Subdivision Review Comments
All Subdivision Review Comments for Case # 17TS0136




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 17TS0136 STATUS: PENDING APPROVAL
PROJECT NAME: HARPERS MILL TOWNHOM - LAST INTERNET UPDATE: 11/20/17
SUBMITTAL TYPE: TENTATIVE SUBDIVISION
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 09/15/16 10/12/16 ******** ********
ENVIR.ENGR.-: 00 09/15/16 10/12/16 COMPLETE 10/12/16 RPW 748-1028
FIRE DEPT.--: 00 09/15/16 10/12/16 COMPLETE 09/29/16 JKL 748-1489
HOUSE NUMBER: 00 09/15/16 10/12/16 ******** ********
MAPPING/GIS-: 00 09/15/16 10/12/16 ******** ********
PLANNING----: 00 09/15/16 10/12/16 AMENDED* 11/10/16 BSM 717-6143
PARKS & REC.: 00 09/15/16 10/12/16 ******** ********
SCHOOL BOARD: 00 09/15/16 10/12/16 ******** ********
SOILS-------: 00 09/15/16 10/12/16 ******** ********
TRANSPORT.--: 00 09/15/16 10/12/16 COMPLETE 10/12/16 SES 751-4912
UTIL.PLAN.--: 00 09/15/16 10/12/16 ******** ********
UTILITIES---: 00 09/15/16 10/12/16 ******** ********
UTIL.R.O.W.-: 00 09/15/16 10/12/16 ******** ********
VDOT--------: 00 09/15/16 10/12/16 ******** ********
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: HARPER'S MILL TOWNHOMES
CASE NUMBER: 17TS0136
LATEST PLAN DATE: 08/30/2016
DEPT. REC'D. DATE: 09/19/2016
SUBMITTAL NUMBER: ONE
REVIEW DATE: 10/12/2016
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
1. THE ROAD IMPROVEMENT PHASING PLAN ON PAGE 3 IS NOT THE
CURRENT PHASING PLAN FOR HARPER'S MILL (THE REVISED PHASING
PLAN IS DATED 4/16/2015).
2. IN ACCORDANCE WITH PROFERRED CONDITION 3.C OF ZONING
CASE 14SN0534, LEFT AND RIGHT TURN LANES WILL BE REQUIRED
ON OTTERDALE ROAD EXTENDED AT ABELSON WAY. PLEASE ADD A
NOTE TO THAT EFFECT.
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: BRAD MORRISON / 717-6143
PLAN NAME: HARPERS MILL TOWNHOMES PRELIMINARY PLAT
PLAN NUMBER : 17TS0136
ORIGINAL PLAN DATE: 8/30/16
REVISION DATE:
LATEST SUBMISSION DATE: 8/30/16
REVIEW DATE: 10/10/16 AMENDED 11/10/16
SUBMITTAL NUMBER : 1
STATUS: REVISIONS REQUIRED
1. THE TOTAL NUMBER OF LOTS IS 148. LOTS SKIP FROM
NUMBER 97 TO 101.
2. THE APPROVED BMP MASTER PLAN DISPLAYS A BMP IN
THE APPROXIMATE LOCATION OF 24-35 THAT IS NOT
REFLECTED ON THE PROPOSED PRELIMINARY PLAT.
PLEASE COORDINATE WITH ENVIRONMENTAL ENGINEERING
REGARDING REVISION REQUIREMENTS.
3. SPECIFY VIRGINIA STATE SYSTEM COORDINATE POINTS
PER (NAD)83.
4. PULLMAN LANE RIGHT-OF-WAY MUST INCLUDE ALL
PORTIONS OF PULLMAN LANE.
5. A 5 FOOT WIDE COMMON AREA IS REQUIRED AROUND
EACH GROUP OF ATTACHED HOMES. THIS INCLUDES
SIDEYARDS IN BETWEEN GROUPS OF ATTACHED HOMES.
THE TOTAL COMMON AREA BETWEEN UNITS WOULD BE
10 FEET AT THE SIDEYARDS. ATTACHED UNITS ARE
LIMITED TO GROUPS OF 6.
