Site Plan Review Comments
All Site Plan Review Comments for Case # 13PR0225
Modify comments view for Case # 13PR0225

Go to Case Selection Form or Go to Project List

 
CASE NO: 13PR0225 STATUS: PENDING APPROVAL
PROJECT NAME: CHEDDARS AT STONEHEN - LAST INTERNET UPDATE: 04/21/14
SUBMITTAL TYPE: COMMERCIAL
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 01 05/31/13 06/18/13 ******** ********
ENVIR.ENGR.-: 01 05/31/13 06/18/13 COMPLETE 06/13/13 SCD 748-1035
FIRE DEPT.--: 01 05/31/13 06/18/13 COMPLETE 06/11/13 GDS 706-2012
HOUSE NUMBER: 01 05/31/13 06/18/13 COMPLETE 06/12/13 NCP 751-4319
MAPPING/GIS-: 01 05/31/13 06/18/13 COMPLETE 06/14/13 NCP 751-4319
POLICE DEPT.: 01 05/31/13 06/18/13 ******** ********
PLANNING----: 01 05/31/13 06/18/13 COMPLETE 06/18/13 HHW 748-1989
TRANSPORT.--: 01 05/31/13 06/18/13 COMPLETE 06/10/13 SJA 751-4461
UTILITIES---: 01 05/31/13 06/18/13 AMENDED* 06/18/13 RME 748-1338
UTIL.R.O.W.-: 01 05/31/13 06/18/13 ******** ********
VDOT--------: 01 05/31/13 06/18/13 ******** ********
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RYAN EVANS, P.E./748-1338
NAME OF PLAN : CHEDDAR'S AT STONEHENGE VILLAGE
ADDRESS :
SUBMISSION DATE : 04/30/13
PLAN DATED : 04/12/13
REVIEW DATE : 05/06/13
SITE PLAN NO. : 13PR0225
COMMENTS : 1ST REVIEW-NOT APPROVED
TABLE REVIEW :
PLAT PROCESS :
1. SHOW THE COUNTY UTILITIES PROJECT NUMBER 13-0076 ON THE
LOWER RIGHT HAND CORNER OF EACH SHEET.
2. LABEL WHAT IS PROPOSED TO BE PUBLIC AND WHAT IS PROPOSED
AS PRIVATE ON BOTH PLAN AND PROFILE VIEWS. ALSO, SEPARATE
THE UTILITY QUANTITIES SIMILARLY.
3. ADD A NOTE THAT BEYOND THE WATER METER IT IS THE
PLUMBER'S RESPONSIBILITY TO INSTALL THE WATER SERVICE AND
THE WATER SERVICE WILL BE INSPECTED BY THE BUILDING
INSPECTION OFFICE. MARK THE WATER SERVICE BEHIND THE METER
"PRIVATE".
4. IN GENERAL, TAKE EVERY PRECAUTION TO ACCURATELY
DIFFERENTIATE BETWEEN EXISTING AND PROPOSED. TREAT
EVERYTHING ON THE STONEHENGE VILLAGE SITE PLAN AS EXISTING
FOR THE PURPOSES OF THIS RESTAURANT SINCE THIS APPROVAL IS
CONTINGENT UPON THE APPROVAL OF STONEHENGE VILLAGE.
5. REMOVE THE GRADING FROM THE WATERLINE EASEMENT ON THE
NORTH OF THE PROPERTY. THE EXISTING 30" WATERLINE IS
CURRENTLY AT MINIMUM COVER. THE PROPOSED CUTTING OF 1-3 FEET
OF COVER OVER THE WATERLINE CANNOT BE APPROVED.
6. IS THE EXISTING FIRE HYDRANT AT THE CONSTRUCTION
ENTRANCE PROPOSED TO BE RELOCATED WITH THE UTILITY PLAN? WHY
IS THERE A NOTE REGARDING THE SETTING OF THE HYDRANT 3'
BEHIND THE CURB IF THE HYDRANT IS EXISTING? CLARIFY AS
NECESSARY AND SPECIFY ON THE DEMO PLAN HOW THAT HYDRANT
SHALL BE PROTECTED DURING CONSTRUCTION.
