Subdivision Review Comments
All Subdivision Review Comments for Case # 17TS0238




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 17TS0238 STATUS: PENDING APPROVAL
PROJECT NAME: CENTERPOINTE TOWNHOM - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: TENTATIVE SUBDIVISION
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 04/24/17 05/22/17 ******** ********
ENVIR.ENGR.-: 02 09/18/17 10/09/17 COMPLETE 11/16/17 RWB 748-1035
FIRE DEPT.--: 02 09/18/17 10/09/17 AMENDED* 11/16/17 JKL 748-1489
MAPPING/GIS-: 02 09/18/17 10/09/17 ******** ********
PLANNING----: 02 09/18/17 10/09/17 COMPLETE 11/21/17 CH 717-6042
PARKS & REC.: 02 09/18/17 10/09/17 ******** ********
SCHOOL BOARD: 02 09/18/17 10/09/17 ******** ********
TRANSPORT.--: 02 09/18/17 10/09/17 COMPLETE 10/09/17 SES 751-4912
UTIL.PLAN.--: 02 09/18/17 10/09/17 ******** ********
UTILITIES---: 02 09/18/17 10/09/17 AMENDED* 11/20/17 TVM 751-4435
UTIL.R.O.W.-: 02 09/18/17 10/09/17 ******** ********
VDOT--------: 02 09/18/17 10/09/17 ******** ********
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE # : TERRY MAPLES 751-4435
PLAN NAME : CENTERPOINTE TOWNHOMES
PLAN NUMBER: 17TS0238
ORIGINAL PLAN DATE: 4/12/17
REVIEW DATE: 11/20/17
LATEST SUBMISSION DATE: 11/16/17
SUBMITTAL NUMBER: 4
STATUS: APPROVED
TABLE REVIEW:
.
.
.
1. THIS OFFICE MAY REQUIRE REDESIGN OR MODIFICATIONS TO
THE PROPOSED SEWER LAYOUT, AS SHOWN ON THE LATEST
PRELIMINARY PLAN, ONCE THE FIELD WORK, GRADING PLAN
AND SEWER DESIGN HAS BEEN COMPLETED BY THE
ENGINEER AND SHOWN ON INITIAL CONSTRUCTION PLAN
SUBMITTAL FOR REVIEW AND APPROVAL. (U)
.
2. IT WILL BE THE RESPONSIBILITY OF THE SUB DIVIDER TO
MAKE CERTAIN, BY WHATEVER MEANS NECESSARY,
(I.E., ON-SITE WATER LINE LOOPING OR OFF-SITE
WATER LINE EXTENSIONS, ETC.) THAT THE DEMANDS
GENERATED BY THE PROPOSED PROJECT DO NOT CAUSE ANY
AREA WITHIN THE PRESSURE ZONE TO FAIL TO COMPLY
WITH THE CHESTERFIELD COUNTY FIRE DEPARTMENT'S
REQUIRED FIRE FLOW OF 1000 GPM AT 20 PSI
RESIDUAL. (U)
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: CENTERPOINTE TOWNHOMES
CASE NUMBER: 17TS0238
LATEST PLAN DATE: 04/12/2017
DEPT. REC'D. DATE: 05/01/2017
SUBMITTAL NUMBER: ONE
REVIEW DATE: 05/24/2017
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
.
1. IN ACCORDANCE WITH THE APPROVED PHASING PLAN DATED JUNE
23, 2015, CENTER POINTE PARKWAY SHALL BE WIDENED TO A FOUR
LANE DIVIDED FACILITY FROM CHARTER COLONY PARKWAY THROUGH
ITS INTERSECTION WITH BRANDERMILL PARKWAY.
.
2. IN ACCORDANCE WITH THE APPROVED PHASING PLAN DATED JUNE
23, 2015, A TRAFFIC SIGNAL SHALL BE INSTALLED AT THE
INTERSECTION OF CHARTER COLONY PARKWAY AND BRANDERMILL
PARKWAY.
.
3. THE ACCESSES SHOWN ALONG CHARTER COLONY PARKWAY ARE NOT
IN ACCORDANCE WITH THE APPROVED ACCESS PLAN. THE ACCESS
PLAN MUST BE AMENDED BEFORE THE TENTATIVE CAN BE APPROVED.
.
4. THE INTERSECTION OF MARKET CENTER DRIVE AND CHARTER
COLONY PARKWAY SHOULD BE SET UP IN ANTICIPATION OF FUTURE
SIGNALIZATION. THE LARGE AREA OF "FUTURE COMMERICAL" EAST
OF THE CENTERPOINTE TOWNES SITE MAY REQUIRE DUAL LEFT TURN
LANES INTO AND OUT OF MARKET CENTER DRIVE.
.
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: CENTERPOINTE TOWNHOMES
CASE NUMBER: 17TS0238
LATEST PLAN DATE: 07/20/2017
DEPT. REC'D. DATE: 07/27/2017
SUBMITTAL NUMBER: TWO
REVIEW DATE: 08/15/2017
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
.
THE PROPOSED AMENDMENTS TO THE CURRENT TRANSPORTATION
PHASING AND ACCESS PLANS ARE BEING REVIEWED BY COUNTY
STAFF. UNTIL THE AMENDMENTS ARE APPROVED, THE TENTATIVE
CANNOT BE APPROVED.
.
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: CENTERPOINTE TOWNHOMES
CASE NUMBER: 17TS0238
LATEST PLAN DATE: 09/15/2017
DEPT. REC'D. DATE: 09/20/2017
SUBMITTAL NUMBER: THREE
REVIEW DATE: 10/09/2017
RECOMMENDATION: APPROVED - WITH COMMENTS
TABLE REVIEW: YES
.
IN ACCORDANCE WITH THE TRANSPORTATION PHASING PLAN APPROVED
ON SEPTEMBER 6, 2017, THE IMPROVEMENTS LISTED ON SHEET C-2
SHALL BE COMPLETED PRIOR TO THE RECORDATION OF ANY LOTS/ 7
UNITS IN THE REFERENCED SECTIONS.
.
************************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------CENTERPOINTE TOWNHOMES
PLAN NUMBER---------------17TS0238
ORIGINAL PLAN DATE--------04/12/17
LATEST PLAN DATE----------04/12/17
DEPT. REC'D. DATE---------04/12/17
ACCEPTED FOR REVIEW-------04/24/17
SUBMITTAL NUMBER----------1
REVIEW DATE---------------05/23/17
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------NO
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS TO THE PLANNING DEPARTMENT FOR YOUR NEXT
REVIEW. PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH COMMENT
DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW COMMENT. INDICAT
PROVIDE A TRANSMITTAL LETTER TO DESCRIBE ANY CHANGES TO THE
PLANS NOT CAUSED BY THE STAFF REVIEW COMMENTS.
02. PUT THE CHESTERFIELD COUNTY PRELIMINARY PLAT NUMBER
17TS0238 IN THE LOWER RIGHT CORNER OF EACH SHEET.
03. R-TH STANDARDS REQUIRE 30% OF TOTAL SUBDIVISION ACREAGE
IN COMMON AREA AND 10% OF TOTAL SUBDIVISION AREA (MINIMUM
1.5 ACRES) PROVIDED FOR RECREATIONAL FACILITIES WITHIN THE
COMMON AREA. 19.1-111.A. 45.4% COMMON AREA HAS BEEN
PROVIDED, HOWEVER, ONLY 3.9% (1.45 ACRES) OF TOTAL AREA IS
DESIGNATED AS RECREATIONAL. PROVIDE ADDITIONAL ACTIVE OR
PASSIVE RECREATION AREAS TO MEET THE ORDINANCE REQUIREMENT.
04. ARBORWAY PLACE IN MILLPOINTE IS A DEAD-END STREET WIDE
ENOUGH FOR PARALLEL PARKING ON BOTH SIDES. THERE IS NO CUL-
DE-SAC BULB OR TURN-AROUND AREA PROVIDED WHICH IS
PROBLEMATIC. CONSIDER REDUCING LOT DEPTHS (LOTS 17 - 36)
AND COMMON AREAS ADJACENT TO THE ROAD IN ORDER TO PROVIDE A
ONE-WAY LOOP ROAD WITH PARKING ON ONE SIDE AND GREEN SPACE
IN THE CENTER.
05. EXTEND THE SIDEWALK ALONG THE FRONTAGE OF LOTS 22-31.
INCORPORATE INTO THE DESIGN OF A LOOP ROAD AS REFERENCED IN
THE PREVIOUS COMMENT.
