Thanksgiving Holiday Closings... MORE

Hover here for Site Tools
Site Plan Review Comments
All Site Plan Review Comments for Case # 06PR0141
Modify comments view for Case # 06PR0141

Go to Case Selection Form or Go to Project List

 
CASE NO: 06PR0141 STATUS: PENDING APPROVAL
PROJECT NAME: HORNER PARK (2005) - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: PUBLIC-SEMI-PUB
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ENVIR.ENGR.-: 07 06/01/17 06/22/17 ******** 11/21/08 SCD 748-1035
FIRE DEPT.--: 07 06/01/17 06/22/17 ******** 11/10/08 SEH 748-1157
MAPPING/GIS-: 07 06/01/17 06/22/17 ******** 11/10/08 NCP 751-4319
PLANNING----: 07 06/01/17 06/22/17 COMPLETE 06/21/17 AGC 717-6042
TRANSPORT.--: 07 06/01/17 06/22/17 ******** 11/24/08 JWS 748-1037
UTIL.PLAN.--: 00 06/01/17 06/22/17 ******** ********
UTILITIES---: 07 06/01/17 06/22/17 ******** 11/14/08 DLT 717-6019
UTIL.R.O.W.-: 07 06/01/17 06/22/17 ******** ********
VDOT--------: 07 06/01/17 06/22/17 ******** 09/08/05 S S 674-2556
REVIEW DEPARTMENT: VIRGINIA DEPARTMENT OF TRANSPORTATION
REVIEWER/ PHONE : SANTI SEN. (804)674-2556
NAME OF PLANS: HORNER PARK
SITE PLAN NUMBER: 06PR0141
PLAN DATE: 08/09/05
DEPT. REC'D DATE: 08/15/05
SUBMITTAL NUMBER : ONE
REVIEW DATE : 09/07/05
VDOT LAND USE PERMIT: YES
RECOMMENDATION: NOT APPROVED
TABLE REVISION: NO
THE CONSTRUCTION OF ALL ROADWAYS WHICH ARE NOT DEFINED AS
ARTERIALS OR COLLECTORS IN CHESTERFIELD COUNTY
"THOROUGHFARE PLAN" REQUIRES THE IMPLEMENTATION
OF A COMPREHENSIVE INSPECTION PROGRAM TO INSURE COMPLIANCE
WITH VDOT ST'D AND SPECIFICATIONS. INSPECTION SERVICES
SHALL BE PREVIDE UTILIZING ONE OF THE FOLLOWING OPTIONS:
A. THE APPLICANT MAY RETAIN THE SERVICES OF A LICENSED
GEOTECHNICAL ENGINEER TO PERFORM THE REQUIRED INSPECTIO
AND TESTING.
B. THE APPLICANT MAY REQUEST THAT VDOT PROVIDE INSPECTION
SERVICES THROUGH THE ESTABLISHMENT OF AN ACCOUNTS
RECEIVABLE WITH THE CONTRACTOR RESPONSIBLE FOR PROVIDING
ALL REQUIRED MATERIAL TESTING.
THE CONSTRUCTION OF ALL ROADWAYS WHICH ARE DEFINED AS
ARTERIALS OR COLLECTORS IN CHESTERFIELD COUNTY
"THOROUGHFARE PLAN" REQUIRES THE IMPLEMENTATION OF A
COMPREHENSIVE INSPECTION PROGRAM TO INSURE COMPLIANCE WITH
VDOT STANDARDS AND SPECIFICATIONS. INSPECTION SERVICES
SHALL BE PROVIDED UTILIZING ONE OF THE FOLLOWING OPTIONS:
A THE APPLICANT MAY RETAIN THE SERVICES OF A LICENSED
GEOTECHNICAL ENGINEER TO PERFORM THE REQUIRED INSPECTION
AND TESTING.
B THE APPLICANT MAY REQUEST THAT VDOT PROVIDE INSPECTION
SERVICES THROUGH THE ESTABLISHMENT OF AN ACCOUNTS
RECEIVABLE WITH THE CONTRACTOR RESPONSIBLE FOR PROVIDING
ALL REQUIRED MATERIAL TESTING.
PLEASE CHOOSE ONE (1) OF THE ABOVE OPTIONS AND PLACE ON TH
COMMENTS:
T-1,
SHEET C-200
1) ADD TYPICAL SECTION FOR MT. HORNER ROAD WIDENING. PROVI
THE PAVEMENT DESIGN.
2) SHOW THE DESIGN VEHICLE TURNING MOVEMENTS AT INTERSECTI
OF LOOP ROAD AND MT. HORNER ROAD TO INSURE THE ENTRANCE
HAVE ENOUGH PAVEMENT FOR THE DESIGN VEHICLE TO ENTERING
THE LOOP ROAD WITHOUT TRACKING THE EDGE OF PAVEMENT.
3) IS MT. HORNER ROAD AN EXISTING ROAD? IF SO LABEL SUCH.
PROVIDE THE ROUTE NUMBER, POSTED SPEED LIMIT ON ALL SHE
4) A PAVEMENT JOINT DETAIL MUST BE ADDED TO THE PLAN. THIS
DETAIL SHOULD BE SHOWN THE EXISTING SURFACE COURSE BEIN
SAW CUT TO A DEPTH OF 2 INCHES, 1 FOOT OVER FROM THE
EXISTING EDGE OF PAVEMENT. THIS 1-FOOT WIDE BY 2 INCHES
DEEP STRIP OF SURFACE COURSE IS TO BE REMOVED AND CREAT
A BENCHED PAVEMENT JOINT THAT WILL HOPEFULLY REDUCE THE
AMOUNT OVERLAY REQUIRED.
5) ADD VDOT GENERAL NOTES IN ALL PLAN SET.
6) PROVIDE THE VERTICAL AND HORIZONTAL LINE OF SIGHT DISTA
AT THE INTERSECTION OF MT. MAIN ROAD AND HORNER ROAD.
7) VDOT STANDARD STOP SIGNS MUST BE SHOWN AT THE INTERSECT
OF NORTH LOOP ROAD AND MT HORNER ROAD. A NOTE "TO BE
FURNISHED AND INSTALLED BY THE DEVELOPER" MUST ALSO
BE SHOWN.
8) THE RIGHT TURN LANE STORAGE DIMENSION (200') SHALL BEGI
AT THE TRANSITION OF THE RADIUS NOT FROM THE CENTERLINE
OF THE CONNECTED ROAD. PLEASE REVISE.
SHEET C-201
9) MISSING FROM THE SET.
SHEET C-202
10) PROVIDE THE SIGHT DISTANCE VERTICAL AND HORIZONTAL LIN
AT THE INTERSECTIONS OF NORTH LOOP ROAD/MT. HORNER ROAD
FUTURE SOUTH LOOP ROAD/MT. HORNER ROAD.
11) VDOT STANDARD STOP SIGNS MUST BE SHOWN ON THE ROAD PLA
AT ALL INTERSECTIONS. A NOTE "TO BE FURNISHED AND INSTA
BY THE DEVELOPER" MUST ALSO BE SHOWN.
12) SHOW THE DESIGN VEHICLE TURNING MOVEMENTS AT ALL PROPO
ACCESSES TO INSURE THE ROAD HAVE ENOUGH PAVEMENT FOR
THE DESIGN VEHICLE TO ENTERING AND EXITING WITHOUT TRAC
THE EDGE OF PAVEMENT.
SHEET C-204, 206
13) PROVIDE THE SIGHT DISTANCE LINES VERTICAL AND HORIZONT
AT THE INTERSECTIONS OF MT. HORNER ROAD AND PARKING
LOT ENTRANCE.
14) VDOT STANDARD STOP SIGNS MUST BE SHOWN ON THE ROAD PLA
AT ALL INTERSECTIONS. A NOTE "TO BE FURNISHED AND INSTA
BY THE DEVELOPER" MUST ALSO BE SHOWN.
15) SHOW THE DESIGN VEHICLE TURNING MOVEMENTS AT ALL PROPO
ACCESSES TO INSURE THE ENTRANCE HAVE ENOUGH PAVEMENT FO
THE DESIGN VEHICLE TO ENTERING AND EXITING WITHOUT TRAC
THE EDGE OF PAVEMENT.
SHEET C-208
16) INSTALL AND LABEL A STANDARD BARRICADE AT THE END OF T
MT. HORNER ROAD.
17) PROVIDE THE SIGHT DISTANCE LINES VERTICAL AND HORIZONT
LOT ENTRANCE.