7. SHOW THE DOMESTIC AND IRRIGATION TAPS PROCEEDING TO THE
WATER MAIN. CURRENTLY, NO PROVISIONS ARE MADE ON THE
STONEHENGE PLANS TO LEAVE A 1" AND 2" TAP TO THE CURB LINE
AND IT IS NOT DESIRED TO INSTALL THE WATER SERVICE LINES AT
TWO SEPARATE TIMES.
8. LABEL ALL SANITARY SEWER LINES AS PRIVATE.
9. REMOVE THE WATERLINE EASEMENT FROM THE BACKFLOW VAULT.
10. ON SHEET C-15, REVISE THE NAME OF THE FIRE SPRINKLER
BACKFLOW PREVENTER. IT IS CALLED A DOUBLE CHECK, NOT A
DOUBLE DETECTOR CHECK. SHOW WATERLINE RESTRAINTS FROM THE
TEE TO THE VAULT.
11. THE OWNER MUST ENTER INTO A COUNTY CONTRACT PRIOR TO
THE START OF CONSTRUCTION. PLEASE SEND JACQUE HYDEN A COPY
OF THE "ACCEPTED" BID PROPOSAL BETWEEN THE DEVELOPER AND THE
CONTRACTOR SO WE MAY PREPARE THE COUNTY CONTRACT. THE BID
PROPOSAL MUST BE BASED ON THE APPROVED SITE PLAN. ALL WORK
MUST BE PERFORMED BY AN ACCEPTABLE UTILITIES CONTRACTOR. IF
THE SITE PLAN IS REVISED AFTER THE UTILITY CONTRACT IS
PREPARED, A REVISED BID PROPOSAL MAY BE NECESSARY TO
ACCURATELY REFLECT THE LATEST APPROVED SITE PLAN, AND A NEW
CONTRACT PREPARATION MAY BE
NECESSARY.
12. AFTER COMPLETE SITE PLAN APPROVAL, SUBMIT THREE (3)
SETS OF PLANS DIRECTLY TO THE UTILITY DEPARTMENT FOR OUR
USE.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEWER/PHONE # : RYAN EVANS, P.E./748-1338
NAME OF PLAN : CHEDDAR'S AT STONEHENGE VILLAGE
ADDRESS :
SUBMISSION DATE : 06/04/13
PLAN DATED : 05/24/13
REVIEW DATE : 06/18/13
SITE PLAN NO. : 13PR0225
COMMENTS : 2ND REVIEW- NOT APPROVED
TABLE REVIEW : YES
PLAT PROCESS :
1. ALL UTILITIES COMMENTS HAVE BEEN SATISFIED. HOWEVER, PLAN
APPROVAL IS CONTINGENT UPON THE STONEHENGE PLAN APPROVAL.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: CHEDDARS AT STONEHENGE VILLAGE
SITE PLAN NUMBER: 13PR0225
LATEST PLAN DATE: 04/12/13
DEPT. REC'D. DATE: 05/06/13
SUBMITTAL NUMBER: ONE
REVIEW DATE: 05/06/13
RECOMMENDATION: NOT APPROVED-AWAITING ADJUSTMENT
APPROVAL OF 07PR0277 STONEHENGE
VILLAGE (PENDING ROAD IMPRVTS)
1. PRIOR TO ISSUANCE OF AN OCCUPANCY PERMIT FOR ANY
DEVELOPMENT ON THE PROPERTY, ROAD IMPROVEMENTS IDENTIFIED
IN PROFFERED CONDITION 7 OF CASE 12SN0241 SHALL BE
COMPLETED AS DETERMINED BY THE TRANSPORTATION DEPARTMENT
(PROFFERED CONDITION 8). ROAD IMPROVEMENTS ARE SHOWN ON
SITE PLAN 07PR0277 STONEHENGE VILLAGE AND ARE PENDING PLAN
APPROVAL.
2. NOTE THE ROAD CLASSIFICATION FOR MIDLOTHIAN TURNPIKE ON
THE PLAN. PER COUNTY THOROUGHFARE PLAN, IT IS NOTED AS A
MAJOR ARTERIAL. ALSO, NOTE THE RIGHT-OF-WAY AS "ULTIMATE
AND EXISTING RIGHT-OF-WAY LINE."
