All Site Plan Review Comments for Case # 16PR0250
Modify comments view for Case # 16PR0250

Go to Case Selection Form or Go to Project List

 
CASE NO: 16PR0250 STATUS: APPROVED - ADMIN
PROJECT NAME: GREENWICH WALK @ FOX - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: MULTI-FAMILY
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 02 05/23/17 06/14/17 ******** ********
ENVIR.ENGR.-: 02 05/23/17 06/14/17 ******** 06/20/16 CBH 776-7836
FIRE DEPT.--: 02 05/23/17 06/14/17 COMPLETE 05/26/17 AWB 717-6167
MAPPING/GIS-: 02 05/23/17 06/14/17 COMPLETE 06/12/17 AMJ 768-7549
PLANNING----: 02 05/23/17 06/14/17 COMPLETE 06/20/17 JJD 717-6191
TRANSPORT.--: 02 05/23/17 06/14/17 COMPLETE 05/31/17 SJA 751-4461
UTIL.PLAN.--: 02 05/23/17 06/14/17 ******** ********
UTILITIES---: 02 05/23/17 06/14/17 AMENDED* 06/05/17 M L 748-1338
UTIL.R.O.W.-: 02 05/23/17 06/14/17 ******** ********
VDOT--------: 02 05/23/17 06/14/17 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E./748-1338
NAME OF PLAN : GREENWICH WALK AT FOX CREEK PH 3
ADDRESS : 7311 OTTERDALE RD
SUBMISSION DATE : 5/11/16
PLAN DATED : 5/9/16
REVIEW DATE : 5/20/16
SITE PLAN NO. : 16PR0250
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW : NO
PLAT PROCESS :
1. UTILITIES PROJECT NUMBER 16-0119 SHALL BE PLACED ON
THE LOWER RIGHT HAND CORNER OF EACH SHEET.
2. PLEASE PUT UTILITIES CONTACT MIKE LARSON, P.E. 748-
1338, LARSONM@CHESTERFIELD.GOV ON THE COVER SHEET.
3. PLEASE INDICATE THAT ALL WATER AND SEWER ITEMS ARE
PUBLIC ON THE COVER SHEET
4. INCLUDE MANHOLE INSERTS IN THE MATERIALS LIST FOR EACH
MANHOLE.
5. ON SHEET C3.1 FOR THE WATER SERVICE CONNECTIONS, THE
CONNECTIONS SHOULD BE DESIGNATED AS 3/4 INCH INSTEAD OF 5/
INCH, WHICH IS THE SIZE OF THE METER.
6. ON BUILDING 95, PLEASE PUT A NOTE IN PARENTHESES THAT
SAYS "SEWER LATERAL PHASE 1".
7. AS DISCUSSED, PLEASE MOVE THE WATERLINE OUT FROM UNDER
THE SET OF 4 CULVERTS NEAR THE INTERSECTION OF NEWHAM
CROSSING AND WELARA RUN. THE DEFLECTION AROUND THE BENDS
WILL NEED RESTRAINED JOINTS AND PERMANENT EASEMENT. THE
WATERLINE AS SHOWN IS NOT ACCESSIBLE IN THE EVENT OF A
BREAK. ADDITIONALLY, BOTH THE WATER AND SEWER WILL NEED T
BE IN AN EASEMENT SINCE THIS SECTION OF ROAD WILL NOT
IMMEDIATELY BE ACCEPTED INTO THE PUBLIC SYSTEM.
8. ON SHEET C4.0, SHOW THE EXTENT OF WETLAND CROSSING IN
THE PROFILE AND SHOW A CLAY DAM PER DETAIL SEW-9 ON BOTH
SIDES OF THE SEWER CROSSING. THIS DETAIL SHOULD BE
INCLUDED IN THE PLAN SET.
9. FOR THE AIR RELEASE VALVE AT STA 19+40 ON WELARA RUN,
PROVIDE A NOTE ON THE PROFILE TO MAINTAIN A POSITIVE GRADE
ON THE AIR LINE.
10. BASED ON EXAMINATION OF THE PLANS, IT APPEARS THAT MH
24 COULD BE INSTALLED A FEW FEET SHALLOWER THUS INCREASING
THE SLOPE ON HALLOWELL RIDGE AND DECREASING THE DEPTH OF
THE SEWER. PLEASE EVALUATE HOW THIS IMPACTS THE SEWER
DESIGNED IN PHASE 1 AND PHASE 2. IT WOULD BE DESIRABLE TO
AVOID UNNECESSARILY DEEP SEWER IN THOSE PHASES FOR LONG
TERM OPERATIONS AND SHALLOWER SEWER WILL REDUCE
CONSTRUCTION COST.
11. THE MANHOLE TOP SHOWN FOR MH E5 DOES NOT AGREE WITH
THE TOP SHOWN ON THE APPROVED PHASE 1 PLANS. PLEASE CHECK
THE GRADING TO ENSURE THAT THE PROPER ELEVATIONS ARE BEING
USED FOR THE PROFILES.
12. PLEASE BE ADVISED THAT THIS PROJECT WILL NOT BE
ACCEPTED INTO USE BY THE COUNTY UNTIL THE PHASE 1 WATER AN
SEWER ARE COMPLETE
13. THE OWNER SHALL BE REQUIRED TO ENTER INTO A COUNTY
UTILITIES CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PRIOR TO THE PREPARATION OF THE UTILITIES CONTRACT,
UTILITIES MUST BE IN RECEIPT OF THE "ACCEPTED" BID PROPOSA
BETWEEN THE DEVELOPER AND THE COUNTY APPROVED UTILITIES
CONTRACTOR AS WELL AS THE PROJECT'S INFORMATIONAL SHEET
FOUND ON THE "DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TW
ITEMS TO THE ATTENTION OF MIKE LARSON
(LARSONM@CHESTERFIELD.GOV). THE BID PROPOSAL MUST BE BASED
ON THE APPROVED SITE PLAN. BE ADVISED THAT IF THE SITE PLA
IS REVISED AND REAPPROVED SUBSEQUENT TO THE PREPARATION OR
RECORDATION OF THE UTILITIES CONTRACT, THE BID PROPOSAL
SHALL BE REVISED ACCORDINGLY AND A REVISED UTILITIES
CONTRACT MAY BE NECESSARY.
14. AFTER FINAL SITE PLAN APPROVAL, SUBMIT THREE SETS OF
THE APPROVED PLANS DIRECTLY TO THE UTILITIES DEPARTMENT FO
OUR USE DURING CONSTRUCTION INSPECTION. THIS IS IN
ADDITION TO THE ONE APPROVED SET FROM PLANNING (4 TOTAL
SETS).
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E./748-1338
NAME OF PLAN : GREENWICH WALK AT FOX CREEK PH 3
ADDRESS : 7311 OTTERDALE RD
SUBMISSION DATE : 2/28/17
PLAN DATED : 2/20/17
REVIEW DATE : 3/10/17
SITE PLAN NO. : 16PR0250
COMMENTS : 2ND REVIEW-NOT APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
.
1. CORRECT THE WATER METER FOR LOT 161 SO THAT IT IS INSTA
ED PERPENDICULAR TO THE MAIN. PER MY EMAIL TO MATT FARIS
MARCH 9, 2017, SHEET C3.1 ON THE PHASE 2 PLANS SHOULD SHO
THIS CORRECTION SO IT IS ADDRESSED IN THE FIELD.
