Site Plan Review Comments
All Site Plan Review Comments for Case # 16PR0258
Modify comments view for Case # 16PR0258

Go to Case Selection Form or Go to Project List

 
CASE NO: 16PR0258 STATUS: APPROVED - ADMIN
PROJECT NAME: INTERNATIONAL SRVC C - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: INDUSTRIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 06/07/16 06/28/16 ******** ********
ENVIR.ENGR.-: 02 02/20/17 03/13/17 ******** 09/26/16 DLD 706-2031
FIRE DEPT.--: 02 02/20/17 03/13/17 COMPLETE 03/03/17 AWB 717-6167
MAPPING/GIS-: 02 02/20/17 03/13/17 COMPLETE 03/10/17 AMJ 768-7549
PLANNING----: 02 02/20/17 03/13/17 COMPLETE 03/16/17 CH 717-6042
TRANSPORT.--: 02 02/20/17 03/13/17 COMPLETE 02/22/17 SJA 751-4461
UTIL.PLAN.--: 02 02/20/17 03/13/17 ******** ********
UTILITIES---: 02 02/20/17 03/13/17 AMENDED* 03/07/17 M L 748-1338
UTIL.R.O.W.-: 02 02/20/17 03/13/17 ******** ********
VDOT--------: 02 02/20/17 03/13/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E. / 804-748-1338
NAME OF PLAN : INTERNATIONAL SERVICE CENTER - CHESTER
ADDRESS : 1521 W HUNDRED ROAD
SUBMISSION DATE : 06/07/16
PLAN DATED : 04/21/16
REVIEW DATE : 06/15/16
SITE PLAN NO. : 16PR0258
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. UTILITIES PROJECT NUMBER 16-0138 SHALL BE PLACED ON
THE LOWER RIGHT HAND CORNER OF EACH SHEET.
2. PLEASE PUT UTILITIES CONTACT MIKE LARSON, P.E. 748-
1338, LARSONM@CHESTERFIELD.GOV ON THE COVER SHEET.
3. SHOW AND LABEL THE EXISTING WATER AND SEWER MAINS WITH
SIZE, MATERIAL, AND COUNTY PROJECT NUMBER ON ALL APPLICABL
PLAN AND PROFILE SHEETS THAT DEPICT EXISTING CONDITIONS OR
A CONNECTION. YOU MAY EMAIL
SWAVAILABILITY@CHESTERFIELD.GOV TO OBTAIN AS-BUILT
INFORMATION.
4. PER APPENDIX 14 OF THE DESIGN STANDARDS AND PROCEDURES
SUBMIT A REQUEST TO OBTAIN A WATER FLOW TEST. THE REQUEST
SHOULD BE DIRECTED TO TERRY MAPLES AT
MAPLEST@CHESTERFIELD.GOV. INCLUDE A COPY OF THE RESULTS O
THE PLANS (DES-06).
5. UPON RECEIPT OF THE WATER FLOW TEST RESULTS, PREPARE
AND INCLUDE A SUMMARY OF RESULTS PER STANDARD DETAIL DES-
05.
6. A SITE UTILIZATION SURVEY FORM MUST BE SUBMITTED AS
PART OF THE SITE PLAN APPLICATION.
7. DUE TO THE NATURE OF THE PROPOSED USE AS AN AUTOMOTIVE
REPAIR FACILITY, THE FOLLOWING ARE REQUIRED: A REDUCED-
PRESSURE PRINCIPLE BACKFLOW PREVENTION DEVICE ON THE
SERVICE LINE, A MONITORING MANHOLE (MAN-17), AND AN
OIL/WATER SEPARATOR. THE MONITORING MANHOLE AND BACKFLOW
PREVENTER SHALL BE LOCATED OUTSIDE OF THE ROW AND PUBLIC
UTILITY EASEMENTS.
8. THE COVER SHEET SHOULD INCLUDE A MATERIALS LIST OF
UTILITIES ITEMS BROKEN OUT BY PRIVATE AND PUBLIC FOR WATER
AND SEWER.
9. PROVIDE STANDARD WATER AND SEWER NOTES, PER
CHESTERFIELD COUNTY STANDARD DETAIL DES-02.
10. PROVIDE THE SITE'S PHYSICAL ADDRESS ON THE COVER
SHEET.
11. PROVIDE A LEGEND IDENTIFYING EXISTING AND PROPOSED
UTILITIES, STRUCTURES, MATERIAL, GROUND COVER, AND PROFILE
GRADE LINES.
12. AS DISCUSSED ON THE PHONE, FIELD-RUN SURVEY TOPO DOES
NOT APPEAR TO MATCH WITH OFFSITE TOPO ALONG THE EXISTING
ASPHALT DRIVEWAY.
13. BENCHMARKS MUST INDICATE ELEVATIONS IN ADDITION TO
NORTHING AND EASTING.
14. AVAILABLE AS-BUILT DATA INDICATES THE PRESENCE OF AN
EXISTING SANITARY MANHOLE INTERIOR TO THE SOUTHEAST
PROPERTY CORNER. VERIFY EXISTING CONDITIONS WITH REGARD T
PUBLIC AND PRIVATE UTILITIES.
15. EXISTING WATER AND SEWER LINES SHALL BE LABELED WITH
SIZE, MATERIAL, AND COUNTY PROJECT NUMBER.
16. SHOW ALL EXISTING ONSITE UTILITY EASEMENTS (PUBLIC AN
PRIVATE). ALL EXISTING WATER AND SEWER EASEMENTS SHALL BE
LABELED WITH WIDTH, MAINTENANCE RESPONSIBILITY, AND DEED
BOOK AND PAGE.
17. ALL EXISTING UTILITIES SHOWN ON THE PROPOSED SITE PLA
SHEETS SHOULD BE SHOWN ON THE EXISTING CONDITIONS PLAN.
18. RIGHT-OF-WAY WIDTH FOR EXISTING RT. 10 MUST BE
INDICATED ON ALL APPLICABLE PLAN SHEETS.
19. USING AVAILABLE ONLINE STREET-VIEW IMAGERY, IT APPEAR
THAT THERE IS AN EXISTING ONSITE FENCE. PLEASE VERIFY IF
THE FENCE IS STILL PRESENT, AND IF SO, INCLUDE IT ON THE
ALL APPLICABLE PLAN SHEETS.
20. PRIVATE DOUBLE DETECTOR CHECK VALVE ASSEMBLY AND
SANITARY CLEANOUT(S) MUST BE LOCATED OUTSIDE OF THE PUBLIC
UTILITY EASEMENTS.
21. PROVIDE REFERENCE DISTANCES FROM PROPOSED WATER AND
SEWER LINES TO ROW, PROPERTY LINES, BUILDINGS, FACE OF
CURB, ETC.
22. PROVIDE TWO (2) VALVES AT EACH TEE. VALVES SHOULD BE
LOCATED SO AS TO FACILITATE LINE ISOLATION AND MAINTENANCE
23. THE TRIPLE CROSSING OF WATER, STORM, AND SEWER LATERA
IS NOT DESIRABLE AND MAY RESULT IN CONFLICTS. PLEASE
REVISIT THE DESIGN AND REVISE IF POSSIBLE.
24. IF A CUT-IN TEE IS TO BE PROVIDED, IDENTIFY THE VALVE
TO BE USED FOR ISOLATING THE LINE. EXISTING CUSTOMERS THA
WILL BE WITHOUT SERVICE MUST BE CONSIDERED. 2 VALVES WILL
NEED TO BE INSTALLED AT THE CUT-IN TEE.
25. WATER METER SIZING FORM MUST BE SIGNED, INCLUDE THE
GPIN, AND THE BUSINESS NAME SHOULD MATCH THE REST OF THE
APPLICATION.
26. AN ADDITIONAL VALVE MUST BE LOCATED ON THE FIRE LINE,
BETWEEN THE DDC VAULT AND THE TEE.
27. IDENTIFY THE MEANS AND EXTENTS OF PAVEMENT RESTORATIO
FOR EXISTING ASPHALT DRIVEWAY.
28. ALL PROPOSED WATER AND SEWER SHALL BE LABELED WITH
SIZE AND MATERIAL.
29. THE PLANS MUST DELINEATE THE END OF COUNTY MAINTENANC
FOR ANY LATERALS CROSSING THE ROW LINE OR EASEMENTS.
30. UTILIZE EXISTING MANHOLE NAMING CONVENTIONS PER AS-
BUILT DATA. PROVIDE MANHOLE LABELS IN PLAN AND PROFILE AN
INDICATE EXISTING MANHOLES.
31. LABELS FOR EXISTING MANHOLES APPEAR TO CONFLICT WITH
REGARD TO ELEVATION.
32. COORDINATE WITH THE COUNTY FIRE MARSHALL TO ENSURE
THAT FIRE HYDRANTS ARE SUFFICIENTLY PROTECTED FROM
VEHICULAR TRAFFIC WITH BOLLARDS OR OTHER ACCEPTABLE MEANS.
33. IF PROPOSED WATER METER BOX IS NOT PLACED BEHIND CURB
AND GUTTER OR OTHERWISE PROTECTED, PROVIDE A CAST IRON
METER BOX PER DETAIL MET-3.
34. INDICATE THAT TRAFFIC RATED CLEANOUTS (PRIVATE) ARE
TYPICAL (TYP) IN PAVED OR GRAVEL AREAS.
35. IDENTIFY THE VERTICAL SCALE FOR PROFILE SHEETS.
36. PROVIDE A PROFILE FOR THE PROPOSED WATER LINE.
37. THE PROPOSED 8" SANITARY LATERAL ON SHEET 9 DOES NOT
MATCH THE SIZE AS INDICATED ON THE PLAN.
38. WATER AND SEWER PROFILES SHALL BE LABELED WITH
EX./PROP. GRADE LINES, DEPTH OF BURY, UTILITY CROSSINGS,
VERTICAL CLEARANCE, SIZE, MATERIAL, ETC. PRIVATE LINES
MUST BE LABELED AS SUCH.
39. PROVIDE THE COUNTY PROJECT NUMBER FOR EXISTING
UTILITIES IN PROFILE VIEW.
40. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF MIKE LARSON
(LARSONM@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
41. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS). ONE ADDITIONAL ROLLED SET WILL BE REQUESTED AFTER
THE PROJECT IS RELEASED TO CONSTRUCTION TO BE USED FOR AS-
BUILTS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E. / 804-748-1338
NAME OF PLAN : INTERNATIONAL SERVICE CENTER - CHESTER
ADDRESS : 1521 W HUNDRED ROAD
SUBMISSION DATE : 08/30/16
PLAN DATED : 08/17/16
REVIEW DATE : 09/12/16
SITE PLAN NO. : 16PR0258
COMMENTS : 2ND REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. COORDINATE WITH VDOT REGARDING THE PROPOSED WIDENING O
ROUTE 10. THE PROPOSED WATERLINE AND THE CONNECTION
LOCATION SHOULD BE COORDINATED TO AVOID CONFLICT WITH THE
WIDENED PAVEMENT, DRAINAGE STRUCTURES, COMMERCIAL
ENTRANCES, ETC.
2. THE PROPOSED WATERLINES WITHIN EASEMENTS OR RIGHT-OF-
WAY ARE PUBLIC. PLEASE REMOVE THE "PRIVATE" LABELS FROM
THESE SECTIONS.
3. LINETYPES IN THE LEGENDS FOR EXISTING AND PROPOSED
UTILITIES APPEAR THE SAME AND DO NOT REPRESENT THE
RESPECTIVE UTILITIES AS SHOWN ON THE PLAN.
4. PLEASE VERIFY AND CLARIFY THE METHOD OF CONNECTION TO
THE EXISTING WATERLINE. SHEET 5 IDENTIFIES A TAPPING
SLEEVE AND VALVE, WHILE SHEET 5A IDENTIFIES A CUT-IN TEE.
5. VERIFY AND CONFIRM THAT THE FLOW TEST RESULTS ARE
ACCEPTABLE TO THE FIRE MARSHAL. THE TEST SHOWN ON THE
PLANS IS DATED AUGUST 2015.