6. THE ACREAGE OF THE RECREATIONAL AREA IS TO BE
RECORDED IN THE SUBDIVISION COVENANTS. PLEASE
SUMMARIZE THE TOTAL AMOUNT PROVIDED AND REQUIRED.
IF MULTIPLE DEVELOPMENTS ARE TO UTILIZE THE OFF
SITE FACILITY, INCLUDE THIS TABULATION AS WELL.
7. A CONCEPTUAL LANDSCAPE PLAN SHALL BE SUBMITTED
FOR REVIEW AND APPROVAL WITH TENTATIVE
SUBDIVISION REVIEW AND APPROVAL. SEE III.A.3.G.
STREET TREES ARE REQUIRED.
8. STREET LIGHTING SHALL BE APPROVED AT THE TIME
OF TENTATIVE SUBDIVISION APPROVAL. SEE III.A.3.I
9. SHOW LOCATION OF THE PROPOSED CBA BOX TO BE
APPROVED BY USPS.
10. ZONING CASE 14SN0534 SHOULD BE REFERENCED
IN THE GENERAL NOTES.
11. 1 COMMON AREA PARKING SPACE IS REQUIRED
PER 5 UNITS. 148 LOTS WILL REQUIRE 30 SPACES.
12. AREAS LABELED OPEN SPACE SHOULD BE
REFERRED TO AS COMMON AREA, AS THAT IS THE
REQUIREMENT TO BE MET.
NOTES:
1. STREET TREE PLANTING MUST BE COORDINATED WITH
UTILITIES, DRIVEWAYS ETC. WITH SUBMITTED
LANDSCAPE PLAN.
2. UTILITY RIGHT OF WAYS MAY NOT RUN PARALLELN
THROUGH REQUIRED BUFFERS. PLAYED ON THE PLAT.
3. BUFFERS ON ADJACENT PARCELS SHOULD BE SHOWN
AS APPROVED IF THEY ARE DISPLAYED ON THE PLAT.
4. COMMON AREA PARKING MUST BE PROVIDED
OFF-STREET PER 19.1-235.
5. A MINIMUM OF A 5 FOOT SETBACK WILL BE
REQUIRED FROM COMMON AREA PARKING. THESE
AREAS MUST BE LANDSCAPED CONSISTENT WITH
REQUIREMENTS OF CASE # 02SN0209.
6. COMMON AREA PARKING MAY NOT BE APPLIED
TOWARDS MEETING COMMON AREA REQUIREMENTS.
7. CBA SHOULD BE LOCATED CONVENIENT TO COMMON
PARKING.
THE BUILDINGS. THE MEASUREMENT WILL BE FROM THE EDGE
OF PAVEMENT TO THE BUILDING.ESTER / (804) 748-1489
PLAN NAME : HARPERS MILL TOWNHOMES
PLAN NUMBER: 17TS0136
LATEST PLAN DATE : 8/30/16
REVIEW DATE : 9/29/16
DEPARTMENT RECEIVED DATE: 9/21/16
SUBMITTAL NUMBER : 1ST REVIEW
STATUS : APPROVED
TABLE REVIEW: YES
NOTE: IFC APPENDIX, D105, STATES WHERE THE VERTICAL
DISTANCE BETWEEN THE GRADE PLANE AND THE HIGHEST ROOF
SURFACE EXCEEDS 30 FEET, APPROVED AERIAL FIRE APPARATUS
ACCESS ROADS SHALL BE PROVIDED. THE AERIAL FIRE APPARATUS
ACCESS ROAD SHALL BE A MINIMUM OF TWENTY-SIX FEET
UNOBSTRUCTED CLEAR WIDTH IN THE IMMEDIATE VICINITY OF
THE BUILDING. OVERHEAD OBSTRUCTIONS IN FORM OF UTILITY
OR POWER LINES SHALL NOT BE LOCATED WITHIN THE AERIAL FIRE
APPARATUS ACCESS ROADWAY. AT LEAST ONE AERIAL FIRE
APPARATUS ACCESS ROADWAY SHALL BE LOCATED A MINIMUM
OF FIFTEEN FEET AND A MAXIMUM OF THIRTY FEET FROM THE
BUILDING AND POSITIONED PARALLEL TO ONE ENTIRE SIDE OF THE
BUILDING. PLEASE SHOW THE DIMENSION ON THE PLAN FOR ALL OF
THE BUILDINGS. THE MEASUREMENT WILL BE FROM THE EDGE
OF PAVEMENT TO THE BUILDING.