.
2. WE WILL NEED TO HAVE A LICENSE AGREEMENT FOR THE PUBLI
LATERALS THAT MUST BE INSTALLED UNDER THE CONCRETE DRIVEWA
APRON. SINCE THE FIRE HYDRANTS CANNOT REASONABLY BE INSTAL
D BEHIND THE CURB AT THIS LOCATION WE WOULD LIKE THE LICEN
TO INCLUDE THOSE AS WELL. PLEASE CONTACT JOAN
COARSON AT 804-748-1362 TO START THE PROCESS.
.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : MIKE LARSON, P.E./748-1338
NAME OF PLAN : GREENWICH WALK AT FOX CREEK PH 3
ADDRESS : 7311 OTTERDALE RD
SUBMISSION DATE : 5/23/17
PLAN DATED : 4/26/17
REVIEW DATE : 6/5/17
SITE PLAN NO. : 16PR0250
COMMENTS : 3RD REVIEW- APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
SUBMIT 3 COPIES OF PLANS FOR USE DURING CONSTRUCTION ONCE
PPROVALS FROM ALL OTHER DEPARTMENTS ARE OBTAINED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
EMAIL: ADAMSST@CHESTERFIELD.GOV
NAME OF PLAN: GREENWICH WALK AT FOX CREEK PHASE 3
SITE PLAN NUMBER: 16PR0250
LATEST PLAN DATE: 05/09/16
DEPT. REC'D. DATE: 05/13/16
SUBMITTAL NUMBER: ONE
REVIEW DATE: 05/18/16
RECOMMENDATION: APPROVED
FINAL SITE PLAN APPROVAL IS PENDING RIGHT-OF-WAY DEDICATIO
FOR THE PROPOSED STATE MAINTAINED ROADS AS SHOWN ON THE
PLAN.
PRIOR TO ISSUANCE OF BULDING PERMITS FOR A CUMULATIVE TOTA
OF MORE THAN 100 LOTS/UNITS FOR GREENWICH WALK AT FOX CREE
DEVELOPMENT (PHASES 1, 2, 3), TWO (2) LANES OF VILLAGE
SQUARE PARKWAY SHALL BE COMPLETED PER SITE PLAN CASES
08PR0289 AND 08PR0290 (PER APPROVED TRANSPORTATION PHASING
PLAN DATED 10/28/15).
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: GREENWICH WALK AT FOX CREEK PHASE 3
SITE PLAN NUMBER: 16PR0250
LATEST PLAN DATE: 02/20/17
DEPT. REC'D. DATE: 03/02/17
SUBMITTAL NUMBER: TWO
REVIEW DATE: 03/09/17
RECOMMENDATION: SUBSTANTIAL APPROVAL
PLAT PROCESSING: R/W DEDICATION - LOCAL ROADS
.
FINAL SITE PLAN APPROVAL IS PENDING RIGHT-OF-WAY DEDICATIO
FOR THE PROPOSED STATE MAINTAINED ROADS AS SHOWN ON THE
PLAN.
.
IT APPEARS THIS PHASE WILL TRIGGER THE REQUIREMENT TO
COMPLETE VILLAGE SQUARE PKY. FOLLOWING SHOULD BE NOTED IN
THE APPROVAL LETTER BY PLANNING:
.
PRIOR TO ISSUANCE OF BULDING PERMITS FOR A CUMULATIVE TOTA
OF MORE THAN 100 LOTS/UNITS FOR GREENWICH WALK (PHASES 1,
2, 3), TWO (2) LANES OF VILLAGE SQUARE PKY SHALL BE
COMPLETED PER SITE PLAN CASES 08PR0289 AND 08PR0290
(APPROVED TRANSPORTATION PHASING PLAN DATED 10/28/15).
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: GREENWICH WALK AT FOX CREEK PHASE 3
SITE PLAN NUMBER: 16PR0250
LATEST PLAN DATE: 04/26/17
DEPT. REC'D. DATE: 05/25/17
SUBMITTAL NUMBER: THREE (JJD)
REVIEW DATE: 05/31/17
RECOMMENDATION: APPROVED
PLAT PROCESSING: R/W DEDICATION - LOCAL ROADS
.
THIS PHASE WILL TRIGGER THE REQUIREMENT TO COMPLETE VILLAG
SQUARE PKY (SITE PLAN CASE 08PR0289 & 08PR0290). FOLLOWING
SHOULD BE NOTED IN THE APPROVAL LETTER BY PLANNING:
.
PRIOR TO ISSUANCE OF BULDING PERMITS FOR A CUMULATIVE TOTA
OF MORE THAN 100 UNITS FOR GREENWICH WALK (PHASES 1, 2, 3)
TWO (2) LANES OF VILLAGE SQUARE PKY SHALL BE COMPLETED PER
SITE PLAN 08PR0289 & 08PR0290 (TRANSPORTATION PHASING PLAN
DATED 10/28/15).
==========================================================
==========================================================
REVIEWER / PHONE #-JEFF DOPP/717-6191
EMAIL--------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN - GREENWICH WALK AT FOX CREEK PHASE 3
SITE PLAN NUMBER---16PR0250
1ST SUBMITTAL PLAN DATE-05/10/16
2ND SUBMITTAL PLAN DATE- 02/20/2017
DEPT. REC'D. DATE---02/27/2017
ACCEPTED FOR REVIEW - 02/28/2017
SUBMITTAL NUMBER-------TWO
REVIEW DATE------------ 03/27/2017
RECOMMENDATION----NOT APPROVED
TABLE REVIEW-----------NO
LANDSCAPE PLAN STATUS- NOT APPROVED
LIGHTING PLAN/CUTSHEETS---REQUESTED SEE COMMENTS
IRRIGATION/HOSEBIB PLAN---REQUESTED SEE COMMENTS
REVIEW COMMENTS:
01. PUT A REVISION DATE ON THE RESUBMITTED
PLANS. RESUBMIT 12 FULL SETS & 1 COPY OF
THE SITE PLAN SHEET TO THE PLANNING
DEPARTMENT FOR YOUR NEXT REVIEW.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS
USING THE SPACE BELOW EACH COMMENT TO
DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED.
PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT
CAUSED BY STAFF REVIEW COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM #)
03. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER
16PR0250 IN THE LOWER RIGHT CORNER OF EACH SHEET.
04. ON ALL SHEETS SHOW BOTH HORIZONTAL SCALE ON
EACH SHEET INCLUDING A GRAPHIC SCALE.
05. ON LAYOUT AND UTILITY PLAN, EROSION & SEDIMENT
CONTROL AND GRADING PLANS DIMENSION AND LABEL 50'
SETBACK AND LABEL "50' SETBACK W/PERIMETER
LANDSCAPING C.
06. SHEET C3.1: RELOCATE THE "WATER SERVICE AND
CONNECTION "NOTES SHOWN ON THE SITE LAYOUT SO THE
50' SETBACK BOUNDARIES IS CLEAR. SITE LAYOUT NEEDS
TO BE REVISED TO SHOW PROPERTY LINE AND 50' SETBACK
W/PERIMETER LANDSCAPING C.