===========================================================
===========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN J. ADAMS, P.E. (804)751-4461
NAME OF PLAN: CHEDDARS AT STONEHENGE VILLAGE
SITE PLAN NUMBER: 13PR0225
LATEST PLAN DATE: 05/24/13
DEPT. REC'D. DATE: 06/05/13
SUBMITTAL NUMBER: TWO
REVIEW DATE: 06/10/13
RECOMMENDATION: NOT APPROVED-AWAITING APPROVAL OF
07PR0277 STONEHENGE VILLAGE ADJUSTMENT
PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY
DEVELOPMENT ON THE PROPERTY, ROAD IMPROVEMENTS IDENTIFIED
IN PROFFERED CONDITION 7 OF CASE 12SN0241 SHALL BE
COMPLETED AS DETERMINED BY THE TRANSPORTATION DEPARTMENT.
ROAD IMPROVEMENTS ARE SHOWN ON 07PR0277 STONEHENGE VILLAGE
AND ARE PENDING PLAN APPROVAL.
===========================================================
===========================================================
************************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----HORACE WADE/748-1989
NAME OF PLAN-----------CHEDDAR'S AT STONEHENGE VILLAGE
SITE PLAN NUMBER-------13PR0225
ADDRESS----------------TO BE ADDED
LATEST PLAN DATE-------4/12/13
DEPT. REC'D. DATE------4/18/13
SUBMITTAL NUMBER-------ONE
REVIEW DATE------------5/6/13
RECOMMENDATION---------REVISIONS REQUESTED
TABLE REVIEW-----------NO
PLAT PROCESSING--------
LANDSCAPE PLAN STATUS--SUBMITTED
ARCHITECTURAL ELEVATIONS--PARTIAL SUBMITTED
LIGHTING PLAN/CUTSHEETS---PARTIAL SUBMITTED
IRRIGATION/HOSEBIB PLAN---SUBMITTED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A COMPLETE
RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE PLANNING
DEPARTMENT.
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM NUMBER)
2. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER (13PR0225)
IN THE LOWER RIGHT CORNER OF EACH SHEET.
3. PER SEC. 19-264(D)(7), ADD ADAM SMITH'S FACSIMILE NUMBER
AND/OR E-MAIL ADDRESS.
4. PER SEC. 19-264(D)(13), ADD RYAN PERKIN'S FACSIMILE
NUMBER AND/OR E-MAIL ADDRESS.
5.SHOW ON PLANS ALL ADJACENT PROPERTIES WITH OWNER NAMES,
ZONING, AND CURRENT USES. INCLUDE ADJACENT PROPERTY NORTH
OF MIDLOTHIAN TURNPIKE (ROUTE 60) AND RESIDENTIAL PROPERTIES
TO THE SOUTH.
6. PER SEC. 19-505(B), MAKE SURE ALL SETBACKS FROM PUBLIC
ROADS ARE MEASURED FROM THE ULTIMATE RIGHT OF WAY. LABEL
THE EXISTING RIGHT OF WAY AND THE ULTIMATE RIGHT OF WAY
ALONG MIDLOTHIAN TURNPIKE ON THE SITE PLAN.
7. SHOW DIMENSIONS OF HANDICAP PARKING SPACES ADJACENT TO
CURBS SO THAT IT IS CONSISTENT WITH ACCESIBLE PARKING
DETAIL. TYPICAL GUTTER PAN CANNOT BE APART OF 8 FOOT
ACCESSIBLE PARKING SPACE. SLOPE EXCEEDS 2%.
8. PER EXHIBIT C FROM ZONING CASE (12SN0241) MOUNTING HEIGHT
FOR LIGHT POLE IS 25 FEET. CHANGE FROM 30 FEET TO 25 FEET.
9. PER SECTION 19-508.3 SHOW ON THE LANDSCAPE PLAN OR
ADDITIONALLY ON A SEPARATE LIGHTING PLAN THE LOCATION OF ALL
EXTERIOR SITE LIGHTING MOUNTED ON POLES, THE BUILDING, OR ON
THE GROUND AND HAVE THEM KEYED TO CUT SHEETS FOR EACH LIGT
FIXTURE SHOWN ON THE PLAN.
10. PER CONDITION 11E FROM ZONING CASE (12SN0241) CHANGE
SIGN AT PROPOSED DUMPSTER LOCATION TO STATE "NO SERVICE
BETWEEN 9PM - 7AM."
11. CHANGE "MIDLOTHIAN CITY" TO "CHESTERFIELD COUNTY" ON
LANDSCAPE NOTES ON SHEET L1.02 OF LANDSCAPE ENLARGEMENT
PLAN.