6. IF A TAPPING SLEEVE AND VALVE IS USED, THE PROPOSED
VALVE ON THE EXISTING LINE WILL NOT BE NECESSARY. IN THAT
SCENARIO, PLEASE REMOVE THE SECOND VALVE AND SHOW A SINGLE
VALVE ON THE PROPOSED LINE.
7. THE PROPOSED WATERLINE EASEMENT MUST BE IDENTIFIED AS
SUCH (AS OPPOSED TO "UTILITY EASEMENT").
8. PLEASE IDENTIFY THE WIDTH OF THE PROPOSED WATER
EASEMENT.
9. INDICATE VERTICAL CLEARANCE BETWEEN WATER/SEWER LINES
AND CROSSING UTILITIES IN PROFILE VIEW.
10. THE VERTICAL CLEARANCE BETWEEN WATER AND SEWER AS
SHOWN IN THE SEWER PROFILE ON SHEET 9 DOES NOT MATCH WITH
THE WATER-SEWER CLEARANCE IN THE SHEET 10 WATERLINE
PROFILE. PLEASE VERIFY AND MAKE ANY CORRECTIONS NECESSARY
11. IF 1.5' OF VERTICAL CLEARANCE CANNOT BE MAINTAINED
BETWEEN WATER AND OTHER UTILITIES, CALL OUT COMPACTED STON
AND CENTER A SECTION OF CL52 DUCTILE IRON PIPE AT THE POIN
OF CROSSING.
12. AT APPROXIMATE STATION 0+40 OF WATERLINE PROFILE 1, I
VERTICAL DEFLECTION COMPLIES WITH WAT-8 AND WAT-11,
REPRESENT THE CURVILINEAR VERTICAL ALIGNMENT. OTHERWISE,
SPECIFY VERTICAL BENDS WITH RESTRAINED MECHANICAL JOINTS.
13. IN WATERLINE PROFILE 2, SPECIFY THE PROPER VERTICAL
BENDS WITH RESTRAINED MECHANICAL JOINTS, AND SPECIFY THE
RESTRAINED LENGTH.
14. SUBMIT JOINT RESTRAINT CALCULATIONS (EBAA OR
EQUIVALENT) WITH TEST PRESSURE OF 150 PSI AND A SAFETY
FACTOR OF 1.5:1.
15. ADD STANDARD DETAIL FIR-3A TO THE PLANS.
16. ADD THE PROPOSED OIL-WATER SEPARATOR (PRIVATE) TO THE
MATERIAL QUANTITY LIST ON THE COVER.
17. LABEL PROPOSED WATER AND SEWER PROFILES WITH SIZE AND
MATERIAL.
18. PLEASE HATCH, OR OTHERWISE DIFFERENTIATE, DUCTILE IRO
PIPE IN PROFILE VIEW.
19. PLEASE LABEL EXISTING CONNECTIONS IN PROFILE VIEW WIT
SIZE, MATERIAL, AND COUNTY PROJECT NUMBER.
20. PLEASE SUBMIT A SEPARATE WATER METER SIZING FORM WITH
THE NEXT SUBMISSION.
21. AS A RESULT OF ANY CHANGES TO THE PROPOSED UTILITIES
DUE TO COMMENTS OR DESIGN UPDATES, PLEASE UPDATE THE
MATERIAL QUANTITIES ON THE COVER SHEET ACCORDINGLY.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E. / 804-748-1338
NAME OF PLAN : INTERNATIONAL SERVICE CENTER - CHESTER
ADDRESS : 1521 W HUNDRED ROAD
SUBMISSION DATE : 2/20/17
PLAN DATED : 2/1/17
REVIEW DATE : 3/3/17
SITE PLAN NO. : 16PR0258
COMMENTS : 3RD REVIEW- APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
ONCE ALL APPROVALS HAVE BEEN OBTAINED, SUBMIT 3 SETS OF PL
TO THE UTILITY DEPARTMENT FOR USE DURING CONSTRUCTION.
AS A REMINDER, ALL ON SITE EASEMENTS MUST BE SIGNED PRIOR
RELEASED FOR UTILITY CONSTRUCTION.
.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: INTERNATIONAL SERVICE CENTER - CHESTE
SITE PLAN NUMBER: 16PR0258
LATEST PLAN DATE: 05/05/16
DEPT. REC'D. DATE: 06/09/16
SUBMITTAL NUMBER: ONE
REVIEW DATE: 06/24/16
RECOMMENDATION: NOT APPROVED
PLAT PROCESSING: PERMANENT DRAINAGE ESMT FOR VDOT MAIN
1. COUNTY TRANSPORTATION IS REVIEWING THE PROPOSED SITE
PLAN AS IT RELATES TO THE APPROVED ROUTE 10 WIDENING
PROJECT. COMMENTS WILL BE FORTHCOMING.
ROUTE 10 PROJECT SHOWS A PROPOSED PERMANENT DRAINAGE
EASEMENT FOR VDOT MAINTENANCE ON THE PROPERTY THAT WILL
NEED TO BE PROVIDED PRIOR TO SITE PLAN APPROVAL.
2. LABEL ROUTE 10 COUNTY CLASSIFICATION (MAJOR ARTERIAL) O
THE PLANS.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: INTERNATIONAL SERVICE CENTER - CHESTE
SITE PLAN NUMBER: 16PR0258
LATEST PLAN DATE: 08/17/16
DEPT. REC'D. DATE: 08/29/16
SUBMITTAL NUMBER: TWO
REVIEW DATE: 09/19/16
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: INTERNATIONAL SERVICE CENTER - CHESTE
SITE PLAN NUMBER: 16PR0258
LATEST PLAN DATE: 02/01/17
DEPT. REC'D. DATE: 02/22/17
SUBMITTAL NUMBER: THREE
REVIEW DATE: 02/22/17
RECOMMENDATION: APPROVED
==========================================================
==========================================================
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------INTERNATIONAL SERVICE CENTER
SITE PLAN NUMBER----------16PR0258
ADDRESS-------------------1521 WEST HUNDRED ROAD
LATEST PLAN DATE----------04/21/16
DEPT. REC'D. DATE---------05/26/16
SUBMITTAL NUMBER----------ONE
REVIEW DATE---------------06/30/16
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------NO
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----SUBMITTED
ARCHITECTURAL ELEVATIONS--SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT SUBMITTED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A
COMPLETE RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE
PLANNING DEPARTMENT. BELOW EACH COMMENT DESCRIBE HOW YOU
HAVE ADDRESSED EACH REVIEW COMMENT. INDICATE WHICH SHEETS
SHOW THE REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF
REVIEW COMMENTS.
02. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER
16PR0258 IN THE LOWER RIGHT CORNER OF EACH SHEET.
03. IN THE PROJECT DATA LIST THE ZONING CASES 15SN0614 AND
06SN0114.
04. LIST THE PROPOSED USES AS PRIMARY - TRUCK SERVICE,
ACCESSORY - TRUCK SALES (PER ZONING CASE 06SN0114).
05. SHOW ON THE EXISTING CONDITIONS PLAN ALL ADJACENT
PROPERTIES WITH OWNER NAMES, ZONING, AND CURRENT USES PER
SECTION 19.1-27.F
06. LIST THE DESIGN DISTRICT IN THE PROJECT DATA: ROUTE 10
EAST
07. REMOVE THE SCALE AND NORTH FROM SHEET 9. PROVIDE
CORRECT SCALES FOR THE PROFILES.
08. ADD A NOTE ON THE PLANS: ALL PROPOSED UTILITIES ARE TO
BE INSTALLED UNDERGROUND INCLUDING ELECTRIC, TELEPHONE AND
CATV.
09. THE REQUIRED BUILDING SETBACK ALONG THE WARE BOTTOM
SPRING ROAD IS 60 FEET. 40 FEET IS PROVIDED ON THE PLAN. A
ADMINISTRATIVE VARIANCE TO ALLOW THE BUILDING AND PARKING
CONFIGURATION AS SHOWN HAS BEEN ACCEPTED BY THE DIRECTOR O
PLANNING. SOMEONE FROM THE PLANNING DEPARTMENT WILL PROVID
ADDITIONAL DETAILS ON REVISIONS TO THE DRAFT LETTER
SUBMITTED. A $300 FEE IS REQUIRED FOR THE ADMINISTRATIVE
VARIANCE.
10. PER ZONING CASE 15SN0614 A 'TRUCK STORAGE AREA' FOR
TRUCK SALES IS LIMITED TO THE AREA INDICATED ON EXHIBIT A
OF THE ZONING CASE. REMOVE THE FOUR WESTERN-MOST STORAGE
SPACES THAT ARE SHOWN WITHIN THE WARE BOTTOM SPRING ROAD
SETBACK. THIS LEAVES 5 REMAINING SPACES ALONG THE FRONTAGE
WITHIN THE SETBACK WHICH IS THE MAXIMUM NUMBER ALLOWED BY
THE ZONING CASE.
11. SHOW, LABEL, AND DIMENSION THE BUILDING/PARKING
SETBACKS ON THE SITE PLAN, UTILITY PLAN, EROSION CONTROL
PLAN, GRADING PLAN, AND LANDSCAPE PLAN. SETBACK SHOULD BE
LABELED AS SETBACKS AND NOT BUFFERS.
12. PARKING CALCULATIONS SHOULD BE MODIFIED AS FOLLOWS:
3 SPACES / SERVICE BAY
51 REQUIRED, 51 PROVIDED
1 SPACE / 400 SF SALES, OFFICE, PARTS
15 REQUIRED, 26 PROVIDED (CAN BE REDUCED IF NEEDED)
1 HCP SPACE / 25 SPACES
3 REQUIRED, 3 PROVIDED
13. CLEARLY SHOW THE 3 REQUIRED HANDICAP PARKING SPACES AN
AISLE STRIPING ON ALL PLAN SHEETS.
14. SHOW BUMPER BLOCKS AT ENDS OF PARKING SPACES BETWEEN
HANDICAP ACCESS AISLE AND ENTRANCE TO BUILDING SO THAT CAR
DO NOT ENCROACH INTO HANDICAP PEDESTRIAN PATH.
15. SHOW LOCATION AND DETAILS OF HANDICAP PARKING SIGNAGE.
16. PROVIDE DIMENSIONS FOR ALL PARKING BAYS.
17. INDICATE WHICH AREAS ARE PAVED AND WHICH ARE GRAVEL ON
THE SITE PLAN. MINIMUM DIMENSIONS OF GRAVEL PARKING SPACES
IS 10 X 20 AND SHALL BE DELINEATED WITH BUMPER BLOCKS.
CUSTOMER AND EMPLOYEE PARKING AND DRIVES IN I-2 AND I-3
DISTRICTS MAY BE SURFACED WITH A MINIMUM OF TRIPLE SHOT TA
AND GRAVEL. EDGES OF GRAVEL LOTS SHALL BE RETAINED WITH
EITHER FENCING OR AN EDGE RESTRAINT SYSTEM.
18. PROVIDE A VEHICULAR CONNECTION TO THE ADJACENT PROPERT
AT 1601 WEST HUNDRED ROAD PER ZONING ORDINANCE SECTION
19.1-382.C.2:
INTERNAL CIRCULATION. DIRECT AND CONVENIENT ONSITE
VEHICULAR CIRCULATION AND RECIPROCAL ACCESS BETWEEN
PROPERTIES SHALL BE PROVIDED. THE INTENT IS TO REQUIRE
SHARED ACCESS DRIVES LOCATED TO THE REAR OF BUILDINGS THAT
FRONT ROUTE 10.
19. ON THE SITE PLAN OR LANDSCAPE PLAN, LABEL AREAS WITH
THE SQUARE FOOTAGE PROVIDED FOR INTERIOR PARKING LOT
LANDSCAPING.
20. INTERIOR PARKING LOT LANDSCAPING INCLUDES ISLANDS AND
AREAS WITHIN THE BOUNDARY OF THE PARKING LOT AND NOT THE
PERIMETER OF THE LOT OR ALONG ENTRANCE DRIVES. TREES
COUNTED FOR INTERIOR LANDSCAPING MUST BE INSIDE THE PARKIN
LOT BOUNDARY.