06. SHEET C3.1: RELOCATE THE "WATER SERVICE AND
CONNECTION "NOTES SHOWN ON THE SITE LAYOUT SO THE
50' SETBACK BOUNDARIES IS CLEAR. SITE LAYOUT NEEDS
TO BE REVISED TO SHOW PROPERTY LINE AND 50' SETBACK
W/PERIMETER LANDSCAPING C.
07. SHEETS C2.0, C3., C3., C3.5: EXTEND AND SHOW
SIDEWALK AND CONCRETE MARKINGS FOR THE PORTION OF
THE SIDEWALK LOCATED ADJACENT TO UNIT 95 AND NEWHAM
CROSSING. THIS PORTION WAS NOT PART OF PHASE 2.
08. SHEET C3.2 C3., C5.0, C5.1: EXTEND AND SHOW
SIDEWALK AND CONCRETE MARKINGS FOR THE PORTION OF THE
SIDEWALK LOCATED ON THE NORTH EAST SIDE OF HALLOWELL RIDGE
SIDEWALK NEEDS TO EXTEND THE FULL LENGTH OF PHASE
THREE AND CONNECT INTO PHASE 4.
09. SHEETS C3.5 C5.0, C5.1TIGHTEN GRADING AREA EAST OF
UNIT 173 TODECREASE SLOPE OF SIDEWALK.
10. SHEET L1.1: PER THE APPROVED TEXTUAL STATEMENT,
STREET TREES REQUIRED TO BE PLANTED OR RETAINED ON BOTH
SIDES OF ALL STREETS. PLEASE ADD STREET TREES ON THE NORTH
SIDE OF HALLOWELL RIDGE AND REVISE PLANTING SCHEDULE
TO REFLECT THESE PLANTINGS.
11. FOR THE 50' SETBACK PROVIDE A DETAILED LANDSCAPE
PLAN SHOWING AND MEETING ALL THE REQUIREMENTS OF
PERIMETER LANDSCAPING C. LANDSCAPE PLAN NEEDS TO
INCLUDE ENTIRE LENGTH OF 50' SETBACK SHOWN FOR PHASE
THREE.
12. TEXTUAL STATEMENT C.2. OF CASE 12SN0226
REQUIRES SUPPLEMENTAL TREES FOR DETACHED UNITS.
PLEASE SHOW AND IDENTIFY ON LANDSCAPE PLANS THE
REQUIRED SUPPLEMENTAL TREES FOR ALL DETACHED
BUILDINGS. FOR EACH DWELLING UNIT, A MINIMUM
OF ONE (1) FLOWERING TREE IN EACH YARD SHALL BE
PLANTED IN EACH FRONT YARD. FLOWERING TREES
SHALL HAVE A MINIMUM CALIPER OF 2" MEASURED AT
BREAST HEIGHT (4'-10" ABOVE GROUND) AT THE TIME
OF PLANTING.
13. SUBMIT A DETAILED LANDSCAPE PLAN THAT MEETS
THE REQUIREMENTS OF TEXTUAL STATEMENT C.4. FOR
DETACHED UNITS. THE CONDITION READS: FRONT
FOUNDATION PLANTING BED: FOUNDATION
PLANTING IS REQUIRED ALONG THE ENTIRE FRONT FAçADE
OF ALL UNITS, AND SHALL EXTEND ALONG ALL SIDES FACING
A STREET. FOUNDATION PLANTING BEDS SHALL BE A
MINIMUM OF 4' WIDE FROM THE UNIT FOUNDATION.
PLANTING BEDS SHALL BE DEFINED WITH A TRENCHED
EDGE OR SUITABLE LANDSCAPE EDGING MATERIAL.
PLANTING BEDS SHALL INCLUDE MEDIUM SHRUBS SPACED
A MAXIMUM OF FOUR (4) FEET APART. UNIT CORNERS
SHALL BE VISUALLY SOFTENED WITH VERTICAL ACCENT
SHRUBS (4'-5') OR SMALL EVERGREEN TREES (6'-8')
AT THE TIME OF PLANTING.
14. ON THE LANDSCAPE PLAN ADD THE FOLLOWING NOTE:
"SODDED YARD AREAS: ALL CONTIGUOUS YARD AREAS
ALONG ATTACHED BUILDING FRONTS AND ALL SIDE YARDS THAT
FACE A STREET SHALL BE SODDED AND IRRIGATED." (REF. TEXTUA
STATEMENT B.3. OF CASE 12SN0226.
15. ON THE LANDSCAPE PLAN ADD THE FOLLOWING NOTE:
"FRONT YARD AREA: EXCEPT FOR THE FOUNDATION
PLANTING BED, ALL FRONT YARDS SHALL BE SODDED AND IRRIGATE
FOR DETACHED UNITS."
16. PER GREG ALLEN'S EMAIL DATED NOVEMBER 4, 2015,
THE IRRIGATION PLAN MAY BE SUBMITTED AT TIME OF
BUILDING PERMIT SUBMITTAL FOR EACH PHASE. PLEASE
ENSURE THE IRRIGATION PLAN IS DESIGNED TO MEET
BOTH ORDINANCE REQUIREMENTS AND THE TEXTUAL
STATEMENT DATED NOVEMBER 15, 2013 APPROVED
UNDER CASE 12SN0226) REQUIRING ALL FRONT YARDS
TO BE SODDED AND IRRIGATED. INSURE WATER INFORMATION
IS SUPPLIED ON UTILITY DEPARTMENT METER SIZING FORMS.
17. PER ENVIRONMENTAL ENGINEERING:
LARGE TREES SHALL NOT BE PLANTED ANY CLOSER THAN
8 FEET FROM STORM SEWER STRUCTURES AND PIPES.
PLEASE MAKE ANY NECESSARY ADJUSTMENTS TO THE
LANDSCAPE PLAN TO ENSURE THIS REQUIREMENT IS MET.
18. SHEET C1.1: WITHIN THE 50' SETBACK ADJACENT TO THE
EXISTING FOX CREEK SUBDIVISION SHOWN ON EXHIBIT A
OF CASE 12SN0226, LABEL "PERIMETER LANDSCAPE C"
ON PLANS.
19. PRIOR TO FINAL SITE PLAN APPROVAL, SUBMIT TWO COPIES O
LANDSCAPE PLANS TO THE PLANNING DEPARTMENT IN ACCORDANCE W
CONDITIONS OF CASE 12SN0226 AND THE COUNTY ORDINANCE.
(REF. COUNTY ORDINANCE AND TEXTUAL STATEMENT DATED
NOVEMBER 15, 2013 APPROVED UNDER CASE 12SN0226).
SHOW ALL SITE IMPROVEMENTS INCLUDING UTILITIES, STORM SEWE
EASEMENTS AND RIGHTS-OF-WAY, FIRE HYDRANT AND VAULT LOCATI
AND SITE LIGHTING (IF SITE IS TO BE LIT). THIS PLAN MUST B
TO SCALE. THE PLAN MUST INCLUDE DIMENSIONS OF PERIMETER
YARDS AND BUFFERS AND APPROPRIATE LANDSCAPE REQUIREMENTS F
EACH YARD OR BUFFER, BMP AREAS AND ANY OTHER LANDSCAPE
REQUIREMENTS. THE PLAN MUST SHOW THE LAYOUT OF EXISTING AN
PROPOSED TREES AND SHRUBS WITH THE PLAN SIZES, SPECIFIC PL
SPECIES, COUNTY REQUIRED NOTES AND DETAILS AND ANY SPECIFI
REQUIREMENTS FOR THE SITE. (CL D.4)
20. PER THE DIRECTION OF KIRK TURNER, THE RESIDENTIAL
MIXED USE PLAN SHOWING ALL UNITS FOR THE OVERALL
PROJECT KEYED TO ELEVATIONS WILL NOT BE NECESSARY.
