Subdivision Review Comments
All Subdivision Review Comments for Case # 14TS0192




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 14TS0192 STATUS: PENDING APPROVAL
PROJECT NAME: MILLERS RUN - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: TENTATIVE SUBDIVISION
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 02 12/21/15 01/15/16 ******** ********
ENVIR.ENGR.-: 02 12/21/15 01/15/16 AMENDED* 01/14/16 RPW 748-1028
FIRE DEPT.--: 02 12/21/15 01/15/16 AMENDED* 01/27/16 JKL 748-1489
HOUSE NUMBER: 02 12/21/15 01/15/16 ******** ********
MAPPING/GIS-: 02 12/21/15 01/15/16 ******** ********
PLANNING----: 02 12/21/15 01/15/16 COMPLETE 01/27/16 GWK 706-7691
PARKS & REC.: 02 12/21/15 01/15/16 ******** ********
SCHOOL BOARD: 02 12/21/15 01/15/16 ******** ********
SOILS-------: 02 12/21/15 01/15/16 ******** ********
TRANSPORT.--: 02 12/21/15 01/15/16 COMPLETE 01/11/16 SES 751-4912
UTIL.PLAN.--: 02 12/21/15 01/15/16 AMENDED* 02/04/16 TVM 751-4435
UTILITIES---: 02 12/21/15 01/15/16 ******** ********
UTIL.R.O.W.-: 02 12/21/15 01/15/16 ******** ********
VDOT--------: 02 12/21/15 01/15/16 ******** ********
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE # : TERRY MAPLES 751-4435
PLAN NAME: MILLERS RUN
PLAN NUMBER: 14TS0192
ORIGINAL PLAN DATE: 2/16/14
REVIEW DATE: 2/04/16
LATEST SUBMISSION DATE: 2/03/16
SUBMITTAL NUMBER: 4
STATUS: APPROVED
TABLE REVIEW:
NOTES:
1. THIS OFFICE MAY REQUIRE REDESIGN OR MODIFICATIONS TO
THE PROPOSED SEWER LAYOUT, AS SHOWN ON THE LATEST
TENTATIVE PLAN, ONCE THE FIELD WORK, GRADING PLAN
AND SEWER DESIGN HAS BEEN COMPLETED BY THE
ENGINEER AND SHOWN ON INITIAL CONSTRUCTION PLAN
SUBMITTAL FOR REVIEW AND APPROVAL. (U)
2.IT WILL BE THE RESPONSIBILITY OF THE SUB DIVIDER TO
MAKE CERTAIN, BY WHATEVER MEANS NECESSARY,
(I.E., ON-SITE WATER LINE LOOPING OR OFF-SITE
WATER LINE EXTENSIONS, ETC.) THAT THE DEMANDS
GENERATED BY THE PROPOSED PROJECT DO NOT
ADVERSELY AFFECT ANY PORTION OF THE PRESSURE
ZONE THE PROJECT IS LOCATED WITHIN AND THAT
THE ADDITION OF THIS PROJECT WILL NOT CAUSE ANY
AREA WITHIN THE PRESSURE ZONE TO FAIL TO COMPLY
WITH THE CHESTERFIELD COUNTY FIRE DEPARTMENT'S
REQUIRED FIRE FLOW OF 1000 GPM AT 20 PSI
RESIDUAL. (U)
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: MILLER'S RUN
CASE NUMBER: 14TS0192
LATEST PLAN DATE: 02/16/14
DEPT. REC'D. DATE: 04/16/14
SUBMITTAL NUMBER: ONE
REVIEW DATE: 05/05/14
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
1. PROFFERED CONDITION 8.A OF CASE 06SN0220 CONCERNS
CONSTRUCTION OF A TRAFFIC CALMING DEVICE IN JACOBS ROAD
EXTENDED. NO SUCH DEVICE IS SHOWN ON THE TENTATIVE. PROVIDE
AN EXPLANATION OF WHY THIS IS NOT SHOWN.
2. LABEL JACOBS ROAD EXTENDED AS A 70 FOOT COLLECTOR.
3. SIDEWALKS SHALL BE CONSTRUCTED ON BOTH SIDES OF
JACOBS ROAD EXTENDED.
4. LEFT AND RIGHT TURN LANES SHALL BE PROVIDED ALONG
JACOBS ROAD EXTENDED AT WABASSO LANE, PEAKLAND DRIVE, AND
AT ANY OTHER APPROVED ACCESS.