06. DEAD END ALLEYS IN MILLPOINTE AT LOTS 17-36 CREATE A
HAZARD REQUIRING VEHICLES TO BACK OUT INTO THE STREET OR
PRIVATE DRIVEWAYS IN ORDER TO TURN AROUND. AVOID DEAD-END
ALLEY CONFIGURATIONS. 17-81.A.1
07. PROVIDE A LOCATION FOR CLUSTER BOX UNITS WITHIN OPEN
SPACE.
08. PROVIDE ON THE COVER SHEET THE LINEAR FOOTAGE OF BIKE
LANES PROVIDED WITH ALL NEW ROAD IMPROVEMENTS.
09. PRIOR TO RECORDATION, A COPY OF THE COVENANTS AND
ARTICLES OF INCORPORATION OF THE HOMEOWNERS' ASSOCIATION
SHALL BE PROVIDED.
************************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------CENTERPOINTE TOWNHOMES
PLAN NUMBER---------------17TS0238
ORIGINAL PLAN DATE--------04/12/17
LATEST PLAN DATE----------07/20/17
DEPT. REC'D. DATE---------07/21/17
ACCEPTED FOR REVIEW-------07/24/17
SUBMITTAL NUMBER----------2
REVIEW DATE---------------08/11/17
RECOMMENDATION------------REVISION REQUIRED
TABLE REVIEW--------------NO
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS TO THE PLANNING DEPARTMENT FOR YOUR NEXT
REVIEW. PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH COMMENT
DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW COMMENT.
INDICATE WHICH SHEETS SHOW THE REQUIRED CHANGES.
PROVIDE A TRANSMITTAL LETTER TO DESCRIBE ANY CHANGES TO
THE PLANS NOT CAUSED BY THE STAFF REVIEW COMMENTS.
02. THE CHESTERFIELD COUNTY PRELIMINARY PLAT NUMBER
17TS0238 IN THE LOWER RIGHT CORNER OF EACH SHEET IS CUT
OFF AND NOT FULLY LEGIBLE. ADJUST THE POSITION FOR
LEGIBILITY.
03. LABEL ALL AREAS OF OPEN SPACE AND COMMON AREA. COMMON
AREA IS DEFINED IN THE ORDINANCE AS LAND DEVELOPED AND
MAINTAINED FOR THE USE AND ENJOYMENT OF ALL RESIDENTS
AND/OR THE GENERAL PUBLIC. THE CLUBHOUSE AREA, THE 200'
SETBACK WITH WALKING TRAIL, MAIL KIOSK AREAS, AND BMP'S
SERVING AS AMENITIES WITH PEDESTRIAN ACCESS QUALIFY AS
COMMON AREA. SETBACKS AND SWM AREAS NOT SERVING AS
AMENITIES ARE CONSIDERED OPEN SPACE ONLY. VERIFY THE
CORRECT TABULATION OF THESE AREAS. THE COMMON AREA
REQUIREMENT FOR R-TH IS 30%.
04. THE EXISTING BMP 3 AND SURROUNDING AREA THAT IS
OUTSIDE OF THE PRELIMINARY PLAT BOUNDARY CANNOT BE LABELED
AND COUNTED AS OPEN SPACE. REMOVE THE OPEN SPACE
DESIGNATION IN THIS AREA.
05. A SANITARY SEWER LINE IS SHOWN RUNNING DOWN THE CENTER
OF THE MEDIAN IN THE PROPOSED COLONYHOUSE BOULEVARD. THIS
WOULD PRECLUDE THE PLANTING OF TREES WITHIN THE MEDIAN.
RELOCATE THE SEWER LINE INTO THE DRIVE LANE. LIGHTER LINES
TYING INTO SANITARY ARE ALSO SHOWN IN OTHER MEDIANS. WOULD
THESE CONFLICT WITH TREE PLANTINGS?
06. PRIOR TO RECORDATION, A COPY OF THE COVENANTS AND
ARTICLES OF INCORPORATION OF THE HOMEOWNERS' ASSOCIATION
SHALL BE PROVIDED.
************************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------CENTERPOINTE TOWNHOMES
PLAN NUMBER---------------17TS0238
ORIGINAL PLAN DATE--------04/12/17
LATEST PLAN DATE----------09/15/17
DEPT. REC'D. DATE---------09/15/17
ACCEPTED FOR REVIEW-------09/18/17
SUBMITTAL NUMBER----------3
REVIEW DATE---------------10/04/17
RECOMMENDATION------------REVISION REQUIRED
01. PUT A REVISION DATE ON THE RESUBMITTED PLANS. RESUBMIT
10 FULL SETS TO THE PLANNING DEPARTMENT FOR YOUR NEXT
REVIEW. PROVIDE A COMPLETE RESPONSE TO COMMENTS FOR ALL
DEPARTMENTS TO THE PLANNING DEPARTMENT. BELOW EACH COMMENT
DESCRIBE HOW YOU HAVE ADDRESSED EACH REVIEW COMMENT.
INDICATE WHICH SHEETS SHOW THE REQUIRED CHANGES.
PROVIDE A TRANSMITTAL LETTER TO DESCRIBE ANY CHANGES TO
THE PLANS NOT CAUSED BY THE STAFF REVIEW COMMENTS.
02. SPECIFY THE MATERIAL ON THE PLANS AND PROVIDE A
SECTION DETAIL FOR THE 5 FOOT TRAIL THAT PASSES THROUGH
THE COMMON AREAS.
************************************************************
REVIEW DEPARTMENT---------PLANNING
REVIEWER / PHONE #--------CHRIS HALE / (804) 717-6042
NAME OF PLAN--------------CENTERPOINTE TOWNHOMES
PLAN NUMBER---------------17TS0238
ORIGINAL PLAN DATE--------04/12/17
LATEST PLAN DATE----------11/16/17
DEPT. REC'D. DATE---------11/16/17
ACCEPTED FOR REVIEW-------11/16/17
SUBMITTAL NUMBER----------4 (TR)
REVIEW DATE---------------11/16/17
RECOMMENDATION------------APPROVED
1. PRIOR TO APPROVAL OF THE CONSTRUCTION PLAN, PLANS FOR A
SIGNALIZED PEDESTRIAN CROSSING AT CHARTER COLONY PARKWAY,
CONNECTING THE TWO SECTIONS OF CENTERPOINTE TOWNHOMES
(CENTERPOINTE TOWNES AND MILLPOINTE TOWNES) SHALL BE
SUBMITTED FOR REVIEW.(P)
2. PRIOR TO APPROVAL OF THE CONSTRUCTION PLAN, COLOR
ARCHITECTURAL ELEVATIONS OF ALL TYPICAL BUILDINGS PROPOSED
WITHIN THE DEVELOPMENT SHALL BE SUBMITTED FOR REVIEW.(P)
3. PRIOR TO APPROVAL OF THE CONSTRUCTION PLAN, A
PRIOR TO APPROVAL OF THE CONSTRUCTION PLAN, A
LANDSCAPE PLAN FOR STREET TREES, FOUNDATION
PLANTINGS, AND ANY PLANTINGS WITHIN COMMON AREAS
SHALL BE SUBMITTED FOR REVIEW. (P)
************************************************************
REVIEW DEPARTMENT: FIRE DEPARTMENT
REVIEWER / PHONE #: KIM LESTER / (804) 748-1489
PLAN NAME: CENTERPOINTE TOWNHOMES
PLAN NUMBER: 17TS0238
LATEST PLAN DATE: 4/12/17
REVIEW DATE: 5/10/17
DEPARTMENT RECEIVED DATE: 5/1/17
SUBMITTAL NUMBER: 1ST REVIEW
STATUS: NOT APPROVED
TABLE REVIEW: YES
.
THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE
REQUIREMENTS OF THIS SECTION AND SHALL EXTEND TO WITHIN 150
FEET OF ALL PORTIONS OF THE FACILITY AND ALL PORTIONS OF THE
EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURE
BY AN APPROVED ROUTE AROUND THE BUILDING. IFC 2012, 503.1.1
.
PROVIDE A COPY OF THE BUILDING ELEVATIONS. IFC APPENDIX,
D105, STATES WHERE THE VERTICAL DISTANCE BETWEEN THE GRADE
PLANE AND THE HIGHEST ROOF SURFACE EXCEEDS 30 FEET, APPROVED
AERIAL FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED. THE
AERIAL FIRE APPARATUS ACCESS ROAD SHALL BE A MINIMUM OF
TWENTY-SIX FEET UNOBSTRUCTED CLEAR WIDTH IN THE IMMEDIATE
VICINITY OF THE BUILDING. OVERHEAD OBSTRUCTIONS IN FORM OF
UTILITY OR POWER LINES SHALL NOT BE LOCATED WITHIN THE
AERIAL FIRE APPARATUS ACCESS ROADWAY. AT LEAST ONE AERIAL
FIRE APPARATUS ACCESS ROADWAY SHALL BE LOCATED A MINIMUM
OF FIFTEEN FEET AND A MAXIMUM OF THIRTY FEET FROM THE
BUILDING AND POSITIONED PARALLEL TO ONE ENTIRE SIDE OF THE
BUILDING. PLEASE SHOW THE DIMENSION ON THE PLAN FOR ALL
OF THE BUILDINGS. THE MEASUREMENT WILL BE FROM THE EDGE
OF PAVEMENT TO THE BUILDING.