THE RESIDENTIAL MIXED USE PLAN NEED ONLY
SHOW UNITS UNDER REVIEW FOR EACH PHASE WITH
AN UNDERSTANDING THAT ALL ARCHITECTURAL
REQUIREMENTS OUTLINED IN THE TEXTUAL STATEMENT
DATED NOVEMBER 15. 2013 SHALL BE MET. FOR
THIS PHASE SUBMIT A RESIDENTIAL MIXED USE PLAN
FOR UNITS 63 THROUGH 93. BECAUSE THE PROJECT
IS BEING SUBMITTED IN PHASES, KEEP IN MIND THE
TEXTUAL STATEMENT REQUIRES THAT DETACHED UNITS
WITH THE SAME ELEVATIONS MAY NOT BE LOCATED
ADJACENT TO, DIRECTLY ACROSS FROM, OR DIAGONALLY
ACROSS FROM EACH OTHER ON THE SAME STREET. THIS
REQUIREMENT DOES NOT APPLY TO UNITS ON DIFFERENT
STREETS BACKING UP TO EACH OTHER. REFERENCE
GENERAL CONDITION I. A. OF THE TEXTUAL STATEMENT
DATED NOVEMBER 15, 2013, APPROVED WITH ZONING
CASE 12SN0226.
21. SITE PLAN APPROVAL IS CONTINGENT UPON APPROVAL
OF ARCHITECTURAL ELEVATIONS.
22. FOR EACH UNIT OR PRODUCT, PROVIDE 2 COPIES OF
FOUR SIDED ARCHITECTURAL ELEVATIONS OF THE BUILDINGS
WITH ALL BUILDING MATERIALS AND COLORS IDENTIFIED,
LOCATIONS OF JUNCTION AND ACCESS BOXES SHOWN, AND
HOW ALL MECHANICAL EQUIPMENT IS SCREENED WHETHER
IT IS MOUNTED ON THE ROOF OR ON THE GROUND .
ARCHITECTURAL ELEVATIONS SHALL COMPLY WITH ALL
REQUIREMENTS OF THE APPROVED TEXTUAL STATEMENT.
DATED NOVEMBER 15, 2013. APPROVED UNDER
CASE 12SN0226). (SEC. 19-264(D) (18)
23. PLEASE BE AWARE BOTH PASSIVE AND RECREATIONAL AMENITIE
ARE REQUIRED PER CONDITION 3. A, B, C, D & E OF ZONING CAS
12SN0226.
24. CASH PROFFERS ARE REQUIRED PER CONDITION 4 OF ZONING
CASE 12SN0226.
25.. THE SITE PLAN DOES NOT ADDRESS CONDITION 5. OF ZONING
CASE12SN0226 REGARDING AGE RESTRICTION. REVISE PLANS
BY ADDING THE FOLLOWING REQUIRED NOTE: AGE RESTRICTION.
EXCEPT AS OTHERWISE PROHIBITED BY THE VIRGINIA FAIR
HOUSING LAW, THE FEDERAL FAIR HOUSING ACT, AND SUCH
OTHER APPLICABLE FEDERAL, STATE OR LOCAL LEGAL REQUIREMENT
ALL DWELLING UNITS SHALL BE RESTRICTED TO"HOUSING FOR OLDE
PERSONS" AS DEFINED IN THE VIRGINIA FAIR HOUSING LAW
AND NO PERSONS UNDER 19 YEARS OF AGE SHALL RESIDE
THEREIN."
26. SUBMIT DOCUMENTS DEMONSTRATING COMPLIANCE WITH
CONDITION 7 OF CASE 12SN0226 PERTAINING TO THE VIRGINIA
CONDOMINIUM ACT AND THE CONDOMINIUM ASSOCIATION
RESPONSIBILITIES OF MAINTENANCE OF ALL COMMON AREAS,
ARCHITECTURAL REVIEW COMMITTEE. THE CONDOMINIUM
ASSOCIATION SHALL BE PART OF THE FOXCREEK HOMEOWNER'S
ASSOCIATION. ALSO, ENSURE HOA DOCUMENTS MEET ALL
REQUIREMENTS OF ORDINANCE SEC. 19-559.
27. PRIOR TO RECEIVING A TEMPORARY OCCUPANCY PERMIT,
A FORM OF SURETY (BOND OR LETTER OF CREDIT) IN AN
AMOUNT EQUAL TO THE COST OF COMPLETING THE
REQUIRED LANDSCAPING SHALL BE PROVIDED TO THE
PLANNING DEPARTMENT. THE SURETY SHALL ALSO COVER
AN AMOUNT EQUAL TO 50% OF THE TOTAL INSTALLATION
COST FOR REPLACEMENT OF ALL UNHEALTHY OR DEAD PLANTS
OR POLLARDED TREES IDENTIFIED BY THE ONE-YEAR INSPECTION
BY PLANNING DEPARTMENT. REFERENCE SECTION 19-518 (F)
28. PER GREG ALLEN'S EMAIL DATED NOVEMBER 4, 2015
THE IRRIGATION PLAN MAY BE SUBMITTED AT TIME OF
BUILDING PERMIT SUBMITTAL FOR EACH PHASE. PLEASE
ENSURE THE IRRIGATION PLAN IS DESIGNED TO MEET
BOTH ORDINANCE REQUIREMENTS AND THE TEXTUAL
STATEMENT DATED NOVEMBER 15, 2013 APPROVED
UNDER CASE 12SN0226) REQUIRING ALL FRONT YARDS
TO BE SODDED AND IRRIGATED. INSURE WATER INFORMATION
IS SUPPLIED ON UTILITY DEPARTMENT METER SIZING FORMS.
29. SUBMIT TWO COPIES OF AN IRRIGATION PLAN COMPLYING
WITH COUNTY ORDINANCE REQUIREMENTS AND TEXTUAL
STATEMENT REQUIREMENTS. PER SEC. 19-518(E), ALL
LANDSCAPED AREAS SHALL BE PROVIDED WITH A READILY
AVAILABLE WATER SUPPLY. THE COUNTY ACCEPTS EITHER
YARD HYDRANTS AND/OR HOSE BIBS WITHIN 100 FEET OF
ALL NEW PLANTINGS OR AN IRRIGATION SYSTEM FOR ALL AREAS
OF NEW PLANTINGS. (REF. COUNTY ORDINANCE AND TEXTUAL
STATEMENT DATED NOVEMBER 15, 2013 APPROVED UNDER
CASE 12SN0226).THE APPROVED TEXTUAL STATEMENT
REQUIRES SODDED YARD AREAS TO BE IRRIGATED. PLEASE
SHOW THIS BEING ACCOMPLISHED ON IRRIGATION PLAN.
(REF. COUNTY ORDINANCE AND TEXTUAL STATEMENT DATED
NOVEMBER 15, 2013 APPROVED UNDER CASE 12SN0226).
