Subdivision Review Comments
All Subdivision Review Comments for Case # 16CP0045




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 16CP0045 STATUS: PENDING APPROVAL
PROJECT NAME: POPLAR VILLAGE - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: CONSTRUCTION PLAN
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ENVIR.ENGR.-: 02 11/17/17 12/13/17 ******** 05/04/17 GT 706-2061
FIRE DEPT.--: 02 11/17/17 12/13/17 ******** 04/18/17 JKL 748-1489
PLANNING----: 02 11/17/17 12/13/17 ******** 05/15/17 JJD 717-6191
TRANSPORT.--: 02 11/17/17 12/13/17 ******** 05/02/17 SES 751-4912
UTIL.PLAN.--: 02 11/17/17 12/13/17 ******** ********
UTILITIES---: 02 11/17/17 12/13/17 ******** 04/18/17 WBV 748-1343
UTIL.R.O.W.-: 02 11/17/17 12/13/17 ******** ********
VDOT--------: 02 11/17/17 12/13/17 ******** ********
REVIEW DEPARTMENT: UTILITIES
REVIEW/PHONE #: BILL VIER/748-1343
PLAN NAME: POPLAR VILLAGE
PLAN NUMBER: 16CP0045
ORIGINAL PLAN DATE: 10/7/15
REVIEW DATE: 12/21/15
LATEST SUBMISSION DATE: 12/11/15
SUBMITTAL NUMBER: 1
STATUS: REVISIONS REQUIRED
TABLE REVIEW: NO
IN REGARD TO YOUR SUBMITTAL OF UTILITIES PLANS FOR THE
ABOVE REFERENCED PROJECT DATED OCTOBER 7, 2015, WE MAKE
THE FOLLOWING COMMENTS AND RECOMMENDATIONS:
1. A COPY OF VIRGINIA DEPARTMENT OF TRANSPORTATION'S
APPROVAL LETTER REGARDING PAVEMENT REPLACEMENT, METHOD
OF CROSSING, AND ALIGNMENT OF UTILITY WITH STATE RIGHT
OF WAY, AND A COPY OF ENVIRONMENTAL ENGINEERING'S
INITIAL REVIEW LETTER MUST BE SUBMITTED BEFORE REVISED
PLANS ARE SUBMITTED FOR RE-REVIEW.
2. PRIOR TO RELEASING TO THE CONSTRUCTION SECTION, A
COPY OF THE ENVIRONMENTAL ENGINEERING APPROVAL LETTER
AND/OR ALL OTHER APPLICABLE LOCAL STATE AND FEDERAL
AGENCIES' APPROVAL LETTERS MUST BE RECEIVED BY THIS
DEPARTMENT. IN ADDITION, ALL EASEMENTS NOT INCLUDED
WITH THE SUBDIVISION PLAT MUST BE DEDICATED WITH A
SEPARATE PLAT AND AGREEMENT TO THE COUNTY PRIOR TO
RELEASING THE PROJECT TO THE CONSTRUCTION SECTION.
3. SHOW THE COUNTY PROJECT NUMBER 04-0378 ON THE
LOWER RIGHT HAND CORNER OF EACH SHEET.
4. PROVIDE CALCULATIONS TO VERIFY THAT THE FIRE FLOW
AND DOMESTIC FLOWS CAN BE SUSTAINED WITH A RESIDUAL
PRESSURE OF 20 PSI.
5. REVISE THE SCALE OF THE PLAN VIEW TO 1" = 50'.
6. ALL DRAWING FEATURES AND TEXT IS TO BE SHOWN WITH A
"DARK" LINE TYPE (I.E. NO "GRAY" OR "GHOSTED" LINE
TYPES).
7. FIELD VERIFY THE TOP AND ALL INVERT ELEVATIONS OF
THE PROPOSED TIE-IN MANHOLE, REFLECTING THE FIELD DATA
ON THE PLANS.
8. PROVIDE A NOTE IN EACH OF THE PLAN AND PROFILE
VIEWS STATING THAT EXISTING MANHOLE NUMBER 7032A-26 IS
TO BE CORE DRILLED AND A KOR-N-SEAL GASKET IS TO BE
INSTALLED.
9. PROVIDE ALL INVERT ELEVATIONS AT EACH MANHOLE IN
THE PROFILE VIEWS.
10. SPECIFY 1 VF OF ADDITIONAL STONE ABOVE THE PIPE AT
ALL LOCATIONS WHERE THERE IS GREATER THAN OR EQUAL TO 14
VF OF COVER OVER A PVC SEWER LINE NOTING AS SUCH AT EACH
APPLICABLE LOCATION IN THE PROFILE VIEWS.
11. CHECK ALL SANITARY SEWER SLOPE CALCULATIONS FOR
ACCURACY, REVISING AS NECESSARY.
12. THERE APPEARS TO BE < 1.5 VF CLEARANCE AT EACH OF
THE SEWER CONNECTIONS FOR LOT NUMBERS 7 AND 27 WHERE
EACH CROSSES THE WATERLINE. REVISE AS NECESSARY TO
PROVIDE AT LEAST 1.5 VF SEPARATION AT EACH LOCATION.
13. SHOW THE EXISTING 15" SEWER PIPE IN THE PROFILE
VIEW AND MATCH THE EXISTING AND PROPOSED PIPE CROWN
ELEVATIONS.
14. FIELD VERIFY THE LOCATION OF THE EXISTING 8"
WATERLINE PROPOSED TO TIE INTO, REFLECTING THE FIELD
LOCATION ON THE PLANS.
14. THOROUGHLY EXAMINE ALL SHEETS TO CORRECT ALL
EXTRANEOUS MARKINGS, OVERLAPPING TEXT, ILLEGIBLE TEXT
AND DRAWING FEATURES, ETC. IN ORDER TO FACILITATE A
CLEAN DRAWING WITH ALL TEXT AND DRAWING FEATURES
COMPLETELY LEGIBLE AND ABUNDANTLY VISIBLE.
15. REVISE THE "MATERIALS LIST" AS NECESSARY.
PLEASE MAKE ALL OF THE SUGGESTED CHANGES AND SUBMIT
ONE (1) SET OF REVISED PLANS.
THE OWNER MUST ENTER INTO A COUNTY CONTRACT PRIOR TO THE
START OF CONSTRUCTION. PLEASE SEND ME A COPY OF THE
"ACCEPTED" BID PROPOSAL BETWEEN THE DEVELOPER AND THE
CONTRACTOR SO WE MAY PREPARE THE COUNTY CONTRACT. THE
BID PROPOSAL MUST BE BASED ON THE LATEST REVISED
UTILITIES PLANS REFLECTING THE REVIEWER'S STAMP, AND ALL
WORK MUST BE PERFORMED BY AN ACCEPTABLE UTILITIES
CONTRACTOR. IF PLANS ARE REVISED AFTER CONTRACT
PREPARATION DUE TO A CHANGE BECAUSE OF VIRGINIA
DEPARTMENT OF TRANSPORTATION'S AND/OR ENVIRONMENTAL
ENGINEERING DEPARTMENT'S APPROVAL OF THE ROAD, DRAINAGE,
AND EROSION CONTROL DESIGN OR BECAUSE OF STATE AGENCIES'
REVIEW AND APPROVAL OF THE UTILITIES DESIGN, A REVISED
BID PROPOSAL MAY BE NECESSARY TO ACCURATELY REFLECT THE
LATEST UTILITIES DESIGN AND A NEW CONTRACT PREPARATION
MAY BE NECESSARY AND EXECUTED PRIOR TO THE START OF
CONSTRUCTION.
IF YOU HAVE ANY QUESTIONS, DO NOT HESITATE TO CONTACT ME
AT 748-1343.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
.