5. A TOTAL OF 90 LOTS ARE SHOWN, INCLUDING THE 64 LOTS
SHOWN, PLUS 26 SHOWN AS "POSSIBLE FUTURE DEVELOPMENT". THE
PROPERTY IS ONLY ZONED FOR 67 LOTS. NO DIRECT DRIVEWAY
ACCESS TO JACOBS ROAD EXTENDED WILL BE PERMITTED FOR THE
REMAINING 3 ZONED LOTS.
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: MILLER'S RUN
CASE NUMBER: 14TS0192
LATEST PLAN DATE: 06/02/15
DEPT. REC'D. DATE: 06/08/15
SUBMITTAL NUMBER: TWO
REVIEW DATE: 06/23/15
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: STEVEN E. SIMONSON, P.E. (804)748-1037
NAME OF PLAN: MILLER'S RUN
CASE NUMBER: 14TS0192
LATEST PLAN DATE: 12/20/15
DEPT. REC'D. DATE: 12/23/15
SUBMITTAL NUMBER: THREE
REVIEW DATE: 01/11/16
RECOMMENDATION: APPROVED
TABLE REVIEW: YES
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : AMY SOMERVELL / 751-4321
PLAN NAME : MILLERS RUN
PLAN NUMBER : 14TS0192
ORIGINAL PLAN DATE : 2-16-14
REVIEW DATE : 4-29-14
LATEST SUBMISSION DATE : 4-14-14
SUBMITTAL NUMBER : 1
STATUS : CORRECTIONS REQUIRED
TABLE REVIEW : N
1. CONDITION # 3 OF 06SN0220 CAPS THE DENSITY AT 67 LOTS.
THIS PLAN REFLECTS 64 LOTS WITH SEVERAL PIECES NOT ACCOUNTED
FOR. ADDITIONALLY, THERE ARE TWO EXISTING HOUSES ON SOME
OF THOSE PARCELS WHICH WOULD BRING THE DENSITY TO 66 WITH
PROPERTY STILL LEFT TO DEVELOP. THE OVERALL SHALL REFLECT
COMPLIANCE WITH THE ZONING CONDITION.
2.THE EXISTING DWELLING WHICH IS A PART OF THE PROPERTY
IS BEING DEVELOPED WILL NEED TO BE PART OF THIS REVIEW.
(IF THE DWELLING IS STILL IN USE) ALTERING THE PROPERTY
WHERE THE DWELLING EXISTS IS REQUIRED TO GO THROUGH SUB-
DIVISION REVIEW.
3.PROPOSED LT 15&61 WILL BE REQUIRED TO SHOW A BUILDING ENV
AT TIME OR CP AND FINAL PLAT UNLESS LAYOUT IS REVISED TO
GIVE A GREATER BUILDING AREA.
4. THE CHESTERFIELD HISTORICAL SOCIETY HAS NOTED A GRAVEYARD
ON THE SOUTH SIDE OF JACOBS RD @ 9109 JACOBS RD (RICHARDSON
PROPERTY). 4 GRAVES - 3 MARKED WITH FIELD STONES 1 UNMARKED.
ALTHOUGH THE GRAVE SITES ARE NOT WITHIN THE DEVELOPMENT,
CAUTION SHALL BE USED DURING THE CONSTRUCTION OF JACOBS
ROAD AS THE LOCATION OF THE GRAVE SITE COULD BE IMPACTED.
5. ADD THE TENTATIVE CASE NUMBER 14TS0192 IN THE BOTTOM
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : AMY SOMERVELL / 751-4321
PLAN NAME : MILLERS RUN
PLAN NUMBER : 14TS0192
ORIGINAL PLAN DATE : 2-16-15
REVIEW DATE : 7-6-15
LATEST SUBMISSION DATE : 6-3-15
SUBMITTAL NUMBER : 2
STATUS : CORECTIONS REQUIERD
1.REMOVE THE REFERENCES OF "POSSIBLE FUTURE DEVELOPMENT"
FROM THE OPEN SPACE AND LOT 2. FUTURE DEVELOPMENT WILL
REQUIRE A ZONING ACTION AND NEW PLAN SUBMITTAL FOR
DEVELOPMENT. THE LAYOUT WILL BE ADDRESS AT THAT TIME.
(ADDITIONALLY REMOVE THE GHOST LOT LINES AND CUL-DE-SAC)
2. 35' BUFFER IS REQUIRED ALONG JACOBS ROAD ON LOTS 1 & 2.