30. PER REVIEWERS EMAIL CORRESPONDENCE WITH
ENGINEER DATED 4/15/15, MANUFACTURER CUT
SHEETS FOR BUILDING MOUNTED LIGHTS ATTACHED TO
DWELLING UNITS WILL NOT BE REQUIRED UNTIL TIME
OF BUILDING PERMIT. HOWEVER, IN CONJUNCTION
WITH SITE PLAN APPROVAL, MANUFACTURER CUT SHEETS
AND A LIGHTING PLAN ARE REQUIRED FOR PROPOSED
STREET LIGHTS AND YARD LIGHTS. PER SEC. 19-508.3,
SHOW ON THE LANDSCAPE PLAN OR ADDITIONALLY ON
A SEPARATE LIGHTING PLAN THE LOCATION OF ALL EXTERIOR
SITE LIGHTING MOUNTED ON POLES, OR ON THE GROUND
AND HAVE THEM KEYED TO CUT SHEETS FOR EACH LIGHT
FIXTURE SHOWN ON THE PLAN.
31. INDICATE PROPOSED SITE AREA LIGHTING ON THE
LANDSCAPE PLAN. PROPOSE LANDSCAPING AND LIGHTING
LOCATIONS SHALL BE COORDINATED TO PREVENT PLANT
MATERIAL AT MATURE SIZES FROM INTERFERING WITH
LIGHT FIXTURES. (REF SEC 19-571 (B)
32. PROVIDE CATALOGUE CUT SHEETS FOR EACH EXTERIOR
LIGHT FIXTURE PROPOSED.
33. ANY CHANGE IN THE CURRENT PLAN, WHETHER IT STEMS FROM
DEPARTMENT COMMENTS OR AN ENGINEERING CHANGE REQUESTED
BY THE APPLICANT, MAY GENERATE ADDITIONAL COMMENTS FROM
THE REVIEWING DEPARTMENTS, RESULTING IN REQUIRED REVISIONS
##########################################################
##########################################################
#
EMAIL--------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN - GREENWICH WALK AT FOX CREEK PHASE 3
SITE PLAN NUMBER---16PR0250
1ST SUBMITTAL PLAN DATE-05/10/16
2ND SUBMITTAL PLAN DATE- 02/20/2017
DEPT. REC'D. DATE---02/27/2017
ACCEPTED FOR REVIEW - 02/28/2017
SUBMITTAL NUMBER-------TWO
REVIEW DATE------------ 03/27/2017
RECOMMENDATION----NOT APPROVED
TABLE REVIEW-----------NO
LANDSCAPE PLAN STATUS- NOT APPROVED
ARCHITECTURAL ELEVATIONS- REQUIRED
TO BE SUBMITTED & APPROVED PRIOR TO BUILDING
PERMIT SUBMITTAL.
LIGHTING PLAN/CUTSHEETS- RESPONSE
FROM DEVELOPER-NONE PROPOSED
IRRIGATION/HOSEBIB PLAN-COVERAGE PLAN
REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL.
.
SECOND REVIEW COMMENTS:
.
01. PUT A REVISION DATE ON THE RESUBMITTED
PLANS. RESUBMIT 12 FULL SETS & 1 COPY OF
THE SITE PLAN SHEET TO THE PLANNING
DEPARTMENT FOR YOUR NEXT REVIEW.
.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS
USING THE SPACE BELOW EACH COMMENT TO
DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED.
.
03. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT
CAUSED BY STAFF REVIEW COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM #)
.
04. PLEASE COORDINATE WITH BUILDERS TO ENSURE
DWELLING UNITS WILL FIT WITHIN THE BUILDING
FOOTPRINTS SHOWN ON THE SITE PLAN. ANY CHANGES
TO THE PLANS AFTER SITE PLAN APPROVAL WILL REQUIRE AN
ADJUSTMENT TO AN APPROVED SITE PLAN REQUIRING A
$700.00 REVIEW FEE FOR EACH SUBMITTAL.
.
05. SHEET C3.2: UPPER RIGHT CORNER OF SHEET IS
COVERED WITH NOTES. REVISE TO SHOW
ENTIRE BOUNDARY OF PHASE 3 AND LABEL AND
DIMENSION THE 50' BUFFER WITH 1.5 C LANDSCAPING
ALONG THE NORTH BOUNDARY OF THE PROJECT. ALSO,
LABEL METES AND BOUNDS OF BOUNDARY LINES.
PLEASE DO NOT COVER SITE LAYOUT BOUNDARIES WITH
BLOCKS OF NOTES.
.
06. THE NORTH PROPERTY LINE ADJACENT TO THE
PRIMROSE SECTION 2 SUBDIVISION REQUIRES A
50' BUFFER WITH 1.5 X PERIMETER LANDSCAPE C.
ON ALL SITE LAYOUT SHEETS, LANDSCAPE SHEETS,
GRADING AND EROSION CONTROL SHEETS LABEL AS
"50' BUFFER W/1.5 X PERIMETER LANDSCAPE C".
WITHIN THIS BUFFER LABEL "BUFFER
TO BE LEFT UNDISTURBED".
.
07. REVISE LANDSCAPE PLAN TO MEET THE PLANTING
REQUIREMENTS TO COMPLY WITH 1.5 X PERIMETER
C LANDSCAPING. IF THERE ARE HEALTHY EXISTING
EVERGREENS, LARGE & SMALL DECIDUOUS TREES
WITHIN THE 50' BUFFER, THESE PLANTINGS MAY BE
CREDITED TOWARD LANDSCAPING REQUIREMENTS
PROVIDED THEY REASONABLY DISTRIBUTED THROUGHOUT
THE BUFFER. IF YOU ARE GOING TO CREDIT EXISTING
PLANTINGS SHOW LOCATION ON LANDSCAPE PLANS
AND KEY TO PLANT SCHEDULE.
.
08. SHEETS L1.0, L1.1, L1.2 & C3.4: ON BOTH THE
GRADING AND LANDSCAPE PLANS IDENTIFY THE MAXIMUM
SIDE SLOPE WITHIN THE 50' SETBACK ADJACENT TO FOX
CREEK SUBDIVISION. THE MAXIMUM SIDE
SLOPE ALLOWED PER THE ORDINANCE FOR REQUIRED
PLANTINGS ARE A 3:1 SLOPE.
.
09. THE PROPOSED COMPACT BURNING BUSH IS IDENTIFIED
ON THE COUNTY PLANT MATERIAL LIST AS INVASIVE.
PLEASE SELECT AN ACCEPTABLE NON-INVASIVE MEDIUM
BUSH FROM THE LIST. IF IRRIGATION WILL NOT BE
INSTALLED, ENSURE PERIMETER PLANTING IS DROUGHT TOLERANT.
.
