All Subdivision Review Comments for Case # 17CP0070




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 17CP0070 STATUS: PENDING APPROVAL
PROJECT NAME: HARPERS MILL SOUTH P - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: CONSTRUCTION PLAN
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ENVIR.ENGR.-: 02 06/19/17 07/10/17 ******** 01/04/17 ASM 717-6711
FIRE DEPT.--: 02 06/19/17 07/10/17 AMENDED* 07/07/17 JKL 748-1489
PLANNING----: 02 06/19/17 07/10/17 ******** 01/04/17 GWK 706-7691
TRANSPORT.--: 02 06/19/17 07/10/17 COMPLETE 06/28/17 SES 751-4912
UTIL.PLAN.--: 02 06/19/17 07/10/17 AMENDED* 07/18/17 TVM 751-4435
UTILITIES---: 02 06/19/17 07/10/17 ******** ********
UTIL.R.O.W.-: 02 06/19/17 07/10/17 ******** ********
VDOT--------: 02 06/19/17 07/10/17 ******** ********
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE #: W.B. PAYNE III/751-4336
NAME OF PLAN: HARPERS MILL SOUTH PHASE SECTION 4
ADDRESS: OTTERDALE ROAD AND VERNEHAM DRIVE
SUBMISSION DATE: 12/01/16
PLAN DATED: 10/18/16
REVIEW DATE: 12/20/17
SITE PLAN NUMBER: 17CP0070
COMMENTS: 1ST REVIEW - NOT APPROVED
TABLE REVIEW:
PLAT PROCESS:
1. ADD THE UTILITIES PROJECT NUMBER DESIGNATED FOR THIS
PROJECT (16-0323) TO ALL PLAN SHEETS.
2. ADD THE FOLLOWING UTILITIES CONTACT INFORMATION TO THE
PLAN AS APPLICABLE: W.B. PAYNE III, PRINCIPAL ENGINEER,
804-751-4336, PAYNEW@CHESTERFIELD.GOV.
3. PROVIDE SIMULTANEOUS FLOW TEST INFORMATION RESULTS ON
WATER FLOW INFORMATION PER DES-5 ON A WATER MODEL
AND FLOW CALCULATION SHEET, LIKE THAT PREVIOUSLY PROVIDED
FOR THE ADJACENT SOUTH PHASE SECTIONS. LABEL ALL PIPES/
NODES ON MAP. PLEASE BE ADVISED THAT START POINT FLOW
TEST RESULTS PROVIDED BY UTILITIES EXPIRE AFTER 6 MONTHS.
WILL 8" DIAMETER WATERLINE FROM BLOOMING ROAD TO THE FH
AT LOT 26 BE NECESSARY?
4. FH'S MUST BE LOCATED 3' BEHIND SIDEWALKS. THE PLAN
CURRENTLY SHOWS THE PROPOSED FH'S LOCATED BEHIND THE
SIDEWALK HOWEVER THERE APPEARS TO BE ONLY 2.5' BETWEEN
THE BACK OF THE SIDEWALK AND THE RIGHT-OF-WAY/PROPERTY LINE
AND THEREFORE, THE FH'S WOULD BE LOCATED ON PRIVATE
PROPERTY. PLEASE PROVIDE A 10' WIDE SEGMENT OF WATER
EASEMENT AROUND EACH FH WITH AT LEAST 5' CLEARANCE BEHIND
EACH HYDRANT.
5. RE: COMMENT #4, REVISE THE FH DETAIL SHOWN ON SHEET
C7.1 TO REFLECT THE PLACEMENT OF HYDRANTS 3' BEHIND THE
SIDEWALK
6. INSTALL THE SEWER LATERAL FOR LOT 7 AT > A 90 DEGREE
ANGLE.
7. INSTALL THE SEWER LATERAL FOR LOT 34 AT A > 90 DEGREE
ANGLE INTO MH-31.
8. THE MAXIMUM ALLOWABLE NUMBER OF LATERALS IN A 48"
MH ARE THREE AND MH-33 HAS FIVE SEWER LATERAL
CONNECTIONS WITH THREE OF THE LATERAL ENTRY ANGLES < 90
DEGREES. EITHER INSTALL A 60" DIAMETER MH OR REDUCE THE
NUMBER OF LATERALS CONNECTED TO THE MH TO THREE. FOR
EXAMPLE, CAN THE LATERAL FOR LOT 18 BE INSTALLED INTO THE
MAIN (FROM THE FRONT OR REAR OF THE BUILDING ENVELOPE) AND
NOT CONFLICT WITH THE STORM PIPE? ADDITIONALLY, CONFIGURE
ALL LATERALS WITH ENTRY ANGLES > 90 DEGREES. CAN THE
DRIVEWAY LOCATION FOR LOT 21 BE REVISED TO ALLOW AN ENTRY
ANGLE > 90 DEGREES?
9. ARE OR WILL THERE BE EXISTING 2" BO'S LOCATED AT THE
WATERLINE TIE-IN POINTS? IF SO, ADD A NOTE TO BOTH PLAN AND
PROFILE INDICATING THE CONTRACTOR IS TO REMOVE THE BO PRIOR
TO MAKING THE TIE-IN'S. ADDITIONALLY, ADD A NOTE STATING ALL
SALVAGEABLE PUBLIC APPURTENANCES ARE TO BE RETURNED TO
CHESTERFIELD UTILITIES AT THE DISCRETION OF THE CONSTRUCTION
INSPECTOR.
10. FOR THE PURPOSE OF MAKING THE BLOOMING ROAD
WATERLINE TIE-IN WEST OF GRAHAM'S FERRY LANE, SHOW/
DENOTE THE "EXISTING" GV TO BE USED FOR SHUT-OFF.
11. THE WM'S FOR LOTS 11 & 12 SHOULD BE GRAPHICALLY
SHOWN THE SAME AS THOSE ON ALL OTHER LOTS; DIRECTLY BEHIND
THE RIGHT-OF-WAY LINE.
12. FOR FUTURE MAINTENANCE REASONS, UTILITIES RECOMMENDS
THREE GV'S AT THE MAINLINE TEES FOR GRAHAM'S FERRY LANE
AND SHARPE COURT.
13. WHAT IS THE EXTENT OF THE SECTION 4 SUBDIVISION ON
GRAHAM'S FERRY LANE? IF THE SUBDIVISION STOPS AT THE END
OF CONSTRUCTION, THEN A SEGMENT OF WATER EASEMENT WILL
NEED TO BE DEDICATED TO ENCOMPASS THE WATERLINE AND BO
LOCATED OUTSIDE THE PAVEMENT. IF NOT, ADD A LINE AND
NOTATION AT THE POINT OF DEMARCATION TO SHEET C3.0.
15. ADD A NOTE TO THE PROFILE INDICATING ALL FITTINGS ARE TO
MECHANICALLY RESTRAINED. ADDITIONALLY, PROVIDE RESTRAINT
CALCULATIONS WITH THE NEXT SUBMITTAL. PLEASE USE 150 PSI
AND A 1.5 SF.
16 THE LENGTHS OF MECHANICAL RESTRAINT MUST BE CALCULATED
FOR THE DEAD ENDS AT GRAHAM'S FERRY LANE AND SHARPE
COURT AND SHOWN ON THE PROFILE; PLEASE REVISE.
17. THE VERTICAL TRANSITION SHOWN AT STA 6+33 (SHARPE
COURT) MUST BE FULLY RESTRAINED CLASS 52 DI PIPE PER DETAIL
WAT-8; PLEASE REVISE THE PROFILE ACCORDING TO THIS DETAIL.