NOTE: COMPLIANCE WITH 17-76 OF THE SUBDIVISION ORDINANCE
IN THE CHESTERFIELD COUNTY CODE SHALL BE MAINTAINED
AT ALL TIMES.
NOTE: HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S) REQUIRED
AND THEIR LOCATION WILL BE EVALUATED AT THE TIME OF
CONSTRUCTION PLAN REVIEW.
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
PLAN NAME: HARPER'S MILL TOWNHOMES
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: REBECCAH P. WARD / 748-1977
PLAN NUMBER: 17TS0136
ORIGINAL PLAN DATE: 08/30/16
REVIEW DATE: 10/12/16
SUBMITTAL NUMBER: 1
STATUS: REVISION REQUESTED
TABLE REVIEW: NO
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS THE
FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS PERTAINING
TO THE ABOVE REFERENCED PRELIMINARY PLAN DATED 08/30/16,
RECEIVED BY THE PLANNING DEPARTMENT ON 08/30/16 AND BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT ON 09/20/16.
PLEASE SPECIFY THE TENTATIVE CASE NUMBER 17TS0136 ON SHEET
1.
PLEASE LABEL ALL EXISTING EASEMENTS WITH THE DEED BOOK AND
PAGE NUMBER.
PLEASE PROVIDE THE NAME OF THE PERSON WHO PERFORMED THE
WETLANDS DELINEATION TO VERIFY THE PERSON IS ON THE
CHESTERFIELD COUNTY QUALIFIED WETLANDS EXPERT LIST. IN
ADDITION, PLEASE PROVIDE THE DATE AND STATUS OF THE WETLAND
DELINEATION.
PLEASE LABEL THE MINIMUM 35-FOOT BUILDING SETBACK DISTANCE
IN RELATION TO ALL WETLANDS.
PLEASE PROVIDE A COMPLETE STREET NAME CLEARINGHOUSE REQUEST
WHICH HAS BEEN REVIEWED AND APPROVED BY THE RICHMOND
REGIONAL PLANNING DISTRICT COMMISSION.
PLEASE SHOW THE PROPOSED SWM/BMP EASEMENT AND 50-FOOT
VEGETATIVE PERIMETER YARD, AS WELL AS THE PRELIMINARY
LOCATION OF THE BMP MAINTENANCE ACCESS DRIVE.
PLEASE SHOW THE LIMITS OF THE CONSERVATION AREAS REQUIRED BY
THE US CORPS OF ENGINEERS WETLANDS PERMIT.
PRIOR TO APPROVAL OF THE HARPER'S MILL TOWNHOMES TENTATIVE,
THE DEVELOPER WILL SUBMIT A LETTER OF ACKNOWLEDGEMENT OF THE
CONDITION REGARDING MASONRY EMBELLISHMENTS WITHIN THE VDOT
CLEAR ZONE. THIS ACKNOWLEDGEMENT IS THE RESPONSIBILITY OF
THE DEVELOPER AND NOT HIS REPRESENTATIVE AS HE IS ULTIMATELY
RESPONSIBLE FOR REMOVAL OF HEADWALLS IN ALL NEW SUBDIVISIONS
SHOULD IT BECOME NECESSARY. A DRAFT OF THAT LETTER IS
ENCLOSED.
CBPA/USCW:
1. THE LOCATION AND LAYOUT OF BMP #1 IS NOT CONSISTENT WITH
THE APPROVED OVERALL MASTER BMP PLAN. PLEASE PROVIDE
INFORMATION ON SHEET 3 VERIFYING THE REVISED BASIN WILL
PROVIDE THE MINIMUM WATER QUALITY VOLUME REQUIRED FOR THE
89.71 ACRE DRAINAGE AREA. THE ORIGINAL APPROVED PRELIMINARY
VOLUME INFORMATION IS PROVIDED FOR YOUR REFERENCE.