10. UNLIKE THE POD PLANS, THE PERIMETER LANDSCAPING
IRRIGATION IS NOT ASSOCIATED WITH A BUILDING PERMIT AND
CANNOT BE TIED TO A C/O TO ENSURE INSTALLATION HAS BEEN
ACCOMPLISHED. THE METHOD OF IRRIGATION FOR THE
PERIMETER LANDSCAPING IS REQUIRED TO BE APPROVED AS
PART OF THE SITE PLAN APPROVAL. THERE ARE DIFFERENT
OPTIONS YOUR CLIENT MAY CHOOSE:
1. REVISE THE LANDSCAPE PLAN TO SHOW ONLY DROUGHT
TOLERANT PLANTS FROM THE CHESTERFIELD
COUNTY PLANT MATERIAL LIST. INSTALLATION OF
DROUGHT TOLERANT PLANT MATERIALS WILL EXEMPT
YOUR CLIENT FROM HAVING TO INSTALL AN IRRIGATION
SYSTEM TO SERVE THE PLANTINGS WITHIN THE 50'
PERIMETER SETBACK. THE FOLLOWING PLANTINGS
SHOWN ON THE PLANT SCHEDULE ON SHEET L1.2 ARE
NOT DROUGHT TOLERANT: WEEPING WILLOW,
THUNDERCLOUD PLUM, WHITE DOGWOOD &
ANTHONY WARTERER SPIREA. JEFF DOPP
HAS ATTACHED A COPY OF THE PLANT MATERIAL LIST
WITH THE EMAILED COMMENTS.
.
2. PROVIDE A CONTINUOUS MAINTENANCE, WATERING,
AND REPLACEMENT PROGRAM FOR PLANT MATERIALS
WITH A REPUTABLE LANDSCAPE MAINTENANCE
COMPANY FOR A MINIMUM OF 3 YEARS.
3. SUBMIT AN IRRIGATION COVERAGE PLAN THAT WILL
PROVIDE IRRIGATION COVERAGE FOR ALL PLANTINGS
WITHIN THE 50' PERIMETER SETBACK.
11. SHEET L1.0: ADD THE FOLLOWING GENERAL NOTE:
"MAINTENANCE OF REQUIRED LANDSCAPING SHALL BE THE
RESPONSIBILITY OF THE HOME OWNERS ASSOCIATION".
.
12. SHEET L1.2: PER SEC. 19.1-250. D. OF THE ZONING
ORDINANCE, THE MINIMUM SIZE FOR THE SHRUBS AT
TIME OF PLANTING IS 18" INCHES. PLEASE REVISE PLANT
SCHEDULE TO SHOW THIS MINIMUM HEIGHT.#####################
##########################################################
F
.
.
.
.
.
.
EMAIL--------DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN - GREENWICH WALK AT FOX CREEK PHASE 3
SITE PLAN NUMBER---16PR0250
1ST SUBMITTAL PLAN DATE-05/10/16
2ND SUBMITTAL PLAN DATE- 02/20/2017
3RD SUBMITTAL PLAN DATE -04/26/2017
SUBMITTAL NUMBER-------THREE
REVIEW DATE------------ 06/19/2017
RECOMMENDATION---NOT APPROVED
TABLE REVIEW----------- YES
LANDSCAPE PLAN STATUS- APPROVED
ARCHITECTURAL ELEVATIONS- REQUIRED
TO BE SUBMITTED & APPROVED PRIOR TO BUILDING
PERMIT SUBMITTAL.
LIGHTING PLAN/CUTSHEETS- RESPONSE
FROM DEVELOPER-NONE PROPOSED
IRRIGATION/HOSEBIB PLAN-COVERAGE PLAN
REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL.
.
REVIEW COMMENTS:
.
01. PUT A REVISION DATE ON THE RESUBMITTED
PLANS. RESUBMIT 12 FULL SETS & 1 COPY OF
THE SITE PLAN SHEET TO THE PLANNING
DEPARTMENT FOR YOUR NEXT REVIEW.
.
02. PROVIDE A WRITTEN RESPONSE TO COMMENTS
USING THE SPACE BELOW EACH COMMENT TO
DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. NOTE ON WHAT SHEET
EACH REQUESTED CHANGE IS PROVIDED.
.
03. PROVIDE A TRANSMITTAL LETTER TO
DESCRIBE ANY CHANGES TO THE PLANS NOT
CAUSED BY STAFF REVIEW COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM #)
04. SUBMIT A RESUBMITTAL FEE IN THE AMOUNT OF
$350.00.
.
05. AT TIME OF TABLE REVIEW, ON THREE OF THE
TWELVE SETS OF SITE PLANS, HI-LIGHT ALL CHANGES
MADE TO THE PLANS SINCE PREVIOUS SUBMITTAL.
.
06. SHEET C1.0: ADD ZONING CASE # 16SN0691
.
07. SHEETS C1.5-C1.9: SHOW APPROVED ZONING
CONDITIONS AND TEXTUAL STATEMENT TO FOR CASE
16SN0691 TO THE PROFFERED CONDITION SHEETS.
THE LANDSCAPE PLAN TO BE PREPARED BY A STATE
REGISTERED LANDSCAPE ARCHITECT OR NURSERYMAN.
CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL
LANDSCAPE PLAN IS APPROVED AND PLANTINGS ARE
INSTALLED. OUNDS OF BOUNDARY LINES.
.
09. SHEET C3.4: ON THE GRADING PLAN ADD
THE FOLLOWING NOTES:
" AT TIME OF COMPLETION OF CLEARING AND GRADING,
50' SETBACK WILL BE FLAGGED AND DEVELOPER WILL
CONTACT THE PLANNING DEPARTMENT FOR A LANDSCAPE
INSPECTION OF EXISTING PLANTINGS. HEALTHY
PLANTINGS WITHIN THE 50' SETBACK MAY BE
COUNTED TOWARDS PROPOSED PLANTINGS PROVIDED
THE PLANTINGS ARE REASONABLY DISTRIBUTED
THROUGHOUT THE 50' SETBACK."
"AT TIME OF COMPLETION OF CLEARING AND GRADING,
ALL BUFFERS WILL BE FLAGGED AND DEVELOPER WILL
CONTACT THE PLANNING DEPARTMENT FOR A BUFFER
INSPECTION. IF THE QUANTITIES OF HEALTHY PLANTINGS
ARE INSUFFICIENT AND THE PLANTINGS ARE NOT
REASONABLY DISTRIBUTED THROUGHOUT EACH BUFFER,
A LANDSCAPE PLAN WILL BE PREPARED AND SUBMITTED
IN ACCORDANCE WITH SECTION 19.1-27 E, REQUIRING
THE LANDSCAPE PLAN TO BE PREPARED BY A STATE
REGISTERED LANDSCAPE ARCHITECT OR NURSERYMAN.
CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL
LANDSCAPE PLAN IS APPROVED AND PLANTINGS ARE
INSTALLED.
##########################################################
##########################################################
5
==========================================================
==========================================================
REVIEW DEPARTMENT: IST / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : GREENWICH WALK AT FOX CREEK PH 3
PLAN NO. : 16PR0250
ADDRESS :
LATEST PLAN DATE : 5/9/16
RECEIVED DATE : 5/13/16
SUBMITTAL NUMBER : 1
REVIEW DATE : 6/1/16
RECOMMENDATION : APPROVED
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : GREENWICH WALK AT FOX CREEK PH 3
CASE NUMBER : 16PR0250
LATEST PLAN DATE : 2/20/17
RECEIVED DATE : 3/3/17
SUBMITTAL NUMBER : 2
REVIEW DATE : 3/20/17
ADDRESS : ADDRESS PLAN COMPLETE
STATUS : APPROVED
==========================================================
REVIEW DEPARTMENT: GIS + HOUSE NUMBERING
REVIEWER : AMY JOHANSON 768-7549
PROJECT NAME : GREENWICH WALK AT FOX CREEK PH 3
CASE NUMBER : 16PR0250
LATEST PLAN DATE : 5/9/17
RECEIVED DATE : 5/26/17
SUBMITTAL NUMBER : 3
REVIEW DATE : 6/12/17
ADDRESS : ADDRESS PLAN COMPLETE
STATUS : APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. THE GPIN # THAT PHASE 3 WILL BE COMING OUT OF HAS
CHANGED. THE NEW NUMBER IS 712-672-5652-00000.
