Thanksgiving Holiday Closings... MORE

Hover here for Site Tools
Site Plan Review Comments
All Site Plan Review Comments for Case # 17PR0178
Modify comments view for Case # 17PR0178

Go to Case Selection Form or Go to Project List

 
CASE NO: 17PR0178 STATUS: PENDING APPROVAL
PROJECT NAME: HP WAY PARKING EXPAN - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: INDUSTRIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 11/16/16 12/12/16 ******** ********
ENVIR.ENGR.-: 02 04/12/17 05/03/17 ******** 12/13/16 DLD 706-2031
FIRE DEPT.--: 02 04/12/17 05/03/17 ******** 04/18/17 AWB 717-6167
MAPPING/GIS-: 02 04/12/17 05/03/17 ******** 02/03/17 AMJ 768-7549
PLANNING----: 02 04/12/17 05/03/17 ******** 05/04/17 L M 717-6836
TRANSPORT.--: 02 04/12/17 05/03/17 ******** 04/19/17 SJA 751-4461
UTIL.PLAN.--: 02 04/12/17 05/03/17 ******** ********
UTILITIES---: 02 04/12/17 05/03/17 AMENDED* 05/11/17 JB 768-7592
UTIL.R.O.W.-: 02 04/12/17 05/03/17 ******** ********
VDOT--------: 02 04/12/17 05/03/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E./748-1338
NAME OF PLAN : 500 - 600 HP WAY
ADDRESS : 600 HP WAY
SUBMISSION DATE : 11/21/16
PLAN DATED : 11/09/16
REVIEW DATE : 11/29/16
SITE PLAN NO. : 17PR0178
COMMENTS : 1ST REVIEW-APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
1. NO IMPACTS TO UTILITIES.
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : ANNE URENDA, P.E./748-1343
NAME OF PLAN : HP WAY PARKING EXPANSION
ADDRESS : 600 HP WAY
SUBMISSION DATE : 4/14/17
PLAN DATED : 3/31/17
REVIEW DATE : 4/19/17
SITE PLAN NO. : 17PR0178
COMMENTS : 3RD REVIEW-APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
1. NO IMPACTS TO UTILITIES
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: 500-600 HP WAY PARKING EXPANSION
SITE PLAN NUMBER: 17PR0178
LATEST PLAN DATE: 11/09/16
DEPT. REC'D. DATE: 11/22/16
SUBMITTAL NUMBER: ONE
REVIEW DATE: 11/22/16
RECOMMENDATION: APPROVED
NOTE THE COUNTY CLASSIFICATION FOR KINGSTON AVE ON THE PLA
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: HP WAY PARKING EXPANSION
SITE PLAN NUMBER: 17PR0178
LATEST PLAN DATE: 01/09/17
DEPT. REC'D. DATE: 01/12/17
SUBMITTAL NUMBER: TWO
REVIEW DATE: 01/18/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: HP WAY PARKING EXPANSION
SITE PLAN NUMBER: 17PR0178
LATEST PLAN DATE: 03/31/17
DEPT. REC'D. DATE: 04/14/17
SUBMITTAL NUMBER: THREE
REVIEW DATE: 04/19/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : LUIGI MIGNARDI / 717-6836
PLAN NAME : HP WAY
PLAN NUMBER : 17PR0178
ORIGINAL PLAN DATE 11/09/16
REVIEW DATE : 12/12/16
LATEST SUBMISSION DATE : -
ACCEPTED DATE: 11/16/16
SUBMITTAL NUMBER : 1
STATUS : CORRECTIONS REQUIRED
TABLE REVIEW : Y
-----------------------------------------------------
01. SHOW LOCATION AND DIMENSIONS OF HANDICAP
PARKING SPACES AND PEDESTRIAN ACCESS AISLES. PARKING
SPACES ARE TO BE LOCATED AS CLOSE TO THE MAIN BUILDING
ENTRANCE AS POSSIBLE. SHOW CONNECTION OF HANDICAP
ACCESS AISLES TO SIDEWALKS.
