All Site Plan Review Comments for Case # 17PR0141
Modify comments view for Case # 17PR0141

Go to Case Selection Form or Go to Project List

 
CASE NO: 17PR0141 STATUS: APPROVED - ADMIN
PROJECT NAME: IRONBRIDGE SPORTS PA - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 09/28/16 10/19/16 ******** ********
ENVIR.ENGR.-: 01 11/28/16 12/19/16 COMPLETE 12/15/16 DLD 706-2031
FIRE DEPT.--: 01 11/28/16 12/19/16 COMPLETE 12/16/16 AWB 717-6167
MAPPING/GIS-: 01 11/28/16 12/19/16 COMPLETE 12/16/16 AMJ 768-7549
PLANNING----: 01 11/28/16 12/19/16 COMPLETE 04/27/17 CH 717-6042
TRANSPORT.--: 01 11/28/16 12/19/16 COMPLETE 12/02/16 SJA 751-4461
UTIL.PLAN.--: 01 11/28/16 12/19/16 AMENDED* 04/27/17 TVM 751-4435
UTILITIES---: 01 11/28/16 12/19/16 ******** ********
UTIL.R.O.W.-: 01 11/28/16 12/19/16 ******** ********
VDOT--------: 01 11/28/16 12/19/16 ******** ********
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE #: W.B. PAYNE III/751-4336
NAME OF PLAN: IRONBRIDGE SPORTS PARK 2016
IMPROVEMENTS
ADDRESS: 11400 IRONBRIDGE ROAD
SUBMISSION DATE: 12/02/16
PLAN DATED: 11/23/16
REVIEW DATE: 12/13/16
SITE PLAN NUMBER: 17PR0141
COMMENTS: 2ND REVIEW - NOT APPROVED
TABLE REVIEW:
PLAT PROCESS:
1. CHESTERFIELD UTILITIES PREFERS THE USE OF DOGHOUSE
(STRADDLE) MH'S IN LIEU OF CUT-IN MH'S DUE TO THE FACT
THAT NORMAL FLOW TYPICALLY WILL NOT NEED TO BE INTERRUPTED
DURING INSTALLATION SINCE THERE IS NOT A STANDARD DETAIL
CURRENTLY AVAILABLE IN THE SPECIFICATIONS, PLEASE ADD BOTH
ENCLOSED "UNOFFICIAL" DETAILS TO THE PLAN AND CHANGE THE
PLAN AND PROFILE TO REFLECT THE DOGHOUSE (STRADDLING) MH.
2.ADD THE REQUIRED MANHOLE INSERTS TO THE QUANTITIES.
3.RE: THE WM, PLEASE MAKE THE FOLLOWING CHANGES:
A. ADD A NOTE TO SHEET C-2 INDICATING THAT THE EXISTING WM
IS 1".
B. REVISE THE NOTE ON SHEET C-6 TO STATE "REVISE EXISTING
1" WATER METER TO 1.5" WATER METER." IT SHOULD ALSO BE
NOTED THE CONTRACTOR IS TO REMOVE THE EXISTING 1" METER BO
AND SETTER THROUGH COORDINATION WITH THE UTILITIES INSPECT
AND INSTALL A NEW BOX AND SETTER PER DETAILS MET-7.
C. REMOVE THE ERRANT MET-7 DETAIL SHOWN ON SHEET C-9
AND ADD BOTH CURRENT MET-7 DETAILS (DATED FEBRUARY 2012)
4. RE: COMMENT 8A. FROM THE OCTOBER 10, 2016 UTILITIES
REVIEW LETTER, PLEASE BE ADVISED THE PROJECT WILL NOT BE
RELEASED TO CONSTRUCTION UNTIL A MSF REFLECTING ALL FIXTUR
USES SERVED BY THE DOMESTIC METER HAVE BEEN ACCOUNTED
FOR ON THE FORM.
5. ADD A NOTE TO THE PLAN AND PROFILE THAT THE CONTRACTOR
TO MODIFY MH E1 BY REMOVING THE TOP STEP PER DETAIL
MAN-17, THEN ADD DETAIL MAN-17 TO THE PLAN.
6. RE: COMMENT 15 FROM THE OCTOBER 10, 2016 UTILITIES
REVIEW LETTER, ADD THE FLOW TEST INFORMATION RESULTS FOR
WATER FLOW TO THE PLAN.
7. CALCULATE THE LENGTH OF MECHANICAL THRUST RESTRAINT FOR
THE END OF THE PROPOSED WATERLINE AND ADD TO THE PROFILE.
ADDITIONALLY, ADD A NOTE THAT ALL FITTINGS ARE TO BE
8. CORRECT THE LOCATION OF THE TEE AND GV AT STA 10+00 OF
THE PROPOSED WATERLINE SO THEY ARE LOCATED ON THE PROPOSED
LINE, NOT THE EXISTING MAIN.
9. ADD (AND LABEL) A 2" BO TO THE END OF THE 8" WATERLINE
STUB.
THE OWNER IS REQUIRED TO ENTER INTO A COUNTY UTILITIES
CONTRACT PRIOR TO THE START OF CONSTRUCTION.
AFTER FINAL SITE PLAN APPROVAL, A TOTAL OF FOUR SETS OF TH
APPROVED PLANS MUST BE SUBMITTED TO THE UTILITIES
DEPARTMENT FOR OUR USE DURING CONSTRUCTION INSPECTION.
ENCL: DOGHOUSE (STRADDLE) MANHOLE DETAILS (SEPARATE
EMAIL)
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE #: W.B. PAYNE III/751-4336
NAME OF PLAN: IRONBRIDGE SPORTS PARK 2016 IMPROVEMENTS
ADDRESS: 11400 IRONBRIDGE ROAD
SUBMISSION DATE: 4/26/17
PLAN DATED: 4/26/17
REVIEW DATE: 4/26/17
SITE PLAN NUMBER: 17PR0141
COMMENTS: APPROVED AT TABLE REVIEW
THIS PLAN IS APPROVABLE BY UTILITIES AND SUPERSEDES THE PR
IOUSLY APPROVED PLAN DATED 1/25/17.