21. AT LEAST 50% OF THE TREES SHALL BE LARGE MATURING TREE
THAT ARE IN ISLANDS WITH A MINIMUM WIDTH OF 15 FEET AND 25
S.F. IN SIZE. SMALL MATURING TREES SHALL BE IN ISLANDS
WITH A MINIMUM WIDTH OF 9 FEET AND BE 150 S.F. IN SIZE.
19.1-253.C.5
22. COUNTY STANDARDS FOR LANDSCAPING SHALL BE LABELED ON
THE SITE PLAN WITHIN THE SETBACK AND BUFFER AREAS.
23. PER SECTION 19.1-27(E), "LANDSCAPE PLANS SHALL BE
CERTIFIED BY A STATE OF VIRGINIA REGISTERED LANDSCAPE
ARCHITECT, NURSERYMAN OR LANDSCAPE DESIGNER." THE COUNTY
CAN NOT REVIEW THE LANDSCAPE PLAN UNTIL IT IS CERTIFIED PE
THIS REQUIREMENT.
24. WIDTH OF PERIMETER YARDS AND BUFFERS AND THE ORDINANCE
STANDARD FOR THE PLANTING OF EACH YARD - SHOW SEPARATE
TABULAR CALCULATION OF REQUIRED AND PROPOSED PLANTINGS FOR
EACH YARD AS FOLLOWS:
WARE BOTTOM SPRING ROAD FRONTAGE SETBACK: 40 FEET (PER
VARIANCE) X 620 FEET WITH LANDSCAPE TREATMENT A
ROUTE 10 FRONTAGE SETBACK: 30 FEET X 195 FEET WITH
LANDSCAPE TREATMENT J
WEST PL SIDE YARD SETBACK: 10 FEET X 195 FEET WITH
LANDSCAPE TREATMENT A
PL OPPOSITE WARE BOTTOM SPRING ROAD SIDE YARD SETBACK: 10
FEET X 720 FEET WITH LANDSCAPE TREATMENT B
EAST PL SIDE YARD SETBACK: 10 FEET X 140 FEET WITH
LANDSCAPE TREATMENT B
25. REFER TO THE ZONING ORDINANCE TABLE 19.1-251.B FOR
PERIMETER LANDSCAPE TREATMENTS. TREES PROVIDED FOR PARKING
LOT LANDSCAPING CAN NOT COUNT TOWARD PERIMETER LANDSCAPING
AND VICE VERSA.
26. REFER TO TABLE 19.1-250.D FOR PLANT MATERIAL SIZE
REQUIREMENTS. NON-NATIVE DECIDUOUS TREES ARE TO BE
SPECIFIED AT 2.5 INCH CALIPER.
27. SPECIFY ONLY CALIPER AND NOT HEIGHT FOR SINGLE STEM
DECIDUOUS TREES.
28. REFER TO TABLE 19.1-250.D FOR PLANT MATERIAL SIZE
REQUIREMENTS. NON-NATIVE DECIDUOUS TREES ARE TO BE
SPECIFIED AT 2.5 INCH CALIPER. NON-NATIVE EVERGREEN TREES
ARE TO BE SPECIFIED AT 7 FEET.
29. IN THE PLANT SCHEDULE LIST PLANTS AS LARGE DECIDUOUS
TREES, SMALL DECIDUOUS TREES, EVERGREEN TREES, MEDIUM
SHRUBS, AND LOW SHRUBS/GROUND COVERS.
30. SHOW ALL AREAS OF EXISTING TREES TO REMAIN AND CLEARLY
LABEL AS SUCH. 19.1-247
31. HEALTHY EXISTING TREES MAY BE CREDITED TOWARD PLANTING
REQUIREMENTS SO LONG AS EXISTING VEGETATION IS REASONABLY
DISTRIBUTED THROUGHOUT THE LENGTH OF THE SETBACK AREA.
32. REMOVAL OF EXISTING TREES WITHIN THE SETBACK OR BUFFER
WITHOUT WRITTEN APPROVAL FROM THE PLANNING DEPARTMENT SHAL
RESULT IN TWO TREES BEING PLANTING FOR EACH TREE REMOVED
33. ANY EXISTING TREES IN SETBACKS THAT ARE APPROVED FOR
REMOVAL SHALL BE SHOWN AS SUCH ON THE EROSION CONTROL,
GRADING AND LANDSCAPE PLANS.
34. PROVIDE STANDARD COUNTY LANDSCAPE NOTES ON THE
LANDSCAPE PLAN. NOTES CAN BE PROVIDED BY THE PLANNING
DEPARTMENT UPON REQUEST.
35. ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH A READILY
AVAILABLE WATER SUPPLY. THE COUNTY ACCEPTS EITHER YARD
HYDRANTS AND/OR HOSE BIBS WITHIN 100 FEET OF ALL NEW
PLANTINGS OR AN IRRIGATION SYSTEM FOR ALL AREAS OF NEW
PLANTINGS. SHOW LOCATION OF HYDRANTS, BIBS OR IRRIGATION
SLEEVES. THE COUNTY ALSO ACCEPTS A 3-YEAR CONTINUOUS
MAINTENANCE CONTRACT WITH A REPUTABLE LANDSCAPING
MAINTENANCE COMPANY. CERTAIN AREAS DIFFICULT TO SERVE WITH
WATER MAY BE PLANTED WITH DROUGHT TOLERANT NATIVE SPECIES.
INSURE WATER INFORMATION IS SUPPLIED ON UTILITY DEPARTMENT
METER SIZING FORMS. 19.1-249.B
36. INSTALLATION SURETY: PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, THE REQUIRED LANDSCAPING IS COMPLETED; O
A FORM OF SURETY SATISFACTORY TO THE DIRECTOR OF PLANNING
IS SUBMITTED IN AN AMOUNT EQUAL TO THE COST OF COMPLETING
THE REQUIRED LANDSCAPING. IF SURETY HAS BEEN SUBMITTED, TH
REQUIRED LANDSCAPING SHALL BE INSTALLED BASED UPON THE
APPROVED PHASING PLAN OR DURING THE FIRST PLANTING SEASON
FOLLOWING DATE OF ISSUANCE OF THE SURETY. 19.1-248.A.2
37. MAINTENANCE GUARANTEE: PRIOR TO RECEIVING AN OCCUPANCY
PERMIT, THE APPLICANT SHALL PROVIDE A LETTER OF GUARANTEE
(COUNTY FORMAT) TO REPLACE ALL UNHEALTHY OR DEAD PLANTS OR
POLLARDED TREES IDENTIFIED BY THE ONE YEAR INSPECTION BY
THE PLANNING DEPARTMENT.
38. TREES ARE NOT TO CONFLICT WITH UNDERGROUND UTILITY
LINES OR LIGHT POLES. MINIMUM DISTANCE TO UTILITIES IS 8
FEET FOR LARGE TREES AND 5 FEET FOR SMALL TREES. MINIMUM
DISTANCE TO LIGHTPOLES IS 15 FEET FOR LARGE TREES.
39. SHOW ON THE LANDSCAPE PLAN OR ADDITIONALLY ON A
SEPARATE LIGHTING PLAN THE LOCATION OF ALL EXTERIOR SITE
LIGHTING MOUNTED ON POLES, THE BUILDING, OR ON THE GROUND
AND HAVE THEM KEYED TO CUT SHEETS FOR EACH LIGHT FIXTURE
SHOWN ON THE PLAN. 19.1-205
40. PROVIDE CATALOG CUTSHEETS FOR EACH EXTERIOR LIGHT
FIXTURE PROPOSED.
41. CONFIRM ALL SPECIFIED FIXTURES ARE FULL CUT OFF,
DOWNWARD DIRECTIONAL, AND DIRECT LIGHT SOURCE SHIELDED FRO
VIEW.
42. PROVIDE 2 COPIES OF COLOR RENDERED ELEVATIONS OF ALL
SIDES OF THE BUILDINGS WITH ALL BUILDING MATERIALS AND
COLORS IDENTIFIED, LOCATIONS OF JUNCTION AND ACCESS BOXES
SHOWN, AND HOW ALL MECHANICAL EQUIPMENT IS SCREENED WHETHE
IT IS MOUNTED ON THE ROOF OR ON THE GROUND. 19.1-27.F
43. IN I-2 AND I-3 DISTRICTS, JUNCTION AND ACCESSORY BOXES
VISIBLE FROM ADJACENT PROPERTY EXCLUDING OTHER I-2 OR I-3
PROPERTY OR FROM ROADS THAT ACCOMMODATE THROUGH TRAFFIC
MOVEMENTS SHALL EITHER BE INTEGRATED INTO THE ARCHITECTURA
TREATMENT OF THE BUILDING OR THEIR VIEW MINIMIZED BY
LANDSCAPING. 19.1-317.C.2
44. ON THE ARCHITECTURAL ELEVATIONS, SHOW IN RELIEF USING
DASHED LINE THE LOCATION OF ROOF TOP MECHANICAL UNITS IN
RELATION TO THE PARAPET WALL. IF THE PLANNING DEPARTMENT
DETERMINES THAT UNITS ARE VISIBLE TO THE PUBLIC, THE
PARAPETS SHALL BE EXTENDED UNTIL THE SCREENING IS
ACCOMPLISHED, BUT NO HIGHER THAN THE TOP OF THE RTU'S. THI
SHALL BE REQUIRED PRIOR TO THE RELEASE OF A TEMPORARY
CERTIFICATE OF OCCUPANCY, OR A BOND PLACED WITH THE COUNTY
FOR THE COST OF THE ADDITIONAL BUILDING.
45. PUT NOTE ON PLANS, "ANY SIGN IN EXCESS OF EIGHT (8)
SQUARE FEET REQUIRES A PERMIT. PERMIT MUST BE OBTAINED
THROUGH BUILDING INSPECTIONS DEPARTMENT." IF A SIGN IS
SHOWN ON THE SITE PLAN, NOTE ON PLAN "SIGNAGE CONTINGENT
UPON APPROVAL THROUGH SIGN PERMIT REVIEW PROCESS."
46. INDICATE NEW FENCING IF PROPOSED OR EXISTING FENCING T
REMAIN.
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------INTERNATIONAL SERVICE CENTER
SITE PLAN NUMBER----------16PR0258
ADDRESS-------------------1521 WEST HUNDRED ROAD
LATEST PLAN DATE----------08/17/16
DEPT. REC'D. DATE---------08/29/16
SUBMITTAL NUMBER----------TWO
REVIEW DATE---------------09/21/16
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------NO
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----SUBMITTED
ARCHITECTURAL ELEVATIONS--SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT SUBMITTED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A
COMPLETE RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE
PLANNING DEPARTMENT. BELOW EACH COMMENT DESCRIBE HOW YOU
HAVE ADDRESSED EACH REVIEW COMMENT. INDICATE WHICH SHEETS
SHOW THE REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF
REVIEW COMMENTS.
02. TIMBER EDGE RESTRAINTS HAVE BEEN PROVIDED FOR GRAVEL
PARKING AREAS FLUSH WITH THE GRAVEL SURFACE. REVISE TO
PROVIDE A MINIMUM 4 INCH HEIGHT FROM THE GRAVEL SURFACE TO
THE TOP OF THE TIMBER. ADD A SECTION DETAIL TO THE DRAWING
SET.
03. LABEL TIMBER RESTRAINTS AT THE EASTERN GRAVEL PARKING
AREA ON THE SITE PLAN.
04. PROVIDE A LEGEND OR LABEL ASPHALT VS. GRAVEL SURFACES
ON THE SITE PLAN
05. LABEL THE 5 TRUCK DISPLAY PARKING SPACES WITHIN THE
FRONT SETBACK AS PROVIDED PER ZONING CASE 15SN0614.
06. BASED ON THE REQUIRED INTERIOR PARKING LOT LANDSCAPING
AREA OF 1980 SF, AT 1/200 SF A TOTAL OF 10 TREES WITH AT
LEAST 5 OF THESE BEING LARGE TREES IS REQUIRED. 8 HAVE BEE
PROVIDED.
07. AREAS FOR PROVIDED INTERIOR PARKING LOT LANDSCAPING
HAVE BEEN LABELED ON THE PLAN. UPDATE THE CALCULATIONS TO
REFLECT THE CORRECT TOTAL PROVIDED AREA.