CALL OUT ON SHEET C-202 OR ADD A NEW SHEET WHERE
THE NEW HANDICAP SPACES WILL BE PROVIDED
02. INSTALL BUMPER BLOCKS AT ENDS OF PARKING SPACES
BETWEEN HANDICAP ACCESS AISLE AND ENTRANCE TO BUILDING
SO THAT CARS DO NOT ENCROACH INTO HANDICAP PEDESTRIAN PATH
03. SHOW LOCATION AND DETAILS OF HANDICAP PARKING
SIGNAGE.
04. ALL TREES WITHIN THE SETBACK FROM A PUBLIC RIGHT OF WA
SHALL BE RETAINED UNLESS REMOVAL IS NECESSARY TO
ACCOMMODATE VEHICULAR ACCESS AND/OR UTILITIES THAT RUN
GENERALLY PERPENDICULAR THROUGH THE SETBACK. THESE TREE
SAVE AREAS SHALL BE SHOWN ON THE EROSION CONTROL, GRADING
AND LANDSCAPE PLANS.
05. REMOVAL OF EXISTING TREES WITHIN THE SETBACK OR BUFFER
WITHOUT WRITTEN APPROVAL FROM THE PLANNING DEPARTMENT
SHALL RESULT IN TWO TREES BEING PLANTING FOR EACH TREE
REMOVED PER SEC. 19.1-249 (C)2.
06. EACH REVIEW OF DETAILED LANDSCAPE PLANS AFTER
APPROVAL OF THE SITE PLAN INCURS A RESUBMITTAL FEE AND
IS TRACKED AS A SITE PLAN REVIEW UNTIL APPROVED.
APPROVAL MUST BE OBTAINED PRIOR TO TEMPORARY OCCUPANCY
OF THE BUILDING PER SEC. 19.1-246B.
07. PER SEC. 19.1-249, ALL LANDSCAPED AREAS SHALL BE
PROVIDED WITH A READILY AVAILABLE WATER SUPPLY. THE
COUNTY ACCEPTS EITHER YARD HYDRANTS AND/OR HOSE BIBS
WITHIN 100 FEET OF ALL NEW PLANTINGS OR AN IRRIGATION SYST
FOR ALL AREAS OF NEW PLANTINGS.
THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE
WITH WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE
SPECIES. INSURE WATER INFORMATION IS SUPPLIED ON UTILITY
DEPARTMENT METER SIZING FORMS.
08. PER SEC. 19.1-248.B., A FORM OF SURETY SUCH AS A
PERFORMANCE BOND IN AN AMOUNT EQUAL TO 50 PERCENT
OF THE INITIAL INSTALLATION COST OF THE LANDSCAPING
SHALL BE SUBMITTED TO THE PLANNING DEPARTMENT PRIOR TO
THE PLANNING DEPARTMENT'S APPROVAL OF THE OCCUPANCY
PERMIT OR CERTIFICATE OF COMPLETION. WITHIN A YEAR OF
INSTALLATION AND PRIOR TO RELEASE OF THE BOND, THE
PLANNING DEPARTMENT SHALL INSPECT THE LANDSCAPING.
ANY PLANTS MISSING, DEAD, OR IN POOR CONDITION SHALL
BE REPLACED BY THE OWNER OR CONTRACTOR.
09. PER SEC. 19.1-205, SHOW ON THE LANDSCAPE PLAN OR
ADDITIONALLY ON A SEPARATE LIGHTING PLAN THE LOCATION OF A
EXTERIOR SITE LIGHTING MOUNTED ON POLES, THE BUILDING, OR
ON THE GROUND AND HAVE THEM KEYED TO CUT SHEETS FOR EACH
LIGHT FIXTURE SHOWN ON THE PLAN.