REVIEW DEPARTMENT: UTILITIES
REVIEW/PHONE #: MIKE LARSON/748-1338
PLAN NAME: POPLAR VILLAGE
PLAN NUMBER: 16CP0045
ORIGINAL PLAN DATE: 10/7/15
REVIEW DATE: 4/18/17
LATEST SUBMISSION DATE: 4/12/17
SUBMITTAL NUMBER: 2
STATUS: NOT APPROVED
TABLE REVIEW: NO
1. SHEET C-1, COUNTY UTILITY NOTES #12. THE ELEVATION BELO
W WHICH A PRV IS REQUIRED IS 122. PLEASE LABEL ANY
LOT WHERE THIS APPLIES WITH "PRV". THIS MAY APPLY TO LOT 16
OR 17 DEPENDING ON THE LOCATION OF THE HOUSE.
2. SHEET C-1, COUNTY UTILITY NOTES #17 A. DELETE THIS LINE
* CONCRETE SEWER IS NOT ALLOWED.
3. SHEET C-1, CHANGE THE NAME OF SHEET C-14 TO DRAINAGE ARE
* ANALYSIS
4.CALCULATE AND LABEL ON THE PLANS A MINIMUM FINISHED FLOOR
*OR SANITARY SEWER (MFF-SAN) FOR LOTS 5-7, 16, 21-25, AND 29
-32.
5. THE APPROVED TENTATIVE PLAT SHOWS A SANITARY SEWER EASEM
ENT WITH CONSTRUCTION EASEMENT BETWEEN LOTS 8 AND
9, BUT THIS IS ABSENT ON THE CONSTRUCTION PLANS.
PROVIDE SANITARY SEWER EASEMENTS AS NECESSARY ALLOW A SEWER
*XTENSION TO SERVE 4249 CURTIS ST, 12515 S. CHESTER RD, AND
12511 S. CHESTER RD. WE RECOMMEND THAT PUBLIC SANITARY SEWE
R MUST BE EXTENDED BEYOND THE BUILDING LOT ENVELOPE WITH AN
M.J. PLUG SET IN ORDER TO MINIMIZE DISTURBANCE.
6. THERE SHOULD BE 10 FT OF HORIZONTAL SEPARATION BETWEEN T
*E WATER AND SEWER ON POPLAR VILLAGE PLACE.
7. PROVIDE A NOTE THAT THE FIRE HYDRANT ON POPLAR VILLAGE P
*ACE IS TO BE SET WITH 3 FT CLEAR SPACE BETWEEN THE CURB AND
STORM DRAIN.
8. THE WATER SERVICE FOR LOT 31 CONFLICTS WITH THE STORM DR
*P INLET, PLEASE RELOCATE IT TO THE OTHER PROPERTY LINE.
9. PLEASE VERIFY THAT THE WATER LINE RADIUS FOR THE 8" PVC
*AIN NEAR STA 12+00 ON POPLAR VILLAGE DR IS GREATER THAN 326
.3 FT.
10. PLEASE VERIFY THAT THE WATER LINE RADIUS FOR THE 6" PVC
*MAIN IN THE CUL-DE-SAC OF POPLAR VILLAGE DR. IS GREATER THA
N 272.5 FT.
11. SHOW ANGLES ON THE SANITARY SEWER MANHOLES.
*
12. THERE IS OVERLAPPING TEXT AT STA 13+00 ON PROFILE SHEET
C-15.
13. THE WATER MAIN SHOULD BE SHOWN AT 3.5 FT COVER EXCEPT F
OR THOSE LOCATIONS WHERE THE WATER MAIN MUST BE
LOWERED TO CROSS A STORM PIPE USING RESTRAINED VERTICAL BEND
* IN ACCORDANCE WITH DETAIL WAT-8.
14. THE WATER MAIN DEPTH AT THE INTERSECTION OF POPLAR VILL
*GE DR AND POPLAR VILLAGE PL IS SHOWN DIFFERENTLY ON SHEET C
-15 AND SHEET C-16.
15. CALL OUT MH-3 TO HAVE AN INTERNAL DROP PER MAN-16 AND I
*CLUDE THE DETAIL IN THE PLAN SET.
16. THE LABEL FOR MH-2 ON SHEET C-15 IS DUPLICATED AND IS M
*SSING THE INVERT IN.
17. THE INVERT IN FOR MH-3 ON SHEET C-16 SHOULD BE 133.12.
*
18. IT APPEARS THAT MH-1 COULD BE SIGNIFICANTLY
SHALLOWER AND STILL PROVIDE GRAVITY SERVICE TO LOTS 17-18.
19. IDENTIFY AND LABEL ANY LOTS WHERE THE LIKELY FINISHED F
*OOR OF THE HOUSE IS LOWER THAN THE UPSTREAM MANHOLE RIM ELE
VATION AS REQUIRING A BACKWATER VALVE ON THE SEWER LATERAL.
THIS APPEARS TO APPLY FOR LOTS 19-23 AND 29-32.
20. THE TEXT ON SHEETS C-6 AND C-7 IS TOO SMALL. PER COUNTY
STANDARDS, THE MINIMUM TEXT HEIGHT IS 0.1"; MANY OF THE WOR
DS SCALE AT ABOUT 0.06". I BELIEVE THIS IS THE RESULT OF CH
ANGING THE SCALE OF THESE SHEETS. I KNOW BILL VIER TOLD YOU
TO CHANGE IT TO 1"=50' BUT
RATHER THAN RE-DRAFTING ALL THE TEXT FOR THIS SMALL SUBDIVIS
*ON YOU MAY PUT THE SCALE BACK TO 1" = 30'.
21. SHOW THE BENCHMARK ON THE UTILITY SHEETS.
*
22. INCLUDE A MISS UTILITY NOTE ON THE COVER SHEET.
*
23. ADJUST THE WATER SERVICES FOR LOTS 5, 6, 28, AND 29 SO
THAT THEY ARE SHOWN PERPENDICULAR TO THE MAIN. THE LOCATION
OF THE SERVICE FOR LOT 29 MAY NEED TO BE MOVED TO AVOID A CO
NFLICT WITH THE STORM DROP INLET.
.
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: POPLAR VILLAGE
CASE NUMBER: 16CP0045
LATEST PLAN DATE: 12/04/15
DEPT. REC'D. DATE: 12/11/15
SUBMITTAL NUMBER: ONE
REVIEW DATE: 01/06/16
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
1. THE TRANSPORTATION DEPARTMENT'S FILE ON POPLAR VILLAGE'S
2005 TENTATIVE PLAN APPROVAL CONTAINS A STATEMENT THAT
SOUTH CHESTER ROAD WOULD HAVE TO BE LOWERED TO MEET MINIMUM
SIGHT DISTANCE REQUIREMENTS. THIS MAY HAVE BEEN ADDRESSED
ON THESE CONSTRUCTION PLANS BY MOVING THE INTERSECTION OF
POPLAR VILLAGE DRIVE WITH SOUTH CHESTER ROAD FURTHER NORTH.
PLEASE STAKE THE CENTERLINE LOCATION OF PROPOSED POPLAR
VILLAGE DRIVE AT SOUTH CHESTER ROAD SO SIGHT DISTANCE CAN
BE FIELD-VERIFIED.
2. PLEASE CORRECT THE LABEL ON SOUTH CHESTER ROAD TO
INDICATE THE CURRENT SPEED LIMIT OF 35 MILES PER HOUR.
3. PLEASE ADD THE ULTIMATE RIGHT OF WAY WIDTH OF 70 FEET
AND THE EXISTING AVERAGE DAILY TRAFFIC VOLUME OF 2,850
VEHICLES PER DAY TO THE LABEL ON SOUTH CHESTER ROAD.
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: POPLAR VILLAGE
CASE NUMBER: 16CP0045
LATEST PLAN DATE: 03/22/2017
DEPT. REC'D. DATE: 04/14/2017
SUBMITTAL NUMBER: TWO
REVIEW DATE: 05/02/2017
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
.