THE OWNER IS NOT REQUIRED TO ENTER INTO A COUNTY UTILITIES
CONTRACT HOWEVER A BID PROPOSAL MUST BE SUBMITTED TO
UTILITIES PRIOR TO RELEASE OF THE PROJECT TO CONSTRUCTION.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: IRONBRIDGE SPORTS PARK
SITE PLAN NUMBER: 17PR0141
LATEST PLAN DATE: 09/20/16
DEPT. REC'D. DATE: 09/30/16
SUBMITTAL NUMBER: ONE
REVIEW DATE: 10/17/16
RECOMMENDATION: NOT APPROVED
IN ACCORDANCE WITH PROFFERED CONDITION 4 OF ZONING CASE
90SN0304, PROVIDE AN UPDATED PHASING PLAN ADDRESSING ROAD
IMPROVEMENTS REQUIRED PER PROFFERED CONDITION 3. TO DATE,
THE ROAD IMPROVEMENTS REMAINING ARE A SEPARATE RIGHT TURN
LANE AT THE APPROVED ACCESS TO ROUTE 10 (3A) AND FULL COST
OF TRAFFIC SIGNALIZATION, IF WARRANTED (3B).
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: IRONBRIDGE SPORTS PARK
SITE PLAN NUMBER: 17PR0141
LATEST PLAN DATE: 11/23/16
DEPT. REC'D. DATE: 12/01/16
SUBMITTAL NUMBER: TWO
REVIEW DATE: 12/02/16
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------IRON BRIDGE SPORTS PARK BASEBALL
SITE PLAN NUMBER----------17PR0141
ADDRESS-------------------11400 IRON BRIDGE ROAD
LATEST PLAN DATE----------09/20/16
DEPT. REC'D. DATE---------09/22/16
SUBMITTAL NUMBER----------ONE
REVIEW DATE---------------10/17/16
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------NO
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----NOT SUBMITTED
ARCHITECTURAL ELEVATIONS--NOT SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT SUBMITTED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A
COMPLETE RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE
PLANNING DEPARTMENT. BELOW EACH COMMENT DESCRIBE HOW YOU
HAVE ADDRESSED EACH REVIEW COMMENT. INDICATE WHICH SHEETS
SHOW THE REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF
REVIEW COMMENTS.
02. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER
17PR0141 IN THE LOWER RIGHT CORNER OF EACH SHEET.
03. CHANGE THE MAGESTERIAL DISTRICT TO DALE.
04. SHOW A PORTION OF ADJACENT BOUNDARY LINES PERPINDICULA
TO THE SUBJECT PARCEL BOUNDARY.
05. LIST THE PROPOSED BUILDING HEIGHT. A MAXIMUM OF 45 FEE
IS ALLOWED PER ORDINANCE IN THIS DESIGN DISTRICT.
06. IN THE PARKING CALCULATIONS LIST THE TOTAL REQUIRED AS
197 SPACES.
07. THE SLOPE ON HANDICAP PARKING SPACES IN ANY DIRECTION
SHALL NOT EXCEED 1:48 OR 2.0% (ADAAG 2004). THE
LONGITUDINAL SLOPE OF THE SPACES AT THE CENTER OF THE LOT
IS 5.0%.
08. PER SEC. 19.1-253 PARKING LOTS MUST BE DESIGNED TO
INCLUDE 30 SF OF INTERIOR PARKING LOT LANDSCAPING FOR EACH
PARKING SPACE. PROVIDE A CALCULATION FOR THE TOTAL NUMBER
OF PARKING SPACES (27) TIMES 30 S.F. TO DETERMINE TOTAL
LANDSCAPE AREA WITHIN PARKING LOT. LABEL EACH ISLAND WITH
THE SQUARE FOOTAGE TO INSURE THE MINIMUM REQUIREMENTS ARE
MET.
09. THE TOTAL NUMBER OF TREES IN A PARKING LOT SHALL BE 1
PER 200 S.F. OF REQUIRED LANDSCAPE AREA IN THE PARKING LOT
ROUNDED UP. SHOW THE CALCULATION FOR TOTAL NUMBER OF
TREES.
10. AT LEAST 50% OF THE TREES SHALL BE LARGE MATURING TREE
THAT ARE IN ISLANDS WITH A MINIMUM WIDTH OF 15 FEET AND 25
S.F. IN SIZE. SMALL MATURING TREES SHALL BE IN ISLANDS
WITH A MINIMUM WIDTH OF 9 FEET AND BE 150 S.F. IN SIZE.
19.1-253.C.5
11. PROVIDE A LANDSCAPE PLAN PER SECTION 19.1-246 OF THE
ZONING ORDINANCE.
12. PER SECTION 19.1-27(E), LANDSCAPE PLANS SHALL BE
CERTIFIED BY A STATE OF VIRGINIA REGISTERED LANDSCAPE
ARCHITECT, NURSERYMAN OR LANDSCAPE DESIGNER. THE COUNTY CA
NOT REVIEW THE LANDSCAPE PLAN UNTIL IT IS CERTIFIED PER
THIS REQUIREMENT.
13. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A READILY
AVAILABLE WATER SUPPLY. THE COUNTY ACCEPTS EITHER YARD
HYDRANTS AND/OR HOSE BIBS WITHIN 100 FEET OF ALL NEW
PLANTINGS OR AN IRRIGATION SYSTEM FOR ALL AREAS OF NEW
PLANTINGS. SHOW LOCATION OF HYDRANTS, BIBS OR IRRIGATION
SLEEVES. THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE WITH
WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE SPECIES.