12. PER SECTION 19-518(E) ALL LANDSCAPED AREAS SHALL BE
PROVIDED WITH A READILY AVAILABLE WATER SUPPLY. SHOW PRIOR
TO ISSUANCE OF CERTIFICATE OF OCCUPANCY THAT IRRIGATION
SYSTEM PROVIDES COMPLETE COVERAGE.
13. PER SECTION 19-518(F) PRIOR TO RECEIVING A TEMPORARY
OCCUPANCY PERMIT, A FORM OF SURETY (BOND OR LETTER OF CREDIT
) IN THE AMOUNT EQUAL TO THE COST OF COMPLETING THE REQUIRED
LANDSCAPING SHALL BE PROVIDED TO THE PLANNING DEPARTMENT.
THE SURETY SHALL ALSO COVER AN AMOUNT EQUAL TO FIFTY (50)
PERCENT OF THE TOTAL INSTALLATION COST FOR REPLACEMENT OF
ALL UNHEALTY OR DEAD PLANTS OR POLLARDED TREES IDENTIFIED
BY THE ONE YEAR INSPECTION OF THE PLANNING DEPARTMENT.
14. INCLUDE NUMERICAL SCALE WITH GRAPHIC SCALE ON SHEET
NUMBERS C-04, C-07, C-09, C-10, C-11, C-12, C-13, C-16.
15. INCLUDE TOTAL REQUIRED HANDICAP SPACES IN PARKING
REQUIRED ON SHEET C-07.
16. REVISE GPIN TO BE CORRECT ON COVER SHEET.
17. PROVIDE A LETTER FROM SHOPPING CENTER DEVELOPER THAT THE
TOWERS IN THE SHOPPING CENTER WILL USE THE SAME PRIMARY ROOF
MATERIAL AS CHEDDAR'S.
************************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----HORACE WADE /748-1989
NAME OF PLAN-----------CHEDDARS AT STONEHENGE VILLAGE
SITE PLAN NUMBER-------13PR0225
ADDRESS----------------TO BE ADDED
LATEST PLAN DATE-------05/24/13
DEPT. REC'D. DATE------05/30/13
SUBMITTAL NUMBER-------TWO
REVIEW DATE------------06/14/13
RECOMMENDATION---------REVISIONS REQUESTED
TABLE REVIEW-----------NO
PLAT PROCESSING--------
LANDSCAPE PLAN STATUS--SUBMITTED
ARCHITECTURAL ELEVATIONS--PARTIAL SUBMITTED
LIGHTING PLAN/CUTSHEETS---SUBMITTED
IRRIGATION/HOSEBIB PLAN---SUBMITTED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. PROVIDE A COMPLETE
RESPONSE TO COMMENTS FOR ALL DEPARTMENTS TO THE PLANNING
DEPARTMENT.
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM NUMBER)
2. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER (13PR0225)
IN THE LOWER RIGHT CORNER OF EACH SHEET. SITE PLAN NUMER IS
MISSING FROM LANDSCAPE SHEETS (L1.02, L1.02, L1.03, L2.01,
L2.02).
3. SHOW ON PLANS (IN SMALLER SCALE) ALL ADJACENT PROPERTIES
WITH OWNER NAMES, ZONING, AND CURRENT USES. SHOW PARCELS
NORTH OF MIDLOTHIAN TURNPIKE (ROUTE 60) AND RESIDENTIAL
PARCELS TO THE SOUTH OF THE STONEHENGE VILLAGE PROJECT.
4. PREVIOUS COMMENT #14. NUMERICAL SCALE IS NECESSARY.
5. PLEASE SPECIFY THE MOUNTING HEIGHT OF THE LIGHT POLES.
ARE THE 20 FT POLES ATTACHED DIRECTLY TO THE PAVEMENT OR
ELEVATED ON A PIER? PLEASE SHOW DETAIL OF HOW THE LIGHT
POLESS ARE MOUNTED
6. LIGHTING PLAN CONDITIONALLY APPROVED. PRIOR TO RECIEVING
TEMPORARY OCCUPANCEY PERMIT, A NIGHT INSPECTION MUST BE MADE
TO VERIFY ALL LIGHTS ARE SHIELDED. THIS IS PARTICULARLY
IMPORTANT FOR ROOF MOUNTED LIGHTS WHICH MAY REQUIRE
ADDITIONAL SHIELDING.