18) VDOT STANDARD STOP SIGNS MUST BE SHOWN ON THE ROAD
PLANS AT ALL ENTRANCES AND INTERSECTIONS. A NOTE
"TO BE FURNISHED AND INSTALLED BY THE DEVELOPER"
MUST ALSO BE SHOWN.
19) SHOW THE DESIGN VEHICLE TURNING MOVEMENTS AT PARKING L
ACCESSES TO INSURE THE ENTRANCE HAVE ENOUGH PAVEMENT FO
THE DESIGN VEHICLE TO ENTERING AND EXITING WITHOUT TRAC
THE EDGE OF PAVEMENT.
T-2,
SHEET C-302,304
20) 18" R.C.P. IS PLACED OUT SIDE OF THE RIGHT OF WAY.
DRAINAGE EASEMENT IS REQUIRED FOR VDOT TO MAINTAIN.
21) ALL CD'S ARE REQUIRED AN EW-12 AT THE END OF THE PIPES
PLEASE SHOW AND LABEL. ADD A STANDARD DETAIL.
22) SHOW THE VDOT DRAINAGE EASEMENT ON PLAN VIEW.
23) IT'S APPEAR THAT THE FILL GREAT IS TOO STEEP. PROVIDE
END WALL FOR STRUCTURE NUMBER 30.
SHEET, C-306
24) A PERMANENT DRAINAGE EASEMENTS ARE REQUIRED TO BE SHOW
LABELED AROUND THE STRUCTURES 11, 12, AND 95 ON PLAN VI
25) SPECIFY THE STANDARD ENDWALLS ON THE PLAN. ADD A DETAI
26) SHOW THE VDOT DRAINAGE EASEMENT ON PLAN VIEW.
27) PROVIDE THE STATIONING FOR THE STRUCTURES FOR THE STOR
SEWER STRUCTURAL SCHEDULE. NORTH AND EAST COORDINATES A
NOT ACCEPTABLE.
28) THERE IS NO STANDARD ARCH PIPE. PLEASE USE VDOT STANDA
ARCH PIPE AND ADD DETAIL OR PROVIDE FULL INFORMATION,
SPECIFICATION, AND DETAILS.
SHEET, C-308
29) VDOT DRAINAGE EASEMENT IS REQUIRED TO BE SHOWN ACROSS
THE CULVERT 71 AND 72.
30) VDOT DRAINAGE EASEMENT NEED TO BE SHOWN IN THE PLAN.
T-3
SHEET, C-501
31) PROVIDE VDOT STANDARD GUARDRAIL. PLEASE LABEL IN PLANS
32) SHOW THE COMPLETE TYPICAL SECTION WITH RIGHT OF WAY FO
MAIN ROAD. SPECIFY THE PAVEMENT DESIGN.
33) PLEASE PROVIDE ALL HYDROLOGIC AND HYDRAULIC COMPUTATIO
FOR ALL CULVERTS AND ROADSIDE DITCHES, IF ANY (PLEASE M
SURE THAT CULVERTS OUTLET VELOCITIES AND ROADSIDE DITCH
LININGS, AND ANY OTHER OUTLET PROTECTION ARE FULLY
CONSISTENT). PLEASE PROVIDE THE PERTINENT CALCULATIONS
SEND THEM IN VDOT FORMATS (OR RELATIVELY CLOSE FACSIMIL
SUCH AS LD-204, LD-268, LD-269 (CAN BE FOUND VDOT DRAIN
MANUAL), AND HEC-12 WITH FULL OUTPUT SUCH AS C, C.O.,
DRAINAGE AREA,
AND RAINFALL INTENSITY. PLEASE PLACE THEM IN AN ENVELOP
MARKED "VDOT" TO INSURE OUR RECEIPT.
SHEET 703
34) PROVIDE "CW" COMPUTATIONS FOR ALL SUB-AREAS OF THE
DRAINAGE BASIN.
35) RIGHT OF WAY AND ROAD CENTER LINE STATIONING SHALL SHO
IN ALL PLAN SHEETS.
NOTE:
THIS PROJECT GENERATED TOO MANY SHEERS OF DRAWINGS.
ACCORDING TO THE COMPLICITY OF THE PROJECT ONE SET SHOULD
SUFFICE.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEW ENGINEER : GARY HARTLE/748-1338
NAME OF PLAN : HORNER PARK
ADDRESS :
SUBMISSION DATE : AUGUST 11, 2005
PLAN DATED : AUGUST 9, 2005
REVIEW DATE : AUGUST 23, 2005
SITE PLAN NO. : 06PR0141
COMMENTS : 1ST REVIEW- NOT APPROVED
TABLE REVISION : YES
PLAT PROCESS : NO
1. SHOW THE COUNTY PROJECT NUMBER 01-0191 ON THE LOWER
RIGHT HAND CORNER OF EACH SHEET.
2. IT WILL BE NECESSARY AT SOME FUTURE TIME FOR
SANITARY SEWER TO BE EXTENDED ALONG OTTERDALE BRANCH AND
THE THREE TRIBUTARIES CROSSING THE PROPERTY, FOR ACCESS
TO ADJACENT PROPERTY. WHILE IT IS NOT REQUIRED FOR
COUNTY EASEMENTS TO BE RECORDED ON COUNTY PROPERTY, THE
EASEMENTS MUST BE SHOWN ON THIS PLAN AND PLATS PREPARED
AND SUBMITTED. SHOW 16' PERMANENT SEWER EASEMENTS WITH A
10' TEMPORARY CONSTRUCTION EASEMENT ON EACH SIDE. THERE
IS A GREAT DEAL OF FLEXIBILITY IN THE POSITIONS OF THESE
EASEMENTS, SO WE WILL LEAVE IT TO THE ENGINEER AND PARKS
AND RECREATION TO LOCATE THEM TO THEIR BEST ADVANTAGE.
3. ORGANIZE WATER SYSTEMS AND SEWAGE DISPOSAL
SYSTEMS TO ACCOMMODATE FUTURE CONNECTION TO THE PUBLIC
WATER AND SEWER SYSTEMS.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEW ENGINEER : DENEE TUCK/717-6019
NAME OF PLAN : HORNER PARK
ADDRESS :
SUBMISSION DATE : AUGUST 22, 2006
PLAN DATED : AUGUST 18, 2006
REVIEW DATE : AUGUST 24, 2006
SITE PLAN NO. : 06PR0141
COMMENTS : 2ND REVIEW- APPROVED
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEW ENGINEER : DENEE TUCK/717-6019
NAME OF PLAN : HORNER PARK
ADDRESS :
SUBMISSION DATE : NOVEMBER 1, 2007
PLAN DATED : OCTOBER 30, 2007
REVIEW DATE : NOVEMBER 13, 2007
SITE PLAN NO. : 06PR0141
COMMENTS : 3RD REVIEW- APPROVED
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEW ENGINEER : DENEE TUCK/717-6019
NAME OF PLAN : HORNER PARK
ADDRESS :
SUBMISSION DATE : MARCH 20, 2008
PLAN DATED : MARCH 17, 2008
REVIEW DATE : APRIL 1, 2008
SITE PLAN NO. : 06PR0141
COMMENTS : 4TH REVIEW- APPROVED
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEW ENGINEER : DENEE TUCK/717-6019
NAME OF PLAN : HORNER PARK
ADDRESS :
SUBMISSION DATE : MAY 30 30, 2008
PLAN DATED : MAY 27, 2008
REVIEW DATE : JUNE 6, 2008
SITE PLAN NO. : 06PR0141
COMMENTS : 5TH REVIEW- APPROVED
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEW ENGINEER : DENEE TUCK/717-6019
NAME OF PLAN : HORNER PARK
ADDRESS :
SUBMISSION DATE : SEPTEMBER 19, 2008
PLAN DATED : SEPTEMBER 17, 2008
REVIEW DATE : OCTOBER 6, 2008
SITE PLAN NO. : 06PR0141
COMMENTS : 6TH REVIEW- APPROVED
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES DEPARTMENT
REVIEW ENGINEER : DENEE TUCK/717-6019
NAME OF PLAN : HORNER PARK
ADDRESS :
SUBMISSION DATE : NOVEMBER 10, 2008
PLAN DATED : NOVEMBER 5, 2008
REVIEW DATE : NOVEMBER 14, 2008
SITE PLAN NO. : 06PR0141
COMMENTS : 7TH REVIEW- APPROVED
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
LATEST PLAN DATE: 08/09/05
DEPT. REC'D. DATE: 08/11/05
SUBMITTAL NUMBER: ONE
REVIEW DATE: 08/25/05
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: NA
1. CONDITION 3 OF SUBSTANTIAL ACCORD CASE 03PD0343 REQUIRE
CONSTRUCTION OF MOUNT HERMON ROAD FROM ITS CURRENT TERMINU
TO THE SOUTHERN PROPERTY LINE. A PHASING PLAN FOR THIS
CONSTRUCTION MUST BE APPROVED BY THE TRANSPORTATION
DEPARTMENT PRIOR TO SITE PLAN APPROVAL. THIS PHASING PLAN
MAY REQUIRE CONSTRUCTION OF THE ROAD WITH THIS PHASE OF TH
PARK DEVELOPMENT.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
LATEST PLAN DATE: 08/18/06
DEPT. REC'D. DATE: 08/21/06
SUBMITTAL NUMBER: TWO
REVIEW DATE: 09/08/06
RECOMMENDATION: SUBSTANTIAL APPROVAL
TABLE REVIEW: YES
PLAT PROCESSING: R/W
1. ADDITIONAL RIGHT OF WAY MUST BE DEDICATED ALONG EXISTIN
MOUNT HERMAN ROAD TO ELIMINATE THE SPITE STRIP BETWEEN IT
AND THE PROPERTY TO THE EAST.
