CASE NO: 17PR0104 STATUS: APPROVED - ADMIN
PROJECT NAME: PBH TURN LANE - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 07/07/16 07/28/16 ******** ********
ENVIR.ENGR.-: 01 10/18/16 11/08/16 COMPLETE 11/15/16 CBH 776-7836
FIRE DEPT.--: 01 10/18/16 11/08/16 COMPLETE 11/03/16 AWB 717-6167
HOUSE NUMBER: 01 10/18/16 11/08/16 ******** 07/15/16 AMJ 768-7549
MAPPING/GIS-: 01 10/18/16 11/08/16 COMPLETE 11/04/16 AMJ 768-7549
POLICE DEPT.: 01 10/18/16 11/08/16 ******** ********
PLANNING----: 01 10/18/16 11/08/16 COMPLETE 11/02/16 CH 717-6042
TRANSPORT.--: 01 10/18/16 11/08/16 COMPLETE 10/21/16 SJA 751-4461
UTIL.PLAN.--: 01 10/18/16 11/08/16 ******** ********
UTILITIES---: 01 10/18/16 11/08/16 COMPLETE 10/21/16 M L 748-1338
UTIL.R.O.W.-: 01 10/18/16 11/08/16 ******** ********
VDOT--------: 01 10/18/16 11/08/16 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E. / 804-748-1338
NAME OF PLAN : PBH TURN LANE
ADDRESS : 12131 MIDLOTHIAN TURNPIKE
SUBMISSION DATE : 07/07/16
PLAN DATED : 06/28/16
REVIEW DATE : 07/18/16
SITE PLAN NO. : 17PR0104
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. UTILITIES PROJECT NUMBER 16-0189 SHALL BE PLACED ON
THE LOWER RIGHT HAND CORNER OF EACH SHEET.
2. PLEASE PUT UTILITIES CONTACT MIKE LARSON, P.E. 748-
1338, LARSONM@CHESTERFIELD.GOV ON THE COVER SHEET.
3. THERE IS AN ABANDONED 16-INCH AC WATER MAIN, COUNTY
PROJECT C-454 THAT SHOULD BE LABELED ON THE PLANS.
4. PLEASE LABEL ALL EXISTING EASEMENTS WITH THE DB AND
PAGE NUMBER. IT APPEARS THAT SOME OF THE NEWER FROM THE
2002 36" WATERLINE PROJECT ARE NOT SHOWN.
MAIN, COUNTY PROJECT NUMBER 01-0202 ON ALL APPLICABLE
SHEETS.
5. FROM OUR REVIEW OF THE AS-BUILT DRAWINGS FOR THE 36-
INCH WATER MAIN, IT APPEARS THAT THE WATER MAIN ABOVE THE
45 DEGREE BEND NEAR STA 62+75 ONLY HAS ABOUT 4 FT OF COVER
THE GRADING PLAN SHOWS A 2 FT CUT ABOVE THE PIPE IN THIS
AREA, WHICH IS NOT ACCEPTABLE. THE WATER MAIN SHOULD BE
FIELD LOCATED BY POTHOLING PRIOR TO COMPLETION OF DESIGN
AND IF 3.5 FEET OF COVER CANNOT BE MAINTAINED THEN THE
GRADING PLAN WILL NEED TO BE REVISED. IT WILL NOT BE
ACCEPTABLE TO THE UTILITIES DEPARTMENT TO PROVIDE A NOTE
FOR THE CONTRACTOR TO VERIFY DEPTH DURING CONSTRUCTION.
6. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS). ONE ADDITIONAL ROLLED SET WILL BE REQUESTED AFTER
THE PROJECT IS RELEASED TO CONSTRUCTION TO BE USED FOR AS-
BUILTS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E. / 804-748-1338
NAME OF PLAN : PBH TURN LANE
ADDRESS : 12131 MIDLOTHIAN TURNPIKE
SUBMISSION DATE : 10/18/16
PLAN DATED : 10/18/16
REVIEW DATE : 10/21/16
SITE PLAN NO. : 17PR0104
COMMENTS : 2ND REVIEW- APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: PBH TURN LANE
SITE PLAN NUMBER: 17PR0104
LATEST PLAN DATE: 06/28/16
DEPT. REC'D. DATE: 07/11/16
SUBMITTAL NUMBER: ONE
REVIEW DATE: 07/19/16
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: PRIVATE ACCESS EASEMENT
1. PRIOR TO ANY SITE PLAN APPROVAL, REDCORD A PRIVATE NON-
EXCLUSIVE ACCESS EASEMENT FROM THE PROPOSED ROUTE 60 ACCES
TO THE ADJACENT PROPERTIES TO THE EAST (TAX ID'S 738-708-
0700 AND 737-708-9017, OWNED BY PBH LLC).
PRIVATE ACCESS EASEMENT WAS PREVIOUSLY COMMITTED TO BY THE
OWNER DURING THE ROUTE 60 WIDENING PROJECT AND HAS YET TO
BE ADDRESSED.
2. LABEL THE COUNTY'S CLASSIFICATION FOR ROUTE 60 (MAJOR
ARTERIAL) ON THE PLANS.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: PBH TURN LANE
SITE PLAN NUMBER: 17PR0104
LATEST PLAN DATE: 10/18/16
DEPT. REC'D. DATE: 10/20/16
SUBMITTAL NUMBER: TWO
REVIEW DATE: 10/21/16
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: PRIVATE ACCESS EASEMENT
PRIOR TO ANY SITE PLAN APPROVAL, REDCORD A PRIVATE NON-
EXCLUSIVE ACCESS EASEMENT FROM THE PROPOSED ROUTE 60 ACCES
TO THE ADJACENT PROPERTIES TO THE EAST (TAX ID'S 738-708-
0700 AND 737-708-9017, OWNED BY PBH LLC).
PRIVATE ACCESS EASEMENT WAS PREVIOUSLY COMMITTED TO BY THE
OWNER DURING THE ROUTE 60 WIDENING PROJECT AND HAS YET TO
BE ADDRESSED.
==========================================================
==========================================================
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------PBH TURN LANE
SITE PLAN NUMBER----------17PR0104
ADDRESS-------------------12131, 12015, 12001, 12009 MIDLO
LATEST PLAN DATE----------06/28/16
DEPT. REC'D. DATE---------06/28/16
SUBMITTAL NUMBER----------ONE
REVIEW DATE---------------07/25/16
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------YES
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----NOT REQUIRED
ARCHITECTURAL ELEVATIONS--NOT REQUIRED
LIGHTING PLAN/CUTSHEETS---NOT REQUIRED
IRRIGATION/HOSEBIB PLAN---NOT REQUIRED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A
COMPLETE RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE
PLANNING DEPARTMENT. BELOW EACH COMMENT DESCRIBE HOW YOU
HAVE ADDRESSED EACH REVIEW COMMENT. INDICATE WHICH SHEETS
SHOW THE REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF
REVIEW COMMENTS.
02. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER
17PR0104 IN THE LOWER RIGHT CORNER OF EACH SHEET.
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------PBH TURN LANE
SITE PLAN NUMBER----------17PR0104
ADDRESS-------------------12131, 12015, 12001, 12009 MIDLO
LATEST PLAN DATE----------10/18/16
DEPT. REC'D. DATE---------10/18/16
SUBMITTAL NUMBER----------2
REVIEW DATE---------------11/02/16/16
RECOMMENDATION------------APPROVED
TABLE REVIEW--------------YES
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----NOT REQUIRED
ARCHITECTURAL ELEVATIONS--NOT REQUIRED
LIGHTING PLAN/CUTSHEETS---NOT REQUIRED
IRRIGATION/HOSEBIB PLAN---NOT REQUIRED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A
COMPLETE RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE
PLANNING DEPARTMENT. BELOW EACH COMMENT DESCRIBE HOW YOU
HAVE ADDRESSED EACH REVIEW COMMENT. INDICATE WHICH SHEETS
SHOW THE REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF
REVIEW COMMENTS.