10. PER SEC. 19.1-205, SUBMIT A FOOT-CANDLE OUTPUT DIAGRAM
WHENEVER A SITE IS ADJACENT TO A RESIDENTIAL DISTRICT AND
DOCUMENT THAT THE MAXIMUM ILLUMINATION DOES NOT EXCEED
0.5 FOOT-CANDLES AT THE PROPERTY LINE WITH THE RESIDENTIAL
DISTRICT
11. PER SEC. 19.1-205, UNLESS A PROJECT IS APPROVED
FOR ORNAMENTAL PEDESTRIAN-STYLE LIGHTING, ALL LIGHT FIXTUR
SHALL BE OF A DIRECTIONAL TYPE THAT SHIELDS THE LIGHT SOUR
FROM DIRECT VIEW FROM ANY ADJOINING, A, R, R-TH, MH,
TND, OR R-MF DISTRICT OR PUBLIC RIGHT OF WAY.
12. CHECK LOCATION OF POLE LOCATION, ONE MAY BE IN
CONFLICT WITH AN INLET
13. CALL OUT PROPERTY LINES ON ALL PLANS. EITHER WITH
THE PROPER LINE TYPE OR ANNOTATION
14. IN ORDER TO SAVE MORE OF THE BUFFER ALONG MEADOWVILLE
ROAD INCREASE THE BERM ON THE PARKING LOT SIDE TO 2:1 SLOP
15. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER (17PR0017
IN THE LOWER RIGHT CORNER OF EACH SHEET.
----------------------------------------------------------
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : LUIGI MIGNARDI / 717-6836
PLAN NAME : HP WAY
PLAN NUMBER : 17PR0178
ORIGINAL PLAN DATE 11/09/16
REVIEW DATE : 02/06/17
LATEST SUBMISSION DATE : 01/09/17
ACCEPTED DATE: 01/11/17
SUBMITTAL NUMBER : 2
STATUS : APPROVED
TABLE REVIEW : Y
.
01. PER SEC. 19.1-248.B., A FORM OF SURETY SUCH AS A
PERFORMANCE BOND IN AN AMOUNT EQUAL TO 50 PERCENT
OF THE INITIAL INSTALLATION COST OF THE LANDSCAPING SHALL
BE SUBMITTED TO THE PLANNING DEPARTMENT PRIOR TO
THE PLANNING DEPARTMENT'S APPROVAL OF THE OCCUPANCY
PERMIT OR CERTIFICATE OF COMPLETION. WITHIN A YEAR OF
INSTALLATION AND PRIOR TO RELEASE OF THE BOND, THE
PLANNING DEPARTMENT SHALL INSPECT THE LANDSCAPING.
ANY PLANTS MISSING, DEAD, OR IN POOR CONDITION SHALL
BE REPLACED BY THE OWNER OR CONTRACTOR.
.
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : LUIGI MIGNARDI / 717-6836
PLAN NAME : HP WAY
PLAN NUMBER : 17PR0178
ORIGINAL PLAN DATE 11/09/16
REVIEW DATE : 05/04/17
LATEST SUBMISSION DATE : 03/31/17
ACCEPTED DATE: 04/12/17
SUBMITTAL NUMBER : 3
STATUS : APPROVED
TABLE REVIEW : Y
.
01. PER SEC. 19.1-248.B., A FORM OF SURETY SUCH AS A
PERFORMANCE BOND IN AN AMOUNT EQUAL TO 50 PERCENT
OF THE INITIAL INSTALLATION COST OF THE LANDSCAPING SHALL
BE SUBMITTED TO THE PLANNING DEPARTMENT PRIOR TO
THE PLANNING DEPARTMENT'S APPROVAL OF THE OCCUPANCY
PERMIT OR CERTIFICATE OF COMPLETION. WITHIN A YEAR OF
INSTALLATION AND PRIOR TO RELEASE OF THE BOND, THE
PLANNING DEPARTMENT SHALL INSPECT THE LANDSCAPING.
ANY PLANTS MISSING, DEAD, OR IN POOR CONDITION SHALL
BE REPLACED BY THE OWNER OR CONTRACTOR.
