODE INFORMATION AND EXCEPTIONS.
IN ACCORDANCE WITH THE PROVISIONS OF THE INTERNATIONAL
FIRE CODE, SECTION 503, 503.1 THROUGH 503.1.3, FIRE LANES
BE PROVIDED. THE MINIMUM UNOBSTRUCTED CLEAR WIDTH SHALL
BE TWENTY FEET. THE MINIMUM REQUIRED VERTICAL CLEARANCE
SHALL BE THIRTEEN-FEET SIX-INCHES
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: SITE IMP. FOR CUSTOM METAL FABR.
SITE PLAN NUMBER: 17PR0198
ADDRESS: 7601 WHITEPINE ROAD
LATEST PLAN DATE: 3/9/17
DEPT. REC'D. DATE: 3/16/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 3/20/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED SITE PLAN IS APPROVED AS SUBMITTED.