INSURE WATER INFORMATION IS SUPPLIED ON UTILITY DEPARTMENT
METER SIZING FORMS. 19.1-249.B
14. INSTALLATION SURETY: PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, THE REQUIRED LANDSCAPING IS COMPLETED; O
A FORM OF SURETY SATISFACTORY TO THE DIRECTOR OF PLANNING
IS SUBMITTED IN AN AMOUNT EQUAL TO THE COST OF COMPLETING
THE REQUIRED LANDSCAPING. IF SURETY HAS BEEN SUBMITTED, TH
REQUIRED LANDSCAPING SHALL BE INSTALLED BASED UPON THE
APPROVED PHASING PLAN OR DURING THE FIRST PLANTING SEASON
FOLLOWING DATE OF ISSUANCE OF THE SURETY. 19.1-248.A.2
15. MAINTENANCE GUARANTEE: AFTER LANDSCAPING IS INSTALLED,
PRIOR TO RECEIVING AN OCCUPANCY PERMIT, THE APPLICANT SHAL
PROVIDE A LETTER OF GUARANTEE (COUNTY FORMAT) TO INSURE
REPLACEMENT OF UNHEALTHY, DYING, DEAD OR POLLARDED
LANDSCAPING WITHIN THE FIRST YEAR OF INSTALLATION.
19.1-248.B
16. SHOW ON THE LANDSCAPE PLAN OR ADDITIONALLY ON A
SEPARATE LIGHTING PLAN THE LOCATION OF ALL EXTERIOR SITE
LIGHTING MOUNTED ON POLES, THE BUILDING, OR ON THE GROUND
AND HAVE THEM KEYED TO CUT SHEETS FOR EACH LIGHT FIXTURE
SHOWN ON THE PLAN. 19.1-205
17. PROVIDE CATALOG CUTSHEETS FOR EACH EXTERIOR LIGHTING
FIXTURE PROPOSED. ALL SPECIFIED FIXTURES ARE TO BE FULL CU
OFF, DOWNWARD DIRECTIONAL, AND DIRECT LIGHT SOURCE SHIELDE
FROM VIEW.
18. PROVIDE 2 COPIES OF ELEVATIONS OF THE BUILDINGS WITH
ALL BUILDING MATERIALS AND COLORS IDENTIFIED, LOCATIONS OF
JUNCTION AND ACCESS BOXES SHOWN, AND HOW ALL MECHANICAL
EQUIPMENT IS SCREENED WHETHER IT IS MOUNTED ON THE ROOF OR
ON THE GROUND. 19.1-27.F
19. PER SEC. 19.1-317.C, SHOW THAT JUNCTION AND ACCESS
BOXES ARE EITHER SCREENED OR PAINTED TO MATCH THE BUILDING
EXCEPT AS ALLOWED IN I-2 AND I-3 DISTRICTS.
20. PER SEC. 19.1-317.D, MECHANICAL EQUIPMENT, WHETHER
ROOF-TOP OR GROUND LEVEL, SHALL BE SHIELDED AND SCREENED
FROM PUBLIC VIEW AND DESIGNED TO BE PERCEIVED AS AN
INTEGRAL PART OF THE BUILDING EXCEPT AS ALLOWED IN I-2 AND
I-3 DISTRICTS. SHOW ALL UNITS IN RELIEF BEHIND PARAPETS
AND/OR WALLS USED FOR SCREENING TO SHOW THAT UNITS ARE
FULLY SCREENED. 19.1-317.D
21. SHOW THE LOCATION OF THE ROOF ACCESS. EXTERIOR LADDER
ACCESS AND PARAPET OPENINGS SHALL NOT BE VISIBLE FROM
ADJACENT PROPERTIES AND PUBLIC RIGHTS OF WAY, AND ANY
EXTERIOR ACCESS MUST BE DESIGNED IN A MANNER INTEGRAL TO
THE ARCHITECTURAL CHARACTER OF THE BUILDING. PROVIDE
INTERIOR ACCESS THROUGH YOUR SPACE, OR A COMMON CONTROL
ROOM.
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------IRON BRIDGE SPORTS PARK BASEBALL
SITE PLAN NUMBER----------17PR0141
ADDRESS-------------------11400 IRON BRIDGE ROAD
LATEST PLAN DATE----------11/23/16
DEPT. REC'D. DATE---------11/23/16
SUBMITTAL NUMBER----------2
REVIEW DATE---------------12/19/16
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------YES
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----SUBMITTED
ARCHITECTURAL ELEVATIONS--SUBMITTED
LIGHTING PLAN/CUTSHEETS---SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT SUBMITTED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A
COMPLETE RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE
PLANNING DEPARTMENT. BELOW EACH COMMENT DESCRIBE HOW YOU
HAVE ADDRESSED EACH REVIEW COMMENT. INDICATE WHICH SHEETS
SHOW THE REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF
REVIEW COMMENTS.
02. PUT THE CORRECT CHESTERFIELD COUNTY SITE PLAN NUMBER
17PR0141 IN THE LOWER RIGHT CORNER OF SHEET L2.
03. RED MAPLES ARE NOT RECOMMENDED FOR INTERIOR PARKING LO
ISLANDS DUE TO LOW HEAT TOLERANCE. FOR THE TWO INTERIOR
ISLANDS AT THE ENTRANCE TO THE PARKING LOT SELECT A
DIFFERENT LARGE DECIDUOUS TREE SPECIES. THE COUNTY APPROVE
PLANT MATERIAL LIST CAN BE PROVIDED UPON REQUEST.