18. CAN THE VERTICAL TRANSITION AT STA 3+80 (SHARPE COURT)
BE ELIMINATED BY "DEEPENING" THE WATERLINE AND CROSSING
UNDER THE STORM DRAIN USING ONE "STICK" OF CLASS 52 DI
PIPE (TO BE CENTERED UNDER THE CROSSING) AT A MINIMUM 6"
CLEARANCE? ONCE PAST THE CONFLICT, THE PIPE MAY THEN BE
TRANSITIONED "UP" USING FITTINGS, ALLOWABLE BENDING, OR A
COMBINATION OF BOTH.
18. CAN THE VERTICAL TRANSITION AT STA 3+80 (SHARPE COURT)
BE ELIMINATED BY "DEEPENING" THE WATERLINE AND CROSSING
UNDER THE STORM DRAIN USING ONE "STICK" OF CLASS 52 DI
PIPE (TO BE CENTERED UNDER THE CROSSING) AT A MINIMUM 6"
CLEARANCE? ONCE PAST THE CONFLICT, THE PIPE MAY THEN BE
TRANSITIONED "UP" USING FITTINGS, ALLOWABLE BENDING, OR A
COMBINATION OF BOTH.
19. THE WATERLINE ALONG SHARPE COURT IS SHOWN AS 6" PVC
HOWEVER, THE LABEL ON THE PROFILE INDICATES 8" PVC; REVISE
THE LABEL ACCORDINGLY.
20 INSTALL THE SEWER LATERAL FOR LOT 3 DIRECTLY INTO THE
MH; IT IS CURRENTLY SHOWN CONNECTING TO THE LINE JUST
OUTSIDE THE MH.
21. RE: THE 5/8" WM TYPICAL ON SHEET C3.0, ADD ¾"
COPPER SERVICE AND ¾" CORP STOP.
22. PLEASE ADD THE SIZE OF THE PROPOSED SEWER LINES ON
BLOOMING ROAD AND SHARP COURT TO SHEET C3.0.
23. RE THE DROP SHOWN FOR MH EX-28, WAS THE INTERNAL
DROP PREVIOUSLY INSTALLED AS PART OF SECTION 2? IF SO,
PLEASE CLARIFY THE DROP IS EXISTING ON THE PROFILE.
ALSO, ADD "PER MAN-16" TO THE DESCRIPTIONS FOR BOTH MH
DROPS AS APPLICABLE.
24. ADD 1.0' OF STONE OVER TOP OF THE PIPE FOR ALL AREAS
WHERE THE DEPTH EXCEEDS 14' AROUND MH'S-35 AND 37.
25. ADD DEFLECTION ANGLES TO ALL MH'S ON SHEET C3.0.
26. WILL MH-32 BE LOCATED IN A MAINTAINED AREA? IF NOT,
PLEASE SHOW THE RIM TO BE INSTALLED 12" ABOVE GRADE.
27.WILL ANY OF THE DWELLINGS HAVE BASEMENTS WHERE
GRAVITY SEWER WILL NOT BE APPLICABLE? IF SO, A NOTE SHOULD
BE ADDED TO THE PLAN STATING A PRIVATE PUMP WOULD BE
REQUIRED TO SERVE THE BASEMENT.
28. ADD A NOTE TO THE PROFILES INDICATING FOR ALL LATERALS
TIED DIRECTLY INTO MH'S, THE CONTRACTOR SHALL MATCH THE PIPE
CROWN OF THE 6" LATERAL WITH THE PIPE CROWN OF THE 8" MAIN.
29. PLEASE RELOCATE THE WATER SERVICE LINES FOR LOTS 18 AND
19 OUTSIDE THE DRIVEWAY APRONS. UTILITIES PREFERS THAT WATER
SERVICES AND LATERALS ALWAYS BE LOCATED OUTSIDE OF
DRIVEWAYS WHEREVER POSSIBLE.
30. DOES THE DEVELOPER INTEND TO ADD AN IRRIGATION SYSTEM
IN THIS SECTION? IF SO, PLEASE MAKE PROVISIONS AS PART OF TH
PLAN.
31. SHOW THE LOCATION OF THE WATERLINE "JUMPER" ON SHEET
C3.0. PLEASE BE AWARE HE JUMPER CANNOT BE REMOVED UNTIL
ALL FLUSHING AND TESTING HAS SUCCESSFULLY BEEN COMPLETED.
32 MH EX-79 IS SHOWN AS EXISTING; HAS THIS MH BEEN
INSTALLED? IF SO, PLEASE PROVIDE THE UTILITY PROJECT NUMBER.
AND ADD THE APPLICABLE HARPER'S MILL SECTION TO THE PLAN. IF
NOT, PLEASE BE ADVISED THE PROPOSED SEWER LINE ACROSS
VERNHAM DRIVE MUST TERMINATE AT A MH; THEREFORE, MH
EX-79 MUST EITHER BE INSTALLED AS PART OF THIS PLAN OR THE H
ARPER'S MILL SECTION PLAN THAT INCLUDES MH EX-79 MUST HAVE B
EEN RELEASED TO CONSTRUCTION PRIOR TO SOUTH PHASE SECTION 4
BEING RELEASED TO CONSTRUCTION.
33. CLARIFY WHETHER VERNHAM IS SPELLED "VERNEHAM"
OR "VERNHAM". IT IS SHOWN BOTH WAYS IN THE PLAN/PROFILE.
34. PLEASE CLARIFY THERE ARE NO CONFLICTS WITH PROPOSED
STORM DRAIN PIPING AND LATERAL LOCATIONS AT THE PROPERTY
LINES. NOTE THAT THE MINIMUM LATERAL DEPTH AT THE PROPERTY
LINE IS 5' AND THE PREFERRED MAXIMUM IS 8'.
35. PLEASE BE ADVISED THAT PER A CONDITION OF ZONING, WHICH
REQUIRES THAT THE DEVELOPER CONTRIBUTE TOWARDS THE COST
OF EXPANDING THE DRY CREEK WASTEWATER PUMP STATION,
PAYMENT TO THE COUNTY IN THE AMOUNT OF $2,780.00 MUST
BE MADE PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT FOR
THIS SECTION. THIS MONETARY AMOUNT IS BASED UPON THE GROSS
ACREAGE OF THE SECTION AND IS SUBJECT TO CHANGE IF THIS
ACREAGE CHANGES THROUGHOUT THE REVIEW. PAYMENTS ARE TO BE
SUBMITTED TO THE ATTENTION OF RANDY PHELPS, PRINCIPAL
ENGINEER-DEVELOPMENT SECTION, CHESTERFIELD COUNTY
UTILITIES DEPARTMENT. CHECKS ARE TO BE MADE PAYABLE TO
"TREASURER, CHESTERFIELD COUNTY".
THE OWNER IS REQUIRED TO ENTER INTO A COUNTY UTILITIES
CONTRACT PRIOR TO THE START OF CONSTRUCTION. PRIOR TO THE
PREPARATION OF THE UTILITIES CONTRACT, UTILITIES MUST BE IN
RECEIPT OF THE "ACCEPTED" BID PROPOSAL BETWEEN THE
DEVELOPER AND THE COUNTY APPROVED UTILITIES CONTRACTOR AS
WELL AS THE PROJECT'S INFORMATIONAL SHEET FOUND ON THE
"DEVELOPER'S CHECKLIST". PLEASE SEND THOSE TWO ITEMS TO
THE ATTENTION OF BILL PAYNE (PAYNEW@CHESTERFIELD.GOV
OR BY CALLING 804-751-4336). THE BID PROPOSAL MUST
BE BASED ON THE APPROVED SITE PLAN. BE ADVISED THAT
IF THE SITE PLAN IS REVISED AND REAPPROVED SUBSEQUENT
TO THE PREPARATION OR RECORDATION OF THE UTILITIES
CONTRACT, THE BID PROPOSAL SHALL BE REVISED ACCORDINGLY
AND A REVISED UTILITIES CONTRACT MAY BE NECESSARY.