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
LATEST PLAN DATE: 10/31/07
DEPT. REC'D. DATE: 10/30/07
SUBMITTAL NUMBER: THREE
REVIEW DATE: 11/16/07
RECOMMENDATION: APPROVAL
TABLE REVIEW: YES
PLAT PROCESSING: R/W
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
LATEST PLAN DATE: 03/17/08
DEPT. REC'D. DATE: 03/23/08
SUBMITTAL NUMBER: FOUR
REVIEW DATE: 04/04/08
RECOMMENDATION: APPROVAL
TABLE REVIEW: YES
PLAT PROCESSING: R/W
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
LATEST PLAN DATE: 05/27/08
DEPT. REC'D. DATE: 05/29/08
SUBMITTAL NUMBER: FIVE
REVIEW DATE: 06/11/08
RECOMMENDATION: APPROVAL
TABLE REVIEW: YES
PLAT PROCESSING: R/W
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
LATEST PLAN DATE: 09/17/08
DEPT. REC'D. DATE: 09/17/08
SUBMITTAL NUMBER: SIX
REVIEW DATE: 10/03/08
RECOMMENDATION: APPROVAL
TABLE REVIEW: YES
PLAT PROCESSING: R/W
==========================================================
==========================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMEN
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
LATEST PLAN DATE: 11/05/08
DEPT. REC'D. DATE: 11/07/08
SUBMITTAL NUMBER: SEVEN
REVIEW DATE: 11/24/08
RECOMMENDATION: APPROVAL
TABLE REVIEW: YES
PLAT PROCESSING: R/W
==========================================================
==========================================================
**********************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----ALAN COKER / (804)717-6042
NAME OF PLAN-----------HORNER PARK
SITE PLAN NUMBER-------06PR0141
ADDRESS----------------#####
LATEST PLAN DATE-------AUGUST 9, 2005
DEPT. REC'D. DATE------AUGUST 9, 2005
SUBMITTAL NUMBER-------ONE
REVIEW DATE------------SEPTEMBER 6, 2005
RECOMMENDATION---------NOT APPROVED
TABLE REVIEW-----------NO
PLAT PROCESSING--------
LANDSCAPE PLAN STATUS--MUST BE INCLUDED WITH 2ND SUBMISSIO
ARCHITECTURAL ELEVATIONS--NOT YET SUBMITTED
LIGHTING PLAN/CUTSHEETS---NOT YET SUBMITTED
IRRIGATION/HOSEBIB PLAN---NOT YET SUBMITTED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. USE THE SPACES
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM NUMBER)
2. ON THE LAYOUT SHEETS SHOW THE SETBACKS FROM THE RIGHT
OF WAY AND FROM THE PROPERTY LINES. (CL A.3)
3. THE ORDINANCE REQUIRES DRIVES TO BE PAVED. PROVIDE
INFORMATION RELATED TO 'NURSERY DRIVE' SHOWN AS GRAVEL.
(SEC. 19-514)
4. THE INFORMATION PROVIDED FOR TWO OF THE ADJACENT PARCEL
DOES NOT MATCH INFORMATION IN THE COUNTY RECORDS. REVISE.
THE INFORMATION WILL BE AVAILABLE DURING THE STAFF-DEVELOP
MEETING. (CL A.2)
5. AS A POINT OF INFORMATION, IMPROVEMENTS SHOWN AS 'FUTUR
ARE NOT VESTED WITH SITE PLAN APPROVAL. ADDITIONAL SITE
PLAN SUBMITTALS AND REVIEWS MAY BE REQUIRED FOR FUTURE
IMPROVEMENTS.
6. PUT THE CHESTERFIELD COUNTY SITE PLAN NUMBER (06PR0141)
IN THE LOWER RIGHT CORNER OF EACH SHEET. (CL B.1)
7. ON SHEET C310 NEAR THE BRONCO FIELD, SEVERAL CONTOURS
ARE MISLABELED. CORRECT.
8. ADDITIONAL INFORMATION IS NEEDED REGARDING THE SOIL/STO
STORAGE NEAR THE BALLFIELDS. PLEASE DISCUSS DURING THE
STAFF-DEVELOPER MEETING.
9. PUT A NOTE ON THE PLANS STATING "ANY SIGN IN EXCESS OF
EIGHT SQUARE FEET REQUIRES A PERMIT. PERMIT MUST BE
OBTAINED THROUGH THE BUILDING INSPECTION DEPARTMENT."(CLB.
10. ADD A NOTE TO THE PLANS STATING "ALL PROPOSED UTILITIE
ARE TO BE INSTALLED UNDERGROUND INCLUDING ELECTRIC,
TELEPHONE, AND CATV". (CL B.6)
11. DUMPSTER AND TRASH CONTAINERS MUST BE SCREENED FROM
PUBLIC RIGHT OF WAYS AND FROM OFF-SITE. INDICATE ON THE
PLANS THE METHOD OF CONTROL FOR TRASH (DUMPSTERS, TRASH
CONTAINERS, ETC.). CONTAINERS WITHIN 1000 FEET OF
RESIDENTIAL PROPERTY MAY NOT BE SERVICED BETWEEN 9PM-6AM.
(CL A.10)
12. ON THE LAYOUT PLANS SHOW THE PARKING BLOCKS.
13. REVISE THE SIZE OF DOGWOOD TO 2" CALIPER ON ALL
LANDSCAPE SHEETS.
14. ON THE LANDSCAPE SHEETS REVISE THE ONE YEAR MAINTENANC
TO THREE YEARS.
15. AT THE TIME OF SENDING COMMENTS, THE REVIEW FOR ADAAG
(HANDICAP ACCESSIBILITY) GUIDLINES WERE NOT COMPLETE.
PLEASE DISCUSS DURING THE STAFF-DEVELOPER MEETING.
16. PRIOR TO SITE PLAN APPROVAL, THE HEALTH DEPARTMENT
MUST APPROVE ALL WELL AND SEPTIC FIELDS. AT THE TIME OF
SENDING COMMENTS, APPROVAL HAS NOT BEEN RECEIVED FOR THIS
PROJECT.
17. A PREVIOUS SITE PLAN WAS SUBMITTED WITH THE TITLE
"HORNER PARK". FOR CLARITY, PROJECTS SHOULD NOT HAVE THE
SAME NAME. WRITTEN WITHDRAWAL OF THE PREVIOUS PROJECT IS
PREFERRED. (NOTE: THIS PLAN DOES NOT INCLUDE THE
MAINTENANCE AREA THAT WAS PART OF THE PREVIOUS PLAN).
18. PROVIDE ORANGE TREE PROTECTION FENCE AT THE GRADING
LIMITS WITHIN THE FRONT YARD SETBACKS ALONG THE PUBLIC
RIGHT OF WAY.
19. IF LIGHTING IS PROPOSED, PROVIDE TWO COPIES OF LIGHT
FIXTURE CUTSHEETS FOR REVIEW. LIGHTS MUST BE SHIELDED TYP
THAT PREVENT GLARE OFF SITE AND ALONG PUBLIC RIGHT OF WAY.
ALSO SHOW LOCATIONS OF ALL BUILDING MOUNTED AND FREE
STANDING LIGHT FIXTURES.
20. SHOW THE LOCATIONS OF ALL UTILITIES, INCLUDING WELL AN
SEPTIC FIELD LOCATIONS.
21. PROVIDE A COMPLETED INVESTIGATION WORKSHEET FOR GRAVES
MEMORIALS AND PLACES OF BURIAL. THE FORM PROVIDED DOES
NOT INDICATE IF GRAVES EXIST OR DO NOT EXIST.