04. THE MINIMUM WIDTH OF A LARGE DECIDUOUS TREE PLANTING
ARE IS 15 FEET. THE TWO ISLANDS AT THE ENTRANCE TO THE
PARKING LOT DO NOT MEET THIS. EXPAND THE ISLANDS TO
ACCOMMODATE LARGE TREES. 19.1-253.B
05. THE INTERIOR PARKING LOT LANDSCAPE AREA CANNOT EXTEND
BEYOND THE OUTER BOUNDARIES OF THE PARKING LOT, AS SHOWN
WITH THE BEDS ON THE ENDS. GROUNDCOVER BEDS MAY EXTEND
BEYOND, BUT INTERIOR AREA SHOULD BE DEMARCATED IN-LINE WIT
THE CURB LINE. REVISE THE INTERIOR PARKING LOT LANDSCAPE
AREAS AND CALCULATIONS.
06. SELECT A WATERING OPTION. IF AN IRRIGATION SYSTEM IS
USED, SHOW THE LIMITS OF IRRIGATION AND SLEEVES UNDER
PAVING. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A
READILY AVAILABLE WATER SUPPLY. THE COUNTY ACCEPTS EITHER
YARD HYDRANTS AND/OR HOSE BIBS WITHIN 100 FEET OF ALL NEW
PLANTINGS OR AN IRRIGATION SYSTEM FOR ALL AREAS OF NEW
PLANTINGS. SHOW LOCATION OF HYDRANTS, BIBS OR IRRIGATION
SLEEVES. THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE WITH
WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE SPECIES.
07. INSTALLATION SURETY: PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, THE REQUIRED LANDSCAPING IS COMPLETED; O
A FORM OF SURETY SATISFACTORY TO THE DIRECTOR OF PLANNING
IS SUBMITTED IN AN AMOUNT EQUAL TO THE COST OF COMPLETING
THE REQUIRED LANDSCAPING. IF SURETY HAS BEEN SUBMITTED, TH
REQUIRED LANDSCAPING SHALL BE INSTALLED BASED UPON THE
APPROVED PHASING PLAN OR DURING THE FIRST PLANTING SEASON
FOLLOWING DATE OF ISSUANCE OF THE SURETY. 19.1-248.A.2
08. MAINTENANCE GUARANTEE: AFTER LANDSCAPING IS INSTALLED,
PRIOR TO RECEIVING AN OCCUPANCY PERMIT, THE APPLICANT SHAL
PROVIDE A LETTER OF GUARANTEE (COUNTY FORMAT) TO INSURE
REPLACEMENT OF UNHEALTHY, DYING, DEAD OR POLLARDED
LANDSCAPING WITHIN THE FIRST YEAR OF INSTALLATION.
19.1-248.B
09. SHOW SITE LIGHTING FIXTURE LOCATIONS ON THE LANDSCAPE
PLAN. AS DRAWN ON THE LIGHTING PLAN, CONFLICTS EXIST
BETWEEN LIGHT POLES AND SMALL DECIDUOUS TREES(ENSURE
MINIMUM 5 FOOT SEPARATION), THE SANITARY LINE, AND
SIDEWALK.
10. THE ARCHITECT HAS COORDINATED WITH PLANNING ON REVISED
ARCHITECTURAL ELEVATIONS. PROVIDE 2 COPIES OF UPDATED COLO
RENDERED ELEVATIONS AS DISCUSSED AT A MINIMUM SIZE OF
11X17.
11. PER SEC. 19.1-317.C, SHOW THAT JUNCTION AND ACCESS
BOXES ARE EITHER SCREENED OR PAINTED TO MATCH THE BUILDING
EXCEPT AS ALLOWED IN I-2 AND I-3 DISTRICTS.
12. PER SEC. 19.1-317.D, MECHANICAL EQUIPMENT, WHETHER
ROOF-TOP OR GROUND LEVEL, SHALL BE SHIELDED AND SCREENED
FROM PUBLIC VIEW AND DESIGNED TO BE PERCEIVED AS AN
INTEGRAL PART OF THE BUILDING EXCEPT AS ALLOWED IN I-2 AND
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------IRON BRIDGE SPORTS PARK BASEBALL
SITE PLAN NUMBER----------17PR0141
ADDRESS-------------------11400 IRON BRIDGE ROAD
LATEST PLAN DATE----------04/26/17
DEPT. REC'D. DATE---------04/26/17
SUBMITTAL NUMBER----------4 (ADJUSTMENT TO APPROVED)
REVIEW DATE---------------04/26/17 (TR)
RECOMMENDATION------------APPROVED
TABLE REVIEW--------------N/A
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----NOT PROVIDED
ARCHITECTURAL ELEVATIONS--APPROVED
LIGHTING PLAN/CUTSHEETS---NOT PROVIDED
IRRIGATION/HOSEBIB PLAN---NOT PROVIDED
01. AT THE TIME OF BUILDING PERMIT REVIEW, A LANDSCAPE PLA
PREPARED BY A LICENSED LANDSCAPE ARCHITECT OR CERTIFIED
LANDSCAPE DESIGNER FOR PLANTINGS ALONG THE NEW BUILDING
FOUNDATION (WEST, NORTH, AND EAST ELEVATIONS) SHALL BE
SUBMITTED TO PLANNING FOR REVIEW. THE PLAN SHALL FOLLOW
RECOMMENDATIONS PROVIDED BY PLANNING DURING REVIEW OF THIS
SITE PLAN ADJUSTMENT. INSPECTION AND APPROVAL BY PLANNING
OF THE INSTALLED LANDSCAPING AT THE TIME OF OCCUPANCY
PERMIT WILL BE REQUIRED.
02. SELECT A WATERING OPTION. IF AN IRRIGATION SYSTEM IS
USED, SHOW THE LIMITS OF IRRIGATION AND SLEEVES UNDER
PAVING. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A
READILY AVAILABLE WATER SUPPLY. THE COUNTY ACCEPTS EITHER
YARD HYDRANTS AND/OR HOSE BIBS WITHIN 100 FEET OF ALL NEW
PLANTINGS OR AN IRRIGATION SYSTEM FOR ALL AREAS OF NEW
PLANTINGS. SHOW LOCATION OF HYDRANTS, BIBS OR IRRIGATION
SLEEVES. THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE WITH
WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE SPECIES.