AFTER FINAL SITE PLAN APPROVAL, FOUR SETS TOTAL OF THE
APPROVED PLANS MUST BE SENT DIRECTLY TO THE UTILITIES
DEPARTMENT FOR OUR USE DURING CONSTRUCTION INSPECTION.
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE #: W.B. PAYNE III/751-4336
NAME OF PLAN: HARPERS MILL SOUTH PHASE SECTION 4
ADDRESS: OTTERDALE ROAD AND VERNEHAM DRIVE
SUBMISSION DATE: 4/3/17
PLAN DATED: 3/29/17
REVIEW DATE: 4/10/17
SITE PLAN NUMBER: 17CP0070
COMMENTS: 2ND REVIEW - NOT APPROVED
TABLE REVIEW: YES
PLAT PROCESS:
.
1.RE: COMMENT #8 FROM THE DECEMBER 20TH UTILITIES
REVIEW LETTER, PLEASE INSTALL THE SEWER LATERALS FOR LOTS 18
AND 19 EITHER TO THE FRONT OR REAR OF THE BUILDING
ENVELOPES. UTILITIES SUGGESTS INSTALLING ONE LATERAL FROM TH
FRONT OF ONE BUILDING ENVELOPE AND ONE LATERAL FROM THE
REAR OF THE OTHER HOWEVER PLEASE DO NOT POSITION THE
LATERALS WITHIN THE FRONT OR REAR SETBACKS.
.
2.SINCE AN IRRIGATION SYSTEM IS NOW BEING PROPOSED, PLEASE
COMPLETE AN IRRIGATION MSF AND ADD THE FORM TO THE PLAN.
BE AWARE THE MAXIMUM ALLOWABLE DEMAND FOR A 5/8"
WATER METER IS 20 GPM.
.
3. PLEASE REVISE THE VERTICAL WATERLINE TRANSITION SHOWN
BETWEEN APPROXIMATELY STA'S 38+00 AND 38+50.
RESTRAINED JOINT CLASS 52 DI PIPE SHOULD BE USED UNDER THE
48" CULVERT PER DETAIL WAT-8 WITH SUITABLE BENDS VERSUS
THE BENDING OF PVC PIPE AS CURRENTLY SHOWN.
.
4. THERE ARE STREET TREES LOCATED DIRECTLY ON TOP OF THE
WM'S FOR LOTS 17, 18, AND 21; PLEASE REVISE THE TREE
LOCATIONS.
.
THE PLAN IS NOW ELIGIBLE FOR A TABLE REVIEW. IT IS
RECOMMENDED REVISED PDF'S BE SUBMITTED TO UTILITIES PRIOR
TO THE TABLE REVIEW TO ENSURE ALL COMMENTS HAVE BEEN
ADDRESSED.
THE OWNER IS REQUIRED TO ENTER INTO A COUNTY UTILITIES
CONTRACT PRIOR TO THE START OF CONSTRUCTION.
.
PLEASE BE MINDFUL THE REQUIRED DRY CREEK WASTEWATER
PUMP STATION PAYMENT, AS DISCUSSED IN THE DECEMBER 20TH
REVIEW LETTER, MUST BE MADE PRIOR TO ISSUANCE OF THE FIRST
BUILDING PERMIT FOR THIS SECTION.
.
NOTE THE SEGMENTS OF OFFSITE EASEMENT ON GRAHAMS FERRY
LANE AND MILL WRIGHT ROAD MUST BE RECORDED SEPARATELY
FROM THE SUBDIVISION PLAT AND PRIOR TO PLAN APPROVAL. A
PLAT SHOULD BE SUBMITTED AS SOON AS POSSIBLE TO KIM PULLEY
IN THE RIGHT-OF-WAY SECTION.
.
AFTER FINAL SITE PLAN APPROVAL, FOUR SETS TOTAL OF THE
APPROVED PLANS MUST BE SENT DIRECTLY TO THE UTILITIES
DEPARTMENT FOR OUR USE DURING CONSTRUCTION INSPECTION.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE #: W.B. PAYNE III/751-4336
NAME OF PLAN: HARPERS MILL SOUTH PHASE SECTION 4
ADDRESS: OTTERDALE ROAD AND VERNEHAM DRIVE
SUBMISSION DATE: 6/21/17
PLAN DATED: 5/30/17
REVIEW DATE: 7/10/17
SITE PLAN NUMBER: 17CP0070
COMMENTS: 3RD REVIEW - NOT APPROVED
TABLE REVIEW: YES
PLAT PROCESS:
1.PLEASE EXTEND THE SEGMENT OF RESTRAINED JOINT DI PIPE,
SHOWN UNDERNEATH THE DOUBLE CULVERT AT STA 38+25, ALL
THE WAY TO THE EXISTING 12" DI CONNECTION POINT.
2.RE: COMMENT #1, UPDATE THE QUANTITIES BY LISTING THE
PVC AND CLASS 52 DI PIPE SEPARATELY.
THE PLAN IS ELIGIBLE FOR A TABLE REVIEW. IT IS RECOMMENDED
REVISED PDF'S BE SUBMITTED TO UTILITIES PRIOR TO THE TABLE
REVIEW TO ENSURE ALL COMMENTS HAVE BEEN ADDRESSED.
THE OWNER IS REQUIRED TO ENTER INTO A COUNTY UTILITIES
CONTRACT PRIOR TO THE START OF CONSTRUCTION.
PLEASE BE MINDFUL THE REQUIRED DRY CREEK WASTEWATER
PUMP STATION PAYMENT, AS DISCUSSED IN THE DECEMBER 20TH
REVIEW LETTER, MUST BE MADE PRIOR TO ISSUANCE OF THE FIRST
BUILDING PERMIT FOR THIS SECTION.
NOTE THE SEGMENTS OF OFFSITE EASEMENT ON GRAHAMS FERRY
LANE AND MILL WRIGHT ROAD MUST BE RECORDED SEPARATELY
FROM THE SUBDIVISION PLAT AND PRIOR TO PLAN APPROVAL. A
PLAT SHOULD BE SUBMITTED AS SOON AS POSSIBLE TO KIM PULLEY
IN THE RIGHT-OF-WAY SECTION.
AFTER FINAL SITE PLAN APPROVAL, FOUR SETS TOTAL OF THE
APPROVED PLANS MUST BE SENT DIRECTLY TO THE UTILITIES
DEPARTMENT FOR OUR USE DURING CONSTRUCTION INSPECTION.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: HARPER'S MILL SOUTH PHASE, SEC 4
CASE NUMBER: 17CP0070
LATEST PLAN DATE: 10/18/2016
DEPT. REC'D. DATE: 12/02/2016
SUBMITTAL NUMBER: ONE
REVIEW DATE: 12/27/2016
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: HARPER'S MILL SOUTH PHASE, SEC 4
CASE NUMBER: 17CP0070
LATEST PLAN DATE: 03/29/2017
DEPT. REC'D. DATE: 04/03/2017
SUBMITTAL NUMBER: TWO
REVIEW DATE: 04/14/2017
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
.
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: HARPER'S MILL SOUTH PHASE, SEC 4 7
CASE NUMBER: 17CP0070
LATEST PLAN DATE: 05/30/2017
DEPT. REC'D. DATE: 06/21/2017
SUBMITTAL NUMBER: THREE
REVIEW DATE: 06/28/2017
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
.