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE: JEFF DOPP/717-6191
EMAIL: DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN: POPLAR VILLAGE
PLAN NUMBER-------16CP0045
ORIGINAL PLAN DATE: 10/07/2015
REVIEW DATE: 01/05/2016
DEPT. REC'D. DATE: 12/07/15
ACCEPTED FOR REVIEW: 12/10/2015
SUBMITTAL NUMBER: ONE
STATUS: CORRECTIONS REQUIRED
TABLE REVIEW: NO
CORRECTIONS REQUIRED:
01. ADD THE COUNTY PROJECT NUMBER 16CP0045 IN THE LOWER
RIGHT CORNER OF EACH PAGE.
02. PROVIDE A REVISION DATE ON ALL REVISED SHEETS.
03. THE BOUNDARIES OF THE PROPOSED CONSTRUCTION PLANS
ENCROACH INTO PARCEL IDENTIFIED IN COUNTY
RECORDS AS TAX ID NUMBER 791-651-0197 OWNED BY
JOSEPH H. SNEAD ESTATE. THIS PARCEL WAS NOT SHOWN ON
THE TENTATIVE PLAT (05TS0151) NOR IS IT IDENTIFIED OR
SHOWN ON THE CONSTRUCTION PLAN APPLICATION OR
CONSTRUCTION PLANS CURRENTLY UNDER REVIEW. REVIEWER
HAS CONTACTED JOE DUTY WITH CHESTERFIELD COUNTY
RIGHT-OF-WAY DEPARTMENT FOR CLARIFICATION REGARDING
THIS PARCEL AND ACCORDING TO UTILITIES, THE UTILITIES
DEPARTMENT DID A WATERLINE REHAB FROM CURTIS TO
HAPPY HILL ALONG SOUTH CHESTER RD. THE PROJECT
ENGINEER SURVEYED THE ENTIRE ROAD FRONTAGE AND IDENTIFIED
THAT THERE WAS AN APPROXIMATE 40' GAP IN THE DEEDS/SURVEYS.
FURTHER RESEARCH REVEALED AN OLD WILL THAT CREATED THE 40'
AND THE ADJACENT PARCELS. ONE PARCEL WAS CONVEYED TO THE
EAST LINE OF WEST RD EXTENDED AND THE OTHER TO THE WEST
LINE OF WEST RD EXTENDED THUS CREATING THIS PARCEL.
FOR YOUR REFERENCE, REVIEWER HAS INCLUDED A COPY OF THE
CERTIFICATE AND UTILITIES CORRESPONDENCE. THIS MAY HAVE
A SUBSTANTIAL IMPACT ON THE TENTATIVE LAYOUT, PROPOSED
LOT SIZES, CONFIGURATION, AND NUMBER OF LOTS. PRIOR TO
RESUBMITTING PLANS PLEASE RESOLVE THIS MATTER AND
COMMUNICATE WITH REVIEWER HOW THIS ISSUE IS WILL BE
RESOLVED. WE WILL FURTHER DISCUSS AT STAFF/DEVELOPER
MEETING.
04.SHEET C-2: THE DIMENSION OF THE SUBDIVISION BOUNDARY LINE
SHOWN ON LOT 16 ADJACENT TO TAX I.D 790-652- 0379 IS LABELED
AS 208.30'. WHEN YOU SCALE THIS PROPERTY LINE THE DIMENSION
IS APPROXIMATELY 233'. PLEASE REVISE PLAT TO SHOW
CORRECT DIMENSION.
05. SHEET C-2: THE REAR PROPERTY LINES FOR LOTS 16 AND 17 DO
NOT MATCH THE PROPERTY LINES AS SHOWN IN THE COUNTY
GIS SYSTEM AND THE APPROVED TENTATIVE PLAT. ALSO THE
CONSTRUCTION PLAN SHOWS THE REAR PROPERTY LINES
FOR THESE TWO LOTS HAVE GHOST LINES. DARKEN THE REAR
PROPERTY LINES FOR LOTS 16 AND 17 AND LABEL PROPERTY
LINE DIMENSIONS.
06. SHEET C-2: REVISE PLANS SHOWING GHOST LINES FOR THE
ADJACENT PROPERTY LINES FOR TAX ID NUMBER 791-652-2167
AND 791-652-2850.
07. WILL THERE BE ANY RETAINING WALL'S WITHIN THE BOUNDARIES
OF THE SUBDIVISION? ON THE COVER SHEET, PLEASE PROVIDE
A NOTE THAT STATES RETAINING WALLS ARE/ARE NOT PRESENT
WITHIN THE BOUNDARIES OF THIS CONSTRUCTION PLAN. IF
RETAINING WALLS ARE PRESENT, PLEASE PROVIDE A
CROSS-SECTION OF THE RETAINING WALL AND PROVIDE THE
MAXIMUM HEIGHT OF THE RETAINING WALL. RETAINING
WALLS MUST ALSO BE DEPICTED IN LABELED ON ALL ROAD PLAN
SHEETS.
08. SHEET C-1: UNDER "SITE SUMMARY AND NOTES", NOTE
#4 INCORRECTLY IDENTIFIES THE ADDRESSES OF THE
SUBJECT PARCELS. REVISE TO SHOW CORRECT ADDRESSES.
09. SHEETS C-1 7 C-2: THE LOCATION/VICINITY SKETCH PROVIDED
IS 1" TO 2,000' SCALE. PLANS REQUIRE 1" TO 1,000' SCALE.
PLEASE REVISE ON BOTH SHEETS.
10. SHEET C-9: THE EROSION CONTROL PLAN SHOWS A SLIGHT
ENCROACHMENT OF THE PROPOSED SOIL STOCKPILE INTO
THE 50' BUFFER. PLEASE REVISE PLANS REMOVING FROM
LIMITS OF 50' BUFFER.
11. SHOW AND LABEL DIMENSIONS FOR EACH LOT.
SOME OF THE LOTS APPEAR TO BE LESS THAN 75' FEET IN WIDTH
12. SHEET C-1:ON THE COVER SHEET LABEL THE ACREAGE FOR LOTS
AND RIGHT-OF-WAYS IN SUBDIVISION, ALSO, LABEL THE MINIMUM,
MAXIMUM AND AVERAGE LOT SIZE.
13. SHEET C-2 CLEARLY LABEL AND SHOW LOT DIMENSIONS AND
SUBDIVISION BOUNDARY DIMENSIONS. DIMENSIONS
SHOWN ALONG NORTHERN SUBDIVISION BOUNDARY
DO NOT SCALE.
14. ON ALL PLAN SHEETS, LABEL THE FRONT BUILDING LINE "B/L"
ALL LOTS THAT HAVE FRONT BUILDING LINES.
15. SHEET C-2 SHOWS A SYMBOL ADJACENT TO LOTS 33 AND
17 HOWEVER, THIS SYMBOL IS NOT IDENTIFIED ON THE
LEGEND OR SHOWN ON SHEETS C-3 AND C-4. PLEASE
IDENTIFY AND KEY TO LEGEND AND ADD TO SHEETS
C-3 AND C-4.
16. ON PLANS INCLUDE A MANUFACTURERS CUT SHEET FOR
ANY PROPOSED STREET LIGHT POLES AND FIXTURES.
17. LOTS 22, 23, 24 & 25: PORTIONS OF THE BUILDING
ENVELOPES SHOWN ENCROACH INTO THE PORTION
OF THE LOT WHERE THE LOT WIDTH IS LESS THAN 75'
FEET. REVISE AND SHOW STRAIGHT FRONT BUILDING
LINES RATHER THAN CURVED WHERE AT MINIMUM 75'
OF LOT WIDTH IS ACHIEVED AND ENSURE FRONT BUILDING
LINES ARE UNIFORM AROUND THE BULB OF THE CUL-DE-SAC.
18. LOT 28 BUILDING ENVELOPE SHOWS A 25' SIDE YARD
SETBACK. PLEASE REVISE BUILDING ENVELOPE AND
DIMENSION TO SHOW A 7.5' FOOT SIDE YARD SETBACK.