INSURE WATER INFORMATION IS SUPPLIED ON UTILITY DEPARTMENT
METER SIZING FORMS.
03. MAINTENANCE GUARANTEE: AFTER LANDSCAPING IS INSTALLED,
PRIOR TO RECEIVING AN OCCUPANCY PERMIT, THE APPLICANT SHAL
PROVIDE A LETTER OF GUARANTEE (COUNTY FORMAT) TO INSURE
REPLACEMENT OF UNHEALTHY, DYING, DEAD OR POLLARDED
LANDSCAPING WITHIN THE FIRST YEAR OF INSTALLATION.
04. REQUIRED LANDSCAPING WHICH IS REMOVED, BECOMES
UNHEALTHY OR DIES, OR IS POLLARDED SHALL BE REPLACED
DURING THE NEXT PLANTING SEASON.
**********************************************************
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : IRONBRIDGE SPORTS PARK
CASE NUMBER : 17PR0141
LATEST PLAN DATE : 9/20/16
RECEIVED DATE : 9/30/16
SUBMITTAL NUMBER : 1
REVIEW DATE : 10/14/16
ADDRESS : 11400 IRON BRIDGE RD
STATUS : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM 1983
ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE PARCEL
BOUNDARY.
2. PLEASE PROVIDE THE INFO FOR THE MISSING BEARING AND
DISTANCE BETWEEN N35-50-46W 10.49' AND N63-26-19W 113.58'
3. PLEASE PROVIDE THE BEARINGS AND DISTANCES FOR THE
EXISTING R/W AND MORE LEGIBLE TEXT FOR THE PROPOSED R/W.
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : IRONBRIDGE SPORTS PARK
CASE NUMBER : 17PR0141
LATEST PLAN DATE : 11/23/16
RECEIVED DATE : 12/5/16
SUBMITTAL NUMBER : 2
REVIEW DATE : 12/16/16
ADDRESS : 11400 IRON BRIDGE RD
STATUS : APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: IRONBRIDGE SPORTS PARK
SITE PLAN NUMBER: 17PR0141
ADDRESS: 11400 IRON BRIDGE ROAD
LATEST PLAN DATE: 9/20/16
DEPT. REC'D. DATE: 9/29/16
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 10/4/16
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. THE FIRE LANE ON THE EAST SIDE OF THE BUILDING SHALL
BE 20 FEET WIDE THE ENTIRE LENGTH OF THE BUILDING.
2. ADD THE NOTE TO THE GENERAL NOTES SECTION OF THE PLAN
AND TO THE LANDSCAPING PLANS.
"NO LANDSCAPING OF ANY TYPE SHALL BE PLACED WITHIN A
THREE FOOT RADIUS OF ANY FIRE HYDRANT, FIRE PUMP TEST
HEADER, FIRE DEPARTMENT SPRINKLER SYSTEM CONNECTION,
FIRE DEPARTMENT STANDPIPE CONNECTION OR FIRE SUPPRESSION
CONTROL VALVE. LANDSCAPING IN THE AREA OF FIRE HYDRANTS,
FIRE PUMP TEST HEADERS, FIRE DEPARTMENT SPRINKLER
SYSTEM CONNECTIONS OR FIRE DEPARTMENT STANDPIPE
CONNECTIONS SHALL BE OF THE TYPE THAT WILL NOT ENCROACH
ON THE REQUIRED THREE FOOT CLEAR RADIUS ON MATURITY OF
THE LANDSCAPING"
3. THE MINIMUM REQUIRED FIRE FLOW FOR PROTECTION PURPOSES
SHALL BE SHOWN ON THE SUBMITTED DRAWINGS. REFER TO THE
INTERNATIONAL FIRE CODE (2012), SECTION B105 AND THE
COUNTY CODE OF CHESTERFIELD FOR EXCEPTIONS ALLOWED FOR
SPRINKLER PROTECTED BUILDINGS
REFER TO THE INTERNATIONAL FIRE CODE (2012) -
SECTION B104, B104.1, B104.2 AND B104.3 FOR THE CALCULATIO
PROCESS AND ALLOWANCES. THE CORRECT FORMAT AND CALCULATION
SHEET CAN BE OBTAINED VIA THE INTERNET AT
CHESTERFIELD COUNTY- CHESTERFIELD FIRE AND EMS - DIVISION
OF FIRE AND LIFE SAFETY
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
4. PROVIDE COMPUTER GENERATED WATER FLOW TEST DATA,
PROVIDED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT, VERIFYING THE REQUIRED WATER FLOW FOR FIRE
PROTECTION IS AVAILABLE AT THE SITE. THE WATERFLOW TEST
RESULTS AND GRAPH SHALL BE SHOWN ON THE SUBMITTED PLAN.
THE MINIMUM REQUIRED FIRE FLOW FOR ALL BUILDINGS, WITH
THE EXCEPTION OF ONE AND TWO-FAMILY DWELLINGS, IS 1500
GPM (SPRINKLER PROTECTED OR NON-SPRINKLER PROTECTED) IN
ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (2012) -
SECTION B105.2 AND TABLE B105.1.
5. SHOW THE NODE MAP AND RESULTS TABLE FOR THE PROPOSED
OR EXISTING HYDRANTS ON SITE SHOWING THE MAXIMUM FIRE
FLOW CAN BE ACHIEVED. WHEN MULTIPLE FIRE HYDRANTS ARE
USED THE COMBINED FLOW MUST BE SIMULTANEOUS.