.
WILL THERE BE ANY PARALLEL PARKING? IF SO, PLEASE SHOW IT ON
THE PLANS.
.
NOTE: COMPLIANCE WITH 17-76 OF THE SUBDIVISION ORDINANCE
IN THE CHESTERFIELD COUNTY CODE SHALL BE MAINTAINED
AT ALL TIMES.
.
NOTE: HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S) REQUIRED
AND THEIR LOCATION WILL BE EVALUATED AT THE TIME OF
CONSTRUCTION PLAN REVIEW.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT: FIRE DEPARTMENT
REVIEWER / PHONE #: KIM LESTER / (804) 748-1489
PLAN NAME: CENTERPOINTE TOWNHOMES
PLAN NUMBER: 17TS0238
LATEST PLAN DATE: 7/20/17
REVIEW DATE: 8/11/17
DEPARTMENT RECEIVED DATE: 7/27/17
SUBMITTAL NUMBER: 2ND REVIEW
STATUS: NOT APPROVED
TABLE REVIEW: YES
.
PROVIDE AN ADDITIONAL 1 FOOT OF CURBING ON THE MEDIAN
SIDE OF STREET. THAT WOULD LEAVE 10 FEET IN THE MEDIAN STRIP
.
THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE
REQUIREMENTS OF THIS SECTION AND SHALL EXTEND TO WITHIN 150
FEET OF ALL PORTIONS OF THE FACILITY AND ALL PORTIONS OF THE
EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURE
BY AN APPROVED ROUTE AROUND THE BUILDING. IFC 2012, 503.1.1
.
NOTE: COMPLIANCE WITH 17-76 OF THE SUBDIVISION ORDINANCE
IN THE CHESTERFIELD COUNTY CODE SHALL BE MAINTAINED
AT ALL TIMES.
.
NOTE: HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S) REQUIRED
AND THEIR LOCATION WILL BE EVALUATED AT THE TIME OF
CONSTRUCTION PLAN REVIEW. 0
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT: FIRE DEPARTMENT
REVIEWER / PHONE #: KIM LESTER / (804) 748-1489
PLAN NAME: CENTERPOINTE TOWNHOMES
PLAN NUMBER: 17TS0238
LATEST PLAN DATE: 9/15/17
REVIEW DATE: 9/26/17
DEPARTMENT RECEIVED DATE: 9/25/17
SUBMITTAL NUMBER: 3RD REVIEW
STATUS: APPROVED
TABLE REVIEW: YES
. 0
NOTE: THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE
REQUIREMENTS OF THIS SECTION AND SHALL EXTEND TO WITHIN 150
FEET OF ALL PORTIONS OF THE FACILITY AND ALL PORTIONS OF THE
EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURE
BY AN APPROVED ROUTE AROUND THE BUILDING. IFC 2012, 503.1.1
.
NOTE: COMPLIANCE WITH 17-76 OF THE SUBDIVISION ORDINANCE
IN THE CHESTERFIELD COUNTY CODE SHALL BE MAINTAINED
AT ALL TIMES.
.
NOTE: HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S) REQUIRED
AND THEIR LOCATION WILL BE EVALUATED AT THE TIME OF
CONSTRUCTION PLAN REVIEW.
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT: FIRE DEPARTMENT
REVIEWER / PHONE #: KIM LESTER / (804) 748-1489
PLAN NAME: CENTERPOINTE TOWNHOMES
PLAN NUMBER: 17TS0238
LATEST PLAN DATE: 11/16/17
REVIEW DATE: 11/16/17
DEPARTMENT RECEIVED DATE: 11/16/17
SUBMITTAL NUMBER: 4TH REVIEW
STATUS: APPROVED
TABLE REVIEW: YES
.
NOTE: THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE
REQUIREMENTS OF THIS SECTION AND SHALL EXTEND TO WITHIN 150
FEET OF ALL PORTIONS OF THE FACILITY AND ALL PORTIONS OF THE
EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURE
BY AN APPROVED ROUTE AROUND THE BUILDING. IFC 2012, 503.1.1
.
NOTE: COMPLIANCE WITH 17-76 OF THE SUBDIVISION ORDINANCE
IN THE CHESTERFIELD COUNTY CODE SHALL BE MAINTAINED
AT ALL TIMES.
.
NOTE: HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S) REQUIRED
AND THEIR LOCATION WILL BE EVALUATED AT THE TIME OF
CONSTRUCTION PLAN REVIEW.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
PLAN NAME: CENTERPOINTE TOWNHOMES
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: ROBERT W. BOSWELL - 748-1977
REVIEWER/PHONE: BECKY WARD - 748-1028
PLAN NUMBER: 17TS0238
ORIGINAL PLAN DATE: 4/12/17
LATEST SUBMISSION DATE: 4/20/17
REVIEW DATE: 5/22/17
SUBMITTAL NUMBER: 1
STATUS: REVISIONS REQUESTED
TABLE REVIEW: NO
.
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS
THE FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS
PERTAINING TO THE ABOVE REFERENCED TENTATIVE PLAT DATED
4/1217, RECEIVED BY THE PLANNING DEPARTMENT ON 4/12/17 AND
BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT ON 4/20/17.
.
PLEASE SPECIFY THE PRELIMINARY CASE NUMBER 17TS0238 ON SHEET
1 SITE SUMMARY.
.
PLEASE SPECIFY THE VSMP PART IIC 2009-2014 PERMIT NUMBER AND
2014-2019 PERMIT NUMBER ON SHEET 1.
.
PLEASE REFERENCE TO FEMA PANEL 106D DATED 12/18/12 ZONE D IN
THE GENERAL NOTES ON SHEET 1.
.
PLEASE INCLUDE ITEM C DRAINAGE AND EROSION CONTROL
CONDITIONS 1 - 4 FROM THE ZONING CASE 88SN0059 ON SHEET 1.
.
PLEASE PROVIDE A COPY OF RRPD STREET NAMES APPROVAL FOR
CHARTERMARK AND COLONYHOUSE.
.
THE BASE NAME ALTAVISTA IS A DUPLICATE. PLEASE USE A
DIFFERENT NAME FOR ONE OF THE TWO ROADS.
.
PLEASE LABEL BEAVER BROOK AND MILLPOINTE ROADS IN THE
ADJACENT CENTERPOINTE CROSSING SUBDIVISION ON SHEETS 1/2.
.
THE SPELLING OF ARBORWAY DOESN'T MATCH THE RRPD APPROVAL
LETTER SHOWING ABORWAY. PLEASE ADDRESS.
.
THERE DO NOT APPEAR TO BE ANY CLUSTER MAILBOX LOCATIONS
SHOWN IN THE PRELIMINARY PLAN. PLEASE ADDRESS.
.
WHY DO THE 100 YR FLOODPLAIN LIMITS STOP IN THE VICINITY OF
LOT 60 MILLPOINTE?
.
DEAD END ALLEYS ARE PROHIBITED UNLESS TURNAROUNDS PROVIDED
AT THE TERMINUS. PLEASE ADDRESS IN VICINITY OF LOTS 17-36
MILLPOINTE. SEC 17-81 ITEM A(1).
.
A BUMP OUT OR TURNAROUND SHOULD BE PROVIDED AT THE DEAD END
OF ARBORWAY PLACE.
.
WHY DOES THE RIGHT OF WAY LINE CROSS THE INTERSECTION OF
CHARTERMARK AND ARBORWAY?
.
ROAD IMPROVEMENTS ARE SHOWN BEYOND THE PROPOSED RIGHT OF WAY
EASTERN END OF ALTAVISTA AND NORTHERN END OF MARKET CENTER.
PLEASE EXPLAIN.
.
WILL A STREET SIGN BE PLACED WHERE THE FREE MARKET DRIVE
RIGHT OF WAY ENDS AND PRIVATE ROAD COBALT BEGINS?
.
IN LIEU OF AN "EXISTING SWM/BMP", THE FACILITY IS CURRENTLY
AN APPROVED SEDIMENT BASIN AS DEPICTED THE SECTION 2
CENTERPOINTE CROSSING CONSTRUCTION PLANS. CORRECT THE
LABELING.
.