19. DIMENSION AND LABEL A 25' REAR YARD SETBACK
FOR LOTS 25, 26 & 27.
20. THE LOT WIDTH FOR LOTS 3, 4, 31 & 32 APPEAR TO BE
LESS THAN 75' IN WIDTH PLEASE PROVIDE LOT
DIMENSIONS.
21. LOT 33: THE FRONT BUILDING ENVELOPE SHOWN ENCROACHES
INTO THE PORTION OF THE LOT THAT DOES NOT ACHIEVE
A REQUIRED MINIMUM LOT WIDTH OF 75' FEET. PLEASE REVISE
AND MOVE BUILDING ENVELOPE FURTHER BACK WHERE THE
75' LOT WIDTH IS ACHIEVED.
22. IN THE EROSION CONTROL NARRATIVE, PLEASE SPECIFICALLY
PLACE A PROVISION FOR TREE PROTECTION TAPE AROUND
REQUIRED BUFFERS IN THE NARRATIVE AND ON THE PLAN.
THE NOTE SHOULD READ: "TREE PROTECTION TAPE IS TO
BE INSTALLED TO PROTECT REQUIRED BUFFERS. ANY CLEARING
DISTURBANCE OF THE BUFFERS WILL RESULT IN THE
REPLACEMENT OF VEGETATION AND SUBMITTAL OF A
LANDSCAPE PLAN AND BOND".
NOTES:
A. ANY CHANGE IN THE CURRENT PLAN, WHETHER IT STEMS FROM
DEPARTMENT COMMENTS OR AN ENGINEERING CHANGE REQUESTED
BY THE APPLICANT, MAY GENERATE ADDITIONAL COMMENTS FROM
THE REVIEWING DEPARTMENTS, RESULTING IN REQUIRED REVISIONS.
B.ANY BULK REQUIREMENTS(LOT AREA,LOT WIDTH,SETBACKS,BUILDING
ENVELOPES, ETC.) SHOWN ON THE APPROVED CONSTRUCTION PLANS
WILL BE SUBJECT TO REVIEW FOR COMPLIANCE AT TIME OF FINAL
CHECK.
C. IN CONJUNCTION WITH THE SUBMITTAL OF THE FINAL CHECK
PLATS, THE SUBDIVIDER SHALL FLAG ALL BUFFERS FOR
INSPECTION BY THE PLANNING DEPARTMENT. IF INSUFFICIENT
LANDSCAPE PLAN TO THE DIRECTOR OF PLANNING TO ENSURE
COMPLIANCE WITH THE CONDITION. IF CONDITIONS ON SITE
ARE NOT CONDUCIVE TO PLANT SURVIVAL, THE SUBDIVIDER
SHALL PROVIDE SURETY TO THE COUNTY IN THE AMOUNT
REQUIRED TO IMPLEMENT THE PLAN. AN ESTIMATE FROM A
LANDSCAPE CONTRACTOR SHALL SERVE AS THE BASIS FOR THE
SURETY AMOUNT.
D.IN THE EROSION CONTROL NARRATIVE,PLEASE SPECIFICALLY PLACE
PROVISION FOR TREE PROTECTION TAPE AROUND REQUIRED BUFFERS
IN THE NARRATIVE AND ON THE PLAN. THE NOTE SHOULD READ:
"TREE PROTECTION TAPE IS TO BE INSTALLED TO PROTECT REQUIRED
BUFFERS.ANY CLEARING OR DISTURBANCE OF THE BUFFERS WILL
RESULT IN THE REPLACEMENT OF VEGETATION AND SUBMITTAL OF A
LANDSCAPE PLAN AND BOND".
E. A NOTE SHALL BE PLACED ON THE FINAL PLAT THAT
INDICATES THE BUFFERS ARE EXCLUSIVE OF
EASEMENTS, CUT AND FILL SLOPES AND SETBACKS. THE
BUFFERS ARE TO REMAIN UNDISTURBED AND NO ACCESS
IS PERMITTED THROUGH THEM TO ANY ADJACENT ROADS.(P)
F. STANDARD CONDITIONS PER 17-62 OF THE SUBDIVISION
ORDINANCE. (P)
G. BUILDING ENVELOPES SHALL BE SHOWN ON ALL
BUILDING LOTS THAT ARE IMPACTED BY WETLANDS OR MINING
ACTIVITIES. DIMENSIONED FRONT BUILDING LINES SHALL BE
SHOWN ON ALL LOTS THAT DO NOT ACHIEVE THE REQUIRED LOT
WIDTH AT THE MINIMUM SETBACK DISTANCE. (P)
H. ANY CHANGE IN WHETHER IT STEMS FROM
DEPARTMENT COMMENTS OR AN
ENGINEERING CHANGE REQUESTED BY
THE APPLICANT, MAY GENERATE
ADDITIONAL COMMENTS FROM THE
REVIEWING DEPARTMENTS, RESULTING IN
REQUIRED REVISIONS.
I. ANY BULK REQUIREMENTS (LOT AREA, LOT
WIDTH, SETBACKS, BUILDING ENVELOPES,
ETC.) SHOWN ON THE APPROVED
CONSTRUCTION PLANS WILL BE SUBJECT
TO REVIEW FOR COMPLIANCE AT TIME OF
FINAL CHECK.
J. VERIFY WIDTH OF ALL LOTS AND ENSURE AND ADJUST
BUILDING LINE TO ACHIEVE WIDTH AND ENSURE CORRECT
DIMENSIONS ARE SHOWN ON FINAL AND RECORD PLAT.
K. SETBACKS AROUND CUL DE SAC SHALL BE UNIFORM.
L. STANDARD CONDITIONS
M. BUFFER ALONG SOUTH CHESTER ROAD SHALL COMPLY WITH SECTION
17-70.
N. IF THE DEVELOPER ELECTS TO CREATE AN UPLAND BUFFER TO
MINIMIZE MITIGATION COSTS,THE TWENTY-FIV (25) BUFFER SHALL
BE MEASURED FROM THE OUTERMOST LIMITS OF BUFFER.
O. ALL LOTS THAT ARE IMPACTED BY WETLANDS SHALL SHOW A
DIMENSIONED BUILDING ENVELOPE ON THE FINAL CHECK AND
RECORD PLAT.
P. IN A LOT SUBDIVISION, A HOMEOWNERS' ASSOCIATION
SHALL BE REQUIRED WHEN THERE IS TO
BE COMMONLY HELD PROPERTY INCLUDING, BUT NOT
IMITED TO, EASEMENTS, PRIVATE PAVEMENT, OPEN
SPACE OR PRIVATE UTILITIES PER SEC. 19.1-303.
############################################################
############################################################
#
REVIEWER / PHONE: JEFF DOPP/717-6191
EMAIL: DOPPJ@CHESTERFIELD.GOV
NAME OF PLAN: POPLAR VILLAGE
PLAN NUMBER-------16CP0045
SUBMITTAL NUMBER: TWO
ORIGINAL PLAN DATE: 10/07/2015
REVISED PLAN DATE: 3/22/2017
REVIEW DATE: 5/10/2017
DEPT. REC'D. DATE: 04/11/2017
ACCEPTED FOR REVIEW: 04/12/2017
STATUS: CORRECTIONS REQUIRED
TABLE REVIEW: NO
01. ALL SHEETS SHOW A REVISION DATE OF 8/3/16. A
SUBMITTAL FOR THIS REVISION DATE WAS NEVER
SUBMITTED FOR COUNTY REVIEW. PLEASE
REMOVE THIS REVISION DATE FROM ALL SHEETS.
.
02. PROVIDE A REVISION DATE ON ALL REVISED SHEETS.
.