6. THE APPROXIMATE LOCATION OF ALL REQUIRED FIRE LANE
SIGNS AND CURB / STREET MARKING SHALL BE INDICATED ON
THE PLAN. FIRE LANES THAT ARE BETWEEN TWENTY AND
TWENTY-SIX FEET IN WIDTH SHALL BE POSTED AND MARKED ON
BOTH SIDES OF THE ROADWAY. FIRE LANES IN EXCESS OF
TWENTY-SIX FEET IN WIDTH UP TO THIRTY-TWO FEET IN WIDTH
SHALL BE POSTED AND MARKED ON ONE SIDE OF THE
ROADWAY. THE LOCATION OF AND METHOD OF MARKING FIRE
LANES SHALL BE CLEARLY INDICATED ON THE SUBMITTED SITE
PLAN. ALL FIRE LANE SIGNS SHALL BE DOUBLE FACED AND
INSTALLED PERPENDICULAR TO THE CURB.
7. PROVIDE THE CHESTERFIELD COUNTY STANDARD FIRE LANE
DETAIL ON THE PLAN.
8. A LETTER REQUESTING RELIEF FROM A SECOND ACCESS NEEDS T
BE SUBMITTED WITH SPECIFICS ON LIMITATIONS OF ROOF LOADS,
INTERIOR SEATING, INTERIOR STORAGE OF COMBUSTIBLES, AND
THE USE OF NON-COMBUSTIBLE EXTERIOR FINISHES.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: IRONBRIDGE SPORTS PARK
SITE PLAN NUMBER: 17PR0141
ADDRESS: 11400 IRON BRIDGE ROAD
LATEST PLAN DATE: 11/23/16
DEPT. REC'D. DATE: 12/5/16
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 12/8/16
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. PROVIDE COMPUTER GENERATED WATER FLOW TEST DATA,
PROVIDED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT, VERIFYING THE REQUIRED WATER FLOW FOR FIRE
PROTECTION IS AVAILABLE AT THE SITE. THE WATERFLOW TEST
RESULTS AND GRAPH SHALL BE SHOWN ON THE SUBMITTED PLAN.
THE MINIMUM REQUIRED FIRE FLOW FOR ALL BUILDINGS, WITH
THE EXCEPTION OF ONE AND TWO-FAMILY DWELLINGS, IS 1500
GPM (SPRINKLER PROTECTED OR NON-SPRINKLER PROTECTED) IN
ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (2012) -
SECTION B105.2 AND TABLE B105.1.
2.. SHOW THE NODE MAP AND RESULTS TABLE FOR THE PROPOSED
OR EXISTING HYDRANTS ON SITE SHOWING THE MAXIMUM FIRE
FLOW CAN BE ACHIEVED. WHEN MULTIPLE FIRE HYDRANTS ARE
USED THE COMBINED FLOW MUST BE SIMULTANEOUS.
3. COPY THE CODE MODIFICATION REQUEST LETTER AND THE
CODE MODIFICATION APPROVAL LETTER TO THE SITE PLAN.
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : DUSTIN DUNNAGAN / 706-2061
NAME OF PLAN : IRONBRIDGE SPORTS PARK 2016
IMPROVEMENTS
ADDRESS : 11400 IRON BRIDGE ROAD
SITE PLAN NO. : 17PR0141
LATEST PLAN DATE : SEPTEMBER 20, 2016
DEPT. REC'D DATE : SEPTEMBER 29, 2016
SUBMITTAL NUMBER : 1
REVIEW DATE : OCTOBER 14, 2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY. WETLANDS DOCUMENTATION MUST BE
RECEIVED BY THIS DEPARTMENT PRIOR TO ISSUANCE OF THE
LAND DISTURBANCE PERMIT.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. EFFECTIVE JULY 1, 2014, ENFORCEMENT OF THE VIRGINIA
STORMWATER REGULATIONS BECAME THE RESPONSIBILITY OF
THE COUNTY FOR DEVELOPMENT PROJECTS WITHIN
CHESTERFIELD COUNTY. ADDITIONALLY, NEW STATE
STORMWATER REGULATIONS ALSO BECAME EFFECTIVE ON
JULY 1, 2014. LAND DISTURBING ACTIVITIES THAT
OBTAINED A VSMP PERMIT PRIOR TO JULY 1, 2014 MAY
USE THE STORMWATER MANAGEMENT CRITERIA SPECIFIED
IN PART II C (9VAC25-870-93 ET SEQ) FOR TWO PERMIT
CYCLES. PROJECTS GRANDFATHERED UNDER THE PROVISIONS
OF 9VAC25-870-48 MAY FOLLOW THE REQUIREMENTS LISTED
UNDER PART IIC FOR ONE PERMIT CYCLE. ALL OTHER NEW
DEVELOPMENT WILL BE SUBJECT TO THE REQUIREMENTS OF
PART IIB (9VAC25-870-62 TO 9VAC25-870-92).
03. PROVIDE THE FOLLOWING INFORMATION ON THE COVER SHEET:
A. LATITUDE AND LONGITUDE FOR THE PROJECT SITE (IN
DEGREES, MINUTES, SECONDS, TO THE NEAREST 15 SECONDS)
B. NAME OF RECEIVING CHANNEL/WATERS
C. VAHU6 FOUR DIGIT WATERSHED CODE
D. TOTAL ON-SITE IMPERVIOUS COVER IN SQUARE FEET (NOT
INCLUDING VDOT RIGHTS-OF-WAY).
04. ALL ROOF WATER AND DOWNDRAINS MUST BE COLLECTED AND
DISCHARGED IN A NON-ERODIBLE MANNER. (CL-G&D 6)
05. A DETAILED SEQUENCE OF CONSTRUCTION IS REQUIRED WHICH
COORDINATES THE INSTALLATION AND REMOVAL OF THE
EROSION AND SEDIMENT CONTROL MEASURES WITH CONSTRUCTIO
OF THE REMAINDER OF THE PROJECT. (CL-EC 3)
06. A NOTE MUST BE ADDED TO THE CONSTRUCTION SEQUENCE WHIC
REQUIRES THE OWNER TO GIVE THE COUNTY INSPECTOR 48
HOURS NOTIFICATION TO SCHEDULE AN ON-SITE PRE-
CONSTRUCTION MEETING FOR THE ISSUANCE OF A LAND
DISTURBANCE PERMIT. THIS NOTE SHOULD BE THE FIRST STE
IN THE EROSION CONTROL NARRATIVE/SEQUENCE OF
CONSTRUCTION. (CL-EC 4)
07. A NOTE MUST BE ADDED TO THE SEQUENCE OF CONSTRUCTION
STATING THAT THE CERTIFIED RESPONSIBLE LAND DISTURBER
(CRLD) MUST ATTEND THE PRE-CONSTRUCTION MEETING.