PLEASE DIMENSION THE MOST RESTRICTIVE BUILDING SETBACK OFF
THE WETLANDS, 100YR FLOODPLAINS, ETC.
.
PLEASE PROVIDE THE FOLLOWING NOTE ON SHEET 1 UNDER NOTES AND
ON SHEET 8 PRELIMINARY CBPA PLAN, "ULTIMATE COMPLIANCE TO
CBPA REGULATION WILL BE ACHIEVED AT TIME OF CONSTRUCTION
PLAN APPROVAL FOR EACH SECTION. COMPLETE CBPA CALCULATIONS
WILL BE APPROVED WITH EACH CONSTRUCTION PLAN SUBMITTAL. ANY
DEFICIT OF WATER QUANTITY OR QUALITY AT TIME OF CONSTRUCTION
PLAN REVIEW MAY NECESSITATE ADDITIONAL SWM/BMP FACILITIES."
.
PLEASE SHOW/LABEL THE OFFSITE DRAINAGE EASEMENTS FROM THE
APPROVED OXYGEN PHASE II SITE PLAN IN THE VICINITY OF
SWM/BMP #1 AND THE PROPOSED TOWNHOMES.
.
.
.
PLEASE ADDRESS THE FOLLOWING CONCERNS REGARDING CBPA
COMPLIANCE ON SHEET 8:
.
A) PLEASE TITLE THE CBPA COMPLIANCE SHEET 8 AS
"PRELIMINARY".
B) THE 1.35 AC OFFSITE DA TO SWM/BMP 1 USED 16% IMPERVIOUS
AREA. PROVIDE SUPPORTING INFO THAT EXISTING CONDITIONS ARE
AT 16% IMP. APPEARS PREVIOUS APPROVAL OVERSIGHT.
C) THOUGH PREVIOUSLY APPROVED IN THE OXYGEN SITE PLANS,
BOTH BY-PASS AREAS 1 AND 2 HAVE PAVEMENT CROSSINGS WITHIN
THEM. ASSUMING 0% IMPERVIOUS IS NOT CORRECT. PLEASE REVISE
CALC'S ACCORDINGLY.
D) PLEASE PROVIDE TYPICAL TOWNHOME FOOTPRINTS OF
IMPERVIOUS AREAS THAT SHOULD SUPPORT THE ASSUMED 40% I USED
IN THE WORKSHEET A SUPPLEMENTAL CALC'S.
E) BY-PASS AREA 4 ASSUMES 0% I, HOWEVER, THE IDA INCLUDES
A PORTION OF CHARTERMARK DRIVE. PLEASE ADDRESS.
F) THE LATEST AERIAL SHOWS THE APPROXIMATE 3.75 AC OF THE
5.82 AC OFFSITE AS UNDEVELOPED WOODS. THE ACTUAL PERCENT
IMPERVIOUS SHOULD BE REFLECTED IN THE SUPPLEMENTAL CALC'S IN
LIEU OF THE 16% DEFAULT.
G) PLEASE SHOW THE CONTOURS WITH ELEVATIONS AND IMPERVIOUS
FOOTPRINT OF THE OFFSITE CHURCH PROPERTY IN THE VICINITY OF
THE 5.82 ACRES.
H) PLEASE REVISE THE SUPPLEMENTAL CALC'S AND THE WORKSHEET
A COMPUTATIONS BASED ON THE ABOVE CONCERNS.
I) PLEASE CLARIFY WHY THE 50' VEGETATIVE PERIMETER YARD
SETBACK IS SHOWN WITHIN THE FUTURE COMMERCIAL TRACT FOR
SWM/BMP 2.
.
ALL STEPS IN THE WORKSHEET A CALCULATIONS NEED TO BE
REVISED FOR REVIEW AND/OR APPROVAL. PLEASE ADDRESS.
.
PRIOR TO PRELIMINARY PLAT APPROVAL, THE ENCLOSED
ACKNOWLEDGEMENT FORM SIGNED BY THE DEVELOPER REGARDING
MASONRY EMBELLISHMENTS WITHIN THE VDOT CLEAR ZONE MUST BE
RECEIVED.
.
TENTATIVE CONDITIONS COULD INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
1. THE BMP'S INITIAL, PREDOMINANT WATER-QUALITY FUNCTION
SHALL BE SEDIMENT CONTROL; THE IMPLEMENTATION OF WHICH
SHALL BE COORDINATED WITH THE FIRST PORTION OF THE PROJECT
THAT DRAINS IN ITS DIRECTION.
.
2. ROAD RIGHT-OF-WAY SHALL BE WIDE ENOUGH TO ENCOMPASS
THE PEDESTRIAN-ACCESS FACILITIES IF THE SIDEWALKS MEET STATE
CRITERIA.
.
3. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE SPILLWAY STRUCTURE FOR THE WET
POND(S) SHALL BE A CONCRETE WEIR.
.
4. THE DESIGN AND CONSTRUCTION OF THE SWM/BMP THAT WILL BE
A COUNTY MAINTAINED FACILITY SHALL BE SUBJECT TO DOCUMENTED
GEOTECHNICAL APPROVAL. THE SERVICES THAT MUST BE PROVIDED
BY THE GEOTECHNICAL ENGINEER SHALL INCLUDE FULL-TIME
GEOTECHNICAL INSPECTION PAID FOR BY THE DEVELOPER. THAT
FULL-TIME INSPECTION SHALL INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
A. PARTICIPATION/INPUT INTO THE DESIGN PROCESS AS NECESSARY
TO FACILITATE THE APPROVAL PROCESS OF THE INDEPENDENT
GEOTECHNICAL CONSULTANT. OBSERVATION, TESTING AND
DOCUMENTATION OF:
.
I. SUITABLE SUB-GRADES TO RECEIVE COMPACTED STRUCTURAL
FILL FOR EARTH DAM CONSTRUCTION.
.
II. THE CUT-OFF TRENCH, SPILLWAY PIPE, DRAINAGE BLANKET,
RISER STRUCTURE, AND CONCRETE CHUTE SPILLWAY SUB-GRADES AS
APPLICABLE TO EVALUATE WHETHER SUITABLE SOIL IS PRESENT AT
BEARING GRADE TO VERIFY PROPER INSTALLATION.
.
III. REINFORCING STEEL, IF REQUIRED, TO EVALUATE ITS
CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS.
.
5. THE FACILITY CERTIFICATION PROCESS SHALL BE PERFORMED
BY
AN ENGINEERING/SURVEYING PROFESSIONAL APPROVED BY THE
COUNTY AT THE OWNER'S EXPENSE.
.
6. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
.
7. PRIOR TO RECORDATION, A COPY OF THE COVENANTS AND
ARTICLES OF INCORPORATION OF THE HOMEOWNERS' ASSOCIATION
SHALL BE PROVIDED TO THE ENVIRONMENTAL ENGINEERING
DEPARTMENT FOR APPROVAL. THE ENVIRONMENTAL ENGINEERING
DEPARTMENT WILL DETERMINE WHETHER THE SUBDIVISION HAS
BEEN PROVIDED WITH THE INFORMATION TO DEVELOP AND
IMPLEMENT A FERTILIZATION/LAWN CARE PROGRAM TO MINIMIZE
PHOSPHOROUS RUNOFF. THE REQUIREMENTS OF THE PROGRAM
SHALL BECOME A PART OF THE COVENANTS FOR THE PROJECT
AFFECTING ALL PROPERTIES WITHIN THE DEVELOPMENT.
.
8. SPECIAL UPPER SWIFT CREEK WATERSHED END TREATMENT
AS DIRECTED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT
WILL BE PLACED IN THE VICINITY OF THE TERMINUS OF MANMADE
STORM DRAINAGE OUTFALLS.
.
9. THE ENVIRONMENTAL ENGINEERING DEPARTMENT MAY
IMPOSE A MORE RIGOROUS EROSION AND SEDIMENT CONTROL
PROGRAM THAN THAT WHICH IS PROVIDED BY MINIMUM
STANDARDS FOUND IN THE VIRGINIA EROSION AND SEDIMENT
CONTROL HANDBOOK.
.
10. AS DIRECTED BY ENVIRONMENTAL ENGINEERING, A DAM FAILURE
ANALYSIS SHALL BE PERFORMED BASED ON AN OVER-TOPPING BREACH
OF THE DAM EMBANKMENT DURING A 100 YEAR STORM EVENT.
EXISTING OR PROPOSED HOMES SHALL BE OUTSIDE THE DAM FAILURE
LIMITS. VIRGINIA DAM SAFETY ACT CRITERIA MAY TAKE
PRECEDENCE.
.