08. PERIMETER LANDSCAPE J HAS BEEN SHOWN FOR THE 30 FOOT
SETBACK AT ROUTE 10. CONDITION 3 OF ZONING CASE 15SN0615
REQUIRED THAT A LANDSCAPE PLAN BE SUBMITTED FOR THIS
SETBACK. A LANDSCAPE PLAN PREPARED BY BALZER AND ASSOCIATE
DATED 06-11-15 WAS GRANTED ADMINISTRATIVE APPROVAL BY THE
PLANNING DEPARTMENT ON 08-12-15. PER THE CONDITION, THIS
LANDSCAPING WAS TO BE INSTALLED WITHIN 3 MONTHS OF THE
APPROVAL DATE. SHOW THE PROPOSED APPROVED LANDSCAPING FOR
THIS SETBACK ON YOUR PLAN AND ADD A NOTE STATING THAT THIS
PERIMETER LANDSCAPING IS PROVIDED PER ZONING CASE 15SN0615
A COPY OF THE APPROVED LANDSCAPE PLAN WILL BE PROVIDED TO
YOU BY THE PLANNING DEPARTMENT.
09. PER SECTION 19.1-27(E), "LANDSCAPE PLANS SHALL BE
CERTIFIED BY A STATE OF VIRGINIA REGISTERED LANDSCAPE
ARCHITECT, NURSERYMAN OR LANDSCAPE DESIGNER." THE COUNTY
CAN NOT REVIEW THE LANDSCAPE PLAN UNTIL IT IS CERTIFIED PE
THIS REQUIREMENT.
10. STANDARD COUNTY LANDSCAPE NOTES ARE PROVIDED ON DETAIL
SHEET 13. MOVE THESE NOTES TO THE LANDSCAPE PLAN, SHEET 8.
11. A NOTE HAS BEEN PROVIDED ON THE LANDSCAPE PLAN THAT TH
REQUIRED 3 YEAR MAINTENANCE CONTRACT, IN LIEU OF AN
IRRIGATION SYSTEM OR HOSE BIBS, WILL BE PROVIDED. A COPY O
THIS CONTRACT WILL NEED TO BE SUBMITTED TO THE PLANNING
DEPARTMENT PRIOR TO ISSUANCE OF A FINAL OCCUPANCY PERMIT.
12. INSTALLATION SURETY: PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, THE REQUIRED LANDSCAPING IS COMPLETED; O
A FORM OF SURETY SATISFACTORY TO THE DIRECTOR OF PLANNING
IS SUBMITTED IN AN AMOUNT EQUAL TO THE COST OF COMPLETING
THE REQUIRED LANDSCAPING. IF SURETY HAS BEEN SUBMITTED, TH
REQUIRED LANDSCAPING SHALL BE INSTALLED BASED UPON THE
APPROVED PHASING PLAN OR DURING THE FIRST PLANTING SEASON
FOLLOWING DATE OF ISSUANCE OF THE SURETY. 19.1-248.A.2
13. MAINTENANCE GUARANTEE: PRIOR TO RECEIVING AN OCCUPANCY
PERMIT, THE APPLICANT SHALL PROVIDE A LETTER OF GUARANTEE
(COUNTY FORMAT) TO REPLACE ALL UNHEALTHY OR DEAD PLANTS OR
POLLARDED TREES IDENTIFIED BY THE ONE YEAR INSPECTION BY
THE PLANNING DEPARTMENT.
14. SHOW ON THE LANDSCAPE PLAN OR ADDITIONALLY ON A
SEPARATE LIGHTING PLAN THE LOCATION OF ALL EXTERIOR SITE
LIGHTING MOUNTED ON POLES, THE BUILDING, OR ON THE GROUND
AND HAVE THEM KEYED TO CUT SHEETS FOR EACH LIGHT FIXTURE
SHOWN ON THE PLAN. 19.1-205
15. PROVIDE CATALOG CUTSHEETS FOR EACH EXTERIOR LIGHT
FIXTURE PROPOSED.
16. CONFIRM ALL SPECIFIED FIXTURES ARE FULL CUT OFF,
DOWNWARD DIRECTIONAL, AND DIRECT LIGHT SOURCE SHIELDED FRO
VIEW.
17. MINIMUM DISTANCE OF LARGE TREES, FROM THE CENTER OF TH
TREE, TO LIGHT POLES IS 15 FEET.
18. ARCHITECTURAL ELEVATIONS FOR 3 SIDES OF THE BUILDING
HAVE BEEN PROVIDED. SUBMIT ELEVATIONS FOR ALL FOUR SIDES.
IF COLOR RENDERED ELEVATIONS CANNOT BE PROVIDED, ADD NOTES
SPECIFYING ALL EXTERIOR MATERIALS WITH PRODUCT COLORS THAT
CAN BE VIEWED ON MANUFACTURER WEBSITES, OR PROVIDE MATERIA
CUTSHEETS WITH SELECTED COLORS.
19. ON THE ARCHITECTURAL ELEVATIONS, SHOW IN RELIEF USING
DASHED LINE THE LOCATION OF ROOF TOP MECHANICAL UNITS IN
RELATION TO THE PARAPET WALL. IF THE PLANNING DEPARTMENT
DETERMINES THAT UNITS ARE VISIBLE TO THE PUBLIC, THE
PARAPETS SHALL BE EXTENDED UNTIL THE SCREENING IS
ACCOMPLISHED, BUT NO HIGHER THAN THE TOP OF THE RTU'S. THI
SHALL BE REQUIRED PRIOR TO THE RELEASE OF A TEMPORARY
CERTIFICATE OF OCCUPANCY, OR A BOND PLACED WITH THE COUNTY
FOR THE COST OF THE ADDITIONAL BUILDING. IF NO ROOF TOP
UNITS WILL BE USED, INDICATE THIS IN YOUR RESPONSE TO THIS
COMMENT.
20. IN I-2 AND I-3 DISTRICTS, JUNCTION AND ACCESSORY BOXES
VISIBLE FROM ADJACENT PROPERTY EXCLUDING OTHER I-2 OR I-3
PROPERTY OR FROM ROADS THAT ACCOMMODATE THROUGH TRAFFIC
MOVEMENTS SHALL EITHER BE INTEGRATED INTO THE ARCHITECTURA
TREATMENT OF THE BUILDING OR THEIR VIEW MINIMIZED BY
LANDSCAPING. 19.1-317.C.2
**********************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------INTERNATIONAL SERVICE CENTER
SITE PLAN NUMBER----------16PR0258
ADDRESS-------------------1521 WEST HUNDRED ROAD
LATEST PLAN DATE----------02/01/17
DEPT. REC'D. DATE---------02/17/17
SUBMITTAL NUMBER----------3
REVIEW DATE---------------03/16/17
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------YES
PLAT PROCESSING-----------NO
LANDSCAPE PLAN STATUS-----SUBMITTED
ARCHITECTURAL ELEVATIONS--SUBMITTED
LIGHTING PLAN/CUTSHEETS---SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT REQUIRED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS.
RESUBMIT 10 FULL SETS AND ONE COPY OF THE SITE PLAN
SHEET TO THE PLANNING DEPARTMENT FOR YOUR NEXT REVIEW.
PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH
COMMENT DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW
02. IF ALL DEPARTMENTS AGREE TO A TABLE REVIEW, THEN YOU
MAY BRING SUBMITTAL PLAN SETS AND THE COMMENT RESPONSE
LETTER (WITH 3 OF THE 10 PLAN SETS HIGHLIGHTED WITH
REVISIONS SINCE THE LAST REVIEW), ALONG WITH THE RECEIPT
FOR THE REVIEW FEE, IF REQUIRED (PAYABLE AT THE FRONT
COUNTER), TO THE TABLE REVIEW MEETING. COORDINATION WITH
DEPARTMENTS NOT APPROVED ON THE LAST REVIEW PRIOR TO THE
TABLE REVIEW IS ADVISABLE.
03. THE FEE FOR THE NEXT (FOURTH) SITE PLAN SUBMITTAL IS
$350. REFER TO SITE PLAN FEES LISTED IN TABLE 19.1-41.C
OF THE ZONING ORDINANCE.
04. ON SHEET 3 THE LABEL FOR THE TIMBER EDGE RESTRAINT
AT THE WESTERN GRAVEL PARKING AREA STILL READS 'FLUSH
WITH GRAVEL ELEVATION'. CHANGE THE LABEL TO MATCH WHAT
IS PROPOSED IN THE EDGE RESTRAINT DETAIL PROVIDED ON
THIS SHEET.
05. DROUGHT TOLERANT PLANTS HAVE BEEN PROVIDED. NO
IRRIGATION SYSTEM IS REQUIRED. REGULAR WATERING WILL BE
NEEDED DURING THE FIRST GROWING SEASON AFTER PLANTING
FOR PROPER ESTABLISHMENT AND LONG TERM SURVIVAL.
06. REQUIRED LANDSCAPING WHICH IS REMOVED, BECOMES
UNHEALTHY OR DIES, OR IS POLLARDED SHALL BE REPLACED
DURING THE NEXT PLANTING SEASON. 19.1-249.
07. INSTALLATION SURETY: PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, THE REQUIRED LANDSCAPING IS COMPLETED;
OR A FORM OF SURETY SATISFACTORY TO THE DIRECTOR OF
PLANNING IS SUBMITTED IN AN AMOUNT EQUAL TO THE COST OF
COMPLETING THE REQUIRED LANDSCAPING. IF SURETY HAS BEEN
SUBMITTED, THE REQUIRED LANDSCAPING SHALL BE INSTALLED
BASED UPON THE APPROVED PHASING PLAN OR DURING THE FIRST
PLANTING SEASON FOLLOWING DATE OF ISSUANCE OF THE
SURETY. 19.1-248.A.2
08. MAINTENANCE GUARANTEE: PRIOR TO RECEIVING AN
OCCUPANCY PERMIT, THE APPLICANT SHALL PROVIDE A LETTER
OF GUARANTEE (COUNTY FORMAT) TO REPLACE ALL UNHEALTHY OR
DEAD PLANTS OR POLLARDED TREES IDENTIFIED BY THE ONE
YEAR INSPECTION BY THE PLANNING DEPARTMENT.
09. ARCHITECTURAL ELEVATIONS FOR 3 SIDES OF THE BUILDING
HAVE BEEN PROVIDED. SUBMIT ELEVATIONS FOR ALL FOUR
SIDES. IF COLOR RENDERED ELEVATIONS CANNOT BE PROVIDED,
ADD NOTES SPECIFYING ALL EXTERIOR MATERIALS WITH PRODUCT
COLORS THAT CAN BE VIEWED ON MANUFACTURER WEBSITES, OR
PROVIDE MATERIAL CUTSHEETS WITH SELECTED COLORS.
10. ON THE ARCHITECTURAL ELEVATIONS, SHOW IN RELIEF
USING A DASHED LINE THE LOCATION OF ROOF TOP MECHANICAL
UNITS IN RELATION TO THE PARAPET WALL. IF THE PLANNING
DEPARTMENT DETERMINES THAT UNITS ARE VISIBLE TO THE
PUBLIC, THE PARAPETS SHALL BE EXTENDED UNTIL THE
SCREENING IS ACCOMPLISHED, BUT NO HIGHER THAN THE TOP OF
THE RTU'S. THIS SHALL BE REQUIRED PRIOR TO THE RELEASE
OF A TEMPORARY CERTIFICATE OF OCCUPANCY, OR A BOND
PLACED WITH THE COUNTY FOR THE COST OF THE ADDITIONAL
BUILDING. IF NO ROOF TOP UNITS WILL BE USED, INDICATE
THIS IN YOUR RESPONSE TO THIS COMMENT.