**********************************************************
==========================================================
==========================================================
REVIEW DEPARTMENT: IST / GIS
REVIEWER : AMY JOHANSON 768-7549
NAME OF PLAN : PBH TURN LANE
PLAN NO. : 17PR0104
LATEST PLAN DATE : 6/28/16
RECEIVED DATE : 7/12/16
SUBMITTAL NUMBER : 1
REVIEW DATE : 7/15/16
RECOMMENDATION : APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : PBH TURN LANE
CASE NUMBER : 17PR0104
LATEST PLAN DATE : 10/18/16
RECEIVED DATE : 10/24/16
SUBMITTAL NUMBER : 2
REVIEW DATE : 11/4/16
STATUS : APPROVED
==========================================================
==========================================================
DEPARTMENT REVIEW: IST / HOUSE NUMBERING SECTION
REVIEWER: AMY JOHANSON
PHONE NUMBER: 768-7549
CASE NUMBER: 17PR0104
NAME OF PLAN: PBH TURN LANE
ADDRESS:
DATE OF REVIEW: 7/15/16 REVIEW # 1
STATUS: HOUSE NUMBERING REVIEW NOT NECESSARY
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: PBH TURN LANE
SITE PLAN NUMBER: 17PR0104
ADDRESS: 12131 MIDLOTHIAN TURNPIKE
LATEST PLAN DATE: 6/28/16
DEPT. REC'D. DATE: 7/11/16
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 7/11/16
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: PBH TURN LANE
SITE PLAN NUMBER: 17PR0104
ADDRESS: 12131 MIDLOTHIAN TURNPIKE
LATEST PLAN DATE: 10/1816
DEPT. REC'D. DATE: 10/20/16
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 11/6/16
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE PLAN IS APPROVED AS SUBMITTED.
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : CATHY HILL, P.E. / 768-7836
NAME OF PLAN : PBH TURN LANE
ADDRESS : 12001 - 12131 MIDLOTHIAN TURNPIKE
SITE PLAN NO. : 17PR0104
LATEST PLAN DATE : 06/28/2016 (ENGINEER'S STAMP)
DEPT. REC'D DATE : 07/08/2016
SUBMITTAL NUMBER : 1
REVIEW DATE : 08/01/2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY. WETLANDS DOCUMENTATION MUST BE
RECEIVED BY THIS DEPARTMENT PRIOR TO ISSUANCE OF THE
LAND DISTURBANCE PERMIT.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. EFFECTIVE JULY 1, 2014, ENFORCEMENT OF THE VIRGINIA
STORMWATER REGULATIONS BECAME THE RESPONSIBILITY OF
THE COUNTY FOR DEVELOPMENT PROJECTS WITHIN
CHESTERFIELD COUNTY. ADDITIONALLY, NEW STATE
STORMWATER REGULATIONS ALSO BECAME EFFECTIVE ON
JULY 1, 2014. LAND DISTURBING ACTIVITIES THAT
OBTAINED A VSMP PERMIT PRIOR TO JULY 1, 2014 MAY
USE THE STORMWATER MANAGEMENT CRITERIA SPECIFIED
IN PART II C (9VAC25-870-93 ET SEQ) FOR TWO PERMIT
CYCLES. PROJECTS GRANDFATHERED UNDER THE PROVISIONS
OF 9VAC25-870-48 MAY FOLLOW THE REQUIREMENTS LISTED
UNDER PART IIC FOR ONE PERMIT CYCLE. ALL OTHER NEW
DEVELOPMENT WILL BE SUBJECT TO THE REQUIREMENTS OF
PART IIB (9VAC25-870-62 TO 9VAC25-870-92).
03. PROVIDE THE FOLLOWING INFORMATION ON THE COVER SHEET:
A. TOTAL ON-SITE IMPERVIOUS COVER IN SQUARE FEET (NOT
INCLUDING VDOT RIGHT-OF-WAY IMPERVIOUS COVER).