REVIEW DEPARTMENT: PLANNING
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : WHIT KIRTLEY/ 706-7691
PLAN NAME : HARPERS MILL SOUTH SECTION 4
PLAN NUMBER : 17CP0070
ORIGINAL PLAN DATE : 10/18/16
REVIEW DATE : 12/6/16
LATEST SUBMISSION DATE 10/18/16
ACCEPTED DATE: 11/28/16
SUBMITTAL NUMBER : 1
STATUS : CORRECTIONS REQUIRED
TABLE REVIEW : N
1. THE APPROVAL DATE FOR 06TS0161 IS 5/5/15. REVISE
THE NOTES AS APPLICABLE.
2. PROVIDE A NOTES STATING IF THERE ARE OR ARE NOT ANY
RETENTION WALL PRESENT WITHIN THE CONSTRUCTION
PLAN. THEY ARE SHOWN AT LOTS 27 AND 28.
3. THE RETAINING WALL SHALL TO BE EITHER ENTIRELY ON
INDIVIDUAL LOTS TO BE MAINTAINED BY INDIVIDUAL LOT
OWNERS OR ENTIRELY IN OPEN SPACE AND MAINTAINED
BY THE HOA.
4. PROVIDE TREE PROTECTION TAPE FOR THE BUFFER ALONG
OTTERDALE ROAD ON THE PHASE 1 AND 2 E & S. PLANS
TREE PROTECTION TAPE SHALL ALSO BE PLACED TO PROTECT
TREE CANOPY AREAS AS SHOWN ON THE APPROVED TREE
CANOPY PLAN.
5. PROVIDE A NOTE IN THE E&S PHASE II PLANS
6. THE FRONT SETBACK LINE DEPICTED FOR LOT 19 IS NOT
LOCATED WHERE THE LOT ACHIEVES THE REQUIRED
50 FOOT LOT WIDTH
7. THE SOUTHERN SIDE YARD SETBACK DEPICTED FOR
LOT 20 EXCEEDS THE REQUIRED 5 FEET. THIS SETBACK
MAY BE REVISED TO 5 FEET.
8. LABEL THE OPEN SPACES ON ALL SHEETS
9. THE PLAN SHALL REFLECT THE TREE CANOPY AREA AS
APPROVED ON THE OVERALL TREE CANOPY PLAN. BE SURE TO
INCLUDE THE TOTAL SITE AREA, AREA REMOVED FROM
CALCULATION, CANOPY REQUIRED AND PROVIDED
10. ANY AREAS SHOWN TO BE GRADED ON THE GRADING PLAN
SHALL NOT BE UTILIZED FOR TREE CANOPY AREA.
11. ON THE TREE CANOPY PLAN, INCLUDE THE FOLLOWING
NOTE: (LIMITS OF THE TREE CANOPY PRESERVATION AREAS
SHALL BE SHOWN AND LABELLED ON THE SUBDIVISION
PLATS WHERE APPLICABLE. A NOTE SHOULD BE INCLUDED
STATING "TREE CANOPY PRESERVATION AREAS TO REMAIN
UNDISTURBED. NO TREES WITHIN THE TREE CANOPY
PRESERVATION AREAS SHALL BE REMOVED WITHOUT
COUNTY APPROVAL" . SUCH LANGUAGE SHALL ALSO
BE INCLUDED WITHIN THE COVENANTS, RESTRICTIONS,
AND BYLAWS FOR THE SUBDIVISION.)
12. BE SURE TO UPDATE THE E&S PLANS TO MARK THE
CANOPY AREAS WITH TREE PROTECTION TAPE.
13. PROVIDE AN AUTOCAD FILE DEPICTING THE BOUNDARIES
OF THIS CONSTRUCTION PLAN.
LANDSCAPE AND LIGHTING:
14. THE TEXTUAL STATEMENT REQUIRES PERIMETER
LANDSCAPING AROUND ALL DWELLING UNITS. PROVIDE
A LANDSCAPE PLAN THAT DEPICTS TYPICAL UNIT
LANDSCAPING.
15. THE TEXTUAL STATEMENT REQUIRES STREET LIGHTS BE
PROVIDED ALONG EACH SIDE OF THE ROAD. THE LIGHTS
SHOULD BE, AT A MINIMUM, SPACED AT 150' ON EACH SIDE
OF THE STREET EACH SIDE STAGGERED TO ROUGHLY EQUAL
75' ON CENTER. PROVIDE THE HEIGHT AND STYLE OF THE
PROPOSED STREET LIGHT. (PROVIDE CUT SHEETS).
16. PROVIDE A STREET TREE PLAN. STREET TREES SHALL BE
PLANTED 40' ON CENTER.
-----------------------------
REVIEW DEPARTMENT: PLANNING
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : WHIT KIRTLEY/ 706-7691
PLAN NAME : HARPERS MILL SOUTH SECTION 4
PLAN NUMBER : 17CP0070
ORIGINAL PLAN DATE : 10/18/16
REVIEW DATE : 4/27/17
LATEST SUBMISSION DATE: 3/29/17
ACCEPTED DATE: 3/30/17
SUBMITTAL NUMBER : 2
STATUS : CORRECTIONS REQUIRED
.
.
1. REVISE THE NOTE IN THE E&S PHASE II PLANS TO STATE THE
THE FOLLOWING:" TREE PROTECTION TAPE TO BE INSTALLED
TO PROTECH TREE CANOPY AND BUFFER AREAS AS SHOWN ON
SHEET 1.0. ANY DISTURBANCE TO THESE AREAS WILL REQUIRED
A LANDSCAPE PLAN AND BOND.
.
2. LABEL THE TREE PROTECTION TAPE IN THE OPEN SPACE
ADJACENT TO LOT 35.
.
3. THE TREE CANOPY ONLY UTILIZES A PORTION OF THE BUFFER
ADJACENT TO LOT 35. IT WOULD BE BENEFICIAL TO INCLUDE
THE AREA IN THE TREE CANOPY COUNTY TO HELP MAINTAIN
THE REQUIRED 20% OVERALL CANOPY FOR ALL OF HARPERS
MILL SOUTH IN THE EVENT THE OVERALL CANOPY AREA FALLS
BELOW 20% ON THE REMAINING SECTIONS.
.
4. PROVIDE AN AUTOCAD FILE DEPICTING THE BOUNDARIES
OF THIS CONSTRUCTION PLAN.
.
.
LANDSCAPE AND LIGHTING:
.
5. THE ON THE UNIT LANDSCAPING PLAN, EXTEND
THE PLANTING AREA TO THE APPROXIMATE LOCATION
OF THE HVAC UNIT. PROVIDE THIS SAME ON THE
OPPOSITE SIDE OF THE HOUSE.
.
6. ON THE UNIT LANDSCAPING PLAN, IS THE PROPOSED
ACER RUBRUM, MEANT TO BE IN ADDITION TO THE
REQUIRED STREET TREES. IF IT IS THE REQUIRED STREET
TREE, LABEL IT AS SUCH ON THE UNIT PLAN SO AS NOT
CAUSE CONFUSION IN THE AMOUNT OF LARGE TREES
WE ARE LOOKING FOR AN THE INSPECTION PHASE.
.
7. THE LIGHTS SHOULD BE, AT A MINIMUM, SPACED AT
150' ON EACH SIDE OF THE STREET EACH SIDE STAGGERED
TO ROUGHLY EQUAL 75' ON CENTER. ADJUST THE LOCATION
OF THE LIGHTS TO PROVIDE MORE UNIFORM DISTANCE
BETWEEN ON THE SAME SIDE AND DIAGONALLY BETWEEN
LIGHTS. I HAVE PROVIDED AN EXAMPLE OF THE
APPROPRIATE SPACING.
.
8. MOVE THE STREET LIGHT ON LOT 22 AWAY FROM THE
DEPICTED DRIVEWAY ENTRANCE.
.