11. IN I-2 AND I-3 DISTRICTS, JUNCTION AND ACCESSORY
BOXES VISIBLE FROM ADJACENT PROPERTY EXCLUDING OTHER I-2
OR I-3 PROPERTY OR FROM ROADS THAT ACCOMMODATE THROUGH
TRAFFIC MOVEMENTS SHALL EITHER BE INTEGRATED INTO THE
ARCHITECTURAL TREATMENT OF THE BUILDING OR THEIR VIEW
MINIMIZED BY LANDSCAPING. 19.1-317.C.2
**********************************************************
==========================================================
==========================================================
REVIEW DEPARTMENT: IST / GIS
REVIEWER : AMY JOHANSON 768-7549
NAME OF PLAN : INTERNATIONAL SERVICE CENTER - CHESTER
PLAN NO. : 16PR0258
LATEST PLAN DATE : 4/21/16
RECEIVED DATE : 6/8/16
SUBMITTAL NUMBER : 1
REVIEW DATE : 6/24/16
RECOMMENDATION : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
PARCEL BOUNDARY.
2. IN THE GENERAL NOTES, HORIZONTAL DATUM SHOULD BE
NAD 1983 NOT NAVD 1983
==========================================================
==========================================================
REVIEW DEPARTMENT: IST / GIS
REVIEWER : AMY JOHANSON 768-7549
NAME OF PLAN : INTERNATIONAL SERVICE CENTER - CHESTER
PLAN NO. : 16PR0258
LATEST PLAN DATE : 8/17/16
RECEIVED DATE : 9/1/16
SUBMITTAL NUMBER : 2
REVIEW DATE : 9/16/16
RECOMMENDATION : APPROVED
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : INTERNATIONAL SERVICE CENTER - CHESTER
CASE NUMBER : 16PR0258
LATEST PLAN DATE : 2/1/17
RECEIVED DATE : 2/21/17
SUBMITTAL NUMBER : 3
REVIEW DATE : 3/10/17
ADDRESS : 1521 W HUNDRED RD
STATUS : APPROVED
==========================================================
==========================================================
DEPARTMENT REVIEW: IST / HOUSE NUMBERING SECTION
REVIEWER: AMY JOHANSON
PHONE NUMBER: 768-7549
CASE NUMBER: 16PR0258
NAME OF PLAN: INTERNATIONAL SERVICE CENTER - CHESTER
ADDRESS:
DATE OF REVIEW: 6/24/16 REVIEW # 1
STATUS: HOUSE NUMBERING NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS
CONCERNING THE COMMENTS BELOW.
1) LOCATION OF STREET ADDRESS SIGN IS NOT SHOWN.
(THE ADDRESS CAN BE PART OF YOUR MONUMENT SIGN.
THIS DOES NOT COUNT AS PART OF THE SQUARE FOOTAGE OF
THE SIGN. IF YOU ARE USING THE MONUMENT SIGN FOR THE ADDRE
A DETAIL OF THE MONUMENT SIGN NEEDS TO BE
ON THE SITE PLAN.)
2) SPECIFY THE MATERIAL THAT THE ADDRESS SIGN IS TO BE
MADE OF. (MATERIAL TO BE MORE DURABLE THAN WOOD).
3) IF THE SITE IS ON A THROUGH OR CORNER LOT AND THE
STREET ADDRESS SIGN WILL BE VISIBLE FROM MORE THAN
ONE ROAD, THE STREET NAME SHOULD BE INCLUDED IN THE
SIGN.
==========================================================
==========================================================
DEPARTMENT REVIEW: IST / HOUSE NUMBERING SECTION
REVIEWER: AMY JOHANSON
PHONE NUMBER: 768-7549
CASE NUMBER: 16PR0258
NAME OF PLAN: INTERNATIONAL SERVICE CENTER - CHESTER
ADDRESS: 1521 W HUNDRED RD
DATE OF REVIEW: 9/16/16 REVIEW # 2
STATUS: APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS
CONCERNING THE COMMENTS BELOW.
1) SINCE THE PROPERTY IS ADDRESSED OFF OF W HUNDRED RD,
PLEASE MAKE SURE THE STREET NAME IS INCLUDED IN THE
SIGN (EVEN THOUGH THE SIGN WILL BE LOCATED ON WARE
BOTTOM SPRING RD).
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: INTERNATIONAL SERVICE CENTER
SITE PLAN NUMBER: 16PR0258
ADDRESS: 1610 WARE BOTTOM SPRINGS ROAD
LATEST PLAN DATE: 4/21/16
DEPT. REC'D. DATE: 6/9/16
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 6/10/16
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
PLAT PROCESSING: NO
COMMENTS:
1. ADD THE NOTE TO THE GENERAL NOTES SECTION OF THE PLAN
AND TO THE LANDSCAPING PLANS.
"NO LANDSCAPING OF ANY TYPE SHALL BE PLACED WITHIN A
THREE FOOT RADIUS OF ANY FIRE HYDRANT, FIRE PUMP TEST
HEADER, FIRE DEPARTMENT SPRINKLER SYSTEM CONNECTION,
FIRE DEPARTMENT STANDPIPE CONNECTION OR FIRE SUPPRESSION
CONTROL VALVE. LANDSCAPING IN THE AREA OF FIRE HYDRANTS,
FIRE PUMP TEST HEADERS, FIRE DEPARTMENT SPRINKLER
SYSTEM CONNECTIONS OR FIRE DEPARTMENT STANDPIPE
CONNECTIONS SHALL BE OF THE TYPE THAT WILL NOT ENCROACH
ON THE REQUIRED THREE FOOT CLEAR RADIUS ON MATURITY OF
THE LANDSCAPING"
2. THE FOLLOWING NOTE SHALL BE ADDED TO THE GENERAL
NOTES ON PLANS:
"AN APPROVED KEY BOX SHALL BE PROVIDED FOR THE PROPOSED
BUILDING IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE,
SECTION 506.1 THE REQUIRED FORMS AND INSTALLATION
INSTRUCTIONS FOR THE KEY BOX CAN BE OBTAINED FROM
CHESTERFIELD FIRE AND EMS, FIRE AND LIFE SAFETY DIVISION,
AT 748-1426."
3. THE FOLLOWING SHALL BE ADDED TO THE GENERAL NOTES ON
PLANS FOR BUILDINGS EQUIPPED WITH AN AUTOMATIC FIRE
SPRINKLER SYSTEM AND/OR STANDPIPE SYSTEM: "APPROVAL OF
SITE PLAN DOES NOT INCLUDE THE DESIGN OF THE FIRE
SPRINKLER SYSTEM UNDERGROUND PIPING FROM BACKFLOW
PREVENTION DEVICE TO ONE FOOT ABOVE FINISH FLOOR LEVEL.
PRIOR TO INSTALLATION, SHOP DRAWINGS AND A SEPARATE
PERMIT APPLICATION AND SHALL BE SUBMITTED THROUGH THE
DEPARTMENT OF BUILDING INSPECTIONS FOR REVIEW AND
APPROVAL."
4. PROVIDE COMPUTER GENERATED WATER FLOW TEST DATA,
PROVIDED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT, VERIFYING THE REQUIRED WATER FLOW FOR FIRE
PROTECTION IS AVAILABLE AT THE SITE. THE WATERFLOW TEST
RESULTS AND GRAPH SHALL BE SHOWN ON THE SUBMITTED PLAN.
THE MINIMUM REQUIRED FIRE FLOW FOR ALL BUILDINGS, WITH
THE EXCEPTION OF ONE AND TWO-FAMILY DWELLINGS, IS 1500
GPM (SPRINKLER PROTECTED OR NON-SPRINKLER PROTECTED) IN
ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (2012) -
SECTION B105.2 AND TABLE B105.1.
5. SHOW THE NODE MAP AND RESULTS TABLE FOR THE PROPOSED
OR EXISTING HYDRANTS ON SITE SHOWING THE MAXIMUM FIRE
FLOW CAN BE ACHIEVED. WHEN MULTIPLE FIRE HYDRANTS ARE
USED THE COMBINED FLOW MUST BE SIMULTANEOUS.
6. THE APPROXIMATE LOCATION OF ALL REQUIRED FIRE LANE
SIGNS AND CURB / STREET MARKING SHALL BE INDICATED ON
THE PLAN. FIRE LANES THAT ARE BETWEEN TWENTY AND
TWENTY-SIX FEET IN WIDTH SHALL BE POSTED AND MARKED ON
BOTH SIDES OF THE ROADWAY. FIRE LANES IN EXCESS OF
TWENTY-SIX FEET IN WIDTH UP TO THIRTY-TWO FEET IN WIDTH
SHALL BE POSTED AND MARKED ON ONE SIDE OF THE
ROADWAY. THE LOCATION OF AND METHOD OF MARKING FIRE
LANES SHALL BE CLEARLY INDICATED ON THE SUBMITTED SITE
PLAN. ALL FIRE LANE SIGNS SHALL BE DOUBLE FACED AND
INSTALLED PERPENDICULAR TO THE CURB.
7. PROVIDE THE CHESTERFIELD COUNTY STANDARD FIRE LANE
DETAIL ON THE PLAN.
8. ADD A NOTE TO THE UTILITY PLAN STATING:
"THE 4.5 INCH DISCHARGE OF THE FIRE HYDRANT SHALL FACE
IN THE DIRECTION INDICATED BY THE ARROW ON THE PLAN."
9. ADD AN ARROW TO THE FIRE HYDRANT INDICATING WHICH
DIRECTION IT SHALL FACE.
10. PROVIDE THE REQUIRED THRUST BLOCK DESIGN AND RODDING
DETAIL CHART FOR FIRE PROTECTION UNDERGROUND. ALSO
PROVIDE THE MINIMUM CONCRETE AMOUNT DESIGN CHART. THRUST
BLOCKS FOR FIRE PROTECTION UNDERGROUND SHALL BE DESIGNED
AT A MINIMUM TEST PRESSURE OF 225 PSI. THE REQUIRED
CHARTS AND DETAILS CAN BE OBTAINED FROM THE INTERNET FOR
CHESTERFIELD COUNTY - CHESTERFIELD FIRE AND EMS -
DIVISION OF FIRE AND LIFE SAFETY -
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
11. PROVIDE THE DETAIL FOR THE PLAN AND ELEVATION
(SECTION)VIEW OF THE FIR-3 DOUBLE CHECK ASSEMBLY VAULT
AS PUBLISHED BY THE CHESTERFIELD COUNTY UTILITIES
DEPARTMENT.
12. PROVIDE THE DETAILS FOR THE AUTOMATIC SPRINKLER SYSTEM
RUN-IN AND STUB UP, INCLUDING ALL APPLICABLE NOTES. SEE:
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
FOR A COPY OF THE DETAILS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: INTERNATIONAL SERVICE CENTER
SITE PLAN NUMBER: 16PR0258
ADDRESS: 1610 WARE BOTTOM SPRINGS ROAD
LATEST PLAN DATE: 8/17/16
DEPT. REC'D. DATE: 8/6/16
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 8/9/16
RECOMMENDATION: APPROVED WITH COMMENTS
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. ON THE FIRE FLOW ESTIMATE FORM ON SHEET 5A, CHECK THE Y
UNDER AUTOMATIC SPRINKLER SYSTEM.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: INTERNATIONAL SERVICE CENTER
SITE PLAN NUMBER: 16PR0258
ADDRESS: 1610 WARE BOTTOM SPRINGS ROAD
LATEST PLAN DATE: 2/1/17
DEPT. REC'D. DATE: 2/23/17
SUBMITTAL NUMBER: 3RD REVIEW
REVIEW DATE: 3/3/17
RECOMMENDATION: APPROVED WITH COMMENTS
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. ON THE FIRE FLOW ESTIMATE FORM ON SHEET 5A, CHECK THE Y
UNDER AUTOMATIC SPRINKLER SYSTEM.
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : DUSTIN DUNNAGAN / 706-2061
NAME OF PLAN : INTERNATIONAL SERVICE CENTER - CHESTER
ADDRESS : 1521 WARE BOTTOM SPRING RD
SITE PLAN NO. : 16PR0258
LATEST PLAN DATE : MAY 05, 2016
DEPT. REC'D DATE : JUNE 08, 2016
SUBMITTAL NUMBER : 1
REVIEW DATE : JUNE 28, 2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. IT HAS RECENTLY COME TO OUR ATTENTION THAT THE STATE
STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
REQUIREMENTS CONCERNING THE 10-YEAR STORM PEAK
ATTENUATION AND WATER QUALITY COMPLIANCE, WHICH
VARIES FROM BAY ACT COMPLIANCE, MAY BECOME AN ISSUE
DURING THE STATE SITE INSPECTION PROCESS. COUNTY
CONSTRUCTION PLAN APPROVAL DOES NOT RELIEVE THE
OWNER/DEVELOPER OF RESPONSIBILITY FOR COMPLIANCE WITH
STATE REGULATIONS - E.G. 9VAC25-870-66 WATER QUANTITY
9VAC25-870-63 WATER QUALITY, 9VAC25-870-65 WATER
QUALITY COMPLIANCE, ETC. TECHNICAL ASSISTANCE FROM
DEQ IS AVAILABLE AND RECOMMENDED.