03. PREVIOUS REVIEW COMMENT 3 HAS NOT BEEN RESOLVED.
THE BOUNDARIES OF THE PROPOSED CONSTRUCTION PLANS
ENCROACH INTO PARCEL IDENTIFIED IN COUNTY
RECORDS AS TAX ID NUMBER 791-651-0197 OWNED BY
JOSEPH H. SNEAD ESTATE. THIS PARCEL WAS NOT SHOWN ON
THE TENTATIVE PLAT (05TS0151) NOR IS IT IDENTIFIED OR
SHOWN ON THE CONSTRUCTION PLAN APPLICATION OR
CONSTRUCTION PLANS CURRENTLY UNDER REVIEW. REVIEWER
HAS CONTACTED JOE DUTY WITH CHESTERFIELD COUNTY
RIGHT-OF-WAY DEPARTMENT FOR CLARIFICATION REGARDING
THIS PARCEL AND ACCORDING TO UTILITIES, THE UTILITIES
DEPARTMENT DID A WATERLINE REHAB FROM CURTIS TO
HAPPY HILL ALONG SOUTH CHESTER RD. THE PROJECT
ENGINEER SURVEYED THE ENTIRE ROAD FRONTAGE AND IDENTIFIED
THAT THERE WAS AN APPROXIMATE 40' GAP IN THE DEEDS/SURVEYS.
FURTHER RESEARCH REVEALED AN OLD WILL THAT CREATED THE 40'
AND THE ADJACENT PARCELS. ONE PARCEL WAS CONVEYED TO THE
EAST LINE OF WEST RD EXTENDED AND THE OTHER TO THE WEST
LINE OF WEST RD EXTENDED THUS CREATING THIS PARCEL.
FOR YOUR REFERENCE, REVIEWER HAS INCLUDED A COPY OF THE
CERTIFICATE AND UTILITIES CORRESPONDENCE. THIS MAY HAVE
A SUBSTANTIAL IMPACT ON THE TENTATIVE LAYOUT, PROPOSED
LOT SIZES, CONFIGURATION, AND NUMBER OF LOTS. PRIOR TO
RESUBMITTING PLANS PLEASE RESOLVE THIS MATTER AND
COMMUNICATE WITH REVIEWER HOW THIS ISSUE IS WILL BE
RESOLVED. WE WILL FURTHER DISCUSS AT STAFF/DEVELOPER
MEETING.
.
04. THE ADJACENT PROPERTY OWNED BY GREG D. & THELMA I.
SMITH SHOWS THE INCORRECT ADDRESS AND TAX I.D NUMBER.
COUNTY RECORDS SHOW THE ADDRESS IS 12500 PERCIVAL
STREET AND THE TAX I.D NUMBER IS 791-652-4738.
PLEASE REVISE ON ALL SHEETS.
.
05. THE ADJACENT PROPERTY LABELED AS "WEST STREET (VACATED)"
IS A PARCEL. PLEASE REVISE TO SHOW OWNERSHIP INFORMATION,
ADDRESS, TAX I.D NUMBER AND DEED BOOK AND PAGE NUMBER.
COUNTY RECORDS SHOW PROPERTY OWNED BY GREG D. &
THELMA I. SMITH. ADDRESS IS 12450 PERCIVAL STREET.
TAX I.D NUMBER IS 791-652-4044. DEED BOOK IS 7700
PAGE 470. PLEASE REVISE ON ALL SHEETS.
.
06. DARKEN THE REAR PROPERTY LINES FOR LOTS 16 AND 17.
.
07.DIMENSION LOT 3 TO SHOW A 75'LOT WIDTH AT THE 30'
SETBACK. REVIEWER IS SCALING AT 74' FEET.
.
08. PER PREVIOUS REVIEW COMMENT: ON PLANS INCLUDE
A MANUFACTURERS CUT SHEET FOR ANY PROPOSED STREET
LIGHT POLES AND FIXTURES.
.
09. PER PREVIOUS COMMENT 20, THE LOT WIDTH FOR LOTS
3, 4, 31 & 32 APPEAR TO BE LESS THAN 75' IN WIDTH.
PLEASE LABEL AND SHOW LOT DIMENSIONS. RESPONSE
TO PREVIOUS COMMENT #20 STATES DIMENSIONS
WERE ADDED. HOWEVER, LOT DIMENSIONS WERE NOT
SHOWN ON RESUBMITTAL.
.
NOTES:
.
A. ANY CHANGE IN THE CURRENT PLAN, WHETHER IT STEMS FROM
DEPARTMENT COMMENTS OR AN ENGINEERING CHANGE REQUESTED
BY THE APPLICANT, MAY GENERATE ADDITIONAL COMMENTS FROM
THE REVIEWING DEPARTMENTS, RESULTING IN REQUIRED REVISIONS.
.
B. ANY BULK REQUIREMENTS (LOT AREA, LOT WIDTH, SETBACKS,
BUILDING ENVELOPES, ETC.) SHOWN ON THE APPROVED
CONSTRUCTION PLANS WILL BE SUBJECT TO REVIEW FOR
COMPLIANCE AT TIME OF FINAL CHECK.
.
C. IN CONJUNCTION WITH THE SUBMITTAL OF THE FINAL CHECK
PLATS, THE SUBDIVIDER SHALL FLAG ALL BUFFERS FOR
INSPECTION BY THE PLANNING DEPARTMENT. IF INSUFFICIENT
VEGETATION REMAINS, THE SUBDIVIDER SHALL SUBMIT A
LANDSCAPE PLAN TO THE DIRECTOR OF PLANNING TO ENSURE
COMPLIANCE WITH THE CONDITION. IF CONDITIONS ON SITE
ARE NOT CONDUCIVE TO PLANT SURVIVAL, THE SUBDIVIDER
SHALL PROVIDE SURETY TO THE COUNTY IN THE AMOUNT
REQUIRED TO IMPLEMENT THE PLAN. AN ESTIMATE FROM A
LANDSCAPE CONTRACTOR SHALL SERVE AS THE BASIS FOR THE
SURETY AMOUNT.
.
D. IN THE EROSION CONTROL NARRATIVE, PLEASE SPECIFICALLY
PLACE A PROVISION FOR TREE PROTECTION TAPE AROUND
REQUIRED BUFFERS IN THE NARRATIVE AND ON THE PLAN.
THE NOTE SHOULD READ: "TREE PROTECTION TAPE IS TO
BE INSTALLED TO PROTECT REQUIRED BUFFERS. ANY CLEARING
OR DISTURBANCE OF THE BUFFERS WILL RESULT IN
REPLACEMENT OF VEGETATION AND SUBMITTAL OF A
LANDSCAPE PLAN AND BOND".
.
E. A NOTE SHALL BE PLACED ON THE FINAL PLAT THAT
INDICATES THE BUFFERS ARE EXCLUSIVE OF
EASEMENTS, CUT AND FILL SLOPES AND SETBACKS. THE
BUFFERS ARE TO REMAIN UNDISTURBED AND NO ACCESS
IS PERMITTED THROUGH THEM TO ANY ADJACENT ROADS.
(P)
.
F. STANDARD CONDITIONS PER 17-62 OF THE SUBDIVISION
ORDINANCE. (P)
.
G. BUILDING ENVELOPES SHALL BE SHOWN ON ALL
BUILDING LOTS THAT ARE IMPACTED BY WETLANDS OR MINING
ACTIVITIES. DIMENSIONED FRONT BUILDING LINES SHALL BE
SHOWN ON ALL LOTS THAT DO NOT ACHIEVE THE REQUIRED LOT
WIDTH AT THE MINIMUM SETBACK DISTANCE. (P)
.
H. ANY CHANGE IN WHETHER IT STEMS FROM
DEPARTMENT COMMENTS OR AN
ENGINEERING CHANGE REQUESTED BY
THE APPLICANT, MAY GENERATE
ADDITIONAL COMMENTS FROM THE
REVIEWING DEPARTMENTS, RESULTING IN
REQUIRED REVISIONS.
.