3. LOT 1 MAY NOT MEET REQUIRED SETBACKS OFF THE REQUIRED
BUFFER FOR A FRONT YARD. A VARIANCE MAY BE REQUIRED.
4. LOT 45 IS REQUIRED TO HAVE 50 FEET OF STATE ROAD
FRONTAGE. AT TIME OF CONSTRUCTION PLANS PEAKLAND DRIVE
SHALL BE BUILT TO THIS EXTENT. (NOTE)
5. THE 20' OPEN SPACE ALONG FORDAM ROAD IS NOT REQUIRED BY
ORDINANCE. THIS CAN BE REMOVED AT THE DISCRETION OF THE
DEVELOPER
6. THE RESIDUAL OF THIS PROPERTY, ZONED A, WILL NOT
ELIGIBLE FOR RESIDENTIAL BUILDING PERMITS. THE RESIDUAL
DOES NOT MEET MINIMUM ORDINANCE STANDARDS.
____________________________________________________________
REVIEW DEPARTMENT: PLANNING
REVIEWER / PHONE #: WHIT KIRTLEY / 706-7691
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : WHIT KIRTLEY / 706-7691
PLAN NAME : MILLERS RUN 6/14
PLAN NUMBER : 14TS0192
ORIGINAL PLAN DATE : 2-16-15 /15
REVIEW DATE : 1/27/15
LATEST SUBMISSION DATE : 12/21/15
SUBMITTAL NUMBER : 3
STATUS : CORECTIONS REQUIERD
NOTES:
1. LOT 45 IS REQUIRED TO HAVE 50 FEET OF STATE ROAD
FRONTAGE. AT TIME OF CONSTRUCTION PLANS PEAKLAND DRIVE
SHALL BE BUILT TO THIS EXTENT.
2. THE RESIDUAL OF THIS PROPERTY, ZONED A, WILL NOT
ELIGIBLE FOR RESIDENTIAL BUILDING PERMITS. THE RESIDUAL
DOES NOT MEET MINIMUM ORDINANCE STANDARDS.
3. THE CHESTERFIELD HISTORICAL SOCIETY HAS NOTED A GRAVEYARD
ON THE SOUTH SIDE OF JACOBS RD @ 9109 JACOBS RD (RICHARDSON
PROPERTY). 4 GRAVES - 3 MARKED WITH FIELD STONES 1 UNMARKED.
ALTHOUGH THE GRAVE SITES ARE NOT WITHIN THE DEVELOPMENT,
CAUTION SHALL BE USED DURING THE CONSTRUCTION OF JACOBS
ROAD AS THE LOCATION OF THE GRAVE SITE COULD BE IMPACTED
REVIEW DEPARTMENT : FIRE DEPARTMENT
REVIEWER / PHONE # : KIM LESTER / (804) 748-1489
PLAN NAME : MILLERS RUN
PLAN NUMBER: : 14TS0192
LATEST PLAN DATE : 2/16/14
REVIEW DATE : 3/25/14
DEPARTMENT RECEIVED DATE: 4/8/14
SUBMITTAL NUMBER : 1ST REVIEW
STATUS : NOT APPROVED
TABLE REVIEW:
CONDITION:
1. COMPLIANCE WITH 17-76 OF THE SUBDIVISION ORDINANCE
IN THE CHESTERFIELD CODE SHALL BE MAINTAINED AT ALL
TIMES.
COMMENTS:
1. THE PLAN NEEDS TO REFLECT THE EMERGENCY ACCESS THAT WAS
CONDITION DURING THE ZONING PROCESS. THE EMERGENCY ACCESS
IS TO BE CONSTRUCTED AT NEWBYS WOOD TRAIL.
2. HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S)
REQUIRED AND THEIR LOCATION WILL BE EVALUATED AT
THE TIME OF CONSTRUCTION PLAN REVIEW.