9. MOVE THE STREET LIGHT ON LOT 18 TO THE ADJACENT
OPEN SPACE.
----------------------------------------------------------
REVIEW DEPARTMENT: PLANNING
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : WHIT KIRTLEY/ 706-7691
PLAN NAME : HARPERS MILL SOUTH SECTION 4
PLAN NUMBER : 17CP0070
ORIGINAL PLAN DATE : 10/18/16
REVIEW DATE : 7/18/17
LATEST SUBMISSION DATE: 6/15/17
ACCEPTED DATE: 6/19/17
SUBMITTAL NUMBER : 3
STATUS : MINOR COMMENTS
TABLE REVIEW : Y
.
.
1. PROVIDE AN AUTOCAD FILE DEPICTING THE BOUNDARIES
OF THIS CONSTRUCTION PLAN PRIOR TO CONSTRUCTION PLAN
APPROVAL.
.
.
LANDSCAPE AND LIGHTING:
.
1. THE UNIT LANDSCAPING PLAN WITH THE REVISIONS FROM
THE PREVIOUS REVIEW WAS NOT INCLUDED IN THIS
LASTEST REVISION. PLEASE SUBMIT COPIES OF THE
UNIT LANDSCAPING PLAN.
.
NOTES:
.
BE ADVISED, THE NEXT SUBMITTAL WILL REQUIRE A FEE
REVIEW DEPARTMENT: FIRE AND LIFE SAFETY
REVIEWER / PHONE#: KIM LESTER / 748-1489
PLAN NAME: HARPERS MILL SOUTH PHASE, SECTION 4
PLAN NUMBER: 17CP0070
LATEST REVISION DATE: 10/18/16
REVIEW DATE: 12/13/16
LATEST SUBMISSION DATE: 12/5/16
SUBMITTAL NUMBER: 1ST REVIEW
STATUS: NOT APPROVED
TABLE REVIEW: NO
SHOW THE LOCATION OF THE PROPOSED HYDRANT ON BLOOMING
ROAD IN HARPERS MILL SOUTH SECTION 2.
RELOCATE THE HYDRANT AT THE PROPERTY LINE OF LOT 2 AND 3 TO
THE PROPERTY LINE OF LOT 4 AND 5.
RELOCATE THE HYDRANT AT LOT 10 TO THE PROPERTY LINE OF LOT
13 AND 14.
RELOCATE THE HYDRANT AT LOT 26 TO THE PROPERTY LINE OF
LOT 23 AND 24.
PROVIDE A COMPUTER GENERATED WATER FLOW TEST DATA,
ALONG WITH THE NODE MAP THAT IS PROVIDED BY THE
CHESTERFIELD COUNTY UTILITIES DEPARTMENT, VERIFYING
THE REQUIRED WATER FLOW FOR FIRE PROTECTION IS AVAILABLE
AT THE SITE THE WATER FLOW TEST RESULTS AND GRAPH SHALL
BE SHOWN ON THE SUBMITTED PLAN. IFC 2012, SECTION B105.1.
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT: FIRE AND LIFE SAFETY
REVIEWER / PHONE#: KIM LESTER / 748-1489
PLAN NAME: HARPERS MILL SOUTH PHASE, SECTION 4
PLAN NUMBER: 17CP0070
LATEST REVISION DATE: 3/29/17
REVIEW DATE: 4/11/17
LATEST SUBMISSION DATE: 4/4/17
SUBMITTAL NUMBER: 2ND REVIEW
STATUS: APPROVED
TABLE REVIEW: YES
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT: FIRE AND LIFE SAFETY
REVIEWER / PHONE#: KIM LESTER / 748-1489
PLAN NAME: HARPERS MILL SOUTH PHASE, SECTION 4
PLAN NUMBER: 17CP0070
LATEST REVISION DATE: 5/30/17
REVIEW DATE: 7/6/17
LATEST SUBMISSION DATE: 6/26/17
SUBMITTAL NUMBER: 3RD REVIEW
STATUS: APPROVED
TABLE REVIEW: YES
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
============================================================
============================================================
REVIEW DEPARTMENT : ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE # : ADAM MARSHALL, P.E. (717-6711)
NAME OF PLAN : HARPERS MILL SOUTH PHASE - SECTION 4
SITE PLAN NO. : 17CP0070
LATEST PLAN DATE : 11/10/16
DEPT. REC'D DATE : 12/02/16
SUBMITTAL NUMBER : 1
REVIEW DATE : 01/03/17
RECOMMENDATION : REVISIONS REQUIRED
TABLE REVIEW : NO
-------- GENERAL NOTES --------
001. THE RESPONSIBILITY FOR COMPLIANCE WITH CHESTERFIELD
COUNTY STANDARDS AND POLICIES, AND WITH STATE AND
FEDERAL REGULATIONS WILL BE PLACED ON THE PROFESSIONAL
ENGINEER WHO SIGNS AND SEALS THE CONSTRUCTION PLANS
APPROVED.
002. THE RESPONSIBILITY FOR ACHIEVING AND MAINTAINING
SATISFACTORY LOT DRAINAGE WILL BE THAT OF THE DEVELOPER
UP THROUGH A PERIOD OF ONE YEAR AFTER STATE ACCEPTANCE
OF THE SUBDIVISION ROADS.
-------- EROSION CONTROL --------
001. PRIOR TO A LAND DISTURBANCE PERMIT ISSUANCE:
A) CONSTRUCTION PLANS RECEIVE FINAL PLANNING DEPARTMENT
APPROVAL.
B) THE ENVIRONMENTAL ENGINEERING DEPARTMENT SHALL
REQUIRE COPIES OF APPLICABLE CORRESPONDENCE FROM THE
U.S. ARMY CORPS OF ENGINEERS AND DEPARTMENT OF
ENVIRONMENTAL QUALITY SUCH THAT IT MAY BE DETERMINED
THAT ANY REQUIRED WETLANDS PERMITS HAVE BEEN
RECEIVED.
C) A COPY OF THE PROCESSED VSMP REGISTRATION AND FEE
FORM MUST BE RECEIVED BY ENVIRONMENTAL ENGINEERING.
D) AN EROSION CONTROL BOND MUST BE POSTED AND APPROVED.
E) COPIES OF THE ACTUAL VDOT LAND USE PERMIT(S) FOR THE
TIE-IN TO VERNEHAM DRIVE (IF IN THE STATE
SYSTEM AT THE TIME OF LDP APPLICATION) MUST BE
PROVIDED TO ENVIRONMENTAL ENGINEERING.
F) FLAGGING AND/OR SAFETY FENCE AROUND USACOE
JURISDICTIONAL WETLANDS AND/OR OTHER ENVIRONMENTALLY
SENSITIVE AREAS MUST BE INSTALLED AND CLEARLY
VISIBLE.
G) DB/PG FOR ANY OFFSITE EASEMENTS MUST BE PROVIDED TO
ENVIRONMENTAL ENGINEERING.
H) PRIOR TO ISSUANCE OF A LAND DISTURBANCE PERMIT, A
COPY OF THE AUTOCAD FILE MUST BE SUBMITTED TO
CAROLE CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE
AUTOCAD FILE MUST BE SAVED AS A .DWG OR .DXF IN
AUTOCAD VERSION 2009 OR EARLIER AND REFERENCED
DIRECTLY TO THE VIRGINIA STATE PLANE COORDINATE
SYSTEM, SOUTH ZONE IN THE NAD83 DATUM. THE AUTOCAD
FILE MAY BE SUBMITTED ON A CD, DVD, OR VIA EMAIL
AND MUST BE CLEARLY LABELED WITH THE SUBDIVISION
NAME AND SECTION, SUBDIVISION PLAN NUMBER, THE
ENGINEERING FIRM AND THE CAD FILE PREPARER'S NAME
AND PHONE NUMBER. THE FILE MUST CONTAIN THE
FOLLOWING, EACH CLEARLY LABELED IN SEPARATE LAYERS:
1. EDGES OF ROADS TO INCLUDE CURB AND GUTTER; AND,
2. EDGES OF SIDEWALKS.
I) PROVIDE A COPY OF THE SWPPP BOOKLET (THREE-RING
BINDER) TO ENVIRONMENTAL ENGINEERING.
