3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 18FC0011 STATUS: PENDING APPROVAL
PROJECT NAME: VANCE ESTATES - LAST INTERNET UPDATE: 11/20/17
SUBMITTAL TYPE: FINAL CHECK
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 08/15/17 08/29/17 COMPLETE 08/23/17 SSD 748-1348
ENVIR.ENGR.-: 00 08/15/17 08/29/17 ******** ********
FIRE DEPT.--: 00 08/15/17 08/29/17 COMPLETE 09/12/17 AWB 717-6167
MAPPING/GIS-: 00 08/15/17 08/29/17 COMPLETE 08/25/17 JMB 748-1280
PLANNING----: 00 08/15/17 08/29/17 ******** ********
TRANSPORT.--: 00 08/15/17 08/29/17 COMPLETE 08/29/17 SES 751-4912
UTIL.PLAN.--: 00 08/15/17 08/29/17 ******** ********
UTILITIES---: 00 08/15/17 08/29/17 ******** ********
UTIL.R.O.W.-: 00 08/15/17 08/29/17 ******** ********
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: VANCE ESTATES SUBDIVISION
CASE NUMBER: 18FC0011
LATEST PLAN DATE: 07/10/2017
DEPT. REC'D. DATE: 08/21/2017
SUBMITTAL NUMBER: ONE
REVIEW DATE: 08/29/2017
RECOMMENDATION: PENDING
TABLE REVIEW: NA
.
REVIEW IS PENDING RESOLUTION OF THE PARCEL BOUNDARY
DISCREPANCY.
.
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : WHIT KIRTLEY / 706-7691
PLAN NAME : VANCE ESTATES
PLAN NUMBER : 18FC0011
ORIGINAL PLAN DATE : 3/23/17
LATEST SUBMISSION DATE : 8/14/17
REVIEW DATE:29/11/17
SUBMITTAL NUMBER :1
STATUS : REVISIONS REQUIRED
.
.
1. THE TITLE OF THE PLAT SHOULD BE "VANCE ESTATES". PLEASE
AND BE SURE THE NEW TITLE MATCHES THE DESCRIPTION IN THE
TITLE BLOCK
.
2. ADD ZONING CASE89SN0267 TO THE NOTES
.
3. ADD EXCEPTION CASE 18TW0124 TO THE NOTES
.
4. ADD A SIGNATURE BLOCK FOR THE "PLANNING DEPARTMENT"
5. SIGN ALL CERTIFICATES AND SEALS
.
6. UPDATE THE VICINITY MAP SO THAT ROAD NAMES ARE VISIBLE
.
7. STANDARD CONDITIONS OF 17-62
.
8. ADD SUBDIVISION ID 0859-01
.
9. ADD TYPE OF WATER AND WASTEWATER SERVICE IN THE NOTES
10. CHANGE THE MAGISTERIAL DISTRICT TO BERMUDA
.
11. PROVIDE THE METHOD OF CBPA COMPLIANCE IN THE NOTES
.
12. CONDITION 1 OF ZONING CASE 89SN0267 REQUIRED CONNECTION
TO THE PUBLIC SYSTEM. IT APPEARS THAT THE APPLICANT WAS
DENIED PERMISSION TO CONNECT TO THE COLONIAL HEIGHTS.
AN AMENDMENT OF CASE 89SN0297 WILL BE REQUIRED TO
REMOVE THE CONNECTION REQUIREMENT. ADDITIONAL
EXCEPTIONS MAY BE REQUIRED SINCE THE AREA IS NOW
LOCATED IN A MANDATORY CONNECTION AREA FOR BOTH
WATER AND SEWER.
==========================================================
==========================================================
-
REVIEW DEPARTMENT: IST / GIS
REVIEWER : JASON BYERS 717-6356
NAME OF PLAN : VANCE ESTATES SUBDIVISION
PLAN NO. : 18FC011
ADDRESS :
LATEST PLAN DATE : 3/23/2017
RECEIVED DATE : 8/14/2017
SUBMITTAL NUMBER : 1
REVIEW DATE : 8/25/2017
RECOMMENDATION : NOT APPROVED
-
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
-
1. MISSING SUBDIVISION ID NUMBER
2. MISSING TENTATIVE NUMBER
3. BUFFER NEEDS BUFFER STATEMENT IN NOTES SECTION
4. SUBDIVISION NAME DOES NOT MATCH SUBDIVISION CERTIFICATE N
AME. PLEASE CORRECT ONE OR THE OTHER
REVIEW DEPARTMENT: FIRE
REVIEWER/PHONE#: ANTHONY BATTEN / 717-6167
EMAIL: BATTENA@CHESTERFIELD.GOV
NAME OF PLAN: VANCE ESTATES SUBDIVISION
PLAN NUMBER: 18FC0011
LATEST PLAN DATE: 7/10/17
DEPT. REC'D. DATE: 8/21/17
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 8/22/17
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
REVIEW DEPARTMENT :ASSESSORS
REVIEWER / PHONE # :SHARON DRISKILL/748-1348
PLAN NAME :VANCE ESTATES
PLAN NUMBER :18FC0011
ORIGINAL PLAN DATE :
REVIEW DATE :8-23-17
LATEST SUBMISSION DATE :
SUBMITTAL NUMBER :
STATUS :1) TITLE BLOCK & SUB CERTIFICATE DO
NOT MATCH(2) UNDER NOTES TOTAL AREA IS WRONG(3) SIGNATURES
NEED TO BE BY TRUSTEES(4)LABEL & SHOW INFO FOR 795-629-4652
(5) 7956294576 IS WRONG (6) ADD "JR" BEHIND OWNER'S NAME ON
795-628-3690 (7) CORRECT OWNER'S NAME & DEED BOOK & PG AND
PUT ADDRESS ON 795-628-1414 (8) CORRECT TAX ID# & OWNER'S
NAME ON 17311 BRANDERS BRIDGE RD & ADD STREET NAME (9) ON
794-628-4842 ADD THE STREET NAME.