***********************************************************
************************************************************
REVIEW DEPARTMENT : FIRE DEPARTMENT
REVIEWER / PHONE # : KIM LESTER / (804) 748-1489
PLAN NAME : MILLERS RUN
PLAN NUMBER : 14TS0192
LATEST PLAN DATE : 6/2/15
REVIEW DATE : 6/8/15
DEPARTMENT RECEIVED DATE: 6/8/15
SUBMITTAL NUMBER : 2ND REVIEW
STATUS : APPROVED
TABLE REVIEW:
HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S)
REQUIRED AND THEIR LOCATION WILL BE EVALUATED AT
THE TIME OF CONSTRUCTION PLAN REVIEW.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT : FIRE DEPARTMENT
REVIEWER / PHONE # : KIM LESTER / (804) 748-1489
PLAN NAME : MILLERS RUN
PLAN NUMBER : 14TS0192
LATEST PLAN DATE : 12/20/15
REVIEW DATE : 1/7/16
DEPARTMENT RECEIVED DATE: 12/24/15
SUBMITTAL NUMBER : 3RD REVIEW
STATUS : APPROVED
TABLE REVIEW: YES
HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S)
REQUIRED AND THEIR LOCATION WILL BE EVALUATED AT
THE TIME OF CONSTRUCTION PLAN REVIEW.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT : FIRE DEPARTMENT
REVIEWER / PHONE # : KIM LESTER / (804) 748-1489
PLAN NAME : MILLERS RUN
PLAN NUMBER : 14TS0192
LATEST PLAN DATE : 2/3/16
REVIEW DATE : 2/4/16
DEPARTMENT RECEIVED DATE: 2/3/16
SUBMITTAL NUMBER : 4TH REVIEW
STATUS : APPROVED
TABLE REVIEW: YES
HYDRANT REQUIREMENTS AND LOCATIONS SHOWN ON THE
TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S)
REQUIRED AND THEIR LOCATION WILL BE EVALUATED AT THE TIME
OF CONSTRUCTION PLAN REVIEW.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
PLAN NAME: MILLERS RUN
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: L. D. PRITCHARD, JR. / 748-1028
PLAN NUMBER: 14TS0192
ORIGINAL PLAN DATE: FEBRUARY 16, 2014
PLANNER: AMY SOMMERVELL
ENGINEER: BALZER (TODD CHALMERS)
UPDATED: MAY 13, 2015
REVIEW DATE: JUNE 15, 2015
SUBMITTAL NUMBER: 2
STATUS: REVISIONS REQUESTED
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS THE
FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS
PERTAINING TO THE ABOVE REFERENCED TENTATIVE PLAT REVISED
JUNE 2, 2015, RECEIVED BY THE PLANNING DEPARTMENT ON
JUNE 3, 2015, AND RECEIVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT ON JUNE 4, 2015.
….
THE CBPA NOTE WHICH SAYS CBPA COMPLIANCE ACHIEVED
THROUGH THE AVAILABLE LOT SIZE NOT EXCEEDING 10%
IMPERVIOUS DEFAULT IS NOT MAKING SENSE. IN FACT, EVEN THE
16% IMPERVIOUSNESS DEFAULT DOES NOT WORK AS THERE ARE 67
LOTS DISTRIBUTED OVER 64.74 ACRES OF LOTS AND OPEN SPACE.
PLEASE ADDRESS.
….
SINCE NEWBYS WOOD TRAIL WILL NOT INTERSECT WITH JACOBS
ROAD, THE GAP IN THE SIDEWALK SHOULD BE FILLED IN WITH THE
SPECIFICATION OF A 7 INCH DEPTH, FOR THE WIDTH OF THE GATE.
….
PLEASE PROVIDE AN UPDATED PRELIMINARY CBPA PLAN FOR
MILLERS RUN. AMONG THE MANY DISCREPANCIES, THE
WORKSHEET A INDICATES A SITE AREA OF 55.85 ACRES WHEREAS THE
NEWLY SUBMITTED MILLERS RUN INDICATES A TOTAL ACREAGE OF
74.46 ACRES. PLEASE ADDRESS.
….
PLEASE PROVIDE A LETTER FROM THE RECOGNIZED WETLAND
EXPERT REGARDING THE ACCURACY OF THE WETLANDS DELINEATION
PORTRAYED ON THE TENTATIVE PLAT THAT IS THE BASIS FOR THE
RPA-LIMITS ESTABLISHMENT. SUGGESTED WORDING IS, "I HAVE
VIEWED THE TENTATIVE PLAT FOR MILLERS RUN DATED FEBRUARY
16, 2014 BY BALZER AND ASSOCIATES AND FIND THAT IT
PORTRAYS AN ACCURATE REPRESENTATION OF MY FIELD
DELINEATION
OF THE WETLANDS LOCATED WITHIN THE RESOURCE PROTECTION
AREAS OF THE PROJECT. THIS LETTER COULD NOT BE LOCATED IN
PACKAGE RECEIVED.
….