==========================================================
==========================================================
REVIEW DEPARTMENT: IST / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : CHEDDARS AT STONEHENGE VILLAGE
PLAN NO. : 13PR0225
ADDRESS :
LATEST PLAN DATE : 4/12/13
RECEIVED DATE : 4/18/13
SUBMITTAL NUMBER : 1
REVIEW DATE : 5/10/13
RECOMMENDATION : NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. COORDINATE POINTS BASED ON THE VIRGINIA STATE PLANE
COORDINATE SYSTEM, SOUTH ZONE, NORTH AMERICAN DATUM
1983 ARE NOT PRESENT. TWO POINTS MUST BE SHOWN ON THE
SITE BOUNDARY, PREFERABLY ON CORNERS.
==========================================================
==========================================================
REVIEW DEPARTMENT: IST / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : CHEDDARS AT STONEHENGE VILLAGE
PLAN NO. : 13PR0225
ADDRESS :
LATEST PLAN DATE : 5/24/13
RECEIVED DATE : 5/30/13
SUBMITTAL NUMBER : 2
REVIEW DATE : 6/14/13
RECOMMENDATION : APPROVED
==========================================================
==========================================================
DEPARTMENT REVIEW: IST / HOUSE NUMBERING SECTION
REVIEWER: NANCY PARKER
PHONE NUMBER: 751-4319
CASE NUMBER: 13PR0225
NAME OF PLAN: CHEDDARS AT STONEHENGE VILLAGE
ADDRESS: 12640 STONE VILLAGE WAY
DATE OF REVIEW: 5/10/13 REVIEW # 1
STATUS: HOUSE NUMBERING NOT APPROVED
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS
CONCERNING THE COMMENTS BELOW.
1) LOCATION OF STREET ADDRESS SIGN IS NOT SHOWN.
(THE ADDRESS CAN BE PART OF YOUR MONUMENT SIGN.
THIS DOES NOT COUNT AS PART OF THE SQUARE FOOTAGE OF THE
SIGN. IF YOU ARE USING THE MONUMENT
SIGN FOR THE ADDRESS, A DETAIL OF THE MONUMENT SIGN
NEEDS TO BE ON THE SITE PLAN.)
2) SPECIFY THE MATERIAL THAT THE ADDRESS SIGN IS TO BE
MADE OF. (MATERIAL TO BE MORE DURABLE THAN WOOD).
==========================================================
==========================================================
DEPARTMENT REVIEW: IST / HOUSE NUMBERING SECTION
REVIEWER: NANCY PARKER
PHONE NUMBER: 751-4319
CASE NUMBER: 13PR0225
NAME OF PLAN: CHEDDARS AT STONEHENGE VILLAGE
ADDRESS: 12640 STONE VILLAGE WAY
DATE OF REVIEW: 6/12/13 REVIEW # 2
STATUS: HOUSE NUMBERING APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: GREG SMITH / 706-2012