22. THE LANDSCAPE CALCULATIONS PROVIDED ON THE COVER SHEET
IS NOT CORRECT. REVISE.
**********************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----ALAN COKER / (804)717-6042
NAME OF PLAN-----------HORNER PARK
SITE PLAN NUMBER-------06PR0141
ADDRESS----------------######
LATEST PLAN DATE-------AUGUST 9, 2006
DEPT. REC'D. DATE------AUGUST 18, 2006
SUBMITTAL NUMBER-------TWO
REVIEW DATE------------OCTOBER 12, 2006
RECOMMENDATION---------SUBSTANTIAL APPROVAL
TABLE REVIEW-----------YES
PLAT PROCESSING--------
LANDSCAPE PLAN STATUS--SUBMITTED/APPROVED AS NOTED
ARCHITECTURAL ELEVATIONS--NOT REQUIRED/NO BUILDINGS
LIGHTING PLAN/CUTSHEETS---NOT LIGHTING
IRRIGATION/HOSEBIB PLAN---MAINTENANCE
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. USE THE SPACES
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
2. PER PREVIOUS COMMENT 21.
PROVIDE A COMPLETED INVESTIGATION WORKSHEET FOR GRAVES
MEMORIALS AND PLACES OF BURIAL. THE FORM PROVIDED DOES
NOT INDICATE IF GRAVES EXIST OR DO NOT EXIST. PROVIDE A
CHECK NEXT TO WHERE THE FORM STATES "SELECT ONE" EITHER
INDICATING THAT GRAVES DO EXIST OR THAT GRAVES DO NOT
EXIST. PROVIDE AN UPDATED FORM TO PLANNING.
3. MASTER PLAN SHEET WAS ADDED TO THE SITE PLAN SET. WHIL
THIS DRAWING CLARIFIES THE OVERALL PROJECT AT COMPLETION,
IT MAY BE MISLEADING TO SOME. IF REVISED DRAWINGS ARE
SUBMITTED, PROVIDE A NOTE ON THE MASTER PLAN SHEET
INDICATION THAT THE SHEET IS PROVIDED FOR INFORMATION
ONLY RELATED TO THE OVER ALL SITE AT COMPLETION AND IS
NOT SUBMITTED FOR REVIEW AND APPROVAL.
IF REVISED DRAWINGS WILL NOT BE SUBMITTED, PROVIDE A
LETTER REFERENCING THE SHEET AND THE SAME CLARIFICATION.
(NOTE THAT ONE OF THE SOCCER FIELDS SHOWN IN CLOVER HILL
ATHLETIC PARK IS SHOWN AS BEING WITHIN THE 100 FT FIELD
SETBACK).
4. AS A POINT OF INFORMATION, IMPROVEMENTS SHOWN AS 'FUTUR
ARE NOT VESTED WITH SITE PLAN APPROVAL. ADDITIONAL SITE
PLAN SUBMITTALS AND REVIEWS MAY BE REQUIRED FOR FUTURE
IMPROVEMENTS.
**********************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----ALAN COKER / (804)717-6042
NAME OF PLAN-----------HORNER PARK
SITE PLAN NUMBER-------06PR0141
ADDRESS----------------
LATEST PLAN DATE-------OCTOBER 30, 2007
DEPT. REC'D. DATE------OCTOBER 30, 2007
SUBMITTAL NUMBER-------THREE
REVIEW DATE------------DECEMBER 7-18, 2007
RECOMMENDATION---------APPROVED
TABLE REVIEW-----------YES
PLAT PROCESSING--------
LANDSCAPE PLAN STATUS--SUBMITTED
ARCHITECTURAL ELEVATIONS--NOT REQUIRED/NO BUILDINGS
LIGHTING PLAN/CUTSHEETS---NOT REQUIRED/NO LIGHTING
IRRIGATION/HOSEBIB PLAN---MAINTENANCE
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. USE THE SPACES
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
**********************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----ALAN COKER / (804)717-6042
NAME OF PLAN-----------HORNER PARK (2005)
SITE PLAN NUMBER-------05PR0141
ADDRESS----------------
LATEST PLAN DATE-------MARCH 17, 2008
DEPT. REC'D. DATE------MARCH 17, 2008
SUBMITTAL NUMBER-------FOUR
REVIEW DATE------------APRIL 18, 2008
RECOMMENDATION---------APPROVED WITH COMMENT
TABLE REVIEW-----------YES
PLAT PROCESSING--------
LANDSCAPE PLAN STATUS--SUBMITTED
ARCHITECTURAL ELEVATIONS--NOT REQUIRED/NO BUILDINGS
LIGHTING PLAN/CUTSHEETS---NOT YET SUBMITTED/NO LIGHTING
IRRIGATION/HOSEBIB PLAN---MAINTENANCE
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. USE THE SPACES
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
(CL X.X REPRESENTS CHECKLIST ITEM NUMBER)
2. ON SHEET C316, SOME OF THE SPOT ELEVATIONS SHOWN AT
THE HANDICAP PARKING APPEAR TO BE OFF THE INTENDED
SPOT. REVIEW AND REVISE AS NEEDED.
**********************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----ALAN COKER / (804)717-6042
NAME OF PLAN-----------HORNER PARK (2005)
SITE PLAN NUMBER-------06PR0141
ADDRESS----------------#####
LATEST PLAN DATE-------SEPTEMBER 17, 2008
DEPT. REC'D. DATE------SEPTEMBER 16, 2008
SUBMITTAL NUMBER-------SIX
REVIEW DATE------------OCTOBER 8, 2008
RECOMMENDATION---------APPROVED
TABLE REVIEW-----------YES
PLAT PROCESSING--------YES
LANDSCAPE PLAN STATUS--SUBMITTED
ARCHITECTURAL ELEVATIONS--NOT REQUIRED/NO BUILDINGS
LIGHTING PLAN/CUTSHEETS---NOT YET SUBMITTED/NO LIGHTING
IRRIGATION/HOSEBIB PLAN---MAINTENANCE
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. USE THE SPACES
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
**********************************************************
REVIEW DEPARTMENT------PLANNING
REVIEWER / PHONE #-----ALAN COKER / (804)717-6042
NAME OF PLAN-----------HORNER PARK
SITE PLAN NUMBER-------06PR0141
ADDRESS----------------##########
LATEST PLAN DATE-------NOVEMBER 5, 2008
DEPT. REC'D. DATE------NOVEMBER 5, 2008
SUBMITTAL NUMBER-------SEVEN
REVIEW DATE------------DECEMBER 8, 2008
RECOMMENDATION---------APPROVED (WITH A COMMENT)
TABLE REVIEW-----------YES
PLAT PROCESSING--------
LANDSCAPE PLAN STATUS--APPROVED WITH COMMENT
ARCHITECTURAL ELEVATIONS--NOT REQUIRED/NO BUILDINGS
LIGHTING PLAN/CUTSHEETS---NOT YET SUBMITTED/NO LIGHTING
IRRIGATION/HOSEBIB PLAN---NOT YET SUBMITTED
1. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS AND ONE COPY OF THE SITE PLAN SHEET TO THE
PLANNING DEPARTMENT FOR YOUR NEXT REVIEW. USE THE SPACES
BELOW EACH COMMENT TO DESCRIBE HOW YOU HAVE ADDRESSED EACH
REVIEW COMMENT. BE SURE TO INDICATE WHICH SHEETS SHOW THE
REQUIRED CHANGES. PROVIDE A TRANSMITTAL LETTER TO DESCRIBE
ANY CHANGES TO THE PLANS NOT CAUSED BY THE STAFF REVIEW
COMMENTS.
FOR ALL SETS OF CALCULATIONS OR OTHER SUBMITTALS THAT ARE
FOR REVIEW BY SPECIFIC DEPARTMENTS OR VDOT, BOLDLY SHOW
THE DEPARTMENT NAME ON THAT INFORMATION OR PACKET.
2. AS A POINT OF INFORMATION, THE SUBSTANTIAL ACCORD
CONDITION 1 REQUIRES A LANDSCAPE DENSITY EQUIVALENT TO
2.5 TIMES PERIMETER LANDSCAPE "C" AT CERTAIN PERIMETER
LOCATIONS. WHILE THE LANDSCAPE PLANS NOTE THAT EXISTING
LANDSCAPING MEETS THE REQUIREMENT, AN INSPECTION OF THE
SITE WILL BE REQUIRED AFTER GRADING IS COMPLETE IN ORDER
TO DETERMINE IF ADDITIONAL LANDSCAPING IS REQUIRED TO MEET
THE DENSITY AND SCREENING REQUIREMENTS.