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : 500-600 HP WAY PARKING EXP
CASE NUMBER : 17PR0178
LATEST PLAN DATE : 11/9/16
RECEIVED DATE : 11/22/16
SUBMITTAL NUMBER : 1
REVIEW DATE : 12/9/16
ADDRESS :
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY.
2. THE PARCEL BOUNDARY SURVEY IS NOT SHOWN. PLEASE
SUPPLY THE METES AND BOUNDS FOR EVERY SEGMENT ALONG THE
TRAVERSE TO INCLUDE CHORD BEARING AND DISTANCE FOR ALL
NON-TANGENT CURVES. IF THE PARCEL IS TOO LARGE TO
CONVENIENTLY FIT ON ONE SHEET, A LARGER SCALE DRAWING
OF THE BOUNDARY IS ACCEPTABLE.
3. BEARINGS SHOWN ARE NOT INDICATED TO BE NAD83 BEARINGS.
ADD THIS INDICATION TO THE NORTH ARROW.
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : HP WAY PARKING EXPANSION
CASE NUMBER : 17PR0178
LATEST PLAN DATE : 1/9/17
RECEIVED DATE : 1/17/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 2/3/17
STATUS : APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. MORE THAN ONE DIRECTION OF TRAVERSE IS SHOWN.
PLEASE REVISE THE SURVEY TO SHOW ONLY ONE PATH OF
TRAVERSE.
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: 500-600 HP WAY PARKING EXP.
SITE PLAN NUMBER: 17PR0178
ADDRESS: 500 HP WAY
LATEST PLAN DATE: 11/9/16
DEPT. REC'D. DATE: 11/22/16
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 11/22/16
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: 500-600 HP WAY PARKING EXP.
SITE PLAN NUMBER: 17PR0178
ADDRESS: 500 HP WAY
LATEST PLAN DATE: 1/9/17
DEPT. REC'D. DATE: 1/17/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 1/18/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: 500-600 HP WAY PARKING EXP.
SITE PLAN NUMBER: 17PR0178
ADDRESS: 500 HP WAY
LATEST PLAN DATE: 3/31/17
DEPT. REC'D. DATE: 4/17/17
SUBMITTAL NUMBER: 3RD REVIEW
REVIEW DATE: 4/18/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : DUSTIN DUNNAGAN / 706-2061
NAME OF PLAN : 500 - 600 HP WAY PARKING EXPANSION
ADDRESS : 500 - 600 HP WAY
SITE PLAN NO. : 17PR0178
LATEST PLAN DATE : NOVEMBER 09, 2016
DEPT. REC'D DATE : NOVEMBER 21, 2016
SUBMITTAL NUMBER : 1
REVIEW DATE : DECEMBER 12, 2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY. WETLANDS DOCUMENTATION MUST BE
RECEIVED BY THIS DEPARTMENT PRIOR TO ISSUANCE OF THE
LAND DISTURBANCE PERMIT.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. EFFECTIVE JULY 1, 2014, ENFORCEMENT OF THE VIRGINIA
STORMWATER REGULATIONS BECAME THE RESPONSIBILITY OF
THE COUNTY FOR DEVELOPMENT PROJECTS WITHIN
CHESTERFIELD COUNTY. ADDITIONALLY, NEW STATE
STORMWATER REGULATIONS ALSO BECAME EFFECTIVE ON
JULY 1, 2014. LAND DISTURBING ACTIVITIES THAT
OBTAINED A VSMP PERMIT PRIOR TO JULY 1, 2014 MAY
USE THE STORMWATER MANAGEMENT CRITERIA SPECIFIED
IN PART II C (9VAC25-870-93 ET SEQ) FOR TWO PERMIT
CYCLES. PROJECTS GRANDFATHERED UNDER THE PROVISIONS
OF 9VAC25-870-48 MAY FOLLOW THE REQUIREMENTS LISTED
UNDER PART IIC FOR ONE PERMIT CYCLE. ALL OTHER NEW
DEVELOPMENT WILL BE SUBJECT TO THE REQUIREMENTS OF
PART IIB (9VAC25-870-62 TO 9VAC25-870-92).