EMAIL: SMITHGD@CHESTERFIELD.GOV
NAME OF PLAN: CHEDDARS AT STONEHENGE VILLAGE
SITE PLAN NUMBER: 13PR0225
ADDRESS: 13953 STONE VILLAGE WAY
LATEST PLAN DATE: 4/13/13
DEPT. REC'D. DATE: 5/1/13
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 5/7/13
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. PROVIDE THE REQUIRED THRUST BLOCK DESIGN AND RODDING
DETAIL CHART FOR FIRE PROTECTION UNDERGROUND. ALSO
PROVIDE THE MINIMUM CONCRETE AMOUNT DESIGN CHART. THRUST
BLOCKS FOR FIRE PROTECTION UNDERGROUND SHALL BE DESIGNED
AT A MINIMUM TEST PRESSURE OF 225 PSI. THE REQUIRED
CHARTS AND DETAILS CAN BE OBTAINED FROM THE INTERNET FOR
CHESTERFIELD COUNTY - CHESTERFIELD FIRE AND EMS -
DIVISION OF FIRE AND LIFE SAFETY -
HTTP://WWW.CHESTERFIELD.GOV/PUBLICSAFETY/FIRE/PLANS.ASP
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: GREG SMITH / 706-2012
EMAIL: SMITHGD@CHESTERFIELD.GOV
NAME OF PLAN: CHEDDARS AT STONEHENGE VILLAGE
SITE PLAN NUMBER: 13PR0225
ADDRESS: 13953 STONE VILLAGE WAY
LATEST PLAN DATE: 5/24/13
DEPT. REC'D. DATE: 6/3/13
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 6/11/13
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
1. THE REVISED PLAN IS APPROVED AS SUBMITTED.
============================================================
============================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1030
NAME OF PLAN : CHEDDAR'S
ADDRESS : XXXX STONE VILLAGE WAY
SITE PLAN NO. : 13PR0225
LATEST PLAN DATE : 04/12/13
DEPT. REC'D DATE : 04/25/13
SUBMITTAL NUMBER : ONE
REVIEW DATE : 05/09/13
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURES
INCLUDING BUT NOT LIMITED TO WETLANDS, SURFACE WATERS
(E.G. VSMP PERMIT FOR CONSTRUCTION SITES, GROUND WATER
AND AIR QUALITY) FINAL APPROVAL OF THESE PLANS WILL NOT
RELIEVE YOU OF YOUR RESPONSIBILITY. WETLANDS
DOCUMENTATION MUST BE RECEIVED BY THIS DEPARTMENT PRIOR
TO ISSUANCE OF THE LAND DISTURBANCE PERMIT.
(CL-XX #) REPRESENTS A SUBMITTAL CHECKLIST COMMENT -
SECTION AND COMMENT NUMBER
02. THE DRAINAGE PLAN MUST BE COORDINATED WITH THE OVERALL
STONEHENGE VILLAGE SITE PLAN.
03. CLEARLY SHOW THE STORM SEWER SYSTEM ON SHEET C-09.
04. CALCULATIONS MUST BE SUBMITTED TO SUPPORT THE DESIGN OF
ALL PROPOSED DROP INLETS ON VDOT STANDARD CALCULATION
SHEETS. (CL-G&D 11)
05. INLET SHAPING STD. IS-1 MUST BE SPECIFIED IN THE
TABULAR DRAINAGE DESCRIPTION FOR EACH MANHOLE AND DROP
INLET IN WHICH IT WAS USED IN THE HYDRAULIC GRADE LINE
CALCULATIONS. (CL-G&D 17)
06. A DETAIL MUST BE SHOWN ON THE PLANS FOR INLET SHAPING
STD. IS-1. IF INLET SHAPING CANNOT BE ACCOMPLISHED
WITHIN THE STANDARD STRUCTURE, THEN DETAILS MUST BE
PROVIDED FOR THE MODIFICATIONS NECESSARY TO THE
STRUCTURE TO ACCOMPLISH INLET SHAPING. (CL-G&D 19)
07. STEPS STD. ST-1 MUST BE SPECIFIED IN THE TABULAR
DRAINAGE DESCRIPTION OF ANY STRUCTURE OVER 4 FEET IN
HEIGHT. (CL-G&D 20)
08. BOOT CONNECTORS MUST BE SPECIFIED IN THE TABULAR
DRAINAGE DESCRIPTION FOR ALL PLASTIC PIPES THAT TIE INTO
A CONCRETE STRUCTURE. (CL-G&D 21)
09. DRAINAGE EASEMENTS MUST BE SHOWN ALONG ANY STORM-
WATER CONVEYANCE SYSTEM WHICH RECEIVES RUNOFF FROM
OFFSITE, FROM A PUBLIC RIGHT OF WAY OR REQUIRES
IMPROVEMENTS ON A DOWNSTREAM PROPERTY OWNER. (CL-G&D 29)
10. STEPS MUST BE INCLUDED IN THE SEQUENCE OF CONSTRUCTION
EVENTS FOR BUILDING CONSTRUCTION. (CL-EC 6)
11. REVISE THE PROPOSED SILT FENCE ON THE WESTERN SIDE OF
THE SITE TO SUPER SILT FENCE. A DETAIL IS REQUIRED.
12. PROVIDE AN MS-19 COMPLIANCE TABLE.
13. THE FOLLOWING ANALYSIS POINTS MUST BE INCLUDED IN THE
MS-19 COMPLIANCE TABLE:
A. THE DOWNSTREAM STORMSEWER SYSTEM;
B. THE DOWNSTREAM SWM/BMP; AND
C. THE DOWNSTREAM SWM/BMP OUTFALL.
14. ANY SOIL STOCKPILE AREA MUST BE LOCATED ON THE PLANS.
SILT FENCE MUST BE PROVIDED AROUND THE PERIMETER.