2. THE LOCATION AND LAYOUT OF BMP #1 IS NOT CONSISTENT WITH
THE APPROVED OVERALL MASTER BMP PLAN OR THE APPROVED
PRELIMINARY PLAT FOR HARPER'S MILL SOUTHWEST PHASE. PRIOR
TO APPROVAL OF THE PRELIMINARY PLAT FOR THE HARPER'S MILL
TOWNHOMES, THE OVERALL MASTER BMP PLAN AND THE PRELIMINARY
PLAT FOR HARPER'S MILL SOUTHWEST PHASE MUST BE REVISED AND
APPROVED, TO REFLECT THE NEW BASIN LOCATION AND PRELIMINARY
DESIGN.
NOTES:
PLEASE PROVIDE A WRITTEN RESPONSE IN THE MARGIN OF A COPY OF
THESE COMMENTS WITH YOUR TENTATIVE PLAT REVISIONS.
TENTATIVE CONDITIONS COULD INCLUDE, BUT NOT BE LIMITED TO
THE FOLLOWING:
1. THE LAND DISTURBANCE PERMIT FOR BMP #1 MUST BE ISSUED
PRIOR TO OR CONCURRENT WITH THE LAND DISTURBANCE PERMIT FOR
THE FIRST SECTION OF THE HARPER'S MILL TOWNHOMES.
2. THE DEED BOOK AND PAGE NUMBER FOR THE SWM/BMP EASEMENT
MUST BE PROVIDED PRIOR TO OR CONCURRENT WITH THE RECORDATION
OF THE FIRST SECTION OF THE HARPER'S MILL TOWNHOMES.
3. THE BMP'S INITIAL, PREDOMINANT WATER-QUALITY FUNCTION
SHALL BE SEDIMENT CONTROL; THE IMPLEMENTATION OF WHICH SHALL
BE COORDINATED WITH THE FIRST PORTION OF THE PROJECT THAT
DRAINS IN ITS DIRECTION.
4. THE PEDESTRIAN-ACCESS FACILITIES DESIGN AS SHOWN ON THE
TENTATIVE SHALL BE INCLUDED IN THE ROAD AND DRAINAGE PLANS
THAT MUST BE APPROVED BY BOTH VDOT AND THE ENVIRONMENTAL
ENGINEERING DEPARTMENT. ROAD RIGHT-OF-WAY SHALL BE WIDE
ENOUGH TO ENCOMPASS THE PEDESTRIAN-ACCESS FACILITIES IF THE
SIDEWALKS MEET STATE CRITERIA.
5. THE 100-YEAR FLOODPLAIN SURROUNDING THE WETLANDS WILL BE
SHOWN AS FIELD LOCATED ON THE CONSTRUCTION PLANS AND SHALL
BE RE-FIELD VERIFIED PRIOR TO THE ISSUANCE OF A BUILDING
PERMIT. AN NBP SHALL BE STIPULATED FOR THE AFFECTED LOTS.
6. THE FLOODPLAIN AS SHOWN ON THE APPROVED CONSTRUCTION
PLANS AND THE RECORDED SUBDIVISION PLAT SHALL BE THE RESULT
OF HYDROLOGIC AND HYDRAULIC ENGINEERING METHODS AND
ASSUMPTIONS WHICH ARE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT.
7. A DAM-FAILURE ANALYSIS SHALL, AT A MINIMUM, BE PERFORMED
BASED ON AN OVER-TOPPING BREACH OF THE DAM EMBANKMENT DURING
A 100 YEAR STORM EVENT. CRITERIA PER THE VIRGINIA DAM
SAFETY ACT WILL TAKE PRECEDENCE. EXISTING OR PROPOSED HOMES
SHALL BE OUTSIDE OF THE DAM FAILURE INUNDATION LIMITS.