THIS REQUIREMENT WILL BE NOTED AS PART OF THE SITE PLAN
APPROVAL LETTER WHEN ISSUED.
IF REVISED PLANS ARE REQUIRED, PLACE A NOTE INDICATING
THE REQUIREMENT FOR THE INSPECTION ON THE LANDSCAPE PLANS.
*************************************************
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: STEVE PRUSIK/ 751-4321
PLAN NAME: HORNER PARK
PLAN NUMBER: 06PR0141
ORIGINAL PLAN DATE: 08/09/2005
REVIEW DATE: 06/21/17
LATEST SUBMISSION DATE: 06/01/17
SUBMITTAL NUMBER: 7
STATUS: APPROVED
TABLE REVIEW: YES
NOTES:
01. ANY CHANGE IN THE CURRENT PLAN, WHETHER IT STEMS
FROM DEPARTMENT COMMENTS OR AN ENGINEERING CHANGE
REQUESTED BY THE APPLICANT, MAY GENERATE ADDITIONAL
COMMENTS FROM THE REVIEWING DEPARTMENTS, RESULTING
IN REQUIRED REVISIONS.
==========================================================
==========================================================
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : HORNER PARK (2005)
SITE PLAN NO. : 06PR0141
ADDRESS :
LATEST PLAN DATE : 8/18/06
RECEIVED DATE : 8/22/06
SUBMITTAL NUMBER : 1
REVIEW DATE : 9/1/06
RECOMMENDATION : APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : HORNER PARK (2005)
SITE PLAN NO. : 06PR0141
ADDRESS :
LATEST PLAN DATE : 10/30/07
RECEIVED DATE : 10/30/07
SUBMITTAL NUMBER : 2
REVIEW DATE : 11/13/07
RECOMMENDATION : APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : HORNER PARK (2005)
SITE PLAN NO. : 06PR0141
ADDRESS :
LATEST PLAN DATE : 3/17/08
RECEIVED DATE : 3/18/08
SUBMITTAL NUMBER : 3
REVIEW DATE : 3/21/08
RECOMMENDATION : APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : HORNER PARK (2005)
SITE PLAN NO. : 06PR0141
ADDRESS :
LATEST PLAN DATE : 5/27/08
RECEIVED DATE : 5/29/08
SUBMITTAL NUMBER : 5
REVIEW DATE : 6/5/08
RECOMMENDATION : APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : HORNER PARK (2005)
SITE PLAN NO. : 06PR0141
ADDRESS :
LATEST PLAN DATE : 9/17/08
RECEIVED DATE : 9/18/08
SUBMITTAL NUMBER : 6
REVIEW DATE : 9/23/08
RECOMMENDATION : APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : HORNER PARK (2005)
SITE PLAN NO. : 06PR0141
ADDRESS :
LATEST PLAN DATE : 9/17/08
RECEIVED DATE : 11/7/08
SUBMITTAL NUMBER : 7
REVIEW DATE : 11/10/08
RECOMMENDATION : APPROVED
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: STEVE HALL / 748-1157
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
ADDRESS: MT. HERMON ROAD EXTENDED
LATEST PLAN DATE: 08-09-05
DEPT. REC'D. DATE:08-12-05
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 09-01-05
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: FRANK NAUSE / 706-2012
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
ADDRESS: MT. HERMON ROAD EXTENDED
LATEST PLAN DATE: 10/31/07
DEPT. REC'D. DATE: 10/31/07
SUBMITTAL NUMBER: 3RD REVIEW
REVIEW DATE: 10/31/07
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: FRANK NAUSE / 706-2012
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER: 06PR0141
ADDRESS: MT. HERMON ROAD EXTENDED
LATEST PLAN DATE: 03/17/08
DEPT. REC'D. DATE: 03/18/08
SUBMITTAL NUMBER: 4TH REVIEW
REVIEW DATE: 03/18/08
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: FRANK NAUSE / 706-2012
EMAIL: NAUSEF@CHESTERFIELD.GOV
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER:06PR0141
ADDRESS: MT. HERMAN ROAD EXTENTED
LATEST PLAN DATE: 9/17/08
DEPT. REC'D. DATE: 9/19/08
SUBMITTAL NUMBER: 6TH REVIEW
REVIEW DATE: 9/23/08
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
PLAT PROCESSING: YES
COMMENTS:
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: FRANK NAUSE / 706-2012
EMAIL: NAUSEF@CHESTERFIELD.GOV
NAME OF PLAN: HORNER PARK
SITE PLAN NUMBER:06PR0141
ADDRESS: MT. HERMAN ROAD EXTENTED
LATEST PLAN DATE: 11/05/08
DEPT. REC'D. DATE: 11/07/08
SUBMITTAL NUMBER: 7TH REVIEW
REVIEW DATE: 11/10/08
RECOMMENDATION: APPROVED
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1035
NAME OF PLAN : HORNER PARK
ADDRESS : MOUNT HERMON ROAD EXTENDED
SITE PLAN NO. : 06PR0141
LATEST PLAN DATE : 08/09/05
DEPT. REC'D DATE : 08/15/05
SUBMITTAL NUMBER : ONE
REVIEW DATE : 08/22/05
RECOMMENDATION : NOT APPROVED
TABLE REVISION : NO
PLAT PROCESSING : YES
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURE
INCLUDING BUT NOT LIMITED TO "WETLANDS, SURFACE WATERS
(E.G. VPDES PERMIT FOR CONSTRUCTION SITES OF 1 ACRE OR
MORE., GROUND WATER AND AIR QUALITY") FINAL APPROVAL
THESE PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILIT
WETLANDS DOCUMENTATION MUST BE RECEIVED BY THIS
DEPARTMENT PRIOR TO ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
(CL) REPRESENTS A CHECKLIST COMMENT.
02. A BENCHMARK MUST BE SHOWN WITH REFERENCE TO MEAN SEA
LEVEL. (CL)
03. REPLACE THE CG-7 CURB AND GUTTER WITH CG-6 CURB AND
GUTTER.
04. REPLACE THE DI-7'S WHICH INTERCEPT RUNOFF FROM ROADSID
DITCHES WITH DI-5'S.
05. CLARIFY THE PROPOSED GRADING ADJACENT TO THE RPA.
06. A VDOT STANDARD ENDWALL IS REQUIRED ON ALL MULTI LINE
STRUCTURES, STRUCTURES WITH DIAMETERS 30" AND LARGER,
AND WHEN THE STRUCTURE IS PROPOSED ON A SLOPE OF
15% OR GREATER. (CL) ADDRESS FOR STRUCTURES 9, 10, 21
AND 22
07. CLARIFY THE USE OF GRATE DI'S FOR STRUCTURES 27, 35, 3
52, 60, 64, 65 AND 66 IN LIEU OF OPEN ENDED CULVERTS.
08. CLARIFY THE INVERTS FOR STRUCTURE 94 TO 95 VERSUS THE
GRADES FOR THE PROPOSED PEDESTRIAN PATHWAY ON SHEET
C304.
09. SHOW THE DRAINAGE IMPROVEMENTS BETWEEN STRUCTURES 91 A
92 ON SHEET C310 AS SHOWN IN THE PROFILE ON SHEET C407
10. SPECIFY THE SLOPES OF THE ROAD SIDE DITCHES IN THE
PROFILES WHERE THE SLOPES DIFFER FROM THE ROAD GRADE.
11. CLARIFY THE PROFILE FOR STRUCTURE 94 TO 95 ON SHEET
C409.
12. STEPS STD. ST-1 MUST BE SPECIFIED IN THE TABULAR
DRAINAGE DESCRIPTION OF ANY STRUCTURE OVER 4 FEET IN
HEIGHT. (CL)
13. THE LIMITS OF THE 100-YEAR FLOOD PLAIN MUST BE SHOWN.
(CL)
14. PROVIDE A LARGER FONT FOR THE STRUCTURE NUMBERS ON SHE
C700 - C704.
15. THE EROSION CONTROL PLAN AND SEQUENCE/NARRATIVE MUST B
DIVIDED INTO A MINIMUM OF TWO PHASES.
PHASE I SHALL SHOW THE MINIMAL AMOUNT OF CLEARING TO
INCLUDE DIMENSIONS FOR CONSTRUCTION OF ALL PERIMETER-
CONTROL DEVICES, AND STRATEGICALLY PLACED SEDIMENT TRA
AND BASINS, ASSOCIATED DIVERSIONS AND DIVERSION DIKES,
AND SPOIL AND BORROW AREAS FOR THE INSTALLATION OF
EROSION CONTROL MEASURES.