11. GRADING ON INDIVIDUAL LOTS WILL BE PROVIDED SO THAT
EACH PROPERTY WILL HAVE A SURFACE DRAINAGE CONFIGURATION
FUNCTIONING INDEPENDENTLY FROM ITS ADJACENT LOTS.
.
12. ROOF GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED ON THE
DWELLINGS. ALL ROOF DRAINAGE LEADERS WILL BE TIED DIRECTLY
INTO MINIMUM 12" ONSITE STORM SEWERS OR OTHER STABLE
CONVEYANCE SYSTEMS DEEMED APPROPRIATE BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
13. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE ENVIRONMENTAL
ENGINEERING DEPARTMENT MUST HAVE RECEIVED
DOCUMENTATION THAT THE SUB-DIVIDER OR HIS REPRESENTATIVE
HAS NOTIFIED CERTAIN PROPERTY OWNERS DETERMINED BY THE
DEPARTMENT OF THE PROPOSED ADJACENT CONSTRUCTION.
.
.
14. THE ALLEYS SHALL FUNCTION AS STORM WATER CONVEYANCE
SYSTEMS. THE ALLEY TYPICAL SECTION CAN BE AN INVERTED CROWN
WITH A 1-INCH PER FOOT CROSS SLOPE SUCH THAT THERE WILL BE A
MINIMUM 6-INCHES OF ELEVATION DIFFERENCE BETWEEN THE EDGE OF
PAVEMENT AND CENTERLINE IF THE ALLEY WIDTH WERE TO BE
12-FEET OR CURB AND GUTTER MAY BE USED.
.
15. THE 100-YEAR STORM SHALL NOT EXCEED THE CONTAINMENT
DEPTH OF THE ALLEYS. ALLEY PAVEMENT DESIGN SHALL BE
EQUIVALENT TO THAT REQUIRED FOR CHESTERFIELD COUNTY PUBLIC
ROADS.
.
16. STORM WATER IN THE ALLEYS SHALL BE PICKED UP BY DI-1
GRATED INLETS INTO WHICH THE INVERTED CROWNS WOULD FLOW
AND BE DISCHARGED VIA STORM SEWER OR OTHER METHOD
APPROVED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
17. ALLEY PAVEMENT SHALL BE SIGNED "PRIVATE MAINTENANCE"
AND LANGUAGE APPROVED AT TIME OF CONSTRUCTION PLAN APPROVAL.
.
18. UNLESS OTHERWISE APPROVED, THE RELEASE RATE FROM THE
SWM/BMP FACILITIES DURING THE 10 YEAR POST DEVELOPED STORM
EVENT SHALL NOT EXCEED THE PREDEVELOPED 2 YEAR STORM EVENT.
.
19. PLEASE PROVIDE A WRITTEN RESPONSE IN THE MARGIN OF A
COPY OF THESE REVIEW COMMENTS WITH YOUR NEXT PLAN SUBMITTAL.
.
NOTES:
.
PLEASE NOTE ADDITIONAL ON-SITE DETENTION MAY BE REQUIRED
DURING DETAILED REVIEW OF THE CONSTRUCTION PLAN TO SATISFY
THE PART IIB OR PART IIC FLOODING CRITERIA OF THE VIRGINIA
STORMWATER MANAGEMENT PROGRAM REGULATIONS. THIS MAY RESULT
IN A MAJOR REVISION TO THE PRELIMINARY PLAT AND/OR THE LOSS
OF LOTS TO ACCOMMODATE LARGER AND/OR ADDITIONAL STORMWATER
MANAGEMENT FACILITIES.
.
.
.
(PLEASE PLACE ON DEVELOPER LETTERHEAD)
.
(DATE)
.
KIRKLAND A. TURNER, DIRECTOR
CHESTERFIELD COUNTY PLANNING DEPARTMENT
P. O. BOX 40
CHESTERFIELD, VIRGINIA 23832
.
RE: ENTRANCE EMBELLISHMENTS (____________ TENTATIVE)
.
DEAR MR. TURNER:
.
AS DEVELOPER OF THE PROPOSED __________________
SUBDIVISION, I AM AWARE THAT THE FOLLOWING NOTE IS NOW
REQUIRED NOT ONLY ON TENTATIVES BUT ALSO ON RECORD PLATS.
.
"NO STRUCTURE EMBELLISHMENTS WILL BE ALLOWED ON VDOT
RIGHT-OF-WAY WITHOUT THE COMMITMENT OF, OR THE ISSUANCE OF,
A VDOT LAND USE PERMIT. WITHIN THE 10' CLEAR ZONE
(MEASURED FROM THE EDGE OF THE ROADWAY'S PAVEMENT OUT
10'), NO STRUCTURE EMBELLISHMENT WILL BE PERMITTED THAT IS
CLOSER THAN 3' FROM THE EDGE OF PAVEMENT OF THE PUBLIC
STREET OR HIGHER THAN 6" ABOVE THE SURFACE OF THE DRIVE."
.
I WILL DO ALL POSSIBLE TO PROVIDE THE CORRECT INFORMATION
FOR
BUILDERS OR CITIZENS CONSTRUCTING ENTRANCE EMBELLISHMENTS.
I AM ALSO AWARE THAT, PRIOR TO STATE ACCEPTANCE OF THE
ROADS, I AM RESPONSIBLE FOR REMOVING EMBELLISHMENTS THAT
DO NOT MEET STATE STANDARDS.
.
SINCERELY,
.
DEVELOPER NAME (PRINTED)
.
DEVELOPER SIGNATURE
(DATE)
.
*******************************************
PLAN NAME: CENTERPOINTE TOWNHOMES
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: ROBERT W. BOSWELL - 748-1977
PLAN NUMBER: 17TS0238
ORIGINAL PLAN DATE: 4/12/17
LATEST SUBMISSION DATE: 4/20/17
LATEST SUBMISSION DATE: 7/24/17
REVIEW DATE: 8/14/17
SUBMITTAL NUMBER: 2
STATUS: REVISIONS REQUESTED
TABLE REVIEW: NO
.
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS
THE FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS
PERTAINING TO THE ABOVE REFERENCED TENTATIVE PLAT DATED
7/20/17, RECEIVED BY THE PLANNING DEPARTMENT ON 7/24/17 AND
BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT ON 7/25/17.
.
PLEASE SPECIFY THE VSMP PART IIC 2009-2014 PERMIT NUMBER ON
SHEET 1.
.
SHOULD THE BOUNDARY OF THE PRELIMINARY BE ADJUSTED TO
COINCIDE WITH THE RIGHT-OF-WAY AT THE END OF CANTINA LANE
VICINITY OF LOT 67?
.
LOT NUMBERING AT CENTERPOINTE TOWNES HAS BEEN OMITTED ON
SHEET 5.
.
PLEASE USE THE SAME WETLANDS AND IMPACTED WETLANDS
DEPICTIONS AS SHOWN ON SHEET 5 ON SHEETS 3/4.
.
CONFIRM IF VDOT WILL ALLOW VARIABLE WIDTH RIGHT-OF-WAY
ENCLOSING THE BUMP OUT AREA FOR THE CMB ON BEAVER BROOK
SHEET 4.
.
PLEASE REVISE THE TYPICAL ALLEY SECTION SHOWN ON SHEET 7 AS
IT DOES NOT REFLECT THE INVERTED CROWN SECTION FUNCTIONING
AS A STORM WATER CONVEYANCE SYSTEM. AN EXAMPLE DETAIL CAN
BE PROVIDED WHICH INCLUDES THE DI -1 INLETS.
.
STEP 4 IN THE WORKSHEET A CALCULATIONS NEED TO BE REVISED
FOR BMP 3 5.82 ACRES AS THE LOADING FACTOR IS 0.64 IN LIEU
OF 0.62. PLEASE ADDRESS.
.
PLEASE PROVIDE A WRITTEN RESPONSE TO EACH OF THE ABOVE
COMMENTS WITH NEXT PLAN SUBMITTAL.
.
.
TENTATIVE CONDITIONS COULD INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
1. THE BMP'S INITIAL, PREDOMINANT WATER-QUALITY FUNCTION
SHALL BE SEDIMENT CONTROL; THE IMPLEMENTATION OF WHICH
SHALL BE COORDINATED WITH THE FIRST PORTION OF THE PROJECT
THAT DRAINS IN ITS DIRECTION.
.
2. ROAD RIGHT-OF-WAY SHALL BE WIDE ENOUGH TO ENCOMPASS
THE PEDESTRIAN-ACCESS FACILITIES IF THE SIDEWALKS MEET STATE
CRITERIA.
.
3. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE SPILLWAY STRUCTURE FOR THE WET
POND(S) SHALL BE A CONCRETE WEIR.
.