8. THE DESIGN AND CONSTRUCTION OF THE SWM/BMPS THAT WILL BE
COUNTY MAINTAINED FACILITIES SHALL BE SUBJECT TO DOCUMENTED
GEOTECHNICAL APPROVAL. THE SERVICES THAT MUST BE PROVIDED
BY THE GEOTECHNICAL ENGINEER SHALL INCLUDE FULL-TIME
GEOTECHNICAL INSPECTION PAID FOR BY THE DEVELOPER. THAT
FULL-TIME INSPECTION SHALL INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
A. PARTICIPATION/INPUT INTO THE DESIGN PROCESS AS NECESSARY
TO FACILITATE THE APPROVAL PROCESS OF THE INDEPENDENT
GEOTECHNICAL CONSULTANT. OBSERVATION, TESTING AND
DOCUMENTATION OF:
I. SUITABLE SUB-GRADES TO RECEIVE COMPACTED STRUCTURAL FILL
FOR EARTH DAM CONSTRUCTION.
II. THE CUT-OFF TRENCH, SPILLWAY PIPE, DRAINAGE BLANKET,
RISER STRUCTURE, AND CONCRETE CHUTE SPILLWAY SUB-GRADES AS
APPLICABLE TO EVALUATE WHETHER SUITABLE SOIL IS PRESENT AT
BEARING GRADE TO VERIFY PROPER INSTALLATION.
III. REINFORCING STEEL, IF REQUIRED, TO EVALUATE ITS
CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS.
9. THE FACILITY CERTIFICATION PROCESS SHALL BE PERFORMED BY
AN ENGINEERING/SURVEYING PROFESSIONAL APPROVED BY THE COUNTY
AT THE OWNER'S EXPENSE.
10. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
11. AS DIRECTED BY ENVIRONMENTAL ENGINEERING, ENGINEERED
FILLING, GRADING, AND DRAINAGE IMPROVEMENTS SHALL BE
INCLUDED IN THE CONSTRUCTION PLANS FOR THOSE LOTS IMPACTED
BY THE CONCENTRATION OF STORMWATER RUNOFF. THE AFFECTED LOTS
SHALL BE ANNOTATED WITH AN NBP.
12. PRIOR TO CONSTRUCTION PLAN APPROVAL, DOCUMENTATION MUST
BE PROVIDED TO ENVIRONMENTAL ENGINEERING THAT CERTAIN
PROPERTY OWNERS HAVE BEEN NOTIFIED OF THE PROPOSED
CONSTRUCTION ACTIVITY.
13. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE WETLANDS MAP
WHICH ACCOMPANIES THE USCOE WETLANDS CONFIRMATION
DOCUMENTATION SHALL BE PROVIDED TO THE ENVIRONMENTAL
ENGINEERING DEPARTMENT.
14. SPECIAL UPPER SWIFT CREEK WATERSHED END TREATMENT AS
DIRECTED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT WILL BE
PLACED IN THE VICINITY OF THE TERMINUS OF MANMADE STORM
DRAINAGE OUTFALLS. THE DI-7 END TREATMENTS SHALL BE EXCLUDED
FROM WITHIN THE LIMITS OF LOTS.
15. UNLESS OTHERWISE APPROVED, THE SPILLWAY STRUCTURE FOR
THE WET POND(S) SHALL BE A CONCRETE WEIR.
16. BASED ON THE FINDINGS OF A QUALIFIED GEOTECHNICAL
PROFESSIONAL, THE CONSTRUCTION PLANS SHALL SHOW THE LOCATION
OF ALL AREAS OF FORMER MINING ACTIVITY. IF THE LAND AREA
COVERED BY THE CONSTRUCTION PLANS CONTAINS NO FORMER MINING
ACTIVITY, A STATEMENT TO THAT EFFECT WILL BE INCLUDED ON THE
CONSTRUCTION PLANS. IF THE LAND AREA COVERED BY THE
CONSTRUCTION PLANS DOES HAVE MINING ACTIVITY, A STATEMENT
WILL BE INCLUDED WHICH INDICATES THAT THE FORMER MINING
ACTIVITY AS SHOWN ON THE CONSTRUCTION PLANS IS THE FULL
EXTENT OF MINING ACTIVITY WITHIN THE AREA COVERED BY THE
CONSTRUCTION PLANS. THE QUALIFIED PROFESSIONAL WILL ALSO
INDICATE THOSE LOTS WHERE GEOTECHNICAL BORINGS MUST BE
PERFORMED IN ORDER TO INSURE NO HOUSE IS BUILT OVER AREAS
AFFECTED BY FORMER MINING ACTIVITY. IF APPLICABLE,
RECOMMENDED SETBACK DISTANCES FROM AREAS OF FORMER MINING
ACTIVITY SHALL BE SPECIFIED.