03. CURSORY REVIEW PROVIDED DUE TO EXCESSIVE GENERAL
COMMENTS.
04. PROVIDE THE FOLLOWING INFORMATION ON THE COVER SHEET:
A. LATITUDE AND LONGITUDE FOR THE PROJECT SITE (IN
DEGREES, MINUTES, SECONDS, TO THE NEAREST 15 SECONDS)
B. NAME OF RECEIVING CHANNEL/WATERS
C. VAHU6 FOUR DIGIT WATERSHED CODE
D. TOTAL ON-SITE IMPERVIOUS COVER IN SQUARE FEET (NOT
INCLUDING VDOT RIGHTS-OF-WAY).
05. A BENCHMARK MUST BE SHOWN WITH REFERENCE TO
MEAN SEA LEVEL. (CL-GENERAL 11)
06. ALL ROOF WATER AND DOWNDRAINS MUST BE COLLECTED AND
DISCHARGED IN A NON-ERODIBLE MANNER. (CL-G&D 6)
07. CALCULATIONS MUST BE SUBMITTED TO SUPPORT THE DESIGN O
ALL PROPOSED CULVERTS, OPEN DITCHES, DROP INLETS, AND
STORM SEWERS ON VDOT STANDARD CALCULATION SHEETS.
(CL-G&D 11)
08. ALL EXISTING AND PROPOSED STORM SEWERS, CULVERTS, DROP
INLETS AND APPURTENANCES MUST BE ASSIGNED A STRUCTURE
NUMBER AND LISTED IN TABULAR FORM ON THE PLAN SHEET ON
WHICH THEY ARE LOCATED. (CL-G&D 14)
09. INVERT ELEVATIONS MUST BE SHOWN FOR ALL DRAINAGE
STRUCTURES. (CL-G&D 15)
10. THE THROAT LENGTH FOR ALL CURB DROP INLETS MUST BE
SHOWN. (CL-G&D 16)
11. INLET SHAPING STD. IS-1 MUST BE SPECIFIED IN THE
TABULAR DRAINAGE DESCRIPTION FOR EACH MANHOLE AND DROP
INLET IN WHICH IT WAS USED IN THE HYDRAULIC GRADE LINE
CALCULATIONS. (CL-G&D 17)
12. INLET SHAPING IS RESTRICTED TO PIPE DIAMETERS OF 30"
OR LESS AND TO SITUATIONS WHERE ONE PIPE ENTERS THE
CHAMBER AND ONE PIPE EXITS THE CHAMBER. STORM SEWERS
WITH PIPE DIAMETERS OF 30" AND ABOVE SHALL QUALIFY FOR
THE 50 PERCENT REDUCTION IN JUNCTION LOSSES ONLY WHEN
PRE-CAST TEES AND ELBOWS ARE USED. (CL-G&D 18)
13. A DETAIL MUST BE SHOWN ON THE PLANS FOR INLET SHAPING
STD. IS-1. IF INLET SHAPING CANNOT BE ACCOMPLISHED
WITHIN THE STANDARD STRUCTURE, THEN DETAILS MUST BE
PROVIDED FOR THE MODIFICATIONS NECESSARY TO THE
STRUCTURE TO ACCOMPLISH INLET SHAPING. (CL-G&D 19)
14. STEPS STD. ST-1 MUST BE SPECIFIED IN THE TABULAR
DRAINAGE DESCRIPTION OF ANY STRUCTURE OVER 4 FEET IN
HEIGHT. (CL-G&D 20)
15. BOOT CONNECTORS MUST BE SPECIFIED IN THE TABULAR
DRAINAGE DESCRIPTION FOR ALL PLASTIC PIPES THAT TIE
INTO A CONCRETE STRUCTURE. (CL-G&D 21)
16. TOP OF CURB ELEVATIONS MUST BE SHOWN AT THE NOSE OF AL
RADIAL CURB AND AT ALL APPRECIABLE BREAKS IN HORIZONTA
OR VERTICAL ALIGNMENT. (CL-G&D 22)
17. DRAINAGE EASEMENTS MUST BE SHOWN ALONG ANY STORMWATER
CONVEYANCE SYSTEM WHICH RECEIVES RUNOFF FROM OFFSITE,
FROM A PUBLIC RIGHT OF WAY OR REQUIRES IMPROVEMENTS ON
A DOWNSTREAM PROPERTY OWNER. (CL-G&D 29)
18. A SEPARATE PLAN SHEET MUST BE ADDED WHICH ONLY SHOWS
ALL PROPOSED EASEMENTS AND RIGHT OF WAY TO BE
DEDICATED. METES AND BOUNDS MUST BE PROVIDED.
(CL-G&D 30)
19. THE RADIUS OF ALL RADIAL CURBING MUST BE SHOWN.
(CL-G&D 35)
20. THE EROSION CONTROL PLAN AND SEQUENCE/NARRATIVE MUST B
DIVIDED INTO A MINIMUM OF TWO PHASES.
PHASE I SHALL SHOW THE MINIMAL AMOUNT OF CLEARING TO
INCLUDE DIMENSIONS FOR CONSTRUCTION OF ALL PERIMETER-
CONTROL DEVICES, AND STRATEGICALLY PLACED SEDIMENT
TRAPS AND BASINS, ASSOCIATED DIVERSIONS AND DIVERSION
DIKES, AND SPOIL AND BORROW AREAS FOR THE INSTALLATION
OF EROSION CONTROL MEASURES.
PHASE II WILL INCLUDE ALL REMAINING CLEARING, GRADING,
AND INSTALLATION OF REMAINING EROSION CONTROL DEVICES,
INSTALLATION OF TEMPORARY AND PERMANENT IMPROVEMENTS,
AND TEMPORARY AND PERMANENT SEEDING AND STABILIZATION.
(CL-EC 1)
21. A NOTE MUST BE ADDED TO THE CONSTRUCTION SEQUENCE WHIC
REQUIRES THE OWNER TO GIVE THE COUNTY INSPECTOR 48
HOURS NOTIFICATION TO SCHEDULE AN ON-SITE PRE-
CONSTRUCTION MEETING FOR THE ISSUANCE OF A LAND
DISTURBANCE PERMIT. THIS NOTE SHOULD BE THE FIRST STE
IN THE EROSION CONTROL NARRATIVE/SEQUENCE OF
CONSTRUCTION. (CL-EC 4)
22. A NOTE MUST BE ADDED TO THE SEQUENCE OF CONSTRUCTION
STATING THAT THE CERTIFIED RESPONSIBLE LAND DISTURBER
(CRLD) MUST ATTEND THE PRE-CONSTRUCTION MEETING.
(CL-EC 5)
23. A NOTE MUST BE ADDED TO THE SEQUENCE OF CONSTRUCTION
STATING THAT THE VSMP CONSTRUCTION ACTIVITY OPERATOR
AND THE ENVIRONMENTAL INSPECTOR (OR AUTHORIZED
REPRESENTATIVE) MUST ATTEND THE PRE-CONSTRUCTION
MEETING.
24. THE CONSTRUCTION ENTRANCE MUST BE GRAPHICALLY SHOWN ON
THE PLANS AND CONSTRUCTED AS WIDE AS THE PROPOSED
PERMANENT ENTRANCE. (CL-EC 9)
25. EROSION CONTROL MEASURES MUST BE PROVIDED FOR THE
PROJECT FOR THE INITIAL CLEARING, GRUBBING AND GRADING
OPERATIONS. THE DRAINAGE AREAS MUST BE OUTLINED FOR
EACH PHASE AND THE SEDIMENT TRAPPING FACILITIES
DESIGNED ON THE WORST CASE SCENARIO. (CL-EC 10)
26. THE DRAINAGE AREA, SPILLWAY LENGTH, AND DIMENSIONS
NECESSARY TO ACHIEVE THE REQUIRED STORAGE VOLUMES IN
ACCORDANCE WITH STD. & SPEC. 3.13 MUST BE SHOWN. THE
ELEVATIONS OF THE TRAP BOTTOM, TOP OF WET VOLUME, TOP
OF DRY VOLUME, AND TOP OF EMBANKMENT MUST BE SHOWN
ON THE SEDIMENT TRAP DETAIL. (CL-EC 12)
27. PLEASE SPECIFY IF THE LENGTH AND WIDTH DIMENSIONS FOR
THE SEDIMENT TRAP(S) REFER TO THE BOTTOM OR TOP OF
THE EXCAVATED AREA. (CL-EC 13)
28. ALL THE INFORMATION NECESSARY FOR CONSTRUCTION OF THE
SEDIMENT TRAP(S) MUST BE SHOWN ON THE SEDIMENT TRAP
DETAIL. (CL-EC 14)
29. SAFETY FENCE (STD. & SPEC 3.01) IS REQUIRED AROUND ALL
SEDIMENT TRAPS AND SEDIMENT BASINS. (CL-EC 15)
30. A MINIMUM 10' BREAK MUST BE PROVIDED IN THE LOW AREA O
THE SILT FENCE . THE BREAK MUST BE BACKFILLED WITH
STONE TO WITHIN 1' OF THE TOP OF THE SILT FENCE TO
SERVE AS AN OVERFLOW. A DETAIL MUST BE SHOWN.
(CL-EC 16)
31. THE MOST RECENT VERSION OF EROSION CONTROL MINIMUM
STANDARD # 1, (SEE THE VIRGINIA EROSION AND SEDIMENT
CONTROL LAW AND REGULATIONS FOR FY 2013) MUST BE ADDED
TO THE PLANS AND ALL OTHER NOTES WHICH ARE IN CONFLICT
MUST BE ADJUSTED OR REMOVED. (CL-EC 25)
32. TABLE 3.31-B AND TABLE 3.32-D, FOUND IN THE CURRENT
EDITION OF THE VIRGINIA EROSION AND SEDIMENT CONTROL
HANDBOOK, MUST BE PROVIDED ON THE EROSION CONTROL PLAN
SHEETS. (CL-EC 26)
33. THE EXACT LIMITS OF LAND DISTURBANCE MUST BE SHOWN.
(CL-EC 27)
34. THE OFF-SITE UTILITY LINE(S) MUST BE SHOWN ON THE
EROSION CONTROL PLAN SHEETS WITH SILT FENCE ON THE
DOWNSTREAM SIDE. (CL-EC 38)
35. ANY SOIL STOCKPILE AREA MUST BE LOCATED ON THE PLANS.
SILT FENCE MUST BE PROVIDED AROUND THE PERIMETER.
(CL-EC 39)
36. ALL SILT MUST BE CLEANED FROM THE SEDIMENT BASIN PRIOR
TO CONVERSION TO THE SWM/BMP. A NOTE MUST BE PROVIDED
IN THE EROSION CONTROL NARRATIVE. (CL-EC 41)
37. THE FOLLOWING NOTE(S) MUST BE ADDED TO OR ADJACENT TO
THE SEQUENCE OF CONSTRUCTION: (CL-EC 42)
A. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
SURETY FOR THE CONSTRUCTION OF THE PERMANENT BMP MUST
BE POSTED WITH ENVIRONMENTAL ENGINEERING. (COUNTY CODE
PART II, CHAPTER 8, SEC. 8-16)
B. THE BMP MUST BE CERTIFIED PRIOR TO RELEASE OF THE BMP
PERFORMANCE BOND.
C. A VDOT LAND USE PERMIT IS REQUIRED FOR THIS PROJECT
PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT.