002. GHOST THE ROAD LAYOUT ON SHEET C2.0, AND INCLUDE
STATIONING.
003. SPECIFY A CONSTRUCTION ENTRANCE OFF OF VERNEHAM DRIVE,
AND REMOVE THE CONSTRUCTION ENTRANCE AT BLOOMING ROAD
VIA SECTION 2. ADD LANGUAGE TO NOTE 9 ON SHEET C2.0
STATING THAT ALL CONSTRUCTION TRAFFIC SHALL ENTER/EXIT
THE SITE VIA VERNEHAM DRIVE.
004. SPECIFY A RWD TO BE INSTALLED DURING EC PHASE I ACROSS
BLOOMING ROAD, TYING INTO THE PROPOSED DD WHICH DRAINS
INTO THE SEDIMENT BASIN.
005. PROVIDE CONTOUR LABELS FOR THE SEDIMENT BASIN GRADING
ON BOTH EC PLAN SHEETS.
006. LABEL THE SEDIMENT BASIN DRAINAGE AREA ON THE EC PLAN
SHEETS.
007. LABEL THE WOUS, WETLANDS, CONSERVATION EASEMENT, 100-
YEAR FLOODPLAIN, ALL SECTION 2 LOTS, AND ALL EXISTING
EASEMENTS ON THE EC PLAN SHEETS.
008. IT APPEARS THAT THERE IS CLEARING AND SSF PROPOSED
WITHIN THE LIMITS OF THE CONSERVATION EASEMENT. PLEASE
ADDRESS. ALSO NOTE THAT THIS CLEARING FALLS WITHIN THE
100' ZONING BUFFER.
009. SHOW THE OUTLET PROTECTION AT THE BASIN BARREL OUTFALL
ON THE EC PLAN SHEETS.
010. REMOVE THE DEPICTION OF THE FUTURE R/W FROM THE EC
PLANS.
011. SPECIFY SSF TO BE INSTALLED DURING EC PHASE I UPSTREAM
OF THE EXISTING SECTION 2 LOT.
012. PROVIDE AN ENLARGED BASIN RECLAMATION GRADING PLAN (1'
CONTOURS) ON SHEET C2.1. INCLUDE NOTES REFERENCING THE
PLACEMENT OF CONTROLLED FILL IN 6-8" LIFTS AT 95%
COMPACTION.
013. LABEL ALL STORM STRUCTURES ON SHEET C2.1.
014. SPECIFY IP AT STRUCTURE 3-13 ON SHEET C2.1.
015. IN THE PROJECT DESCRIPTION SECTION OF THE EC NARRATIVE,
INCLUDE REFERENCE THAT THIS PROJECT IS IN THE SOUTH
PHASE.
016. IN THE OFF-SITE AREAS SECTION, NOTE THE SOIL STOCKPILE
AS AN OFF-SITE AREA.
017. IN THE CRITICAL AREAS SECTION, INCLUDE WOUS AND THE
CONSERVATION EASEMENT.
018. PROVIDE STD. & SPEC. REFERENCES FOR ALL MEASURES NOTED
IN THE EROSION AND SEDIMENT CONTROL MEASURES SECTION.
019. IN THE CALCULATIONS SECTION, INCLUDE REFERENCES TO THE
SEDIMENT BASIN AND STORM SEWER CALCULATION LOCATIONS.
020. PROVIDE THE ACTUAL DESIGN DIMENSIONS (RISER, BARREL,
TRASH RACK, DEWATERING ORIFICE AND TUBING) IN ALL
SEDIMENT BASIN DETAILS ON SHEET C2.3.
021. IT IS UNCLEAR WHETHER THE BARREL PIPE IS INTENDED TO BE
RCP OR CMP, AS THERE ARE CONFLICTING SPECIFICATIONS IN
THE PLAN SET. PLEASE ADDRESS
022. IT APPEARS THAT BAFFLES WILL BE REQUIRED IN ORDER FOR
THE 2:1 LENGTH:WIDTH RATIO TO BE MET FOR THE SOUTHERN
INFLOW POINT. PLEASE ADDRESS, AND INCLUDE THE BAFFLE
DETAIL IN THE EC PLANS.
023. PROVIDE THE EMERGENCY SPILLWAY DETAIL WITH DIMENSIONS.
024. PROVIDE AN ELEVATION-VOLUME TABLE FOR THE SEDIMENT
BASIN DESIGN.
025. THE MS-19 ANALYSES FOR SECTION 4 SHOULD BE PERFORMED
INDEPENDENTLY FROM SECTION 2, AND SHOULD BE PROVIDED AT
THE FOLLOWING LOCATIONS:
- TIE-IN TO STORM STRUCTURE 1-21 (10-YEAR);
- IN THREE LOCATIONS ALONG THE SOUTHERN DRAINAGEWAY,
AT APPROXIMATELY THE LOCATIONS OF FLOODPLAIN
SECTIONS SL-1, SL-4, AND SL-7 (HOWEVER, ENSURE
THESE SECTIONS ARE SHOWN/LABELED WITH SEPARATE
"MS-19" SECTION REFERENCES. FURTHER DISCUSSION MAY
BE HELPFUL.
026. ON SHEET C4.2, THE DEPICTION AND INCLUSION IN THE TABLE
OF ANY SECTION 2 MS-19 ANALYSES MAY BE REMOVED, AND THE
DRAINAGE AREAS SHOULD BE REPRESENTATIVE OF THE MS-19
LOCATIONS NOTED IN THE PREVIOUS COMMENT.
027. LABEL THE TIME OF CONCENTRATION FLOW PATH, WITH
BREAKDOWNS OF OVERLAND AND CHANNEL FLOW.
028. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND/OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR STATE
PERMITS IN RELATION TO ENVIRONMENTAL FEATURES
INCLUDING, BUT NOT LIMITED TO, WETLANDS, SURFACE WATER,
GROUND WATER, AND AIR QUALITY. FINAL APPROVAL OF THESE
PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILITIES.
-------------- CBPA ---------------
001. PROVIDE A MORE UP-TO-DATE VERSION OF THE OVERALL CBPA
COMPLIANCE EXHIBIT SHEET, WHICH SHOWS ONLY THE SECTIONS
OF HARPERS MILL THAT HAVE BEEN SUBMITTED AS OF THE DATE
OF THIS SUBMITTAL. FUTURE SECTIONS/PHASES SHOULD BE
REMOVED FROM THE TABLE AND THE LOT/ROAD LAYOUT FOR
FUTURE SECTIONS SHOULD ALSO BE REMOVED FROM PLAN VIEW.
REFER TO SHEET C8.1 OF THE HARPERS MILL SOUTH PHASE
SECTION 2 PLANS FOR A MORE RECENT TEMPLATE. FURTHER
DISCUSSION MAY BE HELPFUL.
002. IN THE TABLE ON SHEET C8.1, THE AREAS LISTED FOR
HARPERS MILL SOUTH SECTIONS 2 AND 4 SHOULD REPRESENT
EACH INDIVIDUAL SECTION, AND BMP #3 SHOULD ONLY BE
LISTED WITH SECTION 2. FURTHER DISCUSSION MAY BE
HELPFUL.