(CL-EC 5)
08. STEPS MUST BE INCLUDED IN THE SEQUENCE OF CONSTRUCTION
EVENTS FOR INSTALLATION OF STORM SEWER, DROP INLETS,
INLET PROTECTION, CURB & GUTTER, AND BUILDING
CONSTRUCTION. (CL-EC 6)
09. THE SEQUENCE OF CONSTRUCTION AND EROSION CONTROL LEGEN
MUST BE SHOWN ON THE EROSION CONTROL PLAN SHEET(S).
(CL-EC 8)
10. A DETAIL MUST BE SHOWN WHICH PROVIDES FOR PLACEMENT OF
EXCAVATED TRENCH MATERIAL ON THE UPHILL SIDE OF THE
TRENCH WHILE SILT FENCE AND STOCKPILED MATERIALS ARE
PLACED ON THE DOWNSTREAM SIDE. (CL-EC 37)
11. ANY SOIL STOCKPILE AREA MUST BE LOCATED ON THE PLANS.
SILT FENCE MUST BE PROVIDED AROUND THE PERIMETER.
(CL-EC 39)
12. THE FOLLOWING NOTE(S) MUST BE ADDED TO OR ADJACENT TO
THE SEQUENCE OF CONSTRUCTION: (CL-EC 42)
A. AT THE TIME OF THE PRE-CONSTRUCTION MEETING, TWO
STANDARD SIGNS MUST BE INSTALLED ON EACH SIDE OF THE
CONSTRUCTION ACCESS. THESE SIGNS SHOULD STATE EITHER
"CONSTRUCTION ENTRANCE AHEAD" OR "TRUCKS ENTERING
HIGHWAY". (CL-EC 42E)
13. CREDITS FOR THE PART IIC COMPLIANCE MUST BE PURCHASED
FROM THE HOA FOR IRONBRIDGE LAKE PRIOR TO ISSUANCE OF
LAND DISTURBANCE PERMIT.
14. ON THE COVER PAGE, IN THE CBPA NOTE, INDICATE THE
TECHNICAL CRITERIA OF THE PROJECT AND ITS
GRANDFATHERING STATUS.
15. ON SHEET C-2 AND ALL OTHER APPLICABLE SHEETS, THE
EXISTING CONTOURS AND INFRASTRUCTURE ARE DIFFICULT TO
SEE AND BE PICKED UP WITH THE COUNTY SCANNERS. DARKEN
THE EXISTING INFORMATION.
16. SHEET C-3:
A) REMOVE SUPER SILT FENCE FROM PAVED AREAS.
B) ON ALL APPLICABLE SHEETS, SHOW THE WETLANDS AND ITS
LIMITS.
C) CLARIFY HOW NON-CONSTRUCTION TRAFFIC IS TO CIRCULAT
THE SITE DURING CONSTRUCTION.
D) PROVIDE NOTES FOR THE DEMOLITION OF ASPHALT BENEATH
THE CONSTRUCTION ENTRANCE PRIOR TO THE INSTALLATION
OF THE CONSTRUCTION ENTRANCE.
E) PROVIDE SAFETY FENCE AROUND THE NORTH SIDE OF THE
PROJECT TO PROHIBIT PEDESTRIAN MOVEMENT INTO THE
CONSTRUCTION AREA.
F) REMOVE SUPER SILT FENCE FROM THE CONVEYANCE CHANNEL
FOR THE EXISTING CURB CUTS.
17. SHEET C-4:
A) PROVIDE DIFFERENTIATION BETWEEN THE EXISTING AND
PROPOSED CONTOURS.
B) PROVIDE INLET PROTECTION FOR PROPOSED CURB CUTS.
C) PROVIDE EROSION CONTROL FOR THE PROPOSED CHANNELS.
D) PROVIDE AT LEAST A 2' LONG PAVED FLUME FROM THE CUR
CUT TO THE RIP-RAP LINED CHANNEL.
18. ON SHEET C-6, PROVIDE CURBING FOR THE STUB-OUT TO THE
EAST.
19. SHEET C-7:
A) PROVIDE CALCULATIONS FOR THE PROPOSED CHANNELS
CONVEYING THE DISCHARGE FROM THE CURB CUTS.
B) PROVIDE MS-19 CALCULATIONS FOR THE EXISTING CHANNEL
RECEIVING SITE RUNOFF.
C) PROVIDE GRADES FOR THE CURBING TO THE EAST NEAR THE
STUB-OUT.
D) CLARIFY IF THE SHED TO THE SOUTHWEST IS PROPOSED.
E) PROVIDE TIE-IN ELEVATIONS FOR THE EXISTING CURB.
F) PROVIDE A STRAIGHTER TIE-IN FOR THE CURB CUT TO THE
NORTH TO THE RECEIVING CHANNEL. AS SHOWN IT IS AN
ACUTE ANGLE THAT COULD LEAD TO INCREASED EROSION.
20. SHEET C-8:
A) PROVIDE A 25-YEAR CHECK STORM FOR THE CULVERT IN
ACCORDANCE WITH VDOT POLICY.
B) THE DRAINAGE AREA IN THE CULVERT CALCULATION DOES
NOT MATCH THE DRAINAGE AREA SHOWN IN PLAN VIEW.