PHASE II WILL INCLUDE ALL REMAINING CLEARING, GRADING,
AND INSTALLATION OF REMAINING EROSION CONTROL DEVICES,
INSTALLATION OF TEMPORARY AND PERMANENT IMPROVEMENTS,
AND TEMPORARY AND PERMANENT SEEDING AND STABILIZATION.
16. A NOTE MUST BE ADDED TO THE EROSION CONTROL NARRATIVE/
SEQUENCE OF CONSTRUCTION STATING THAT THE CERTIFIED
RESPONSIBLE LAND DISTURBER (CRLD) MUST ATTEND THE PRE-
CONSTRUCTION MEETING.
17. PROVIDE ADDITIONAL CHECK DAMS IN ALL PROPOSED ROAD SID
DITCHES.
18. PROVIDE SUPER SILT FENCE ON THE DOWNSTREAM SIDE OF ALL
MASS GRADING AREAS AND AT OTHER STRATEGIC LOCATIONS.
19. PROVIDE A DETAIL FOR SUPER SILT FENCE ON THE EROSION
CONTROL PLAN SHEET.
20. EROSION CONTROL MEASURES MUST BE PROVIDED FOR THE
PROJECT FOR THE INITIAL CLEARING, GRUBBING AND GRADING
OPERATIONS. THE DRAINAGE AREAS MUST BE OUTLINED AND TH
SEDIMENT TRAPPING FACILITIES DESIGNED ON THE WORST CAS
SCENARIO. (CL)
21. ANY SOIL STOCKPILE AREA MUST BE LOCATED ON THE PLANS.
SILT FENCE MUST BE PROVIDED AROUND THE PERIMETER IF
IT IS LOCATED OUTSIDE THE PERIMETER EROSION CONTROLS
FOR THE SITE. (CL)
22. EACH SEDIMENT TRAP AND SEDIMENT BASIN MUST BE ASSIGNED
AN ALPHA OR NUMERIC DESIGNATION AND THEIR INSTALLATION
SEQUENCE INDIVIDUALLY NOTED IN THE EROSION CONTROL
NARRATIVE. (CL)
23. THE FOLLOWING NOTE(S) MUST BE ADDED TO OR ADJACENT TO
THE EROSION CONTROL NARRATIVE / SEQUENCE OF
CONSTRUCTION: (CL)
A. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMI
FOR THIS PROJECT. (CL)
B. A VDOT LAND USE PERMIT IS REQUIRED FOR THIS PROJECT
PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT.
C. AT THE TIME OF THE PRE-CONSTRUCTION MEETING, TWO
STANDARD SIGNS MUST BE INSTALLED ON EACH SIDE OF THE
CONSTRUCTION ACCESS. THESE SIGNS MAY BE INSTALLED ON
TRIPOD DEVICES AND SHOULD STATE EITHER "CONSTRUCTION
ENTRANCE AHEAD" OR "TRUCKS ENTERING HIGHWAY".
24. THE CBPA COMPLIANCE NOTE ON THE COVER SHEET MUST BE
REVISED. PER THE MEETING ON AUGUST 15, 2005, PLEASE
PROVIDE WRITTEN CONFIRMATION FROM MR. MIKE GOLDEN OF
PARKS AND RECREATION THAT THE FUNDS ALLOCATED FOR THE
REGIONAL FACILITY IN THE BOND REFERENDUM WILL BE MADE
AVAILABLE TO ENVIRONMENTAL ENGINEERING ONCE CONSTRUCTI
OF THE FACILITY COMMENCES.
25. A PERENNIAL FLOW DETERMINATION MUST BE SUBMITTED TO TH
WATER QUALITY SECTION FOR REVIEW AND/OR APPROVAL PRIOR
TO SITE PLAN APPROVAL.
26. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
DISKETTE/CD, THE FORMAT OF WHICH SHALL BE AUTOCAD.DWG
DXF, MUST BE SUBMITTED TO VIRGINIA BARBOUR OF
ENVIRONMENTAL ENGINEERING. THE DISKETTE/CD MUST CONTA
THE FOLLOWING, EACH IN A SEPARATE LAYER:
A. FINAL GRADING CONTOUR LINES (5' INTERVALS);
B. PROPOSED BUILDING FOOTPRINT;
C. ALL IMPERVIOUS AREA (PARKING LOTS, DRIVEWAYS, ROADS,
ETC); AND
D. THE STORM SEWER SYSTEM.
A LAYER REPORT PRINTED FROM AUTOCAD MUST BE SUBMITTED
WITH THE DISKETTE/CD. BOTH THE DISKETTE/CD AND THE
REPORT MUST BE LABELED WITH THE SITE PLAN NAME, SITE
PLAN NUMBER, AND THE ENGINEERING FIRM. ALL AUTOCAD
FILES MUST BE REFERENCED DIRECTLY TO THE VIRGINIA STAT
PLANE COORDINATE SYSTEM, SOUTH ZONE, IN THE NAD83 DATU
27. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED (SITES OF ONE ACRE OR
MORE)
E. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1035
NAME OF PLAN : HORNER PARK
ADDRESS : MOUNT HERMON ROAD EXTENDED
SITE PLAN NO. : 06PR0141
LATEST PLAN DATE : 08/18/06
DEPT. REC'D DATE : 08/23/06
SUBMITTAL NUMBER : TWO
REVIEW DATE : 08/07/06
RECOMMENDATION : APPROVED
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURE
INCLUDING BUT NOT LIMITED TO "WETLANDS, SURFACE WATERS
(E.G. VPDES PERMIT FOR CONSTRUCTION SITES OF 1 ACRE OR
MORE., GROUND WATER AND AIR QUALITY") FINAL APPROVAL
THESE PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILIT
WETLANDS DOCUMENTATION MUST BE RECEIVED BY THIS
DEPARTMENT PRIOR TO ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
02. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL ENGINEERI
DEPARTMENT AND OBTAIN AN "APPROVED FOR CONSTRUCTION"
STAMP ON TWO ADDITIONAL SETS FOR THE OWNER TO KEEP
ON SITE.
03. CONSTRUCTION OF THIS PROJECT IS WITHIN THE SWIFT CREEK
RESERVOIR WATERSHED MANAGEMENT AREA WHICH REQUIRES
PAYMENT OF PRO-RATA SHARE FOR DEVELOPMENT IMPROVEMENTS
BASED ON THE IMPERVIOUS AREA OF THE SITE PLAN. THE
CURRENT COMPUTATION AND THE AMOUNT ARE AS FOLLOWS:
SWIFT CREEK RESERVOIR PRO RATA
"A" IMPERVIOUS AREA = 16.40 ACRES
ENR COST INDEX = $6222.00 APRIL 2001
ENR COST INDEX = $7763.15 SEPTEMBER 20
$5010.00("A")(ENR CURRENT)/$6222.00 = $102,515.50
REMITTANCE OF THIS AMOUNT MUST BE MADE WITH THE
LAND DISTURBANCE PERMIT APPLICATION AND WITHIN 60 DAYS
FROM THE DATE OF THIS LETTER IN ORDER TO AVOID
RECALCULATION OF THIS AMOUNT TO REFLECT CURRENT
CONSTRUCTION COST TRENDS.
04. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
DISKETTE/CD, THE FORMAT OF WHICH SHALL BE AUTOCAD.DWG
DXF, MUST BE SUBMITTED TO VIRGINIA BARBOUR OF
ENVIRONMENTAL ENGINEERING. THE DISKETTE/CD MUST CONTA
THE FOLLOWING, EACH IN A SEPARATE LAYER:
A. FINAL GRADING CONTOUR LINES (5' INTERVALS);
B. PROPOSED BUILDING FOOTPRINT;
C. ALL IMPERVIOUS AREA (PARKING LOTS, DRIVEWAYS, ROADS,
ETC); AND
D. THE STORM SEWER SYSTEM.
A LAYER REPORT PRINTED FROM AUTOCAD MUST BE SUBMITTED
WITH THE DISKETTE/CD. BOTH THE DISKETTE/CD AND THE
REPORT MUST BE LABELED WITH THE SITE PLAN NAME, SITE
PLAN NUMBER, AND THE ENGINEERING FIRM. ALL AUTOCAD
FILES MUST BE REFERENCED DIRECTLY TO THE VIRGINIA STAT
PLANE COORDINATE SYSTEM, SOUTH ZONE, IN THE NAD83 DATU
05. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED (SITES OF ONE ACRE OR
MORE)
E. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED
F. THE LIMITS OF THE RPA MUST BE FLAGGED IN THE FIELD
G. PAYMENT OF THE UPPER SWIFT CREEK PRO RATA FEE
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1035
NAME OF PLAN : HORNER PARK
ADDRESS : MOUNT HERMON ROAD EXTENDED
SITE PLAN NO. : 06PR0141
LATEST PLAN DATE : 10/30/07
DEPT. REC'D DATE : 10/31/07
SUBMITTAL NUMBER : THREE
REVIEW DATE : 11/19/07
RECOMMENDATION : APPROVED
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURE
INCLUDING BUT NOT LIMITED TO "WETLANDS, SURFACE WATERS
(E.G. VPDES PERMIT FOR CONSTRUCTION SITES OF 1 ACRE OR
MORE., GROUND WATER AND AIR QUALITY") FINAL APPROVAL
THESE PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILIT
WETLANDS DOCUMENTATION MUST BE RECEIVED BY THIS
DEPARTMENT PRIOR TO ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
02. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL ENGINEERI
DEPARTMENT AND OBTAIN AN "APPROVED FOR CONSTRUCTION"
STAMP ON TWO ADDITIONAL SETS FOR THE OWNER TO KEEP
ON SITE.