003. IN THE WORKSHEET A CALCULATIONS ON SHEET C8.0, IT
APPEARS THAT THE SITE AREA USED IS THAT OF SECTION 2
INSTEAD OF THIS SECTION. PLEASE ADDRESS.
004. THE METHODOLOGY USED TO DETERMINE THE IMPERVIOUS
AREA/PERCENTAGE FOR THIS SUBDIVISION SECTION, AS WELL
AS FOR THE BMP DRAINAGE AREA, NEEDS TO MATCH THAT WHICH
WAS USED IN THE SECTION 2 WORKSHEET A CALCULATIONS, AND
A FULL BREAKDOWN OF THE IMPERVIOUS AREA DETERMINATION
NEEDS TO BE PROVIDED FOR REVIEW. NOTE THAT ANY CHANGES
TO THE BMP DESIGN INFORMATION WOULD ALSO NEED TO BE
APPLIED TO THE SECTION 2 CALCULATIONS AND PLANS. THE
MOST RECENT SECTION 2 PLANS NOTE A BMP 3 I% OF 45% IN
LIEU OF 47%, WITH AN FPOST OF 1.08 AND LPOST OF 21.73
LBS/YR. PLEASE ADDRESS. FURTHER DISCUSSION MAY BE
HELPFUL.
005. IN THE CBPA/MS-4 TABLE ON SHEET C8.0, REVISE THE BMP
TYPE TO "WET POND DESIGN 6 WITH PLANTED AQUATIC BENCH".
006. REVISE THE BMP SERVICE AREA TO READ "SOUTH PHASE,
SECTIONS 2 AND 4".
007. COMPLETE THE SURFACE AREA AND BMP VOLUME ROWS OF THE
CBPA/MS-4 TABLE.
008. REVISE THE NOTE BENEATH THE CBPA/MS-4 TABLE TO REMOVE
REFERENCE TO "CBPA AND MS-14" AT THE BEGINNING.
009. INCLUDE LANGUAGE REFERENCING HOW VSMP PART II.C
COMPLIANCE IS ACHIEVED FOR THIS SECTION, IN THE CBPA
NOTE ON THE COVER SHEET. REFERENCE THE PERMIT NUMBER
AND EFFECTIVE DATES.
-------- ROAD AND DRAINAGE --------
001. OUR CONCERNS ARE BASED ON THE INFORMATION SHOWN IN THE
CONSTRUCTION PLANS. THE RESPONSIBILITY FOR IDENTIFYING
CRITICAL AREAS IS PLACED ON THE PROFESSIONAL ENGINEER
WHO SEALS THE CONSTRUCTION PLANS APPROVED. WE RESERVE
THE RIGHT TO INSPECT CONVEYANCE SYSTEMS PRIOR TO PLAT
RECORDATION AND/OR STATE ACCEPTANCE TO DETERMINE IF
ADDITIONAL IMPROVEMENTS ARE REQUIRED.
002. PROVIDE SIGNED DOCUMENTATION FROM THE GEOTECHNICAL
PROFESSIONAL WHICH ADDRESSES MINING ACTIVITIES (OR
LACK THEREOF) SPECIFIC TO THIS SECTION, AND REVISE THE
NOTE ON THE COVER SHEET TO REFERENCE THIS
DOCUMENTATION AS PER TENTATIVE CONDITION 14.
003. REVISE THE TENTATIVE APPROVAL DATE ON THE COVER SHEET
TO READ "5/5/15".
004. IT APPEARS THAT THE LATITUDE FOR THE APPROXIMATE CENTER
OF THIS SECTION MAY BE INCORRECT ON THE COVER SHEET.
PLEASE ADDRESS.
005. UPDATE THE ROAD NAMES IN SOUTH PHASE SECTION 1 AS PER
THE MOST RECENT TENTATIVE ON SHEET C1.0.
006. LABEL THE INDIVIDUAL SOUTHEAST PHASE SECTIONS ON SHEET
C1.0.
007. LABEL THE SECTION 2 SWM/BMP ON SHEET C1.0.
008. LABEL SOUTH PHASE SECTION 2 AND SOUTHEAST PHASE SECTION
2 ON SHEET C3.0.
009. SHOW AND LABEL (AND PROVIDE DB/PG FOR, AS APPLICABLE)
ALL EASEMENTS ALONG OTTERDALE ROAD AND IN SOUTH PHASE
SECTION 2, AS WELL AS THE SLOPE & DRAINAGE EASEMENTS
ALONG VERNEHAM DRIVE AS PER THE SOUTHEAST PHASE SECTION
2 PLANS.
010. LABEL ALL WOUS AND WETLAND AREAS ON SHEETS C3.0 AND
C4.0.
011. SHOW AND LABEL THE CONSERVATION EASEMENT LIMITS ON
SHEETS C3.0 AND C4.0.
012. CLEARLY LABEL ALL OPEN SPACE AREAS ON SHEETS C3.0 AND
C4.0.
013. LABEL THE EXISTING SIDEWALK ALONG VERNEHAM DRIVE AND
BLOOMING ROAD ON SHEET C3.0.
014. LABEL THE SOUTHEAST PHASE ROADS ON SHEETS C3.0 AND
C4.0.
015. EITHER REMOVE OR RELOCATE THE PROPOSED RETAINING WALLS
SUCH THAT THEY DO NOT FALL WITHIN LOTS 27 OR 28. IF
THE RETAINING WALLS REMAIN A PART OF THE DESIGN,
PROVIDE DETAILS FOR THE CONSTRUCTION OF THE WALLS WHICH
INCLUDE HOW DRAINAGE AT THE TOP AND BOTTOM THE WALLS IS
ADDRESSED, AS WELL AS ANY WEEP DRAINS, ETC. A BOLD
NOTE SHOULD ALSO BE PROVIDED ON SHEET C3.0 STATING THAT
THE OWNERSHIP AND MAINTENANCE OF THE WALLS ARE THE
RESPONSIBILITY OF THE HOMEOWNERS ASSOCIATION. FURTHER
DISCUSSION MAY BE HELPFUL.
016. AS CURRENTLY PROPOSED, THERE IS A STEEP AREA OF GRADING
WHICH DRAINS DIRECTLY FROM LOT 27 INTO LOT 26, WHICH IS
NOT ALLOWABLE. PLEASE REVISE.
017. PROVIDE GRADING FOR SWALES BETWEEN LOTS 31/32/33/34
SUCH THAT EACH LOT MAY DRAIN INDEPENDENTLY.
018. SPECIFY A 3:1 DITCH, OR COMBINATION OF DITCH AND DI-6
INLET/PIPE, ALONG THE REAR OF LOTS 1-18 TO ENSURE THAT
DRAINAGE FROM LOTS 1-10 DOES NOT RUN INTO LOTS 11-18
BUT INSTEAD IS CONVEYED IN THE DIRECTION OF STORM
STRUCTURE 3-11. THE DRAINAGE IMPROVEMENTS SHOULD BE
ALIGNED WITHIN THE OPEN SPACE AREAS WHERE AVAILABLE,
AND SHOULD BE ENCLOSED IN A 16' DRAINAGE EASEMENT.
NOTE THAT THIS WOULD USUALLY BE A SCENARIO IN WHICH
"MAINTENANCE-FREE" IMPROVEMENTS (I.E. PAVED DITCH
AND/OR CONCRETE INLETS AND PIPE) WOULD TYPICALLY BE
REQUIRED. FURTHER DISCUSSION MAY BE HELPFUL.