4. THE DESIGN AND CONSTRUCTION OF THE SWM/BMP THAT WILL BE
A COUNTY MAINTAINED FACILITY SHALL BE SUBJECT TO DOCUMENTED
GEOTECHNICAL APPROVAL. THE SERVICES THAT MUST BE PROVIDED
BY THE GEOTECHNICAL ENGINEER SHALL INCLUDE FULL-TIME
GEOTECHNICAL INSPECTION PAID FOR BY THE DEVELOPER. THAT
FULL-TIME INSPECTION SHALL INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
A. PARTICIPATION/INPUT INTO THE DESIGN PROCESS AS NECESSARY
TO FACILITATE THE APPROVAL PROCESS OF THE INDEPENDENT
GEOTECHNICAL CONSULTANT. OBSERVATION, TESTING AND
DOCUMENTATION OF:
.
I. SUITABLE SUB-GRADES TO RECEIVE COMPACTED STRUCTURAL
FILL FOR EARTH DAM CONSTRUCTION.
.
II. THE CUT-OFF TRENCH, SPILLWAY PIPE, DRAINAGE BLANKET,
RISER STRUCTURE, AND CONCRETE CHUTE SPILLWAY SUB-GRADES AS
APPLICABLE TO EVALUATE WHETHER SUITABLE SOIL IS PRESENT AT
BEARING GRADE TO VERIFY PROPER INSTALLATION.
.
III. REINFORCING STEEL, IF REQUIRED, TO EVALUATE ITS
CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS.
.
5. THE FACILITY CERTIFICATION PROCESS SHALL BE PERFORMED
BY
AN ENGINEERING/SURVEYING PROFESSIONAL APPROVED BY THE
COUNTY AT THE OWNER'S EXPENSE.
.
6. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
.
7. PRIOR TO RECORDATION, A COPY OF THE COVENANTS AND
ARTICLES OF INCORPORATION OF THE HOMEOWNERS' ASSOCIATION
SHALL BE PROVIDED TO THE ENVIRONMENTAL ENGINEERING
DEPARTMENT FOR APPROVAL. THE ENVIRONMENTAL ENGINEERING
DEPARTMENT WILL DETERMINE WHETHER THE SUBDIVISION HAS
BEEN PROVIDED WITH THE INFORMATION TO DEVELOP AND
IMPLEMENT A FERTILIZATION/LAWN CARE PROGRAM TO MINIMIZE
PHOSPHOROUS RUNOFF. THE REQUIREMENTS OF THE PROGRAM
SHALL BECOME A PART OF THE COVENANTS FOR THE PROJECT
AFFECTING ALL PROPERTIES WITHIN THE DEVELOPMENT.
.
8. SPECIAL UPPER SWIFT CREEK WATERSHED END TREATMENT
AS DIRECTED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT
WILL BE PLACED IN THE VICINITY OF THE TERMINUS OF MANMADE
STORM DRAINAGE OUTFALLS.
.
9. THE ENVIRONMENTAL ENGINEERING DEPARTMENT MAY
IMPOSE A MORE RIGOROUS EROSION AND SEDIMENT CONTROL
PROGRAM THAN THAT WHICH IS PROVIDED BY MINIMUM
STANDARDS FOUND IN THE VIRGINIA EROSION AND SEDIMENT
CONTROL HANDBOOK.
.
10. AS DIRECTED BY ENVIRONMENTAL ENGINEERING, A DAM FAILURE
ANALYSIS SHALL BE PERFORMED BASED ON AN OVER-TOPPING BREACH
OF THE DAM EMBANKMENT DURING A 100 YEAR STORM EVENT.
EXISTING OR PROPOSED HOMES SHALL BE OUTSIDE THE DAM FAILURE
LIMITS. VIRGINIA DAM SAFETY ACT CRITERIA MAY TAKE
PRECEDENCE.
.
11. GRADING ON INDIVIDUAL LOTS WILL BE PROVIDED SO THAT
EACH PROPERTY WILL HAVE A SURFACE DRAINAGE CONFIGURATION
FUNCTIONING INDEPENDENTLY FROM ITS ADJACENT LOTS.
.
12. ROOF GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED ON THE
DWELLINGS. ALL ROOF DRAINAGE LEADERS WILL BE TIED DIRECTLY
INTO MINIMUM 12" ONSITE STORM SEWERS OR OTHER STABLE
CONVEYANCE SYSTEMS DEEMED APPROPRIATE BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
13. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE ENVIRONMENTAL
ENGINEERING DEPARTMENT MUST HAVE RECEIVED
DOCUMENTATION THAT THE SUB-DIVIDER OR HIS REPRESENTATIVE
HAS NOTIFIED CERTAIN PROPERTY OWNERS DETERMINED BY THE
DEPARTMENT OF THE PROPOSED ADJACENT CONSTRUCTION.
.
.
14. THE ALLEYS SHALL FUNCTION AS STORM WATER CONVEYANCE
SYSTEMS. THE ALLEY TYPICAL SECTION CAN BE AN INVERTED CROWN
WITH A 1-INCH PER FOOT CROSS SLOPE SUCH THAT THERE WILL BE A
MINIMUM 6-INCHES OF ELEVATION DIFFERENCE BETWEEN THE EDGE OF
PAVEMENT AND CENTERLINE IF THE ALLEY WIDTH WERE TO BE
12-FEET OR CURB AND GUTTER MAY BE USED.
.
15. THE 100-YEAR STORM SHALL NOT EXCEED THE CONTAINMENT
DEPTH OF THE ALLEYS. ALLEY PAVEMENT DESIGN SHALL BE
EQUIVALENT TO THAT REQUIRED FOR CHESTERFIELD COUNTY PUBLIC
ROADS.
.
16. STORM WATER IN THE ALLEYS SHALL BE PICKED UP BY DI-1
GRATED INLETS INTO WHICH THE INVERTED CROWNS WOULD FLOW
AND BE DISCHARGED VIA STORM SEWER OR OTHER METHOD
APPROVED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
17. ALLEY PAVEMENT SHALL BE SIGNED "PRIVATE MAINTENANCE"
AND LANGUAGE APPROVED AT TIME OF CONSTRUCTION PLAN APPROVAL.
.
18. UNLESS OTHERWISE APPROVED, THE RELEASE RATE FROM THE
SWM/BMP FACILITIES DURING THE 10 YEAR POST DEVELOPED STORM
EVENT SHALL NOT EXCEED THE PREDEVELOPED 2 YEAR STORM EVENT.
.
19. PRIOR TO APPROVAL OF ANY CONSTRUCTION PLAN WITHIN
CENTERPOINTE TOWNHOMES OR THE ADJACENT PARCEL 1B FUTURE
COMMERCIAL, THE 50' SWM/BMP EASEMENT AS DEPICTED IN THE
PRELIMINARY PLAT ON PARCEL 1B MUST BE RECORDED WITH DB-PG
PROVIDED TO THIS OFFICE.
.
.
.
NOTES:
.
PLEASE NOTE ADDITIONAL ON-SITE DETENTION MAY BE REQUIRED
DURING DETAILED REVIEW OF THE CONSTRUCTION PLAN TO SATISFY
THE PART IIB OR PART IIC FLOODING CRITERIA OF THE VIRGINIA
STORMWATER MANAGEMENT PROGRAM REGULATIONS. THIS MAY RESULT
IN A MAJOR REVISION TO THE PRELIMINARY PLAT AND/OR THE LOSS
OF LOTS TO ACCOMMODATE LARGER AND/OR ADDITIONAL STORMWATER
MANAGEMENT FACILITIES.
.
PLAN NAME: CENTERPOINTE TOWNHOMES
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: ROBERT W. BOSWELL - 748-1977
PLAN NUMBER: 17TS0238
ORIGINAL PLAN DATE: 4/12/17
LATEST SUBMISSION DATE: 9/15/17
REVIEW DATE: 10/5/17
SUBMITTAL NUMBER: 3
STATUS: REVISIONS REQUESTED
TABLE REVIEW: YES
.
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS
THE FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS
PERTAINING TO THE ABOVE REFERENCED TENTATIVE PLAT DATED
9/15/17, RECEIVED BY THE PLANNING DEPARTMENT ON 9/15/17 AND
BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT ON 9/21/17.
.
AS DISCUSSED ON OCTOBER 5, 2017, PLEASE ADJUST THE LIMITS OF
THE RIGHT OF WAY TO COINCIDE WITH THE BOUNDARY OF THE
PRELIMINARY AT CANTINA LANE ON ALL APPLICABLE SHEETS.
.
PLEASE PROVIDE A WRITTEN RESPONSE TO EACH OF THE ABOVE
COMMENTS WITH NEXT PLAN SUBMITTAL.