C) THE CALCULATIONS ARE PIXELATED AND DIFFICULT TO
READ. PROVIDE CLEARER CALCULATIONS.
D) CLARIFY IF THE 100-YEAR STORM IS USING A 1.25
SATURATION FACTOR.
E) LABEL CONTOURS.
F) THE DRAINAGE AREA SHOWN DOES NOT MATCH PREVIOUSLY
APPROVED PLANS. CLARIFY DISCREPANCIES.
G) PROVIDE C-VALUES FOR THE DRAINAGE AREAS.
H) THE DRAINAGE AREAS APPEAR TO CLIP CONTOURS.
I) SHOW MORE OF THE OFFSITE AREA INCLUDING BUILDINGS
AND OTHER INFRASTRUCTURE.
21. ON SHEET C-10, NOTE THE APPROVED IMPERVIOUS AMOUNT FRO
THE CBPA PLAN.
22. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
23. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
24. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
25. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. THE VIRGINIA STORMWATER MANAGEMENT PERMIT (VSMP)
REGISTRATION STATEMENT AND FEE OF $209
E. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : DUSTIN DUNNAGAN / 706-2061
NAME OF PLAN : IRONBRIDGE SPORTS PARK 2016
IMPROVEMENTS
ADDRESS : 11400 IRON BRIDGE ROAD
SITE PLAN NO. : 17PR0141
LATEST PLAN DATE : NOVEMBER 23, 2016
DEPT. REC'D DATE : NOVEMBER 30, 2016
SUBMITTAL NUMBER : 2
REVIEW DATE : NOVEMBER 15, 2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY. WETLANDS DOCUMENTATION MUST BE
RECEIVED BY THIS DEPARTMENT PRIOR TO ISSUANCE OF THE
LAND DISTURBANCE PERMIT.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. EFFECTIVE JULY 1, 2014, ENFORCEMENT OF THE VIRGINIA
STORMWATER REGULATIONS BECAME THE RESPONSIBILITY OF
THE COUNTY FOR DEVELOPMENT PROJECTS WITHIN
CHESTERFIELD COUNTY. ADDITIONALLY, NEW STATE
STORMWATER REGULATIONS ALSO BECAME EFFECTIVE ON
JULY 1, 2014. LAND DISTURBING ACTIVITIES THAT
OBTAINED A VSMP PERMIT PRIOR TO JULY 1, 2014 MAY
USE THE STORMWATER MANAGEMENT CRITERIA SPECIFIED
IN PART II C (9VAC25-870-93 ET SEQ) FOR TWO PERMIT
CYCLES. PROJECTS GRANDFATHERED UNDER THE PROVISIONS
OF 9VAC25-870-48 MAY FOLLOW THE REQUIREMENTS LISTED
UNDER PART IIC FOR ONE PERMIT CYCLE. ALL OTHER NEW
DEVELOPMENT WILL BE SUBJECT TO THE REQUIREMENTS OF
PART IIB (9VAC25-870-62 TO 9VAC25-870-92).
03. A DETAIL MUST BE SHOWN WHICH PROVIDES FOR PLACEMENT OF
EXCAVATED TRENCH MATERIAL ON THE UPHILL SIDE OF THE
TRENCH WHILE SILT FENCE AND STOCKPILED MATERIALS ARE
PLACED ON THE DOWNSTREAM SIDE. (CL-EC 37)
04. CREDITS FOR THE PART IIC COMPLIANCE MUST BE PURCHASED
FROM THE HOA FOR IRONBRIDGE LAKE PRIOR TO ISSUANCE OF
LAND DISTURBANCE PERMIT.
05. SHEET C-3:
A) ON ALL APPLICABLE SHEETS, SHOW THE WETLANDS AND ITS
LIMITS.
B) INCLUDE SILT FENCE OUTLETS IN THE CONSTRUCTION
NARRATIVE.
C) THE WETLANDS PERMIT PROVIDED APPEARS TO HAVE
EXPIRED. IN ADDITION, IT APPEARS SOME OF THE
PERMITTED IMPACTS WERE NOT CONSTRUCTED. ENSURE ANY
WETLAND IMPACTS ARE COVERED UNDER A PERMIT.
D) PROVIDE TEMPORARY SEEDING FOR THE SOIL STOCKPILE.
E) ADJUST THE SUPER SILT FENCE TO THE NORTHEAST TO BE
OUTSIDE OF THE WETLAND CHANNEL AND MORE ONTO THE
BANKS.
06. SHEET C-4:
A) ADJUST THE SUPER SILT FENCE TO THE NORTHEAST TO BE
OUT OF THE FLOW LINE FOR THE PROPOSED CHANNEL.
IT IS SUGGESTED TO PUT A SILT FENCE OUTLET IN THIS
LOCATION.
07. SHEET C-8:
A) ENSURE THE 25-YEAR FLOW CALCULATION FOR THE CULVERT
INCLUDES THE 1.1 SATURATION FACTOR.
B) SHOW MORE OF THE OFFSITE AREA TO THE NORTH AND SOUT
OF THE PROJECT SITE INCLUDING BUILDINGS AND OTHER
INFRASTRUCTURE.
C) PROVIDE A NORTH ARROW.
D) PROVIDE A NOTE FOR THE MS-19 TABLE THAT 10-10
DETENTION IS MET THROUGH IRONBRIDGE LAKE CBPA PLAN.
08. ON SHEET C-10, FOR THE SITE AREA SHOW ONLY THE SITE
AREA/LIMITS OF DISTURBANCE, INSTEAD OF THE WHOLE
PARCEL.
09. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
10. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
11. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
12. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. THE VIRGINIA STORMWATER MANAGEMENT PERMIT (VSMP)
REGISTRATION STATEMENT AND FEE OF $209
E. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================

Modify comments view for case # 17PR0141



Go to Case Selection Form or Go to Project List