==========================================================
==========================================================
==========================================================
DEPARTMENT REVIEW: IST / HOUSE NUMBERING SECTION
REVIEWER: NANCY PARKER
PHONE NUMBER: 751-4319
CASE NUMBER: 16PR0250
NAME OF PLAN:GREENWICH WALK AT FOX CREEK PH 3
ADDRESS: ADDRESS PLAN COMPLETE
DATE OF REVIEW:6/1/16 REVIEW # 1
STATUS: HOUSE NUMBERING APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: GREENWICH WALK @ FOXCREEK, PHASE 3
SITE PLAN NUMBER: 16PR0250
ADDRESS: 7311 OTTERDALE ROAD
LATEST PLAN DATE: 5/10/16
DEPT. REC'D. DATE: 5/16/16
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 5/16/16
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: GREENWICH WALK @ FOXCREEK, PHASE 3
SITE PLAN NUMBER: 16PR0250
ADDRESS: 7311 OTTERDALE ROAD
LATEST PLAN DATE: 2/20/17
DEPT. REC'D. DATE: 3/1/17
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 3/3/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: GREENWICH WALK @ FOXCREEK, PHASE 3
SITE PLAN NUMBER: 16PR0250
ADDRESS: 7311 OTTERDALE ROAD
LATEST PLAN DATE: 4/26/17
DEPT. REC'D. DATE: 5/26/17
SUBMITTAL NUMBER: 3RD REVIEW
REVIEW DATE: 5/26/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE SITE PLAN IS APPROVED AS SUBMITTED.
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : CATHY HILL, P.E. / 768-7836
NAME OF PLAN : GREENWICH WALK AT FOX CREEK PHASE 3
ADDRESS : 7201 OTTERDALE ROAD
SITE PLAN NO. : 16PR0250
LATEST PLAN DATE : 05/10/2016 (ENGINEER'S STAMP)
DEPT. REC'D DATE : 05/13/2016
SUBMITTAL NUMBER : 1
REVIEW DATE : 06/07/2016
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING :
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL
FEATURES INCLUDING BUT NOT LIMITED TO WETLANDS,
SURFACE WATERS (E.G. VSMP PERMIT FOR CONSTRUCTION
SITES, GROUND WATER AND AIR QUALITY) FINAL APPROVAL
OF THESE PLANS WILL NOT RELIEVE YOU OF YOUR
RESPONSIBILITY. WETLANDS DOCUMENTATION MUST BE
RECEIVED BY THIS DEPARTMENT PRIOR TO ISSUANCE OF THE
LAND DISTURBANCE PERMIT.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. EFFECTIVE JULY 1, 2014, ENFORCEMENT OF THE VIRGINIA
STORMWATER REGULATIONS BECAME THE RESPONSIBILITY OF
THE COUNTY FOR DEVELOPMENT PROJECTS WITHIN
CHESTERFIELD COUNTY. ADDITIONALLY, NEW STATE
STORMWATER REGULATIONS ALSO BECAME EFFECTIVE ON
JULY 1, 2014. LAND DISTURBING ACTIVITIES THAT
OBTAINED A VSMP PERMIT PRIOR TO JULY 1, 2014 MAY
USE THE STORMWATER MANAGEMENT CRITERIA SPECIFIED
IN PART II C (9VAC25-870-93 ET SEQ) FOR TWO PERMIT
CYCLES. PROJECTS GRANDFATHERED UNDER THE PROVISIONS
OF 9VAC25-870-48 MAY FOLLOW THE REQUIREMENTS LISTED
UNDER PART IIC FOR ONE PERMIT CYCLE. ALL OTHER NEW
DEVELOPMENT WILL BE SUBJECT TO THE REQUIREMENTS OF
PART IIB (9VAC25-870-62 TO 9VAC25-870-92).
03. IT IS ACCEPTABLE BUT NOT ADVISABLE TO SHOW
HYDROLOGICAL AND HYDRAULIC CALCULATIONS ON THE
PLANS. A REVISION TO THE CALCULATIONS CAN BE
HANDLED BETWEEN THE DESIGN ENGINEER AND THE
REVIEW ENGINEER WHEN THEY ARE A SEPARATE SUBMITTAL.
WHEN THEY ARE SHOWN ON THE PLANS, A COMPLETE
RESUBMITTAL OF THE PLANS TO THE PLANNING DEPARTMENT
IS REQUIRED. (CL-G&D 1)
04. PROVIDE A ROOF DRAIN PIPE TO THE SOUTH OF UNITS
161 AND 162 AND CONVEY THE ROOF RUNOFF TO
STRUCTURE 14.
05. PROVIDE CULVERT CALCULATIONS FOR THE QUADRUPLE
CULVERT STRUCTURE 38.
06. PROVIDE UPDATED CALCULATIONS FOR THE STORM SYSTEM
FROM E42 - E40.
07. PROVIDE 100-YEAR SWALE CALCULATIONS WHICH COMPARE
THE FINISHED FLOOR ELEVATIONS TO THE CHANNEL FLOW.
(SIMILAR TO THOSE PROVIDED FOR PHASES 1 AND 2).
08. PROVIDE MS-19 CALCULATIONS AT THE FOLLOWING LOCATIONS:
A. E40 OUTFALL
B. ROOF DRAIN B OUTFALL
C. ROOF DRAIN A OUTFALL
D. ROOF DRAIN D OUTFALL
09. EXTEND THE PROFILE FOR OUTFALL 1 TO SHOW THE GRADE
OF THE RECEIVING CHANNEL.
10. REFERENCE THE ENERGY DISSIPATOR DETAIL (SHEET C6.0)
IN PLAN VIEW ON SHEETS C3.3, C3.4, AND C3.5 WHERE
THEY ARE SPECIFIED AT OUTFALLS.
11. A SEPARATE PLAN SHEET MUST BE ADDED WHICH ONLY SHOWS
ALL PROPOSED EASEMENTS AND RIGHT OF WAY TO BE
DEDICATED. METES AND BOUNDS MUST BE PROVIDED.
(CL-G&D 30)
12. ENSURE ALL STREET NAMES HAVE BEEN APPROVED BY THE
RICHMOND REGIONAL PLANNING DISTRICT COMMISION (RRPDC)
STREET NAME CLEARINGHOUSE.
13. STREETLIGHTING:
A. STREETLIGHTS SHALL BE PROVIDED AT THE DEVELOPER'S
EXPENSE AT ANY AND ALL ENTRANCES AND EXITS OF
COMMERCIAL/INDUSTRIAL DEVELOPMENTS. LIGHTING SHALL BE
PROVIDED AS SPECIFIED IN THIS PARAGRAPH REGARDLESS OF
ANY OTHER LIGHTING CONSIDERATIONS, E.G., PARKING LOT
LIGHTING, SIGNAGE, OR TRAFFIC CONTROL LIGHTING.