019. SIMILARLY, SPECIFY A 3:1 DITCH AND DI-6 INLET/PIPE
DRAINAGE IMPROVEMENTS ALONG THE REAR OF LOTS 35-44 TO
AVOID CROSS-LOT DRAINAGE FROM THE FUTURE SOUTH PHASE
SECTION INTO THESE LOTS. DI-6 STRUCTURES MAY BE NEEDED
AT THE REAR (NORTHERN) CORNER OF LOT 44, AND AT THE
REAR OF LOTS 36/37, TO CAPTURE AND CONVEY STORMWATER IN
THE DIRECTION OF STORM PIPE 3-16. FURTHER DISCUSSION
MAY BE HELPFUL.
020. AS PREVIOUSLY DISCUSSED RE: SOUTH PHASE SECTION 2,
REMOVE THE DEPICTION OF THE BUILDING FOOTPRINTS FROM
THE GRADING AND DRAINAGE AREA PLAN SHEETS, AND INSTEAD
SHOW THE LOT GRADING FOR WHICH THE DEVELOPER WILL BE
RESPONSIBLE PRIOR TO THE ISSUANCE OF BUILDING PERMITS
ON THE LOTS. ADDITIONALLY, REVISE THE INCREMENTAL
DRAINAGE AREA BOUNDARIES TO REFLECT THE GRADING
PROPOSED IN THE PLAN SET, INDEPENDENT OF THE BUILDINGS.
FURTHER DISCUSSION MAY BE HELPFUL.
021. REALIGN THE SWALE TO THE WEST OF LOT 1 SUCH THAT IT IS
LOCATED OUTSIDE OF THE LOT AND FALLS WITHIN THE OPEN
SPACE AND DRAINAGE EASEMENT INSTEAD.
022. UPDATE THE GRADING SHOWN FOR SOUTH PHASE SECTION 2 ON
ALL GRADING AND DRAINAGE AREA PLANS.
023. PROVIDE THE GRASS 5:1 SIDEYARD SWALE TYPICAL SECTION ON
SHEET C4.0, ALONG WITH A NOTE STATING THAT SWALES SHALL
BE CONSTRUCTED ALONG THE LOT LINE BETWEEN EACH LOT, AND
THAT ALL SWALES SHALL FLATTEN TO SHEET FLOW PRIOR TO
DISCHARGING INTO THE R/W OR OPEN SPACE, UNLESS
OTHERWISE SPECIFIED.
024. SHOW THE LOCATION AND ELEVATION OF ALL 100-YEAR
FLOODPLAIN CROSS-SECTIONS ON SHEETS C3.0, C4.0, AND
C4.1.
025. LABEL THE 100-YEAR FLOODPLAIN LIMITS ON SHEETS C3.0,
C4.0, C4.1, AND SHEET C5.3 (ENSURE THIS SHEET GETS
INCORPORATED INTO SUBSEQUENT PLAN SET SUBMITTALS).
026. SHOW AND LABEL THE INCREMENTAL DRAINAGE AREA TO
STRUCTURE 1-22 ON SHEET C4.1. ENSURE THE PORTION OF
GRAHAMS FERRY LANE WHICH DRAINS IN ITS DIRECTION IS
SHOWN ACCURATELY (HIGH POINT AT APPROX. STA. 1+66 PER
THE PROFILE).
027. LABEL THE CONSTRUCTION START/END STATIONS ON THE
BLOOMING ROAD PROFILE.
028. SHOW AND LABEL THE EXISTING SECTION 2 STORM SEWER ON
THE BLOOMING ROAD PROFILE.
029. ADJUST THE PROPOSED LOT GRADING SHOWN ON THE ROAD/STORM
PROFILES AS PER COMMENT #020 ABOVE.
030. IT APPEARS THAT THE INTERSECTION ELEVATION FOR BLOOMING
ROAD AND SHARPE COURT NOTED ON BOTH OF THESE PROFILES
IS INCORRECT (LISTED AS 217.82'). PLEASE REVISE.
031. LABEL THE END CONSTRUCTION STATION ON THE GRAHAMS FERRY
LANE PROFILE, AND CLEARLY DISTINGUISH BETWEEN PROPOSED
AND FUTURE GRADES.
032. PROVIDE A STORM SEWER PROFILE FOR STRUCTURES 3-1 TO
3-3.
033. SHOW AND LABEL THE SLOT OPENINGS AND ASSOCIATED 2'
CONCRETE GUTTERS ON THE DITCH 1 AND STORM 3-9 PROFILES,
AND SHOW THE DITCH/SWALE FLOWLINES TYING INTO THE SLOT
OPENINGS INSTEAD OF THE TOP OF THESE DI-6 STRUCTURES.
034. REVISE THE CROSS-SECTION ON THE DITCH 1 PROFILE TO
REFLECT 3:1 SIDESLOPES ON BOTH SIDES OF THE DITCH.
035. DISTINGUISH BETWEEN THE SECTION 2 (EXISTING) AND
PROPOSED SECTION 4 STRUCTURES ON SHEET C6.0.
036. PROVIDE THE TIME OF CONCENTRATION DETERMINATIONS FOR
EACH INCREMENTAL DRAINAGE AREA (STORM SEWER, MS-19,
ETC.) FOR REVIEW.
037. PROVIDE THE STRUCTURE NUMBER (3-11) ON THE DI-6 DETAIL
ON SHEET C7.2.
038. AS IT APPEARS THAT THERE ARE MANY STRUCTURE WHICH THE
HGL ESCAPES DURING THE 100-YEAR STORM, PROVIDE 100-YEAR
SURCHARGE CALCULATIONS FOR EACH STRUCTURE HANDLING
UPSTREAM OVERFLOW. SPECIFY AN OVERFLOW SWALE BETWEEN
LOTS 18/19 TO CARRY THE HGL OVERFLOW TO THE WETLAND
DRAINAGEWAY TO THE REAR OF THESE LOTS.
039. IN THE 100-YEAR FLOODPLAIN CALCULATIONS, REVISE THE
DRAINAGE AREAS, RUNOFF COEFFICIENTS, AND TIMES OF
CONCENTRATION TO REPRESENT THE ULTIMATE DEVELOPMENT
SCENARIO. FURTHER DISCUSSION MAY BE HELPFUL.
040. IT APPEARS THAT THE REQUIRED 1.25X SATURATION FACTOR
HAS NOT BEEN INCLUDED IN THE 100-YEAR FLOODPLAIN
CALCULATIONS. PLEASE REVISE.
041. IN THE FLOWMASTER WORKSHEETS FOR THE FLOODPLAIN CROSS-
SECTIONS, THE MANNING'S COEFFICIENT OF 0.030 SHOULD
ONLY BE USED TO REPRESENT THE NARROW BED/BANK CHANNEL
CROSS-SECTION, IF PRESENT. ANYTHING OUTSIDE OF THE
BED/BANK CHANNEL SHOULD BE MODELED WITH A HIGHER
COEFFICIENT THAT IS MORE REPRESENTATIVE OF A FLOODPLAIN
OVERBANK AREA (MINIMUM 0.065 BUT POTENTIALLY IN THE
RANGE OF 0.10 AS DETERMINED BASED ON FIELD CONDITIONS.
FURTHER DISCUSSION MAY BE HELPFUL.
042. PER TENTATIVE CONDITION 7, THE WETLANDS MAP WHICH
ACCOMPANIES THE CORPS DETERMINATION MUST BE PROVIDED TO
EE PRIOR TO CONSTRUCTION PLAN APPROVAL.
043. PROVIDE A WRITTEN RESPONSE IN THE MARGIN OF A COPY OF
THESE REVIEW COMMENTS WITH YOUR NEXT PLAN SUBMITTAL.
DESIGN, DETAIL AND CALCULATIONS REQUIRED BY THE ABOVE
COMMENTS SHALL BE SUBJECT TO FURTHER REVIEW.
---- END OF ENV. ENG. COMMENTS ----
============================================================
============================================================