(CL-EC 39)
15. THE FOLLOWING NOTE(S) MUST BE ADDED TO OR ADJACENT TO
THE SEQUENCE OF CONSTRUCTION: (CL-EC 42)
A. A PAVED ACCESS FROM THE ENTRANCE TO A PUBLIC RIGHT-OF-
WAY MUST BE PROVIDED PRIOR TO ISSUANCE OF ANY OCCUPANCY
CERTIFICATES. (CL-EC 42C)
16. PERMISSION MUST BE OBTAINED FROM THE ADJACENT PROPERTY
OWNER(S) ALLOWING FOR GRADING ON THE PROPERTY AS
PROPOSED PRIOR TO ISSUANCE OF A LAND DISTURBANCE
PERMIT.
17. THE NAME, "WALK-IN ADDRESS", AND TELEPHONE NUMBER OF
A LOCAL REGISTERED AGENT REPRESENTING THE OWNER FOR
SERVICE OF PROCESS MUST BE PROVIDED PRIOR TO ISSUANCE OF
A LAND DISTURBANCE PERMIT.
18. ALL ONSITE DRAINAGE EASEMENTS INCLUDING STORMWATER /
B.M.P. DRAINAGE EASEMENTS MUST BE RECORDED PRIOR TO
ISSUANCE OF A BUILDING PERMIT FOR THIS PROJECT.
19. THE STORMWATER / B.M.P. FACILITY MUST BE CERTIFIED BY
A PROFESSIONAL ENGINEER PRIOR TO ISSUANCE OF ANY
OCCUPANCY CERTIFICATES.
20. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD .DWG OR .DXF MUST BE SUBMITTED TO
CAROLE CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE
AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD, OR VIA
EMAIL. THE FILE MUST CONTAIN THE FOLLOWING, EACH
CLEARLY IN SEPARATE LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. ALL IMPERVIOUS AREAS (PARKING LOTS, DRIVEWAYS, ROADS,
ETC);
C. THE STORM SEWER SYSTEM AND ALL CULVERTS;
D. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE;
E. STREAMS AND OTHER WATER BODIES;
F. LOCATIONS OF FIELD VERIFIED RESOURCE PROTECTION AREA
DESIGNATIONS TO INCLUDE WATER BODIES WITH PERENNIAL
FLOW, TIDAL SHORES, TIDAL WETLANDS, NON-TIDAL WETLANDS
WHICH ARE CONNECTED AND CONTIGUOUS TO TIDAL WETLANDS OR
PERENNIAL FLOW;
G. LOCATIONS OF PERENNIAL FLOW ORIGINS AND THEIR ASSOCIATED
GPS COORDINATES (NAD83 STATE PLANE VA SOUTH FEET);
H. LOCATION(S) OF BREAK POINT(S) IN SURFACE FLOW AND/OR
NON-CONTIGUOUS WETLANDS AND THEIR ASSOCIATED GPS
COORDINATES; AND
I. FLOOD PLAINS.
ALL AUTOCAD FILES MUST BE SAVED AS A .DWG OR .DXF IN
AUTOCAD VERSION 2009 OR EARLIER AND REFERENCED DIRECTLY
TO THE VIRGINIA STATE PLANE COORDINATE SYSTEM, SOUTH
ZONE IN THE NAD83 DATUM. THE CD, DVD, OR EMAIL MUST BE
LABELED WITH THE SITE PLAN NAME, SITE PLAN NUMBER,
ENGINEERING FIRM AND CONTACT NAME AND PHONE NUMBER.
21. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
22. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED)
C. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED
D. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
(AMOUNT TO BE APPROVED BY EE)
============================================================
============================================================
============================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1030
NAME OF PLAN : CHEDDAR'S
ADDRESS : XXXX STONE VILLAGE WAY
SITE PLAN NO. : 13PR0225
LATEST PLAN DATE : 05/24/13
DEPT. REC'D DATE : 06/03/13
SUBMITTAL NUMBER : TWO
REVIEW DATE : 06/13/13
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : NO
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURES
INCLUDING BUT NOT LIMITED TO WETLANDS, SURFACE WATERS
(E.G. VSMP PERMIT FOR CONSTRUCTION SITES, GROUND WATER
AND AIR QUALITY) FINAL APPROVAL OF THESE PLANS WILL NOT
RELIEVE YOU OF YOUR RESPONSIBILITY.