03. PROVIDE THE FOLLOWING INFORMATION ON THE COVER SHEET:
A. LATITUDE AND LONGITUDE FOR THE PROJECT SITE (IN
DEGREES, MINUTES, SECONDS, TO THE NEAREST 15 SECONDS)
B. NAME OF RECEIVING CHANNEL/WATERS
C. VAHU6 FOUR DIGIT WATERSHED CODE
D. TOTAL ON-SITE IMPERVIOUS COVER IN SQUARE FEET
(EXCLUDING VDOT RIGHTS-OF-WAY AND GRAVELED AREAS)
BROKEN UP BY PHASES AND PARCELS.
04. STEPS STD. ST-1 MUST BE SPECIFIED IN THE TABULAR
DRAINAGE DESCRIPTION OF ANY STRUCTURE OVER 4 FEET IN
HEIGHT. (CL-G&D 20)
05. APPROVAL OF THE SITE PLAN BY THE PRIVATE UTILITY
COMPANY IN RELATION TO ITS EASEMENT AND FACILITIES
THEREIN MUST BE PROVIDED PRIOR TO SITE PLAN APPROVAL.
06. A NOTE MUST BE ADDED TO THE SEQUENCE OF CONSTRUCTION
STATING THAT THE CERTIFIED RESPONSIBLE LAND DISTURBER
(CRLD) MUST ATTEND THE PRE-CONSTRUCTION MEETING.
(CL-EC 5)
07. A NOTE MUST BE ADDED TO THE SEQUENCE OF CONSTRUCTION
STATING THAT THE VSMP CONSTRUCTION ACTIVITY OPERATOR
AND THE ENVIRONMENTAL INSPECTOR (OR AUTHORIZED
REPRESENTATIVE) MUST ATTEND THE PRE-CONSTRUCTION
MEETING.
08. THE CONSTRUCTION ENTRANCE MUST BE GRAPHICALLY SHOWN ON
THE PLANS AND CONSTRUCTED AS WIDE AS THE PROPOSED
PERMANENT ENTRANCE. (CL-EC 9)
09. SAFETY FENCE (STD. & SPEC 3.01) IS REQUIRED AROUND ALL
SEDIMENT TRAPS AND SEDIMENT BASINS. (CL-EC 15)
10. A MINIMUM 10' BREAK MUST BE PROVIDED IN THE LOW AREA O
THE SILT FENCE . THE BREAK MUST BE BACKFILLED WITH
STONE TO WITHIN 1' OF THE TOP OF THE SILT FENCE TO
SERVE AS AN OVERFLOW. A DETAIL MUST BE SHOWN.
(CL-EC 16)
11. NOTES A THRU E OF MINIMUM STANDARD 16 MUST BE PROVIDED
ON THE PLANS. (CL-EC 36)
12. A DETAIL MUST BE SHOWN WHICH PROVIDES FOR PLACEMENT OF
EXCAVATED TRENCH MATERIAL ON THE UPHILL SIDE OF THE
TRENCH WHILE SILT FENCE AND STOCKPILED MATERIALS ARE
PLACED ON THE DOWNSTREAM SIDE. (CL-EC 37)
13. ANY SOIL STOCKPILE AREA MUST BE LOCATED ON THE PLANS.
SILT FENCE MUST BE PROVIDED AROUND THE PERIMETER.