I. ANY BULK REQUIREMENTS (LOT AREA, LOT
WIDTH, SETBACKS, BUILDING ENVELOPES,
ETC.) SHOWN ON THE APPROVED
CONSTRUCTION PLANS WILL BE SUBJECT
TO REVIEW FOR COMPLIANCE AT TIME OF
FINAL CHECK.
.
J. VERIFY WIDTH OF ALL LOTS AND ENSURE AND ADJUST
BUILDING LINE TO ACHIEVE WIDTH AND ENSURE CORRECT
DIMENSIONS ARE SHOWN ON FINAL AND RECORD PLAT.
.
K. SETBACKS AROUND CUL -DE- SAC SHALL BE UNIFORM
.
L. STANDARD CONDITIONS
.
M. BUFFER ALONG SOUTH CHESTER ROAD SHALL COMPLY
WITH SECTION 17-70. BUFFER IS EXCLUSIVE OF EASEMENTS
AND SETBACKS. BUFFER MUST REMAIN IN A NATURAL STATE.
BUFFER WILL BE FIELD REVIEWED AT TIME OF FINAL CHECK.
ANY CLEARING OR REMOVAL OF VEGETATION FROM BUFFER
WILL RESULT IN LANDSCAPE PLAN SUBMITTAL AND
BOND AT FINAL CHECK.
.
N. IF THE DEVELOPER ELECTS TO CREATE AN UPLAND BUFFER
TO MINIMIZE MITIGATION COSTS, THE TWENTY-FIVE (25)
BUFFER SHALL BE MEASURED FROM THE OUTERMOST
LIMITS OF BUFFER.
.
O. ALL LOTS THAT ARE IMPACTED BY WETLANDS SHALL SHOW A
DIMENSIONED BUILDING ENVELOPE ON THE FINAL CHECK AND
RECORD PLAT.
.
P. IN A LOT SUBDIVISION, A HOMEOWNERS' ASSOCIATION
SHALL BE REQUIRED WHEN THERE IS TO
BE COMMONLY HELD PROPERTY INCLUDING, BUT NOT
LIMITED TO, EASEMENTS, PRIVATE PAVEMENT, OPEN
SPACE OR PRIVATE UTILITIES PER SEC. 19.1-303.
###############################################
REVIEW DEPARTMENT: FIRE AND LIFE SAFETY
REVIEWER / PHONE#: KIM LESTER / 748-1489
PLAN NAME: POPULAR VILLAGE
PLAN NUMBER: 16CP0045
LATEST REVISION DATE: 10/7/15
REVIEW DATE: 11/17/15
LATEST SUBMISSION DATE: 12/14/15
SUBMITTAL NUMBER: 1ST REVIEW
STATUS: NOT APPROVED
TABLE REVIEW:
RELOCATE THE HYDRANT ON POPULAR VILLAGE PLACE TO
THE INTERSECTION OF POPULAR VILLAGE PLACE AND POPULAR
VILLAGE DRIVE.
ADD A HYDRANT AT THE INTERSECTION OF POPULAR VILLAGE DRIVE
AND SOUTH CHESTER ROAD.
PROVIDE A COMPUTER GENERATED WATER FLOW TEST DATA,
ALONG WITH THE NODE MAP THAT IS PROVIDED BY THE
CHESTERFIELD COUNTY UTILITIES DEPARTMENT, VERIFYING
THE REQUIRED WATER FLOW FOR FIRE PROTECTION IS AVAILABLE
AT THE SITE THE WATER FLOW TEST RESULTS AND GRAPH SHALL
BE SHOWN ON THE SUBMITTED PLAN. IFC 2012, SECTION B105.1
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT: FIRE AND LIFE SAFETY
REVIEWER / PHONE#: KIM LESTER / 748-1489
PLAN NAME: POPULAR VILLAGE
PLAN NUMBER: 16CP0045
LATEST REVISION DATE: 3/22/17
REVIEW DATE: 4/18/17
LATEST SUBMISSION DATE: 4/17/17
SUBMITTAL NUMBER: 2ND REVIEW
STATUS: APPROVED
TABLE REVIEW: YES
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++
============================================================
============================================================
.
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE #: CHRIS SOLDAN (AGENT REVIEWER)/665-1095
NAME OF PLAN: POPLAR VILLAGE
SITE PLAN NO.: 16CP0045
LATEST PLAN DATE: 03/22/2017
DEPT. REC'D DATE: 03/13/2017
SUBMITTAL NUMBER: 2
REVIEW DATE: 05/03/2017
RECOMMENDATION: REVISION REQUIRED
TABLE REVIEW: NO
.
-------- GENERAL NOTES --------
.
001. IT IS THE RESPONSIBILITY OF THE APPLICANT TO COMPLY
WITH AND/OR ACQUIRE ALL APPLICABLE FEDERAL AND/OR STATE
PERMITS IN RELATION TO ENVIRONMENTAL FEATURES
INCLUDING, BUT NOT LIMITED TO, WETLANDS, SURFACE WATER,
GROUND WATER, AND AIR QUALITY. FINAL APPROVAL OF THESE
PLANS WILL NOT RELIEVE YOU OF YOUR RESPONSIBILITIES.
.
002. AS A PREREQUISITE TO THE PLAN APPROVAL, A COPY OF THE
WETLANDS CONFIRMATION FROM THE USACOE MUST BE RECEIVED.
.
003. AS A PREREQUISITE TO THE ISSUANCE OF A LAND DISTURBANCE
PERMIT:
.
A) A COPY OF THE AUTOCAD FILE MUST BE SUBMITTED TO
CAROLE CLIBORNE OF ENVIRONMENTAL ENGINEERING. THE
AUTOCAD FILE MUST BE SAVED AS A .DWG OR .DXF IN
AUTOCAD VERSION 2009 OR EARLIER AND REFERENCED
DIRECTLY TO THE VIRGINIA STATE PLANE COORDINATE
SYSTEM, SOUTH ZONE IN THE NAD83 DATUM. THE AUTOCAD
FILE MAY BE SUBMITTED ON A CD, DVD, OR VIA EMAIL AND
MUST BE CLEARLY LABELED WITH THE SUBDIVISION NAME
AND SECTION, SUBDIVISION PLAN NUMBER, ENGINEERING
FIRM AND CAD FILE PREPARER'S NAME AND PHONE NUMBER.
THE FILE MUST CONTAIN THE FOLLOWING, EACH CLEARLY
LABELED IN SEPARATE LAYERS:
.
1. EDGES OF ROADS TO INCLUDE CURB AND GUTTER; AND
.
2. EDGES OF SIDEWALKS.
.
THE FILE MUST BE APPROVED BY ENVIRONMENTAL
ENGINEERING PRIOR TO ISSUANCE OF THE LAND
DISTURBANCE PERMIT.
.
B) FLAGGING AROUND USACOE JURISDICTIONAL WETLANDS,
BUFFERS, AND SENSITIVE AREAS MUST BE VISIBLE.
.
C) A VSMP REGISTRATION AND FEE FORM MUST BE PROCESSED
AND/OR RECEIVED.
.
D) THE LIMITS OF THE WETLANDS MUST BE FLAGGED IN THE
FIELD WITH OPTIC ORANGE SAFETY FENCE AND WETLANDS
PROTECTION TAPE PRIOR TO ISSUANCE OF A LAND
DISTURBANCE PERMIT.
.
E) A COPY OF THE WETLANDS PERMIT FROM USACOE/DEQ MUST
BE RECEIVED, IF APPLICABLE.
.
F) A COPY OF VDOT LAND USE PERMIT MUST BE RECEIVED.
.
G) AN EROSION CONTROL BOND MUST BE POSTED IN AN AMOUNT
APPROVED BY THE DEPARTMENT.
.
H) TWO ADDITIONAL SETS OF CONSTRUCTION PLANS TO BE
STAMPED "APPROVED FOR CONSTRUCTION" MUST BE
RECEIVED.
.