17. PRIOR TO RECORDATION THE ENVIRONMENTAL ENGINEERING
DEPARTMENT MUST HAVE RECEIVED DOCUMENTATION FROM THE
GEOTECHNICAL EXPERT THAT ALL AREAS OF FORMER MINING ACTIVITY
AS SHOWN ON THE APPROVED CONSTRUCTION PLAN HAVE BEEN
RECLAIMED IN A MANNER CONSISTENT WITH EITHER DEPARTMENT OF
MINES, MINERALS AND ENERGY RECLAMATION CRITERIA OR CRITERIA
RECOMMENDED BY THE GEOTECHNICAL ENGINEER AS BEING
APPROPRIATE AND IN COMPLIANCE WITH GENERALLY ACCEPTED
GEOTECHNICAL ENGINEERING PRACTICE FOR SUCH SITUATIONS AS MAY
BE ENCOUNTERED. ALL AREAS OF FORMER MINING ACTIVITY SHALL
BE PORTRAYED ON THE RECORD PLAT.
18. ENVIRONMENTAL ENGINEERING MAY IMPOSE MORE RIGOROUS
EROSION AND SEDIMENT CONTROL MEASURES THAN THAT WHICH IS
PROVIDED BY THE MINIMUM STANDARDS FOUND IN THE VIRGINIA
EROSION AND SEDIMENT CONTROL HANDBOOK.
19. ROOF GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED ON THE
DWELLINGS. ALL ROOF DRAINAGE LEADERS WILL BE TIED DIRECTLY
INTO MINIMUM 12" ONSITE STORM SEWERS OR OTHER STABLE
CONVEYANCE SYSTEMS DEEMED APPROPRIATE BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT.
(PLEASE PLACE ON DEVELOPER LETTERHEAD)
(DATE)
KIRKLAND A. TURNER, DIRECTOR
CHESTERFIELD COUNTY PLANNING DEPARTMENT
P. O. BOX 40
CHESTERFIELD, VIRGINIA 23832
RE: ENTRANCE EMBELLISHMENTS (____________ TENTATIVE)
DEAR MR. TURNER:
AS DEVELOPER OF THE PROPOSED __________________ SUBDIVISION,
I AM AWARE THAT THE FOLLOWING NOTE IS NOW REQUIRED NOT ONLY
ON TENTATIVES BUT ALSO ON RECORD PLATS.
"NO STRUCTURE EMBELLISHMENTS WILL BE ALLOWED ON VDOT
RIGHT-OF-WAY WITHOUT THE COMMITMENT OF, OR THE ISSUANCE OF,
A VDOT LAND USE PERMIT. WITHIN THE 10' CLEAR ZONE (MEASURED
FROM THE EDGE OF THE ROADWAY'S PAVEMENT OUT
10'), NO STRUCTURE EMBELLISHMENT WILL BE PERMITTED THAT IS
CLOSER THAN 3' FROM THE EDGE OF PAVEMENT OF THE PUBLIC
STREET OR HIGHER THAN 6" ABOVE THE SURFACE OF THE DRIVE."
I WILL DO ALL POSSIBLE TO PROVIDE THE CORRECT INFORMATION
FOR BUILDERS OR CITIZENS CONSTRUCTING ENTRANCE
EMBELLISHMENTS.
I AM ALSO AWARE THAT, PRIOR TO STATE ACCEPTANCE OF THE
ROADS, I AM RESPONSIBLE FOR REMOVING EMBELLISHMENTS THAT DO
NOT MEET STATE STANDARDS.
SINCERELY,
DEVELOPER NAME (PRINTED)
DEVELOPER SIGNATURE
(DATE)
****************************************

Go to Case Selection Form or Go to Project List