(CL-EC 39)
14. THE FOLLOWING NOTE(S) MUST BE ADDED TO OR ADJACENT TO
THE SEQUENCE OF CONSTRUCTION: (CL-EC 42)
1. AT THE TIME OF THE PRE-CONSTRUCTION MEETING, TWO
STANDARD SIGNS MUST BE INSTALLED ON EACH SIDE OF THE
CONSTRUCTION ACCESS. THESE SIGNS SHOULD STATE EITHER
"CONSTRUCTION ENTRANCE AHEAD" OR "TRUCKS ENTERING
HIGHWAY". (CL-EC 42E)
15. SHOW ON THE FIRST SHEET, USING A HIGHLY VISIBLE NOTE,
HOW COMPLIANCE WITH THE CHESAPEAKE BAY PRESERVATION
ORDINANCE HAS BEEN ACCOMPLISHED. THE NOTE MUST LIST
THE METHOD OF COMPLIANCE TO INCLUDE THE TYPE(S) OF BMP
IF AN OPT-OUT REPORT WAS PERFORMED, THE PERSON
PREPARING THE REPORT, THE DATE OF THE REPORT, AND THE
COUNTY APPROVAL DATE MUST BE SPECIFIED. (CL-CBPA 1)
16. A CBPA COMPLIANCE SHEET(S) IS REQUIRED FOR PROJECTS
UTILIZING PART IIC OF THE CURRENT VSMP REGULATIONS.
(CL-CBPA 3) THE FOLLOWING INFORMATION IS REQUIRED TO B
SHOWN ON THE SHEET(S):
1. THE CBPA/MS-4 COMPLIANCE TABLE. (SEE APPENDIX D OF TH
CHESAPEAKE BAY CHAPTER IN THE ENVIRONMENTAL ENGINEERIN
REFERENCE MANUAL) (CL-CBPA 3A)
2. PERCENT IMPERVIOUS CALCULATIONS/ASSUMPTIONS.
(CL-CBPA 3G)
3. INCREMENTAL DRAINAGE AREAS TO EACH BMP, THE IMPERVIOUS
AREA WITHIN EACH DRAINAGE AREA, AND THE PERCENT
IMPERVIOUS AREA OF EACH BMP DRAINAGE AREA. (CL-CBPA 3H
17. PRIOR TO PLAN APPROVAL, DOCUMENTATION OF THE OWNER'S
ACQUISITION OF THE NONPOINT NUTRIENT OFFSETS MUST BE
PROVIDED IN A CERTIFICATION FROM THE OFFSET BROKER
DOCUMENTING THE NUMBER OF PHOSPHOROUS NONPOINT NUTRIEN
OFFSETS ACQUIRED AND THE ASSOCIATED RATIO OF NITROGEN
NONPOINT NUTRIENT OFFSETS AT THE OFFSET GENERATING
FACILITY.
18. NOTE THAT THE NONPOINT NUTRIENT OFFSETS USED FOR WATER
QUALITY COMPLIANCE MUST BE GENERATED IN THE SAME OR
ADJACENT EIGHT DIGIT HYDROLOGIC UNIT CODE AS DEFINED B
THE UNITED STATES GEOLOGICAL SURVEY AS THE SITE.
NONPOINT NUTRIENT OFFSETS OUTSIDE THE SAME OR ADJACENT
EIGHT DIGIT HYDROLOGIC UNIT CODE MAY ONLY BE USED IF I
IS DETERMINED THAT NO NONPOINT NUTRIENT OFFSETS ARE
AVAILABLE WITHIN THE SAME OR ADJACENT EIGHT DIGIT
HYDROLOGIC UNIT CODE. IN SUCH CASES, THE NONPOINT
NUTRIENT OFFSETS MUST BE GENERATED WITHIN THE SAME
TRIBUTARY. PROVIDE A HYDROLOGIC UNIT MAP SHOWING THE
LOCATION OF THE PROJECT AND THE OFFSET GENERATING
FACILITY.
19. THE CBPA COMPLIANCE NOTE MUST SPECIFY THE NUMBER OF
PHOSPHOROUS NONPOINT NUTRIENT OFFSETS ACQUIRED
AND THE NAME OF THE OFFSET GENERATING FACILITY.
20. SHEET C201:
A) INCLUDE EXISTING STORM SEWER STRUCTURES IN THE STOR
SEWER TABLE.