.
TENTATIVE CONDITIONS COULD INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
1. THE BMP'S INITIAL, PREDOMINANT WATER-QUALITY FUNCTION
SHALL BE SEDIMENT CONTROL; THE IMPLEMENTATION OF WHICH
SHALL BE COORDINATED WITH THE FIRST PORTION OF THE PROJECT
THAT DRAINS IN ITS DIRECTION.
.
2. ROAD RIGHT-OF-WAY SHALL BE WIDE ENOUGH TO ENCOMPASS
THE PEDESTRIAN-ACCESS FACILITIES IF THE SIDEWALKS MEET STATE
CRITERIA.
.
3. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE SPILLWAY STRUCTURE FOR THE WET
POND(S) SHALL BE A CONCRETE WEIR.
.
4. THE DESIGN AND CONSTRUCTION OF THE SWM/BMP THAT WILL BE
A COUNTY MAINTAINED FACILITY SHALL BE SUBJECT TO DOCUMENTED
GEOTECHNICAL APPROVAL. THE SERVICES THAT MUST BE PROVIDED
BY THE GEOTECHNICAL ENGINEER SHALL INCLUDE FULL-TIME
GEOTECHNICAL INSPECTION PAID FOR BY THE DEVELOPER. THAT
FULL-TIME INSPECTION SHALL INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
A. PARTICIPATION/INPUT INTO THE DESIGN PROCESS AS NECESSARY
TO FACILITATE THE APPROVAL PROCESS OF THE INDEPENDENT
GEOTECHNICAL CONSULTANT. OBSERVATION, TESTING AND
DOCUMENTATION OF:
.
I. SUITABLE SUB-GRADES TO RECEIVE COMPACTED STRUCTURAL
FILL FOR EARTH DAM CONSTRUCTION.
.
II. THE CUT-OFF TRENCH, SPILLWAY PIPE, DRAINAGE BLANKET,
RISER STRUCTURE, AND CONCRETE CHUTE SPILLWAY SUB-GRADES AS
APPLICABLE TO EVALUATE WHETHER SUITABLE SOIL IS PRESENT AT
BEARING GRADE TO VERIFY PROPER INSTALLATION.
.
III. REINFORCING STEEL, IF REQUIRED, TO EVALUATE ITS
CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS.
.
5. THE FACILITY CERTIFICATION PROCESS SHALL BE PERFORMED
BY
AN ENGINEERING/SURVEYING PROFESSIONAL APPROVED BY THE
COUNTY AT THE OWNER'S EXPENSE.
.
6. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
.
7. PRIOR TO RECORDATION, A COPY OF THE COVENANTS AND
ARTICLES OF INCORPORATION OF THE HOMEOWNERS' ASSOCIATION
SHALL BE PROVIDED TO THE ENVIRONMENTAL ENGINEERING
DEPARTMENT FOR APPROVAL. THE ENVIRONMENTAL ENGINEERING
DEPARTMENT WILL DETERMINE WHETHER THE SUBDIVISION HAS
BEEN PROVIDED WITH THE INFORMATION TO DEVELOP AND
IMPLEMENT A FERTILIZATION/LAWN CARE PROGRAM TO MINIMIZE
PHOSPHOROUS RUNOFF. THE REQUIREMENTS OF THE PROGRAM
SHALL BECOME A PART OF THE COVENANTS FOR THE PROJECT
AFFECTING ALL PROPERTIES WITHIN THE DEVELOPMENT.
.
8. SPECIAL UPPER SWIFT CREEK WATERSHED END TREATMENT
AS DIRECTED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT
WILL BE PLACED IN THE VICINITY OF THE TERMINUS OF MANMADE
STORM DRAINAGE OUTFALLS.
.
9. THE ENVIRONMENTAL ENGINEERING DEPARTMENT MAY
IMPOSE A MORE RIGOROUS EROSION AND SEDIMENT CONTROL
PROGRAM THAN THAT WHICH IS PROVIDED BY MINIMUM
STANDARDS FOUND IN THE VIRGINIA EROSION AND SEDIMENT
CONTROL HANDBOOK.
.
10. AS DIRECTED BY ENVIRONMENTAL ENGINEERING, A DAM FAILURE
ANALYSIS SHALL BE PERFORMED BASED ON AN OVER-TOPPING BREACH
OF THE DAM EMBANKMENT DURING A 100 YEAR STORM EVENT.
EXISTING OR PROPOSED HOMES SHALL BE OUTSIDE THE DAM FAILURE
LIMITS. VIRGINIA DAM SAFETY ACT CRITERIA MAY TAKE
PRECEDENCE.
.
11. GRADING ON INDIVIDUAL LOTS WILL BE PROVIDED SO THAT
EACH PROPERTY WILL HAVE A SURFACE DRAINAGE CONFIGURATION
FUNCTIONING INDEPENDENTLY FROM ITS ADJACENT LOTS.
.
12. ROOF GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED ON THE
DWELLINGS. ALL ROOF DRAINAGE LEADERS WILL BE TIED DIRECTLY
INTO MINIMUM 12" ONSITE STORM SEWERS OR OTHER STABLE
CONVEYANCE SYSTEMS DEEMED APPROPRIATE BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
13. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE ENVIRONMENTAL
ENGINEERING DEPARTMENT MUST HAVE RECEIVED
DOCUMENTATION THAT THE SUB-DIVIDER OR HIS REPRESENTATIVE
HAS NOTIFIED CERTAIN PROPERTY OWNERS DETERMINED BY THE
DEPARTMENT OF THE PROPOSED ADJACENT CONSTRUCTION.
.
.
14. THE ALLEYS SHALL FUNCTION AS STORM WATER CONVEYANCE
SYSTEMS. THE ALLEY TYPICAL SECTION CAN BE AN INVERTED CROWN
WITH A 1-INCH PER FOOT CROSS SLOPE SUCH THAT THERE WILL BE A
MINIMUM 6-INCHES OF ELEVATION DIFFERENCE BETWEEN THE EDGE OF
PAVEMENT AND CENTERLINE IF THE ALLEY WIDTH WERE TO BE
12-FEET OR CURB AND GUTTER MAY BE USED.
.
15. THE 100-YEAR STORM SHALL NOT EXCEED THE CONTAINMENT
DEPTH OF THE ALLEYS. ALLEY PAVEMENT DESIGN SHALL BE
EQUIVALENT TO THAT REQUIRED FOR CHESTERFIELD COUNTY PUBLIC
ROADS.
.
16. STORM WATER IN THE ALLEYS SHALL BE PICKED UP BY DI-1
GRATED INLETS INTO WHICH THE INVERTED CROWNS WOULD FLOW
AND BE DISCHARGED VIA STORM SEWER OR OTHER METHOD
APPROVED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
17. ALLEY PAVEMENT SHALL BE SIGNED "PRIVATE MAINTENANCE"
AND LANGUAGE APPROVED AT TIME OF CONSTRUCTION PLAN APPROVAL.
.
18. UNLESS OTHERWISE APPROVED, THE RELEASE RATE FROM THE
SWM/BMP FACILITIES DURING THE 10 YEAR POST DEVELOPED STORM
EVENT SHALL NOT EXCEED THE PREDEVELOPED 2 YEAR STORM EVENT.
.
19. PRIOR TO APPROVAL OF ANY CONSTRUCTION PLAN WITHIN
CENTERPOINTE TOWNHOMES OR THE ADJACENT PARCEL 1B FUTURE
COMMERCIAL, THE 50' SWM/BMP EASEMENT AS DEPICTED IN THE
PRELIMINARY PLAT ON PARCEL 1B MUST BE RECORDED WITH DB-PG
PROVIDED TO THIS OFFICE.
.
.
.
NOTES:
.
PLEASE NOTE ADDITIONAL ON-SITE DETENTION MAY BE REQUIRED
DURING DETAILED REVIEW OF THE CONSTRUCTION PLAN TO SATISFY
THE PART IIB OR PART IIC FLOODING CRITERIA OF THE VIRGINIA
STORMWATER MANAGEMENT PROGRAM REGULATIONS. THIS MAY RESULT
IN A MAJOR REVISION TO THE PRELIMINARY PLAT AND/OR THE LOSS
OF LOTS TO ACCOMMODATE LARGER AND/OR ADDITIONAL STORMWATER
MANAGEMENT FACILITIES.
.
PLAN NAME: CENTERPOINTE TOWNHOMES
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: ROBERT W. BOSWELL - 748-1977
PLAN NUMBER: 17TS0238
ORIGINAL PLAN DATE: 4/12/17
LATEST SUBMISSION DATE: 11/16/17
REVIEW DATE: 11/16/17
SUBMITTAL NUMBER: 4
STATUS: APPROVED
TABLE REVIEW: N/A
.