I) THE ENVIRONMENTAL ENGINEERING DEPARTMENT MUST HAVE
RECEIVED SIGNED, WRITTEN NOTIFICATIONS FROM THE
ADJACENT PROPERTY OWNERS, N/F DEAN, N/F BROOME, N/F
BENTON, N/F GREGORY, N/F MINES, N/F PACKET, AND N/F
NEW HYDE PARK ASSOCIATION LLC WHICH SHOULD BE
SENT U.S. POSTAL CERTIFIED MAIL, RETURN RECEIPT
REQUESTED. INCLUDE AN 8½ X11 COPY OF THE PROPOSED
CONSTRUCTION ACTIVITY ADJACENT TO THEIR PROPERTIES.
.
004. COVER SHEET: INCLUDE THE VSMP PERMIT NUMBERS FOR THE
TWO PREVIOUS PERMIT CYCLES (2009-2014) & (2014-PRESENT)
IN THE VSMP PART IIC COMPLIANCE NOTE.
.
-------- ROAD AND DRAINAGE --------
.
005. SHEET C3: PLEASE SHOW THE PROPOSED GRADE OVER THE
CULVERT. IT APPEARS THERE WILL BE LESS THAN 1' OF COVER
PROVIDED. VDOT MAY WISH TO COMMENT ON THIS ISSUE.
.
006. SHEET C3: IT APPEARS THE WATERLINE AT STA 106+00 WILL
CONFLICT WITH EITHER THE CULVERT OR DITCH INVERT.
PLEASE ADDRESS.
.
007. SHEET C3: PLEASE SHOW AND LABEL THE PROPOSED DITCH
CENTERLINE, DITCH SLOPE, AND EXISTING ROAD GRADE LEFT
ALONG THE DITCH CENTERLINE. WHERE THE DITCH TURNS TO
THE EAST DOWN THE PROPERTY LINE, REFERENCE THE
CONTINUATION OF THE DITCH PROFILE ON STORM OUTFALL C ON
C18.
.
008: SHEET C5: THE NBP CALLOUT IS MISSING FROM LOT 16 (IT
DOES APPEAR ON C9).
.
009: SHEET C8-C9: BASED ON THE UPDATED EXISTING GRADING
CONTOURS, FILL IS NECESSARY ON MULTIPLE LOTS TO
ELIMINATE AREAS OF STORMWATER RUNOFF CONCENTRATION
(TENTATIVE CONDITION 4):
.
A. LOTS 6/7: GRADE AND FILL TO ELIMINATE THE LOW.
PROVIDE A SIDEYARD SWALE ON LOT 7 TO DIRECT FLOW TO
THE DITCH IN THE REAR.
.
B. LOTS 12/13/14: GRADE AND FILL TO ELIMINATE THE LOW.
PROVIDE A DITCH IN THE DRAINAGE EASEMENT BEHIND LOTS
13/14 TO DIRECT FLOW INTO STR41
.
C. LOTS 19/20/21: GRADE AND FILL TO ELIMINATE THE LOW.
TIE THE PROPOSED GRADING INTO THE DITCH GRADING.
.
D. CALLOUT NBP FOR LOTS 6,12,13,&14 ON SHEETS
C4,C5,C8,&C9.
.
010: SHEET C8-C9: SHOW THE PROPOSED GRADING FOR ALL 3:1
DITCHES TO ENSURE THEY CAN BE INCORPORATED INTO THE
GRADING PLAN AND STAY WITHIN THE PROJECT LIMITS.
.
011: SHEETS C8: SHOW THE PROPOSED GRADING WITHIN THE VDOT
R/W AT THE SITE ENTRANCE TO TIE POPLAR VILLAGE DRIVE
INTO SOUTH CHESTER ROAD.
.
012: SHEETS C8: AS PREVIOUSLY REQUESTED PROVIDE A SIDE YARD
SWALE ON LOT 3 FROM THE HIGH POINT DISCHARGING TO THE
DITCH. PROVIDE DIMENSION 5' OFF THE PROPERTY LINE
ON THE UPSTREAM SIDE OF DOWNSTREAM LOT. CALLOUT NBP FOR
THIS LOT ON SHEETS C4 AND C8.
.
013: SHEET C9: PLEASE CLARIFY IF THE NOTE ON LOT 19 FOR
"GRADE AT 3:1 UNTIL 3' DEPTH IS ACHIEVED." APPLIES TO
ALL DITCHES ON THE PROJECT OR JUST THE GRADING IN THE
AREA OF OUTFALL G AND LOT 19.
.
014: SHEET C9: THE PROPOSED CONTOURS AROUND THE POPLAR
VILLAGE DRIVE CUL-DE-SAC DO NOT APPEAR TO TIE INTO
EXISTING GRADE. THE GRADING AND DISTURBANCE ALSO
EXTENDS INTO THE RPA. PLEASE ADDRESS.
.
015: SHEET C9: THE DRIVEWAY ENTRANCE ON LOT 9 CONFLICTS WITH
THE CURB INLET STR27. PLEASE ADDRESS.
.
016. SHEET C9: AS PREVIOUSLY REQUESTED AT OUTFALL G, EXTEND
LIMITS OF 100 YR. FLOOD PLAIN TO END OF THE DRAINAGE
EASEMENT OUTFALL. LABEL THE CALCULATED FLOOD ELEVATIONS
AT SECTIONS D-D AND E-E.
.
017: SHEET C9: REVISE LOT 18 MFF(FP)=116.34 (INTERPOLATED
ELEVATION BETWEEN D-D AND E-E) AND PROVIDE LOT 19
MFF(FP)=118.18
.
018: SHEET C14: REVISE DRAINAGE AREAS TO REFLECT THE
SIDEYARD SWALES AT LOT 5 AND LOT 16 AND ANY CHANGES
RESULTING FROM THE GRADING REQUESTED TO FILL LOW AREAS.
.
019: SHEET C14: SHEETS C3 AND C8 INDICATE THE TWO SMALL
DRAINAGE AREAS TO THE SOUTH OF THE SITE ENTRANCE WILL
BE DIRECTED TO THE NORTH THROUGH THE CULVERT. HOWEVER,
THIS SHEET SHOWS A FLOW ARROW POINTING SOUTH. RESPONSE
TO COMMENTS INDICATED FLOW WAS CALCULATED IN SECTION
F-F HOWEVER NO DOCUMENTATION WAS PROVIDED. PLEASE
ADDRESS CONFLICT.
.
020: SHEET C16: STRUCTURES 44, 45, & 46 ARE MISSING FROM THE
DRAINAGE STRUCTURE SUMMARY TABLE. PLEASE ADDRESS.
.
021: SHEET C17: OUTFALL B GRADING - THE INVERT OF THE
PLUNGE POOL LIP APPEARS TO BE SHOWN BELOW THE EXISTING
GRADE AND DOES NOT DAYLIGHT. PLEASE ADDRESS AND
PROVIDE ADDITIONAL DETAIL OF HOW THE PLUNGE POOL
GRADING WILL TIE INTO EXISTING GRADE, PARTICULARLY AT
THE HEADWALL WHICH HAS AN INVERT 8' BELOW SURROUNDING
GRADE.
.
022: SHEET C18: OUTFALL C GRADING - THE TOP OF STR77 SHOULD
NOT BE SHOW BELOW FINISHED GRADE. PLEASE ADDRESS.
.
023: SHEET C18: OUTFALL D GRADING - SHOW THE FINISHED GRADE
WHERE THE DITCH CONNECTS TO STR39.
.
024: SHEET C18: OUTFALL G GRADING - SHOW BOTH THE DITCH
INVERT AND SLOPE AS WELL AS THE PROPOSED FINISH GRADE
SHOWN.
.
-------- EROSION CONTROL --------
.
025. SHEET C10: PLEASE REMOVE THE SIDEYARD SWALES AND DITCH
LABELING FROM PHASE 1.
.