B) PROVIDE SPREAD CALCULATIONS FOR EXISTING INLETS
RECEIVING RUNOFF FROM THE SITE.
21. ON SHEET C202, IT APPEARS SOME OF THE DRAINAGE AREA FO
THE SITE IS DISCHARGING TO EXISTING INLETS. ENSURE TH
DRAINAGE AREAS SHOWN INCLUDE UPDATED DRAINAGE AREAS FO
OFFSITE INLETS RECEIVING RUNOFF FROM THE SITE.
22. SHEET C401:
A) UPDATE NOTE 9 TO THE CURRENT REGULATIONS.
B) PROVIDE A DIVERSION DIKE OR DIVERSION TO THE WESTER
EDGE OF THE SITE IN ORDER TO MAXIMIZE THE DRAINAGE
AREA GOING TO THE SEDIMENT TRAP.
C) PROVIDE NOTE TO CONTACT ENVIRONMENTAL ENGINEERING
INSPECTOR PRIOR TO PROCEEDING TO PHASE II.
D) PROVIDE INLET PROTECTION FOR THE EXISTING GRATE
INLET TO THE SOUTH EAST OF THE SITE.
E) PROVIDE GRADING AND CALCULATIONS FOR THE DIVERSIONS
23. SHEET C402:
A) PROVIDE NOTE THAT THE BERM IS TO BE FREE OF
CONSTRUCTION DEBRIS SUCH AS STUMPS, CONCRETE,
ASPHALT, ETC.
B) IT APPEARS THERE ARE TWO DIFFERENT SET OF CONTOURS
BEING SHOWN IN THE AREA OF THE SEDIMENT TRAP.
CLARIFY.
24. SHEET C403:
A) ENSURE ES-1 IS REFERENCING THE CURRENT REGULATIONS.
B) PROVIDE MS-19 TABLE AND IDENTIFY OUTFALLS.
25. ON SHEET L-801, IT IS SUGGESTED TO REPLACE THE MAPLE
TREE BY STRUCTURE 2 WITH AN OAK TREE TO PREVENT
INTERFERENCE WITH THE STORM SEWER SYSTEM.
26. IT APPEARS FROM THE 98 PLAN THAT THIS AREA WAS OPTED
OUT OF THE CBPA AND IS LIKELY NOT INCLUDED IN THE WATE
QUALITY CALCULATIONS. IF THIS SITE IS TO BE CONSIDERE
AS PART IIC, EITHER DEMONSTRATE THE PONDS CAN HANDLE
THE ADDITIONAL CBPA AREA OR PROVIDE OFFSITE NUTRIENT
CREDIT PURCHASE.
27. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
28. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, THE
NAME, "WALK-IN" ADDRESS, AND TELEPHONE NUMBER OF
A LOCAL REGISTERED AGENT REPRESENTING THE OWNER FOR
SERVICE OF PROCESS MUST BE PROVIDED ON THE "APPOINTMEN
OF AGENT FOR SERVICE OF PROCESS" FORM FOUND ON THE
CHESTERFIELD COUNTY ENVIRONMENTAL ENGINEERING WEBPAGE.
(CL-GENERAL 12)
29. THE POLLUTION PREVENTION PLAN MUST BE PROVIDED TO THE
ENVIRONMENTAL ENGINEERING INSPECTOR PRIOR TO ISSUANCE
OF A LAND DISTURBANCE PERMIT. THE CHESTERFIELD COUNTY
POLLUTION PREVENTION PLAN SHEET MAY BE PROVIDED IN THE
CONSTRUCTION PLANS (THIS IS AVAILABLE ON THE
ENVIRONMENTAL ENGINEERING DOCUMENTS AND FORMS WEBPAGE)
30. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
31. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
32. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. THE VIRGINIA STORMWATER MANAGEMENT PERMIT (VSMP)
REGISTRATION STATEMENT AND FEE OF $2700
E. THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) BOOK
F. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================

Modify comments view for case # 17PR0178



Go to Case Selection Form or Go to Project List