03. CONSTRUCTION OF THIS PROJECT IS WITHIN THE SWIFT CREEK
RESERVOIR WATERSHED MANAGEMENT AREA WHICH REQUIRES
PAYMENT OF PRO-RATA SHARE FOR DEVELOPMENT IMPROVEMENTS
BASED ON THE IMPERVIOUS AREA OF THE SITE PLAN. THE
CURRENT COMPUTATION AND THE AMOUNT ARE AS FOLLOWS:
SWIFT CREEK RESERVOIR PRO RATA
"A" IMPERVIOUS AREA = 16.40 ACRES
ENR COST INDEX = $6222.00 APRIL 2001
ENR COST INDEX = $8091.81 NOVEMBER 200
$5010.00("A")(ENR CURRENT)/$6222.00 = $106,855.59
REMITTANCE OF THIS AMOUNT MUST BE MADE WITH THE
LAND DISTURBANCE PERMIT APPLICATION AND WITHIN 60 DAYS
FROM THE DATE OF THIS LETTER IN ORDER TO AVOID
RECALCULATION OF THIS AMOUNT TO REFLECT CURRENT
CONSTRUCTION COST TRENDS.
04. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
DISKETTE/CD, THE FORMAT OF WHICH SHALL BE AUTOCAD.DWG
DXF, MUST BE SUBMITTED TO CAROLE CLIBORNE OF
ENVIRONMENTAL ENGINEERING. THE DISKETTE/CD MUST CONTA
THE FOLLOWING, EACH IN A SEPARATE LAYER:
A. FINAL GRADING CONTOUR LINES (5' INTERVALS);
B. PROPOSED BUILDING FOOTPRINT;
C. ALL IMPERVIOUS AREA (PARKING LOTS, DRIVEWAYS, ROADS,
ETC); AND
D. THE STORM SEWER SYSTEM.
A LAYER REPORT PRINTED FROM AUTOCAD MUST BE SUBMITTED
WITH THE DISKETTE/CD. BOTH THE DISKETTE/CD AND THE
REPORT MUST BE LABELED WITH THE SITE PLAN NAME, SITE
PLAN NUMBER, AND THE ENGINEERING FIRM. ALL AUTOCAD
FILES MUST BE REFERENCED DIRECTLY TO THE VIRGINIA STAT
PLANE COORDINATE SYSTEM, SOUTH ZONE, IN THE NAD83 DATU
05. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED (SITES OF ONE ACRE OR
MORE)
E. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED
F. THE LIMITS OF THE RPA MUST BE FLAGGED IN THE FIELD WIT
OPTIC ORANGE SAFETY FENCE
G. PAYMENT OF THE UPPER SWIFT CREEK PRO RATA FEE
H. THE DETAILS OF THE TEMPORARY STREAM CROSSING AT
STRUCTURE 11 TO 12, ALONG WITH A SHORT
CONSTRUCTION/INSTALLATION NARRATIVE, MUST BE SUBMITTED
TO AND APPROVED BY ENVIRONMENTAL ENGINEERING
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1035
NAME OF PLAN : HORNER PARK
ADDRESS : MOUNT HERMON ROAD EXTENDED
SITE PLAN NO. : 06PR0141
LATEST PLAN DATE : 03/17/08
DEPT. REC'D DATE : 03/18/08
SUBMITTAL NUMBER : FOUR
REVIEW DATE : 04/03/07
RECOMMENDATION : APPROVED
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURE
INCLUDING BUT NOT LIMITED TO "WETLANDS, SURFACE WATERS
(E.G. VPDES PERMIT FOR CONSTRUCTION SITES OF 1 ACRE OR
MORE., GROUND WATER AND AIR QUALITY") FINAL APPROVAL
THESE PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILIT
WETLANDS DOCUMENTATION MUST BE RECEIVED BY THIS
DEPARTMENT PRIOR TO ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
02. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL ENGINEERI
DEPARTMENT AND OBTAIN AN "APPROVED FOR CONSTRUCTION"
STAMP ON TWO ADDITIONAL SETS FOR THE OWNER TO KEEP
ON SITE.
03. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
DISKETTE/CD, THE FORMAT OF WHICH SHALL BE AUTOCAD.DWG
DXF, MUST BE SUBMITTED TO CAROLE CLIBORNE OF
ENVIRONMENTAL ENGINEERING. THE DISKETTE/CD MUST CONTA
THE FOLLOWING, EACH IN A SEPARATE LAYER:
A. FINAL GRADING CONTOUR LINES (5' INTERVALS);
B. PROPOSED BUILDING FOOTPRINT;
C. ALL IMPERVIOUS AREA (PARKING LOTS, DRIVEWAYS, ROADS,
ETC); AND
D. THE STORM SEWER SYSTEM.
A LAYER REPORT PRINTED FROM AUTOCAD MUST BE SUBMITTED
WITH THE DISKETTE/CD. BOTH THE DISKETTE/CD AND THE
REPORT MUST BE LABELED WITH THE SITE PLAN NAME, SITE
PLAN NUMBER, AND THE ENGINEERING FIRM. ALL AUTOCAD
FILES MUST BE REFERENCED DIRECTLY TO THE VIRGINIA STAT
PLANE COORDINATE SYSTEM, SOUTH ZONE, IN THE NAD83 DATU
04. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED
E. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED
F. THE LIMITS OF THE RPA MUST BE FLAGGED IN THE FIELD WIT
OPTIC ORANGE SAFETY FENCE
G. THE DETAILS OF THE TEMPORARY STREAM CROSSING AT
STRUCTURE 11 TO 12, ALONG WITH A SHORT
CONSTRUCTION/INSTALLATION NARRATIVE, MUST BE SUBMITTED
TO AND APPROVED BY ENVIRONMENTAL ENGINEERING
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1035
NAME OF PLAN : HORNER PARK
ADDRESS : MOUNT HERMON ROAD EXTENDED
SITE PLAN NO. : 06PR0141
LATEST PLAN DATE : 05/27/08
DEPT. REC'D DATE : 05/29/08
SUBMITTAL NUMBER : FIVE
REVIEW DATE : 06/16/08
RECOMMENDATION : APPROVED
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURE
INCLUDING BUT NOT LIMITED TO "WETLANDS, SURFACE WATERS
(E.G. VPDES PERMIT FOR CONSTRUCTION SITES OF 1 ACRE OR
MORE., GROUND WATER AND AIR QUALITY") FINAL APPROVAL
THESE PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILIT
WETLANDS DOCUMENTATION MUST BE RECEIVED BY THIS
DEPARTMENT PRIOR TO ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
02. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL ENGINEERI
DEPARTMENT AND OBTAIN AN "APPROVED FOR CONSTRUCTION"
STAMP ON TWO ADDITIONAL SETS FOR THE OWNER TO KEEP
ON SITE.
03. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
DISKETTE/CD, THE FORMAT OF WHICH SHALL BE AUTOCAD.DWG
DXF, MUST BE SUBMITTED TO CAROLE CLIBORNE OF
ENVIRONMENTAL ENGINEERING. THE DISKETTE/CD MUST CONTA
THE FOLLOWING, EACH IN A SEPARATE LAYER:
A. FINAL GRADING CONTOUR LINES (5' INTERVALS);
B. PROPOSED BUILDING FOOTPRINT;
C. ALL IMPERVIOUS AREA (PARKING LOTS, DRIVEWAYS, ROADS,
ETC); AND
D. THE STORM SEWER SYSTEM.
A LAYER REPORT PRINTED FROM AUTOCAD MUST BE SUBMITTED
WITH THE DISKETTE/CD. BOTH THE DISKETTE/CD AND THE
REPORT MUST BE LABELED WITH THE SITE PLAN NAME, SITE
PLAN NUMBER, AND THE ENGINEERING FIRM. ALL AUTOCAD
FILES MUST BE REFERENCED DIRECTLY TO THE VIRGINIA STAT
PLANE COORDINATE SYSTEM, SOUTH ZONE, IN THE NAD83 DATU
04. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED
E. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED
F. THE LIMITS OF THE RPA MUST BE FLAGGED IN THE FIELD WIT
OPTIC ORANGE SAFETY FENCE
G. THE DETAILS OF THE TEMPORARY STREAM CROSSING AT
STRUCTURE 11 TO 12, ALONG WITH A SHORT
CONSTRUCTION/INSTALLATION NARRATIVE, MUST BE SUBMITTED
TO AND APPROVED BY ENVIRONMENTAL ENGINEERING
H. PAYMENT OF THE UPPER SWIFT CREEK BMP MAINTENANCE FEE
($1500/IMPERVIOUS ACRE)
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1035
NAME OF PLAN : HORNER PARK
ADDRESS : MOUNT HERMON ROAD EXTENDED
SITE PLAN NO. : 06PR0141
LATEST PLAN DATE : 09/17/08
DEPT. REC'D DATE : 09/17/08
SUBMITTAL NUMBER : SIX
REVIEW DATE : 10/06/08
RECOMMENDATION : APPROVED
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURE
INCLUDING BUT NOT LIMITED TO "WETLANDS, SURFACE WATERS
(E.G. VPDES PERMIT FOR CONSTRUCTION SITES OF 1 ACRE OR
MORE., GROUND WATER AND AIR QUALITY") FINAL APPROVAL
THESE PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILIT
WETLANDS DOCUMENTATION MUST BE RECEIVED BY THIS
DEPARTMENT PRIOR TO ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
02. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL ENGINEERI
DEPARTMENT AND OBTAIN AN "APPROVED FOR CONSTRUCTION"
STAMP ON TWO ADDITIONAL SETS FOR THE OWNER TO KEEP
ON SITE.
03. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
DISKETTE/CD, THE FORMAT OF WHICH SHALL BE AUTOCAD.DWG
DXF, MUST BE SUBMITTED TO CAROLE CLIBORNE OF
ENVIRONMENTAL ENGINEERING. THE DISKETTE/CD MUST CONTA
THE FOLLOWING, EACH IN A SEPARATE LAYER:
A. FINAL GRADING CONTOUR LINES (5' INTERVALS);
B. PROPOSED BUILDING FOOTPRINT;
C. ALL IMPERVIOUS AREA (PARKING LOTS, DRIVEWAYS, ROADS,
ETC); AND
D. THE STORM SEWER SYSTEM.
A LAYER REPORT PRINTED FROM AUTOCAD MUST BE SUBMITTED
WITH THE DISKETTE/CD. BOTH THE DISKETTE/CD AND THE
REPORT MUST BE LABELED WITH THE SITE PLAN NAME, SITE
PLAN NUMBER, AND THE ENGINEERING FIRM. ALL AUTOCAD
FILES MUST BE REFERENCED DIRECTLY TO THE VIRGINIA STAT
PLANE COORDINATE SYSTEM, SOUTH ZONE, IN THE NAD83 DATU
04. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED
E. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED
F. THE LIMITS OF THE RPA MUST BE FLAGGED IN THE FIELD WIT
OPTIC ORANGE SAFETY FENCE
G. THE DETAILS OF THE TEMPORARY STREAM CROSSING AT
STRUCTURE 11 TO 12, ALONG WITH A SHORT
CONSTRUCTION/INSTALLATION NARRATIVE, MUST BE SUBMITTED
TO AND APPROVED BY ENVIRONMENTAL ENGINEERING
H. PAYMENT OF THE UPPER SWIFT CREEK BMP MAINTENANCE FEE
($1500/IMPERVIOUS ACRE)
==========================================================
==========================================================
==========================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : SCOTT DUNN, P.E. / 748-1035
NAME OF PLAN : HORNER PARK
ADDRESS : MOUNT HERMON ROAD EXTENDED
SITE PLAN NO. : 06PR0141
LATEST PLAN DATE : 11/05/08
DEPT. REC'D DATE : 11/06/08
SUBMITTAL NUMBER : SEVEN
REVIEW DATE : 11/21/08
RECOMMENDATION : RE-APPROVED
01. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND / OR ACQUIRE ALL APPLICABLE FEDERAL AND / OR
STATE PERMITS IN RELATIONSHIP TO ENVIRONMENTAL FEATURE
INCLUDING BUT NOT LIMITED TO "WETLANDS, SURFACE WATERS
(E.G. VPDES PERMIT FOR CONSTRUCTION SITES OF 1 ACRE OR
MORE., GROUND WATER AND AIR QUALITY") FINAL APPROVAL
THESE PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILIT
WETLANDS DOCUMENTATION MUST BE RECEIVED BY THIS
DEPARTMENT PRIOR TO ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
02. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ONE
ADDITIONAL SET OF PLANS TO THE ENVIRONMENTAL ENGINEERI
DEPARTMENT AND OBTAIN AN "APPROVED FOR CONSTRUCTION"
STAMP ON TWO ADDITIONAL SETS FOR THE OWNER TO KEEP
ON SITE.
03. PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
DISKETTE/CD, THE FORMAT OF WHICH SHALL BE AUTOCAD.DWG
DXF, MUST BE SUBMITTED TO CAROLE CLIBORNE OF
ENVIRONMENTAL ENGINEERING. THE DISKETTE/CD MUST CONTA
THE FOLLOWING, EACH IN A SEPARATE LAYER:
A. FINAL GRADING CONTOUR LINES (5' INTERVALS);
B. PROPOSED BUILDING FOOTPRINT;
C. ALL IMPERVIOUS AREA (PARKING LOTS, DRIVEWAYS, ROADS,
ETC); AND
D. THE STORM SEWER SYSTEM.
A LAYER REPORT PRINTED FROM AUTOCAD MUST BE SUBMITTED
WITH THE DISKETTE/CD. BOTH THE DISKETTE/CD AND THE
REPORT MUST BE LABELED WITH THE SITE PLAN NAME, SITE
PLAN NUMBER, AND THE ENGINEERING FIRM. ALL AUTOCAD
FILES MUST BE REFERENCED DIRECTLY TO THE VIRGINIA STAT
PLANE COORDINATE SYSTEM, SOUTH ZONE, IN THE NAD83 DATU
04. A LAND DISTURBANCE PERMIT IS REQUIRED FOR THIS PROJECT
AND THE FOLLOWING ARE REQUIRED PRIOR TO ITS ISSUANCE:
A. SUBSTANTIAL OR FULL SITE PLAN APPROVAL
B. A VDOT LAND USE PERMIT
C. A LETTER MUST BE RECEIVED FROM A QUALIFIED WETLANDS
EXPERT STATING:
1.THERE ARE NO WETLANDS IMPACTED ON THIS PROJECT, OR
2.ALL APPLICABLE FEDERAL AND STATE WETLAND PERMITS HAVE
BEEN ACQUIRED (COPIES OF THE PERMITS MUST BE SUBMITTED
D. COPIES OF THE VIRGINIA STORMWATER MANAGEMENT PERMIT
(VSMP) REGISTRATION STATEMENT AND PERMIT FEE FORM (AS
DEVELOPED BY THE DEPARTMENT OF CONSERVATION AND
RECREATION) MUST BE SUBMITTED
E. ALL ONSITE DRAINAGE EASEMENTS AND RIGHTS-OF-WAY MUST B
RECORDED
F. THE LIMITS OF THE RPA MUST BE FLAGGED IN THE FIELD WIT
OPTIC ORANGE SAFETY FENCE
G. THE DETAILS OF THE TEMPORARY STREAM CROSSING AT
STRUCTURE 11 TO 12, ALONG WITH A SHORT
CONSTRUCTION/INSTALLATION NARRATIVE, MUST BE SUBMITTED
TO AND APPROVED BY ENVIRONMENTAL ENGINEERING
H. PAYMENT OF THE UPPER SWIFT CREEK BMP MAINTENANCE FEE
($1500/IMPERVIOUS ACRE)
==========================================================

Modify comments view for case # 06PR0141