(CL-EC 42D)
D. AT THE TIME OF THE PRE-CONSTRUCTION MEETING, TWO
STANDARD SIGNS MUST BE INSTALLED ON EACH SIDE OF THE
CONSTRUCTION ACCESS. THESE SIGNS SHOULD STATE EITHER
"CONSTRUCTION ENTRANCE AHEAD" OR "TRUCKS ENTERING
HIGHWAY". (CL-EC 42E)
38. A STORMWATER COMPLIANCE SHEET(S) IS REQUIRED FOR
PROJECTS UTILIZING PART IIB OF THE CURRENT VIRGINIA
STORMWATER REGULATIONS. THE FOLLOWING INFORMATION IS
REQUIRED TO BE SHOWN ON THE SHEET(S):
A. THE CHESTERFIELD COUNTY STORMWATER COMPLIANCE AND
STORMWATER OUTFALL TABLES (FOUND ON THE COUNTY'S
ENVIRONMENTAL ENGINEERING WEBPAGE, UNDER "DOCUMENTS AN
FORMS")
B. ENERGY BALANCE AND OUTFALL ANALYSIS FOR EACH OUTFALL
FOR THE PROJECT
C. DELINEATION OF THE SOIL TYPES (INCLUDE HYDROLOGIC SOIL
GROUP) AND THE THREE LAND COVER CONDITIONS
(FORESTED/OPEN SPACE, MANAGED TURF, IMPERVIOUS)
D. NATURAL VEGETATED AREA EASEMENTS FOR AREAS CLAIMED AS
FORESTED/OPEN SPACE IN THE VRRM SPREADSHEET, THAT ARE
NOT ENCOMPASSED BY A BMP EASEMENT, RPA OR WITHIN A
PLANNING BUFFER/TREE SAVE AREA
E. BMP SIZE, LOCATION, AND GRADING PLAN (1"=20')
F. BMP AND OUTLET STRUCTURE PROFILE AND DETAILS. THE
PROFILE MUST SPECIFY THE WATER QUALITY, 2 YEAR,
10 YEAR,AND 100 YEAR WATER SURFACE ELEVATIONS WITH
THEIR RESPECTIVE VOLUMES. (CL-CBPA 4F)
G. DETAILS AND SPECIFICATION FOR MANUFACTURED BMPS
H. INCREMENTAL DRAINAGE AREAS TO EACH BMP, AND THE LAND
COVER TYPES WITHIN EACH DRAINAGE AREA (CL-CBPA 4H)
I. PROVIDE CHANNEL AND FLOOD PROTECTION CALCULATIONS
J. PROPOSED EASEMENT LOCAITONS
39. VEHICULAR SAFETY MEASURES ARE REQUIRED ALONG PARKING
SPACES AND DRIVE AISLES ADJACENT TO RETENTION AND
DETENTION FACILITIES. (CL-CBPA 10)
40. THE ENTIRE BASIN MUST BE ENCLOSED WITHIN AN SWM/BMP
EASEMENT WHICH EXTENDS 8 FT. BEYOND THE 100-YEAR WSE.
OR DOWNSTREAM TOE OF DAM, WHICHEVER APPLIES.
(CL-CBPA 14)
41. METES AND BOUNDS MUST BE PROVIDED ON THE PLAN SHEET FO
SWM/BMP EASEMENTS AND ACCESS EASEMENTS. (CL-CBPA 16)
42. A MINIMUM 12 FOOT WIDE RAMP MUST BE PROVIDED FROM THE
ACCESS GATE TO THE BOTTOM OF THE SWM/BMP FACILITY. TH
SLOPE CANNOT EXCEED 6:1. (CL-CBPA 17)
43. A PROFILE VIEW MUST BE PROVIDED FOR THE SWM/BMP
FACILITY WHICH SHOWS ALL THE DETAIL CONSTRUCTION
INFORMATION WHICH WILL BE NECESSARY FOR ITS FUTURE
CERTIFICATION. (CL-CBPA 21)
44. THE REQUIRED STORAGE VOLUMES FOR WATER QUALITY AND
WATER QUANTITY MUST BE SHOWN ON THE PROFILE VIEW OF
THE BASIN. (CL-CBPA 22)
45. THE TOP OF THE DAM FOR THE BMP MUST BE AT LEAST 8 FEET
WIDE. DIMENSION AND LABEL IN THE PROFILE VIEW.
(CL-CBPA 23)
46. THE 1, 10, AND 100 YEAR WATER SURFACE ELEVATIONS MUST
BE SHOWN FOR ALL SWM/BMP FACILITIES ON THE PLAN AND
PROFILE VIEWS. (CL-CBPA 24)
47. PERFORATIONS IN THE RISER MUST BE PRECAST, NOT FIELD
MADE. PLEASE ADD A NOTE TO THE RISER DETAIL.
(CL-CBPA 26)
48. A MINIMUM OF 1 FOOT OF FREEBOARD IS REQUIRED BETWEEN
THE TOP OF THE EMBANKMENT AND THE STAGED 100-YEAR
WATER SURFACE ELEVATION IF AN EMERGENCY SPILLWAY IS
SPECIFIED. TWO FEET OF FREEBOARD IS REQUIRED IF THERE
IS NO EMERGENCY SPILLWAY. (CL-CBPA 27)
49. ALL BARREL AND RISER ASSEMBLIES MUST BE "O-RING"
CONCRETE PIPE, NO SMALLER THAN 15 INCHES IN DIAMETER.
(CL-CBPA 29)
50. A TRASH RACK MUST BE PROVIDED FOR THE RISER ASSEMBLY.
A DETAIL IS REQUIRED. (CL-CBPA 30)
51. A DETAIL MUST BE PROVIDED ON THE PLAN SHOWING THE
METHOD OF SECURING THE METAL TRASH RACK / ANTI VORTEX
DEVICE TO THE CONCRETE RISER PIPE. (CL-CBPA 31)
52. THE SIDE SLOPES IN SWM/BMP FACILITIES SHALL BE NO
STEEPER THAN THREE TO ONE (3:1). LABEL IN THE PROFILE
VIEW. (CL-CBPA 37)
53. PROVISIONS MUST BE MADE IN THE EROSION CONTROL
NARRATIVE FOR CONVERSION OF THE SEDIMENT BASIN INTO A
SWM/BMP FACILITY AFTER THE UPSTREAM AREAS ARE FULLY
STABILIZED. ALL EXISTING SILT MUST BE REMOVED FROM TH
BASIN. (CL-CBPA 39)
54. PROVISIONS MUST BE MADE IN THE EROSION CONTROL
NARRATIVE FOR THE SWM/BMP FACILITY TO BE OBSERVED
BY A PROFESSIONAL ENGINEER DURING CONSTRUCTION. "AS
BUILT" INFORMATION WILL BE REQUIRED FOR FUTURE
CERTIFICATION OF THE FACILITY. CERTIFICATION IS
REQUIRED PRIOR TO RELEASE OF THE SWM/BMP PERFORMANCE
BOND AND ANY CERTIFICATE OF OCCUPANCY. (CL-CBPA 42)
55. PRIOR TO PLAN APPROVAL, DOCUMENTATION OF THE OWNER'S
ACQUISITION OF THE NONPOINT NUTRIENT OFFSETS MUST BE
PROVIDED IN A CERTIFICATION FROM THE OFFSET BROKER
DOCUMENTING THE NUMBER OF PHOSPHOROUS NONPOINT NUTRIEN
OFFSETS ACQUIRED AND THE ASSOCIATED RATIO OF NITROGEN
NONPOINT NUTRIENT OFFSETS AT THE OFFSET GENERATING
FACILITY.
56. NOTE THAT THE NONPOINT NUTRIENT OFFSETS USED FOR WATER
QUALITY COMPLIANCE MUST BE GENERATED IN THE SAME OR
ADJACENT EIGHT DIGIT HYDROLOGIC UNIT CODE AS DEFINED B
THE UNITED STATES GEOLOGICAL SURVEY AS THE SITE.
NONPOINT NUTRIENT OFFSETS OUTSIDE THE SAME OR ADJACENT
EIGHT DIGIT HYDROLOGIC UNIT CODE MAY ONLY BE USED IF I
IS DETERMINED THAT NO NONPOINT NUTRIENT OFFSETS ARE
AVAILABLE WITHIN THE SAME OR ADJACENT EIGHT DIGIT
HYDROLOGIC UNIT CODE. IN SUCH CASES, THE NONPOINT
NUTRIENT OFFSETS MUST BE GENERATED WITHIN THE SAME
TRIBUTARY. PROVIDE A HYDROLOGIC UNIT MAP SHOWING THE
LOCATION OF THE PROJECT AND THE OFFSET GENERATING
FACILITY.
57. THE CBPA COMPLIANCE NOTE MUST SPECIFY THE NUMBER OF
PHOSPHOROUS NONPOINT NUTRIENT OFFSETS ACQUIRED
AND THE NAME OF THE OFFSET GENERATING FACILITY.
58. SHEET 4:
A) ENSURE 2' OF COVER IS PROVIDED FOR PIPES IN
TRAFFICKED AREAS.
B) ENSURE STRUCTURES ARE MEETING VDOT MINIMUM HEIGHT
REQUIREMENTS.
C) SOME OF THE TEXT IS OBSCURED AND DIFFICULT TO READ.
D) LABEL DRAINAGE AREA AND INFORMATION FOR INLETS.
E) LICENSE AGREEMENT WILL BE REQUIRED FOR ANY PART OF
THE BUILDING WITHIN THE BMP AND DRAINAGE EASEMENTS.
59. SHEET 6:
A) PROVIDE DRAINAGE AREA INFORMATION AND LABELS.
B) SHOW AREAS A1 AND A2.
C) PROVIDE EXISTING DRAINAGE AREA INFORMATION.
D) BASED ON INFORMATION FROM ROUTINGS IT DOES NOT
APPEAR DRAINAGE AREA A MEETS ENERGY BALANCE.
60. SHEET 7:
A) PROVIDE CULVERT INLET PROTECTION FOR CULVERT UNDER
ENTRANCE AND UNDER WARE BOTTOM SPRING ROAD.
B) PROVIDE INLET PROTECTION OR A ROCK FOREBAY FOR TRAP
DISCHARGE TO STORM SEWER.
C) PROVIDE NOTES FOR CONTRACTOR TO FLUSH STORM SEWER
LINE FROM THE SEDIMENT TRAP.
D) PROVIDE SILT FENCE ALONG THE WESTERN PARKING LOT.
E) SHOW THE SAFETY FENCE INDICATED IN THE CONSTRUCTION
NARRATIVE.
F) CLARIFY WHICH DEPARTMENT IS MEANT BY "CHESTERFIELD
COUNTY PUBLIC WORKS". CHESTERFIELD DOES NOT HAVE A
PUBLIC WORKS DEPARTMENT.
61. SHEET 8:
A) REMOVE TREES FROM WITHIN BMP EASEMENT.
B) SHOW STORM SEWER.
62. SHEET 9:
A) SHOW AND LABEL UTILITY CROSSINGS AND REQUIRED
SEPARATIONS.
63. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
64. PERMISSION MUST BE OBTAINED FROM THE ADJACENT PROPERTY
OWNER(S) ALLOWING FOR GRADING ON THE PROPERTY AS
PROPOSED PRIOR TO ISSUANCE OF A LAND DISTURBANCE
PERMIT.
65. ALL ONSITE DRAINAGE EASEMENTS INCLUDING STORMWATER /
BMP DRAINAGE EASEMENTS MUST BE RECORDED PRIOR TO
ISSUANCE OF A BUILDING PERMIT FOR THIS PROJECT.
66. THE POLLUTION PREVENTION PLAN MUST BE PROVIDED TO THE
ENVIRONMENTAL ENGINEERING INSPECTOR PRIOR TO ISSUANCE
OF A LAND DISTURBANCE PERMIT. THE CHESTERFIELD COUNTY
POLLUTION PREVENTION PLAN SHEET MAY BE PROVIDED IN THE
CONSTRUCTION PLANS (THIS IS AVAILABLE ON THE
ENVIRONMENTAL ENGINEERING DOCUMENTS AND FORMS WEBPAGE)
67. AS-BUILT BMP INFORMATION WILL BE REQUIRED FOR EACH
BMP FACILITY AS PART OF ITS FUTURE CERTIFICATION.
68. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
SURETY FOR THE CONSTRUCTION OF THE PERMANENT BMP MUST
BE POSTED WITH ENVIRONMENTAL ENGINEERING. (COUNTY CODE
PART II, CHAPTER 8, SEC. 8-16)
69. THE BMP MUST BE CERTIFIED PRIOR TO RELEASE OF THE BMP
PERFORMANCE BOND.
70. THE RISER AND BARREL PIPE ASSOCIATED WITH THE SEDIMENT
BASIN MUST BE ON-SITE PRIOR TO ISSUANCE OF A LAND
DISTURBANCE PERMIT.
71. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
72. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
73. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. THE VIRGINIA STORMWATER MANAGEMENT PERMIT (VSMP)
REGISTRATION STATEMENT AND FEE OF $2,700
D. THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) BOOK
E. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : DUSTIN DUNNAGAN / 706-2061
NAME OF PLAN : INTERNATIONAL SERVICE CENTER - CHESTER
ADDRESS : 1521 WARE BOTTOM SPRING RD
SITE PLAN NO. : 16PR0258
LATEST PLAN DATE : AUGUST 17, 2016
DEPT. REC'D DATE : AUGUST 31, 2016
SUBMITTAL NUMBER : 2
REVIEW DATE : SEPTEMBER 23, 2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. IT HAS RECENTLY COME TO OUR ATTENTION THAT THE STATE
STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
REQUIREMENTS CONCERNING THE 10-YEAR STORM PEAK
ATTENUATION AND WATER QUALITY COMPLIANCE, WHICH
VARIES FROM BAY ACT COMPLIANCE, MAY BECOME AN ISSUE
DURING THE STATE SITE INSPECTION PROCESS. COUNTY
CONSTRUCTION PLAN APPROVAL DOES NOT RELIEVE THE
OWNER/DEVELOPER OF RESPONSIBILITY FOR COMPLIANCE WITH
STATE REGULATIONS - E.G. 9VAC25-870-66 WATER QUANTITY
9VAC25-870-63 WATER QUALITY, 9VAC25-870-65 WATER
QUALITY COMPLIANCE, ETC. TECHNICAL ASSISTANCE FROM
DEQ IS AVAILABLE AND RECOMMENDED.
03. PRIOR TO PLAN APPROVAL, DOCUMENTATION OF THE OWNER'S
ACQUISITION OF THE NONPOINT NUTRIENT OFFSETS MUST BE
PROVIDED IN A CERTIFICATION FROM THE OFFSET BROKER
DOCUMENTING THE NUMBER OF PHOSPHOROUS NONPOINT NUTRIEN
OFFSETS ACQUIRED AND THE ASSOCIATED RATIO OF NITROGEN
NONPOINT NUTRIENT OFFSETS AT THE OFFSET GENERATING
FACILITY.
04. NOTE THAT THE NONPOINT NUTRIENT OFFSETS USED FOR WATER
QUALITY COMPLIANCE MUST BE GENERATED IN THE SAME OR
ADJACENT EIGHT DIGIT HYDROLOGIC UNIT CODE AS DEFINED B
THE UNITED STATES GEOLOGICAL SURVEY AS THE SITE.
NONPOINT NUTRIENT OFFSETS OUTSIDE THE SAME OR ADJACENT
EIGHT DIGIT HYDROLOGIC UNIT CODE MAY ONLY BE USED IF I
IS DETERMINED THAT NO NONPOINT NUTRIENT OFFSETS ARE
AVAILABLE WITHIN THE SAME OR ADJACENT EIGHT DIGIT
HYDROLOGIC UNIT CODE. IN SUCH CASES, THE NONPOINT
NUTRIENT OFFSETS MUST BE GENERATED WITHIN THE SAME
TRIBUTARY. PROVIDE A HYDROLOGIC UNIT MAP SHOWING THE
LOCATION OF THE PROJECT AND THE OFFSET GENERATING
FACILITY.
05. SHEET 2:
A) ON ALL APPLICABLE SHEETS, ENSURE THE DRAINAGE AREAS
INCLUDE OFF-SITE AND ON-SITE AREAS. THE CHANNEL AN
FLOOD PROTECTION CALCULATIONS ARE FOR ONSITE AREAS;
HOWEVER, IT SHOULD ACCOUNT FOR OFFSITE AREAS AS
REQUIRED.
06. SHEET 3:
A) PROVIDE HATCHING LEGEND FOR THE PAVEMENT COVERS.
07. SHEET 4:
A) THE LINETYPE FOR PROPERTY BOUNDARY, EASEMENTS, AND
DRAINAGE AREAS ARE VERY SIMILAR. PLEASE USE
DIFFERING LINETYPES TO BETTER DIFFERENTIATE BETWEEN
THE THREE.
B) PROVIDE EDGE OF PAVEMENT ELEVATIONS FOR THE PAVED
AND GRAVELED AREAS NEAR THE BUILDING TO THE EAST.
C) CLARIFY IF THE GRAVEL APRON FOR THE ROOF DRAINS IS
TO HAVE FILTER FABRIC.
D) THE DRAINAGE AREAS APPEAR TO NOT FULLY ENCOMPASS TH
AREAS DRAINING TO THEM. ENSURE THE DRAINAGE AREAS
ARE RUNNING THROUGH HIGH POINTS AND DO NOT INCLUDE
AREAS DOWNSTREAM THAT WOULD NOT ENTER THE INLETS.
E) IT IS SUGGESTED TO EXTEND THE 12" RCP TO THE WEST
ONTO THE SITE PROPERTY OR CONNECT WITH AN INLET.
F) THE PIPE SUMMARY TABLE IS OVERLAPPING THE INLET
INFORMATION FOR THE DROP INLET IN VDOT RIGHT-OF-WAY
ALONG ROUTE 10.
G) PROVIDE AN INLET OR OTHER CONVEYANCE SYSTEM FOR THE
GRAVEL PARKING BY THE BUILDING TO THE EAST TO ENSURE
IT ENTERS THE STORM SEWER SYSTEM IN A NON-EROSIVE
FASHION.
08. SHEET 6:
A) PROVIDE CHANNEL AND FLOOD PROTECTION CALCULATIONS
AND ANALYSIS FOR THE ENTRANCE IMPROVEMENTS OFF OF
WARE BOTTOM SPRINGS ROAD.
09. SHEET 7A:
A) CLARIFY IF THE SITE WILL BE OPEN FOR BUSINESS DURIN
CONSTRUCTION AND HOW CONSTRUCTION PRACTICES AND
SEQUENCING WILL BE USED TO ACCOMMODATE THE BUSINESS
AND EMPLOYEE TRAFFIC.
B) SHOW AND LABEL THE DRAINAGE AREA FOR THE SEDIMENT
TRAP. ENSURE THE TRAP IS DESIGNED FOR THE WORST
CASE DURING CONSTRUCTION.
C) IT APPEARS THE CULVERT INLET PROTECTION FOR THE
WESTERN ENTRANCE IS ON THE DOWNSTREAM SIDE.
D) ENSURE THE CREST LENGTH FOR THE SPILLWAY MEETS THE
REQUIREMENT OF 6*DA (IN ACRES).
E) REVISE NOTE 1 IN THE PHASE 1 SEQUENCE OF
CONSTRUCTION TO BE THE "ENVIRONMENTAL ENGINEERING"
INSTEAD OF DIVISION. THE COUNTY HAS AN
ENVIRONMENTAL DIVISION THAT OPERATES UNDER GENERAL
SERVICES AND FOCUSES ON MANAGING LANDFILLS AND OTHE
WASTE MANAGEMENT.
F) INCLUDE INSTALLATION OF ROCK OUTLETS IN THE
SEQUENCING.
10. SHEET 7B:
A) RELABEL SHEET TO INCLUDE PHASE 2 ESC.
B) REMOVE THE TABLE FOR COASTAL PLAIN SEEDING.
C) REVISE THE REGULATIONS IN EROSION AND SEDIMENT
CONTROL NOTE 1 TO THE CURRENT REGULATIONS (9VAC
25-840-40).
D) INCLUDE INSTALLATION OF INLET PROTECTION IN THE
PHASE 2 SEQUENCING.
11. SHEET 15:
A) INCLUDE SHEET REFERENCE FOR THE REMOVABLE BOLLARD
DETAIL IN THE CALLOUT.
B) IN THE PRINCIPAL SPILLWAY DETAIL, INCLUDE THE TRASH
RACK FOR THE 3" ORIFICE AND PROVIDE DETAIL INCLUDIN
ANCHORING.
C) THE 155 LABEL BETWEEN THE TWO OFFSET DIMENSION TO
THE WEST OF THE SWM FACILITY APPEARS TO BE FOR A 15
CONTOUR. CLARIFY
D) PROVIDE GRAVEL FOR THE ACCESS TO THE BOTTOM OF THE
SWM FACILITY.
E) PROVIDE VEHICLE SAFETY ALONG WARE BOTTOM SPRING ROA
FOR SWM FACILITY.
F) 100-YEAR ELEVATION IN PLAN VIEW DIFFERS FROM PROFIL
VIEW. VERIFY ELEVATION.
G) SHOW THE 149 CONTOUR IN THE BOTTOM OF BASIN AND
PROVIDE SPOT SHOTS SHOWING THE 1% BOTTOM SLOPE.
12. CALCULATIONS:
A) IN THE VRRM CALCULATIONS, SINCE THE SOILS ARE A
COMPLEX OF HSG A AND B SOILS, TREAT THE SITE AS A B
SOIL FOR WORST CASE SCENARIO.
B) IN THE STORM SEWER DESIGN CALCULATIONS AND IN THE
HGL CALCULATIONS, THE LENGTHS AND INVERT OUT FOR
PIPE 2-1 DOES NOT MATCH THE PLANS. VERIFY PIPE
GEOMETRY.
C) IT IS SUGGESTED 0.10' DROPS BE PROVIDED AT
STRUCTURES BETWEEN INCOMING AND OUTGOING PIPES.
D) THE TO STRUCTURES FOR STRUCTURES 3 AND 4 IN THE
CALCULATIONS APPEARS TO BE IN ERROR. VERIFY TO
STRUCTURES.
E) INDICATE THE FLOW FROM POINT 3 IS A ROUTED FLOW FRO
THE POND.
F) PROVIDE THE ROUTINGS FOR ALL STORM EVENTS.
G) IT APPEARS THE DRAINAGE AREA INFORMATION FOR
DRAINAGE AREA A1 AND A2 ARE OPPOSITE FROM THE PLANS
TO THE CALCULATIONS. VERIFY CALCULATIONS AND PLANS
13. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
14. PERMISSION MUST BE OBTAINED FROM THE ADJACENT PROPERTY
OWNER(S) ALLOWING FOR GRADING ON THE PROPERTY AS
PROPOSED PRIOR TO ISSUANCE OF A LAND DISTURBANCE
PERMIT.
15. ALL ONSITE DRAINAGE EASEMENTS INCLUDING STORMWATER /
BMP DRAINAGE EASEMENTS MUST BE RECORDED PRIOR TO
ISSUANCE OF A BUILDING PERMIT FOR THIS PROJECT.
16. AS-BUILT BMP INFORMATION WILL BE REQUIRED FOR EACH
BMP FACILITY AS PART OF ITS FUTURE CERTIFICATION.
17. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
SURETY FOR THE CONSTRUCTION OF THE PERMANENT BMP MUST
BE POSTED WITH ENVIRONMENTAL ENGINEERING. (COUNTY CODE
PART II, CHAPTER 8, SEC. 8-16)
18. THE BMP MUST BE CERTIFIED PRIOR TO RELEASE OF THE BMP
PERFORMANCE BOND.
19. THE RISER AND BARREL PIPE ASSOCIATED WITH THE SEDIMENT
BASIN MUST BE ON-SITE PRIOR TO ISSUANCE OF A LAND
DISTURBANCE PERMIT.
20. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
21. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
22. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. THE VIRGINIA STORMWATER MANAGEMENT PERMIT (VSMP)
REGISTRATION STATEMENT AND FEE OF $2,700
D. THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) BOOK
E. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================