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS
THE FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS
PERTAINING TO THE ABOVE REFERENCED TENTATIVE PLAT DATED
11/16/17, RECEIVED BY THE PLANNING DEPARTMENT ON 11/16/17
AND BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT ON 11/16/17.
.
TENTATIVE CONDITIONS COULD INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
1. THE BMP'S INITIAL, PREDOMINANT WATER-QUALITY FUNCTION
SHALL BE SEDIMENT CONTROL; THE IMPLEMENTATION OF WHICH
SHALL BE COORDINATED WITH THE FIRST PORTION OF THE PROJECT
THAT DRAINS IN ITS DIRECTION.
.
2. ROAD RIGHT-OF-WAY SHALL BE WIDE ENOUGH TO ENCOMPASS
THE PEDESTRIAN-ACCESS FACILITIES IF THE SIDEWALKS MEET STATE
CRITERIA.
.
3. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE SPILLWAY STRUCTURE FOR THE WET
POND(S) SHALL BE A CONCRETE WEIR.
.
4. THE DESIGN AND CONSTRUCTION OF THE SWM/BMP THAT WILL BE
A COUNTY MAINTAINED FACILITY SHALL BE SUBJECT TO DOCUMENTED
GEOTECHNICAL APPROVAL. THE SERVICES THAT MUST BE PROVIDED
BY THE GEOTECHNICAL ENGINEER SHALL INCLUDE FULL-TIME
GEOTECHNICAL INSPECTION PAID FOR BY THE DEVELOPER. THAT
FULL-TIME INSPECTION SHALL INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
.
A. PARTICIPATION/INPUT INTO THE DESIGN PROCESS AS NECESSARY
TO FACILITATE THE APPROVAL PROCESS OF THE INDEPENDENT
GEOTECHNICAL CONSULTANT. OBSERVATION, TESTING AND
DOCUMENTATION OF:
.
I. SUITABLE SUB-GRADES TO RECEIVE COMPACTED STRUCTURAL
FILL FOR EARTH DAM CONSTRUCTION.
.
II. THE CUT-OFF TRENCH, SPILLWAY PIPE, DRAINAGE BLANKET,
RISER STRUCTURE, AND CONCRETE CHUTE SPILLWAY SUB-GRADES AS
APPLICABLE TO EVALUATE WHETHER SUITABLE SOIL IS PRESENT AT
BEARING GRADE TO VERIFY PROPER INSTALLATION.
.
III. REINFORCING STEEL, IF REQUIRED, TO EVALUATE ITS
CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS.
.
5. THE FACILITY CERTIFICATION PROCESS SHALL BE PERFORMED
BY
AN ENGINEERING/SURVEYING PROFESSIONAL APPROVED BY THE
COUNTY AT THE OWNER'S EXPENSE.
.
6. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
.
7. PRIOR TO RECORDATION, A COPY OF THE COVENANTS AND
ARTICLES OF INCORPORATION OF THE HOMEOWNERS' ASSOCIATION
SHALL BE PROVIDED TO THE ENVIRONMENTAL ENGINEERING
DEPARTMENT FOR APPROVAL. THE ENVIRONMENTAL ENGINEERING
DEPARTMENT WILL DETERMINE WHETHER THE SUBDIVISION HAS
BEEN PROVIDED WITH THE INFORMATION TO DEVELOP AND
IMPLEMENT A FERTILIZATION/LAWN CARE PROGRAM TO MINIMIZE
PHOSPHOROUS RUNOFF. THE REQUIREMENTS OF THE PROGRAM
SHALL BECOME A PART OF THE COVENANTS FOR THE PROJECT
AFFECTING ALL PROPERTIES WITHIN THE DEVELOPMENT.
.
8. SPECIAL UPPER SWIFT CREEK WATERSHED END TREATMENT
AS DIRECTED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT
WILL BE PLACED IN THE VICINITY OF THE TERMINUS OF MANMADE
STORM DRAINAGE OUTFALLS.
.
9. THE ENVIRONMENTAL ENGINEERING DEPARTMENT MAY
IMPOSE A MORE RIGOROUS EROSION AND SEDIMENT CONTROL
PROGRAM THAN THAT WHICH IS PROVIDED BY MINIMUM
STANDARDS FOUND IN THE VIRGINIA EROSION AND SEDIMENT
CONTROL HANDBOOK.
.
10. AS DIRECTED BY ENVIRONMENTAL ENGINEERING, A DAM FAILURE
ANALYSIS SHALL BE PERFORMED BASED ON AN OVER-TOPPING BREACH
OF THE DAM EMBANKMENT DURING A 100 YEAR STORM EVENT.
EXISTING OR PROPOSED HOMES SHALL BE OUTSIDE THE DAM FAILURE
LIMITS. VIRGINIA DAM SAFETY ACT CRITERIA MAY TAKE
PRECEDENCE.
.
11. GRADING ON INDIVIDUAL LOTS WILL BE PROVIDED SO THAT
EACH PROPERTY WILL HAVE A SURFACE DRAINAGE CONFIGURATION
FUNCTIONING INDEPENDENTLY FROM ITS ADJACENT LOTS.
.
12. ROOF GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED ON THE
DWELLINGS. ALL ROOF DRAINAGE LEADERS WILL BE TIED DIRECTLY
INTO MINIMUM 12" ONSITE STORM SEWERS OR OTHER STABLE
CONVEYANCE SYSTEMS DEEMED APPROPRIATE BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
13. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE ENVIRONMENTAL
ENGINEERING DEPARTMENT MUST HAVE RECEIVED
DOCUMENTATION THAT THE SUB-DIVIDER OR HIS REPRESENTATIVE
HAS NOTIFIED CERTAIN PROPERTY OWNERS DETERMINED BY THE
DEPARTMENT OF THE PROPOSED ADJACENT CONSTRUCTION.
.
.
14. THE ALLEYS SHALL FUNCTION AS STORM WATER CONVEYANCE
SYSTEMS. THE ALLEY TYPICAL SECTION CAN BE AN INVERTED CROWN
WITH A 1-INCH PER FOOT CROSS SLOPE SUCH THAT THERE WILL BE A
MINIMUM 6-INCHES OF ELEVATION DIFFERENCE BETWEEN THE EDGE OF
PAVEMENT AND CENTERLINE IF THE ALLEY WIDTH WERE TO BE
12-FEET OR CURB AND GUTTER MAY BE USED.
.
15. THE 100-YEAR STORM SHALL NOT EXCEED THE CONTAINMENT
DEPTH OF THE ALLEYS. ALLEY PAVEMENT DESIGN SHALL BE
EQUIVALENT TO THAT REQUIRED FOR CHESTERFIELD COUNTY PUBLIC
ROADS.
.
16. STORM WATER IN THE ALLEYS SHALL BE PICKED UP BY DI-1
GRATED INLETS INTO WHICH THE INVERTED CROWNS WOULD FLOW
AND BE DISCHARGED VIA STORM SEWER OR OTHER METHOD
APPROVED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT.
.
17. ALLEY PAVEMENT SHALL BE SIGNED "PRIVATE MAINTENANCE"
AND LANGUAGE APPROVED AT TIME OF CONSTRUCTION PLAN APPROVAL.
.
18. UNLESS OTHERWISE APPROVED, THE RELEASE RATE FROM THE
SWM/BMP FACILITIES DURING THE 10 YEAR POST DEVELOPED STORM
EVENT SHALL NOT EXCEED THE PREDEVELOPED 2 YEAR STORM EVENT.
.
19. PRIOR TO APPROVAL OF ANY CONSTRUCTION PLAN WITHIN
CENTERPOINTE TOWNHOMES OR THE ADJACENT PARCEL 1B FUTURE
COMMERCIAL, THE 50' SWM/BMP EASEMENT AS DEPICTED IN THE
PRELIMINARY PLAT ON PARCEL 1B MUST BE RECORDED WITH DB-PG
PROVIDED TO THIS OFFICE.
.
. L.
.
NOTES:
.
PLEASE NOTE ADDITIONAL ON-SITE DETENTION MAY BE REQUIRED
DURING DETAILED REVIEW OF THE CONSTRUCTION PLAN TO SATISFY
THE PART IIB OR PART IIC FLOODING CRITERIA OF THE VIRGINIA
STORMWATER MANAGEMENT PROGRAM REGULATIONS. THIS MAY RESULT
IN A MAJOR REVISION TO THE PRELIMINARY PLAT AND/OR THE LOSS
OF LOTS TO ACCOMMODATE LARGER AND/OR ADDITIONAL STORMWATER
MANAGEMENT FACILITIES.
F