02. DUE TO THE DIVERSION OF DRAINAGE TO STRUCTURE 84, STORM
SEWER AND HYDRAULIC GRADELINE CALCULATIONS FOR STRUCTURE
84 DOWN TO THE SWM/BMP ARE REQUIRED.
03. THE FOLLOWING ANALYSIS POINTS MUST BE INCLUDED IN THE
MS-19 COMPLIANCE TABLE:
A. THE DOWNSTREAM STORMSEWER SYSTEM;
B. THE DOWNSTREAM SWM/BMP; AND
C. THE DOWNSTREAM SWM/BMP OUTFALL.
04. THE MINIMUM STANDARDS ON SHEET C-06 MUST BE UPDATED TO
REFLECT THE 2013 STANDARDS.
05. THE NAME, "WALK-IN ADDRESS", AND TELEPHONE NUMBER OF
A LOCAL REGISTERED AGENT REPRESENTING THE OWNER FOR
SERVICE OF PROCESS MUST BE PROVIDED PRIOR TO ISSUANCE OF
A LAND DISTURBANCE PERMIT.
06. THE STORMWATER / B.M.P. FACILITY MUST BE CERTIFIED BY
A PROFESSIONAL ENGINEER PRIOR TO ISSUANCE OF ANY
OCCUPANCY CERTIFICATES.
07. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A COPY
OF THE AUTOCAD .DWG OR .DXF MUST BE SUBMITTED TO
CAROLE CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE
AUTOCAD FILE MAY BE SUBMITTED ON A CD, DVD, OR VIA
EMAIL. THE FILE MUST CONTAIN THE FOLLOWING, EACH
CLEARLY IN SEPARATE LAYERS:
A. PROPOSED BUILDING FOOTPRINT;
B. ALL IMPERVIOUS AREAS (PARKING LOTS, DRIVEWAYS, ROADS,
ETC);
C. THE STORM SEWER SYSTEM AND ALL CULVERTS;
D. ALL JURISDICTIONAL WETLAND AREAS AND/OR WATERS OF THE
U.S./STATE;
E. STREAMS AND OTHER WATER BODIES;
F. LOCATIONS OF FIELD VERIFIED RESOURCE PROTECTION AREA
DESIGNATIONS TO INCLUDE WATER BODIES WITH PERENNIAL
FLOW, TIDAL SHORES, TIDAL WETLANDS, NON-TIDAL WETLANDS
WHICH ARE CONNECTED AND CONTIGUOUS TO TIDAL WETLANDS OR
PERENNIAL FLOW;
G. LOCATIONS OF PERENNIAL FLOW ORIGINS AND THEIR ASSOCIATED
GPS COORDINATES (NAD83 STATE PLANE VA SOUTH FEET);
H. LOCATION(S) OF BREAK POINT(S) IN SURFACE FLOW AND/OR
NON-CONTIGUOUS WETLANDS AND THEIR ASSOCIATED GPS
COORDINATES; AND
I. FLOOD PLAINS.
ALL AUTOCAD FILES MUST BE SAVED AS A .DWG OR .DXF IN
AUTOCAD VERSION 2009 OR EARLIER AND REFERENCED DIRECTLY
TO THE VIRGINIA STATE PLANE COORDINATE SYSTEM, SOUTH
ZONE IN THE NAD83 DATUM. THE CD, DVD, OR EMAIL MUST BE
LABELED WITH THE SITE PLAN NAME, SITE PLAN NUMBER,
ENGINEERING FIRM AND CONTACT NAME AND PHONE NUMBER.
08. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND SUBSTANTIAL OR FULL SITE PLAN APPROVAL IS REQUIRED
PRIOR TO ITS ISSUANCE. A LAND DISTURBANCE PERMIT IS
A PREREQUISITE TO A BUILDING PERMIT.
09. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED)
C. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED
D. POSTING OF AN EROSION AND SEDIMENT CONTROL SURETY
($14,990.25)
============================================================

Modify comments view for case # 13PR0225



Go to Case Selection Form or Go to Project List