04. SPECIFY AN ENDWALL ON THE OUTLET END OF STORM PIPE #3.
05. SHOW/LABEL THE RIPRAP OUTLET PROTECTION IN THE PROFILE
VIEW ON SHEET C10. SPECIFY 2' THICK RIPRAP OVER FILTE
FABRIC FOR THE OUTLET PROTECTION.
06. THE DRAINAGE EASEMENT ENCLOSING STORM STRUCTURES
10 - 3 SHOULD BE LABELED "DRAINAGE EASEMENT (PUBLIC)".
07. APPROVAL OF THE SITE PLAN BY THE PRIVATE UTILITY
COMPANY IN RELATION TO ITS EASEMENT AND FACILITIES
THEREIN MUST BE PROVIDED PRIOR TO SITE PLAN APPROVAL.
08. SHEET C02 INDICATES THAT THE EXISTING 15" PIPE BETWEEN
STRUCTURES 12-1 AND 12-2 IS TO BE REMOVED. PLEASE
CLARIFY.
===================== EROSION CONTROL ===================
09. IN THE EC PHASE II CONSTRUCTION NARRATIVE (SHEET C06),
SPECIFY THE INSTALLATION OF INLET PROTECTION UPON THE
INSTALLATION OF DROP INLET STRUCTURE 2.
10. LABEL THE LIMITS OF LAND DISTURBANCE ON SHEET C04.1.
11. SPECIFY INLET PROTECTION FOR STRUCTURE 11-2.
12. THE FOLLOWING NOTE MUST BE ADDED TO OR ADJACENT TO
THE SEQUENCE OF CONSTRUCTION ON SHEET C02:
"ALL ON-SITE AND OFFSITE DRAINAGE EASEMENTS MUST BE
RECORDED PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMI
FOR THIS PROJECT."
13. PROVIDE THE FOLLOWING NOTE ON SHEET C04.1:
"REQUIREMENTS SPECIFIED IN DEQ GUIDANCE MEMO 15-2003
REGARDING LINEAR DEVELOPMENT MUST BE ADHERED TO DURING
CONSTRUCTION OF THE STORM SEWER SYSTEM CONTAINING
STRUCTURES 10 - 3."
===============CBPA/STORMWATER MANAGEMENT ================
14. PROVIDE 1 YEAR, 24-HOUR STORM RUNOFF RATES FOR EACH
OUTFALL, AS REQUIRED BY SECTION 9VAC25-870-66.B.4
TO SHOW THAT THE SITE MEETS CHANNEL PROTECTION
REQUIREMENTS AT THE LIMITS OF ANALYSIS.
THE CALCULATIONS PROVIDED FOR THE 10-YEAR STORM SHOW
THAT THE PROJECT MEETS THE FLOOD PROTECTION
REQUIREMENTS AT THE LIMITS OF ANALYSIS.
15. REVISE THE STORMWATER OUTFALL TABLE ON SHEET C05.2
AS FOLLOWS:
A. CHANGE THE DRAINAGE AREA FOR OUTFALL 1 TO 0.12 ACRES
B. CHANGE THE DRAINAGE AREA FOR OUTFALL 2 TO 0.35 ACRES
C. REVISE THE NOTES BELOW THE STORMWATER OUTFALL TABLE TO
CLEARLY INDICATE OUTFALL 1 IS OUTFALL A, AND OUTFALL 2
IS OUTFALL B.
D. REVISE THE LAST SENTENCE FOR EACH OUTFALL NOTE
DESCRIPTION TO STATE THAT THE OUTFALL LOCATION IS
COINCIDENTAL WITH THE LOCATION AT WHICH THE PEAK
DISCHARGE FROM THE SITE IS LESS THAN 1% OF THE
EXISTING PEAK FLOW RATE OF THE RECEIVING CHANNEL.
16. REVISE THE LEGEND ON THE VRRM PLAN (SHEET C08) AND
ADD THE FOLLOWING NOTE UNDER "DRAINAGE AREA A":
"DISTURBANCE ASSOCIATED WITH STORM PIPE 10-3
INSTALLATION - AREA WILL BE ALLOWED TO RE-ESTABLISH
NATURALLY AND BE MOWED/MAINTAINED LESS THAN 4 TIMES
PER YEAR."