026. THE DIVERSION DIKE ALONG THE NORTHERN PROPERTY LINE
GOES UPHILL ALONG LOTS 8-9. PLEASE ADDRESS.
ADDITIONALLY, ONE CONTINUOUS DIKE ALONG THE FULL
PROPERTY LINE IS NOT ACCEPTABLE AS THE MAXIMUM
ALLOWABLE DRAINAGE AREA IS 5 ACRES PER THE VESCH.
PLEASE ADDRESS. FURTHER DISCUSSION MAY BE HELPFUL.
.
027. SHEET C10: AS PREVIOUSLY REQUESTED SEDIMENT TRAPS #3 &
#5 WILL DISCHARGE INTO TRAP #4. IT ALSO APPEARS THAT
ST#1 WILL DRAIN TO ST#2 THIS IS UNACCEPTABLE EVEN FOR A
SHORT DURING OF PHASE 1. FURTHER DISCUSSION REGARDING
SEDIMENT TRAP ARRANGEMENT MAY BE HELPFUL.
.
028. SHEET C11: AS PREVIOUSLY REQUESTED, ADDITIONAL CONTROL
MEASURES SHOULD BE PROVIDED BELOW THE GRADING FOR
OUTFALL G TO PREVENT SEDIMENT FROM ENTERING THE
WETLANDS. A SEDIMENT TRAP SHOULD BE LOCATED BELOW THE
REQUESTED GRADING FOR LOTS 19/20. FLOW FROM THE
OUTFALL G SHOULD BE TEMPORARY DIRECTED INTO THIS TRAP.
PLEASE ADDRESS.
.
029. SHEET C11: DUE TO THE LONG, NARROW NATURE OF THE SITE
AND THE PROPOSED DITCHES ALONG BOTH NORTH AND SOUTH
PROPERTY LINES, ALL DRAINAGE IS ULTIMATE DIRECTED TO
THE WETLANDS TO THE EAST. THIS MAKES IT VERY DIFFICULT
TO PROVIDE CLEAN WATER DIVERSIONS AND MULTIPLE SEDIMENT
TRAPS WHICH DO NOT DISCHARGE INTO EACH OTHER. CONSIDER
ONE OPTION TO PROVIDE A SINGLE SEDIMENT BASIN NEAR THE
LARGE OUTFALL AND DIRECT ALL FLOWS FROM BOTH ONSITE
AND OFFSITE INTO THIS BASIN UNTIL THE WHOLE SITE IS
STABILIZED. ANOTHER OPTION MAY BE TO INSTALL THE MAIN
SEGMENT OF THE STORM SEWER IN THE FIRST ESC PHASE AND
USE IT AS THE CLEAN WATER DIVERSION AND OUTLET FOR THE
SEDIMENT TRAPS. FURTHER DISCUSSION MAY BE HELPFUL.
.
030. SHEET C11: THE PROPOSED ROAD GRADING CONFLICTS WITH
SEDIMENT TRAPS ST2, ST4, AND ST6. THE PROPOSED STORM
SEWER CONFLICTS WITH ST5. PLEASE ADDRESS.
.
031. SHEET C11: REVISE THE NARRATIVE TO DISCUSS INSTALLATION
OF DROP INLETS (NOTE 8) TO BEFORE THE REMOVAL OF
SEDIMENT TRAPS (NOTE 6).
.
032. SHEET C11: A TEMPORARY SLOPE DRAIN IS STILL NECESSARY
AT TO DIRECT FLOW DOWN THE FILL SLOPES INTO ST#6.
CLARIFY NARRATIVE NOTE #5 TO REQUIRE USE OF TSD DOWN
FILL SLOPES. PLEASE ADDRESS.
.
033. SHEET C11: PLEASE SHOW/LABEL CHECK DAMS ALONG ALL
PROPOSED DITCHES AND SWALES. INCLUDE CHECK DAM DETAIL
ON SHEET C12.
.
034. SHEET C11: AS PREVIOUSLY REQUESTED, LABEL THE MS-19
SECTIONS IN THE TABLE AS MS-19[A], MS-19[B], OR MS-
19#1, MS-19#2, ETC. IN THE DISCHARGE POINT COLUMN,
RATHER THAN THE GENERIC TO EX. WETLANDS. INCLUDE ALL
3 REQUESTED SECTIONS AND UPDATE ALL INFORMATION IN
TABLE AS IT HAS NOTE CHANGED SINCE THE LAST SUBMITTAL.
A FORMAL WRITTEN VARIANCE MUST BE SUBMITTED FOR ANY
SITUATION E SECTION. PLEASE ADDRESS.
.
035. SHEET C11: UPDATE THE FLOW RATES FOR BOTH OP.318 CALCS
TO REFLECT THE MOST RECENT FLOW CALCULATIONS. LABEL
BOTH CALCS ACCORDING TO THE STRUCTURE NUMBER.
.
036. SHEET C12: REVISE LAST GENERAL E&S NOTE TO REQUIRE
STABILIZATION OF AREAS LEFT DORMANT FOR 14 DAYS, NOT 30
DAYS (UPDATED STATE REQUIREMENT).
.
037. EROSION CONTROL QUANTITIES AND ITEMIZED COST ESTIMATE
MUST BE SUBMITTED FOR APPROVAL OF THE EROSION CONTROL
BOND AMOUNT. PLEASE ADDRESS.
.
-------- STORMWATER COMPUTATIONS --------
.
038. STORM DRAIN DESIGN COMPS SPREADSHEET: IT APPEARS SOME
OF THE "CA ACCUMULATED" CALCULATIONS ARE NOT ADDING
CORRECTLY. FOR EXAMPLE, STR41 FLOWS TO STR39, BUT THE
ASSOCIATED CA IS NOT ADDED. IT APPEARS IT HAS BEEN
ADDED TO THE LINE AT STR21 INSTEAD. ALSO, THE AREA TO
STR37 DOES NOT APPEAR TO INCLUDE THE FLOWS FROM THE
SOUTH CHESTER ROAD DITCH. PLEASE CONFIRM ALL DRAINAGE
AREAS AND ADDRESS.
.
039. HGL COMPS SPREADSHEET: THE QI FOR SEVERAL STRUCTURES IS
0.00 HOWEVER THEY SHOULD RECEIVE FLOW FROM UPSTREAM
STRUCTURES. THIS OCCURS AT STR25(QI=STR37),
STR39(QI=STR41), & STR29(QI=STR39). PLEASE ADDRESS.
.
040. STR45 IS LISTED AS AN INLET ON BOTH THE STORM DRAIN AND
HGL SPREADSHEETS, BUT IS LABELED AS A PIPE ON C9.
SHOULD THIS BE STR44?
.
041. CHANNEL REPORT OUTFALL C: FLOW RATE DOES NOT APPEAR TO
INCLUDE DRAINAGE FROM SOUTH CHESTER ROAD DITCH. PLEASE
RESUBMIT ALL CHANNEL REPORTS FOR THE ONSITE AND
PERIMETER DITCHES TO REFLECT THE CHANGES. PLEASE
ADDRESS.
.
-------- CBP COMPLIANCE --------
.
042: SHEET C14: REVISE SHEET TITLE TO CBPA COMPLIANCE /
DRAINAGE AREA MAP. UPDATE SHEET LIST ON COVER SHEET.
PLEASE INCLUDE THE MS-4 TABLE SHOWING THE REQUIRED
REMOVAL FOR THE SITE AND HOW WATER QUALITY COMPLIANCE
IS ACHIEVED THROUGH THE BIRKDALE LAKE REGIONAL WETPOND.
.
043. REMINDER, DEQ MAY NOT RECOGNIZE THE POLLUTION CREDITS
FROM THE BIRKDALE LAKE REGIONAL WETPOND BMP SINCE IT IS
NOT FROM STATE APPROVED NUTRIENT OFFSET BANK.
.
---- END OF ENV. ENG. COMMENTS ---
.
============================================================
============================================================