B. IN ADDITION TO THE ACTUAL INSTALLATION COST OF ANY SUC
LIGHT(S), THE DEVELOPER SHALL PAY TO THE COUNTY AN
OPERATIONAL OFFSET FEE EQUIVALENT TO THE COST OF FIVE
YEARS OPERATION AND MAINTENANCE FOR EACH REQUIRED
STREETLIGHT INSTALLED BASED UPON THE SUPPLYING
UTILITY'S MONTHLY CHARGE FOR SAME PER LIGHT AT TIME OF
INSTALLATION, PLUS A $50 ADMINISTRATION FEE. REFER TO
THE STREETLIGHT POLICY FOR ACCEPTABLE LIGHTING
TYPES/STYLES (FOUND IN APPENDIX B OF THE ENVIRONMENTAL
ENGINEERING REFERENCE MANUAL).
C. ADDITIONAL, NON-REQUIRED STREETLIGHTS, BEYOND ANY
SPECIFICALLY REQUIRED IN PARAGRAPH A. ABOVE, SHALL BE
COST ESTIMATED, FUNDED, AND OPERATED AT THE DEVELOPER'
EXPENSE. NON-REQUIRED LIGHTING SHALL BE STRICTLY
LIMITED TO INTERNAL INTERSECTIONS WHERE ROADS ARE
IDENTIFIED AS INTENDED TO BE ACCEPTED INTO AND
MAINTAINED THROUGH THE STATE SECONDARY ROAD SYSTEM.
SUCH NON-REQUIRED INSTALLATIONS WILL NOT BE CONSIDERED
FOR FUTURE INCLUSION INTO THE COUNTY STREETLIGHT
PROGRAM.
D. PAYMENT OF THE OPERATIONAL OFFSET FEE, AS DESCRIBED
ABOVE, WILL BE REQUIRED AT A TIME NOT LATER THAN PLAN
APPROVAL. PAYMENT FOR THE COSTS OF STREETLIGHT
INSTALLATION AND THE $50 ADMINISTRATIVE FEE WILL BE
REQUIRED AT TIME OF RECEIPT OF THE PROJECT COST FROM
THE SUPPLYING UTILITY.
===================== EROSION CONTROL ===================
14. SAFETY FENCE (STD. & SPEC 3.01) IS REQUIRED AROUND ALL
SEDIMENT TRAPS AND SEDIMENT BASINS. (CL-EC 15)
15. A MINIMUM 10' BREAK MUST BE PROVIDED IN THE LOW AREA O
THE SILT FENCE . THE BREAK MUST BE BACKFILLED WITH
STONE TO WITHIN 1' OF THE TOP OF THE SILT FENCE TO
SERVE AS AN OVERFLOW. A DETAIL MUST BE SHOWN.
(CL-EC 16)
PROVIDE SILT FENCE BREAKS IN LINE WITH THE SEDIMENT
TRAP OUTFALLS.
16. SPECIFY SUPER SILT FENCE IN LIEU OF SILT FENCE
AT ALL PERIMETER LOCATIONS AROUND THE PROJECT.
17. REVISE THE DIVERSION DIKES LAYOUTS TO ST1 AND ST2,
ENSURE FLOW IS POSITIVELY DRAINING TO EACH TRAP.
18. SPECIFY EC BLANKET/MATTING AT ALL 3:1 SLOPES OVER
5 FEET IN HEIGHT ALONG THE PERIMETER OF THE PROJECT.
19. REVISE THE PIPE OUTLET PROTECTION DETAIL ON SHEET C2.5
TO SPECIFY 2' OF RIPRAP (INSTEAD OF 6"-9").
20. THE DETAIL SHOWN FOR CURB INLET PROTECTION MUST BE
CHANGED TO THE ONE SHOWN ON PLATE 3.07-8 OF STANDARD
AND SPECIFICATION # 3.07. (CL-EC 34)
21. SEDIMENT TRAPS MUST BE SIZED 25% LARGER FOR PROJECTS
WITHIN THE UPPER SWIFT CREEK WATERSHED.
===============CBPA/STORMWATER MANAGEMENT ================
22. REVISE THE CBPA COMPLIANCE SHEET TO CLARIFY THE
IMPERVIOUS AREAS VERSUS THE TOTAL AREAS.
=================== UPPER SWIFT CREEK ====================
23. CONDOMINIUM AND APARTMENT PROJECTS REQUIRE A BMP
MAINTENANCE FEE OF $100/UNIT. PAYMENT MUST BE RECEIVE
PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT.
(CL-USC 2)
24. ADDITIONAL EROSION CONTROL MEASURES OTHER THAN THE
MINIMUM STANDARDS CONTAINED IN THE VIRGINIA EROSION AN
SEDIMENT CONTROL HANDBOOK WILL BE REQUIRED IF IT IS
DETERMINED THAT SUCH MEASURES ARE NECESSARY FOR
PROTECTION OF SENSITIVE ENVIRONMENTAL FEATURES AND/OR
WATER RESOURCES. (CL-USC 3)
25. FOR SITES OVER FIVE ACRES, A MONTHLY EROSION AND
SEDIMENT CONTROL REPORT FROM THE CRLD MUST BE SUBMITTE
TO ENVIRONMENTAL ENGINEERING BY THE FIRST OF EACH
MONTH. (CL-USC 6)
======================= CLOSING ========================
26. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT AND OBTAIN AN "APPROVED FOR
CONSTRUCTION" STAMP ON TWO ADDITIONAL SETS FOR THE
OWNER TO KEEP ON-SITE.
27. A CONSTRUCTION PERFORMANCE BOND MUST BE PROVIDED FOR
THE IMPROVEMENTS WITHIN THE PROPOSED RIGHT OF WAY PRIO
TO ISSUANCE OF A BUILDING PERMIT FOR THIS PROJECT.
28. ALL ONSITE DRAINAGE EASEMENTS INCLUDING STORMWATER /
BMP DRAINAGE EASEMENTS MUST BE RECORDED PRIOR TO
ISSUANCE OF A BUILDING PERMIT FOR THIS PROJECT.
29. CONDOMINIUM PROJECTS REQUIRE A BMP MAINTENANCE FEE OF
$100/UNIT PRIOR TO ISSUANCE OF A LAND DISTURBANCE
PERMIT.
30. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD FILE MUST BE SUBMITTED TO CAROLE
CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE AUTOCAD
FILE MUST BE SAVED AS A .DWG OR .DXF IN AUTOCAD VERSIO
2009 OR EARLIER AND REFERENCED DIRECTLY TO THE VIRGINI
STATE PLANE COORDINATE SYSTEM, SOUTH ZONE IN THE NAD83
DATUM. THE AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD
OR VIA EMAIL AND MUST BE CLEARLY LABELED WITH THE SITE
PLAN NAME, SITE PLAN NUMBER, ENGINEERING FIRM AND CAD
FILE PREPARER'S NAME AND PHONE NUMBER. THE FILE MUST
CONTAIN THE FOLLOWING, EACH CLEARLY LABELED IN SEPARAT
LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. PARKING LOTS AND DRIVEWAYS;
C. ROADS;
D. SIDEWALKS;
E. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE; AND
F. FLOODPLAINS.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL ENGINEERING
PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
31. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
32. A VSMP HAS ALREADY BEEN ISSUED FOR THIS PROJECT.
33. A WETLANDS PERMIT HAS ALREADY BEEN ISSUED FOR THIS
PROJECT.
34. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) BOOK
C. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
==========================================================