17. REVISE THE VRRM SPREADSHEET AND REMOVE THE DISTURBANCE
ASSOCIATED WITH THE STORM PIPE INSTALLATION. THIS
WILL INCREASE THE REQUIRED OFFSITE CREDIT PURCHASE.
18. REVISE THE CBPA NOTE ON THE COVER SHEET AS NECESSARY.
============== NONPOINT NUTRIENT OFFSETS ===============
19. PRIOR TO PLAN APPROVAL, DOCUMENTATION OF THE OWNER'S
ACQUISITION OF THE NONPOINT NUTRIENT OFFSETS MUST BE
PROVIDED IN A CERTIFICATION FROM THE OFFSET BROKER
DOCUMENTING THE NUMBER OF PHOSPHOROUS NONPOINT NUTRIEN
OFFSETS ACQUIRED AND THE ASSOCIATED RATIO OF NITROGEN
NONPOINT NUTRIENT OFFSETS AT THE OFFSET GENERATING
FACILITY.
20. NOTE THAT THE NONPOINT NUTRIENT OFFSETS USED FOR WATER
QUALITY COMPLIANCE MUST BE GENERATED IN THE SAME OR
ADJACENT EIGHT DIGIT HYDROLOGIC UNIT CODE AS DEFINED B
THE UNITED STATES GEOLOGICAL SURVEY AS THE SITE.
NONPOINT NUTRIENT OFFSETS OUTSIDE THE SAME OR ADJACENT
EIGHT DIGIT HYDROLOGIC UNIT CODE MAY ONLY BE USED IF I
IS DETERMINED THAT NO NONPOINT NUTRIENT OFFSETS ARE
AVAILABLE WITHIN THE SAME OR ADJACENT EIGHT DIGIT
HYDROLOGIC UNIT CODE. IN SUCH CASES, THE NONPOINT
NUTRIENT OFFSETS MUST BE GENERATED WITHIN THE SAME
TRIBUTARY. PROVIDE A HYDROLOGIC UNIT MAP SHOWING THE
LOCATION OF THE PROJECT AND THE OFFSET GENERATING
FACILITY.
======================= CLOSING ========================
21. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
22. PERMISSION MUST BE OBTAINED FROM THE ADJACENT PROPERTY
OWNER(S) ALLOWING FOR GRADING ON THE PROPERTY AS
PROPOSED PRIOR TO ISSUANCE OF A LAND DISTURBANCE
PERMIT.
23. ALL OFFSITE DRAINAGE EASEMENTS MUST BE RECORDED PRIOR
TO ISSUANCE OF A LAND DISTURBANCE PERMIT FOR THIS
PROJECT.
24. ALL ONSITE DRAINAGE EASEMENTS INCLUDING STORMWATER /
BMP DRAINAGE EASEMENTS MUST BE RECORDED PRIOR TO
ISSUANCE OF LAND DISTURBANCE PERMIT FOR THIS PROJECT.
25. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
26. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. THE VIRGINIA STORMWATER MANAGEMENT PERMIT (VSMP)
REGISTRATION STATEMENT AND FEE OF $209
E. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : CATHY HILL, P.E. / 768-7836
NAME OF PLAN : PBH TURN LANE
ADDRESS : 12001 - 12131 MIDLOTHIAN TURNPIKE
SITE PLAN NO. : 17PR0104
LATEST PLAN DATE : 10/18/2016(ENGINEER'S STAMP)
DEPT. REC'D DATE : 10/20/2016
SUBMITTAL NUMBER : 2
REVIEW DATE : 11/14/2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : YES
PLAT PROCESSING : YES
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY. WETLANDS DOCUMENTATION MUST BE
RECEIVED BY THIS DEPARTMENT PRIOR TO ISSUANCE OF THE
LAND DISTURBANCE PERMIT.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. EFFECTIVE JULY 1, 2014, ENFORCEMENT OF THE VIRGINIA
STORMWATER REGULATIONS BECAME THE RESPONSIBILITY OF
THE COUNTY FOR DEVELOPMENT PROJECTS WITHIN
CHESTERFIELD COUNTY. ADDITIONALLY, NEW STATE
STORMWATER REGULATIONS ALSO BECAME EFFECTIVE ON
JULY 1, 2014. LAND DISTURBING ACTIVITIES THAT
OBTAINED A VSMP PERMIT PRIOR TO JULY 1, 2014 MAY
USE THE STORMWATER MANAGEMENT CRITERIA SPECIFIED
IN PART II C (9VAC25-870-93 ET SEQ) FOR TWO PERMIT
CYCLES. PROJECTS GRANDFATHERED UNDER THE PROVISIONS
OF 9VAC25-870-48 MAY FOLLOW THE REQUIREMENTS LISTED
UNDER PART IIC FOR ONE PERMIT CYCLE. ALL OTHER NEW
DEVELOPMENT WILL BE SUBJECT TO THE REQUIREMENTS OF
PART IIB (9VAC25-870-62 TO 9VAC25-870-92).
03. SHEET C02 INDICATES THAT THE EXISTING 15" PIPE BETWEEN
STRUCTURES 12-1 AND 12-2 IS TO BE REMOVED. PLEASE
CLARIFY.
============== NONPOINT NUTRIENT OFFSETS ===============
04. PRIOR TO PLAN APPROVAL, DOCUMENTATION OF THE OWNER'S
ACQUISITION OF THE NONPOINT NUTRIENT OFFSETS MUST BE
PROVIDED IN A CERTIFICATION FROM THE OFFSET BROKER
DOCUMENTING THE NUMBER OF PHOSPHOROUS NONPOINT NUTRIEN
OFFSETS ACQUIRED AND THE ASSOCIATED RATIO OF NITROGEN
NONPOINT NUTRIENT OFFSETS AT THE OFFSET GENERATING
FACILITY.
05. PROVIDE A HYDROLOGIC UNIT MAP SHOWING THE LOCATION OF
THE PROJECT AND THE OFFSET GENERATING FACILITY.
NOTE THAT THE NONPOINT NUTRIENT OFFSETS USED FOR WATER
QUALITY COMPLIANCE MUST BE GENERATED IN THE SAME OR
ADJACENT EIGHT DIGIT HYDROLOGIC UNIT CODE AS DEFINED B
THE UNITED STATES GEOLOGICAL SURVEY AS THE SITE.
NONPOINT NUTRIENT OFFSETS OUTSIDE THE SAME OR ADJACENT
EIGHT DIGIT HYDROLOGIC UNIT CODE MAY ONLY BE USED IF I
IS DETERMINED THAT NO NONPOINT NUTRIENT OFFSETS ARE
AVAILABLE WITHIN THE SAME OR ADJACENT EIGHT DIGIT
HYDROLOGIC UNIT CODE. IN SUCH CASES, THE NONPOINT
NUTRIENT OFFSETS MUST BE GENERATED WITHIN THE SAME
TRIBUTARY.
======================= CLOSING ========================
06. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
07. PERMISSION MUST BE OBTAINED FROM THE ADJACENT PROPERTY
OWNER(S) ALLOWING FOR GRADING ON THE PROPERTY AS
PROPOSED PRIOR TO ISSUANCE OF A LAND DISTURBANCE
PERMIT.
08. ALL OFFSITE DRAINAGE EASEMENTS MUST BE RECORDED PRIOR
TO ISSUANCE OF A LAND DISTURBANCE PERMIT FOR THIS
PROJECT.
09. ALL ONSITE DRAINAGE EASEMENTS INCLUDING STORMWATER /
BMP DRAINAGE EASEMENTS MUST BE RECORDED PRIOR TO
ISSUANCE OF LAND DISTURBANCE PERMIT FOR THIS PROJECT.
10. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
11. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. THE VIRGINIA STORMWATER MANAGEMENT PERMIT (VSMP)
REGISTRATION STATEMENT AND FEE OF $209
E. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================