AN ASSESSMENT OF THE TOPOGRAPHY IN RELATION TO THE LOT
LAYOUT HAS REVEALED SEVERAL AREAS OF STORM WATER
CONCENTRATION WHICH ARE IN POTENTIAL CONFLICT WITH THE
DESIRE NOT TO HAVE STORM DRAINAGE PROBLEMS RELATED TO THE
DEVELOPMENT OF THE HOUSE AND LOT. THESE ARE ENGINEERING
ISSUES WHICH SHOULD BE ADDRESSED BY THE CONSTRUCTION
PLANS AND NOT LEFT TO THE INDIVIDUAL BUILDERS TO DEAL
WITH.
THE PHYSICAL "LOW" OF THESE DRAINAGE CORRIDORS SHOULD BE
FIELD LOCATED AND APPROPRIATE ENGINEERING PROPOSALS WITH
RESPECT TO FILLING, GRADING, DRAINAGE STORM SEWERING AND
BUILDING ENVELOPE LOCATIONS SHOULD BE MADE A PART OF THE
CONSTRUCTION PLANS. THESE AREAS ARE AS FOLLOWS:
….
A. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 6, PASSING
THROUGH THE CENTER OF LOT 10, CONTINUING ON THROUGH LOT 15
AND ULTIMATELY REACHING THE RPA, AFTER HAVING PASSED
THROUGH LOT 18.
….
B. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 36, PASSING
THROUGH LOT 39, BEFORE REACHING PEAKLAND DRIVE.
….
C. THE DRAINAGE CORRIDOR WHICH BEINGS IN LOT 59, PASSING
THROUGH THE CENTER OF LOT 62 BEFORE REACHING THE RPA.
….
TENTATIVE CONDITIONS COULD INCLUDE BUT NOT BE LIMITED TO
THE
FOLLOWING:
….
1. A DAM-FAILURE ANALYSIS SHALL, AT A MINIMUM, BE
PERFORMED BASED ON AN OVER-TOPPING BREACH OF THE DAM
EMBANKMENT DURING A 100 YEAR STORM EVENT. CRITERIA PER
THE VIRGINIA DAM SAFETY ACT WILL TAKE PRECEDENCE.
EXISTING OR PROPOSED HOMES SHALL BE OUTSIDE OF THE DAM
FAILURE INUNDATION LIMITS.
….
2. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
….
3. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE
ENVIRONMENTAL
ENGINEERING DEPARTMENT MUST HAVE RECEIVED
DOCUMENTATION THAT THE SUB-DIVIDER OR HIS REPRESENTATIVE
HAS NOTIFIED CERTAIN PROPERTY OWNERS DETERMINED BY THE
DEPARTMENT OF THE PROPOSED ADJACENT CONSTRUCTION.
(PARKER, ANGELA JANE, 9001 DOUBLE TREE LANE)
….
4. ALL EXPENSES INVOLVED IN THE ELIMINATION OF THE
TEMPORARY CUL DE SAC ON EXISTING DOUBLE TREE LANE AND THE
EXTENSION WITHIN EXISTING RIGHT OF WAY OF DOUBLE TREE
LANE
INTO THE PROJECT WILL BE BORNE BY THE DEVELOPER.
….
5. THE AREAS OF STORM-WATER RUNOFF CONCENTRATION AS
DISCUSSED IN THE ENVIRONMENTAL ENGINEERING DEPARTMENT
TENTATIVE REPORT DATED JUNE 12, 2015 WILL BE FIELD
LOCATED
AND SHOWN ON THE PLANS. THE CONSTRUCTION PLANS SHALL
DESIGNATE THE AFFECTED LOTS WITH AN NBP, AND AN
ENGINEERED STORM SEWER, FILLING, GRADING, AND DRAINAGE
PLAN SHALL BE INCLUDED IN THE CONSTRUCTION PLANS.
….
6. THE SUB-DIVIDER SHALL POST SIGNS DEMARKING THE LIMITS
OF THE RPA AREA SO BUILDERS AND HOMEOWNERS MAY BE
INFORMED AS TO THE LIMITATIONS IMPOSED ON THESE AREAS.
SPECIFIC PLANS FOR THE EXACT NUMBER AND PLACEMENT OF THE
SIGNS SHALL BE APPROVED BY THE ENVIRONMENTAL ENGINEERING
DEPARTMENT.
….
7. THE POINTS OF PERENNIAL FLOW ALONG WITH THEIR GPS
COORDINATE VALUES WILL BE SHOWN ON THE CONSTRUCTION
PLAN
AND RECORD PLAT.
….
8. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE LAKE WILL BE RETROFITTED TO
ACHIEVE A MINIMUM SHALLOWNESS OF 3 FEET, TO ESTABLISH
FOREBAYS IN LOCATIONS TO BE DETERMINED AT THE TIME OF
CONSTRUCTION PLAN REVIEW, A MECHANICAL DE-WATERING
DEVICE PLACED ON THE PRINCIPAL SPILLWAY AND ALL APPLICABLE
SAFETY MEASURES AS SPECIFIED IN THE CHESAPEAKE BAY
ORDINANCE
….
9. THE PEDESTRIAN-ACCESS FACILITIES DESIGN AS SHOWN ON THE
TENTATIVE SHALL BE INCLUDED IN THE ROAD AND DRAINAGE PLANS
THAT MUST BE APPROVED BY BOTH VDOT AND THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. ROAD RIGHT-OF-
WAY SHALL BE WIDE ENOUGH TO ENCOMPASS THE PEDESTRIAN-
ACCESS FACILITIES IF THE SIDEWALKS MEET STATE CRITERIA.
….
10. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE SPILLWAY STRUCTURE FOR THE WET
POND(S) SHALL BE A CONCRETE WEIR.
….
11. APPROVAL OF THE ROAD AND DRAINAGE PLANS BY VIRGINIA
POWER IN RELATION TO ITS EASEMENT AND FACILITIES
THEREIN IS A PREREQUISITE TO CONSTRUCTION PLAN APPROVAL BY
THE ENVIRONMENTAL ENGINEERING DEPARTMENT. A
SUBORDINATION OF RIGHTS TO VDOT OR A SATISFACTORY
COMMITMENT THEREOF BY VIRGINIA POWER FOR THE LOCATION
WHERE JACOBS ROAD AND DOUBLE TREE LANE RIGHT-OF WAY
WILL CROSS THE VIRGINIA POWER EASEMENT SHALL BE A
PREREQUISITE TO SUBDIVISION PLAT RECORDATION.
….
12. APPROVAL OF THE ROAD AND DRAINAGE PLANS BY
COMMONWEALTH GAS IN RELATION TO ITS EASEMENT AND
FACILITIES THEREIN IS A PREREQUISITE TO CONSTRUCTION PLAN
APPROVAL BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT.
A SUBORDINATION OF RIGHTS TO COMMONWEALTH GAS OR A
SATISFACTORY COMMITMENT THEREOF BY COMMONWEALTH GAS
FOR THE LOCATION WHERE JACOBS ROAD AND DOUBLE TREE LANE
RIGHT-OF-WAY WILL CROSS THE COMMONWEALTH GAS EASEMENT
SHALL BE A PREREQUISITE TO SUBDIVISION PLAT RECORDATION.
….
13. WITH REFERENCE TO THE EXISTING POND WHICH IS TO REMAIN
AS AN AMENITY, AN ENGINEERING AND GEOTECHNICAL CLEAN BILL OF
HEALTH WILL BE ACHIEVED FOR THIS FACILITY. ALSO, THE RECORD
PLAT WILL CLARIFY THE SPECIFIC LOT OWNERS WHO WILL HAVE
PERMANENT MAINTENANCE AND OPERATIONS RESPONSIBILITIES.
….
14. UNLESS OTHERWISE APPROVED, THE CONSTRUCTION ACTIVITIES
ON THE AMENITY LAKE AND DAM WHICH WILL OCCUR WITHIN THE
RPA LIMITS SHALL BE AUTHORIZED BY ISSUANCE OF AN APPROVAL
OF A WQIA FROM THE WATER SECTION OF THE ENVIRONMENTAL
ENGINEERING DEPARTMENT.
….
(PLEASE PLACE ON DEVELOPER LETTERHEAD)
(DATE)
KIRKLAND A. TURNER, DIRECTOR
CHESTERFIELD COUNTY PLANNING DEPARTMENT
P. O. BOX 40
CHESTERFIELD, VIRGINIA 23832
RE: ENTRANCE EMBELLISHMENTS (____________ TENTATIVE)
DEAR MR. TURNER:
AS DEVELOPER OF THE PROPOSED __________________
SUBDIVISION, I AM AWARE THAT THE FOLLOWING NOTE IS NOW
REQUIRED NOT ONLY ON TENTATIVE BUT ALSO ON RECORD PLATS.
"NO STRUCTURE EMBELLISHMENTS WILL BE ALLOWED ON VDOT
RIGHT-OF-WAY WITHOUT THE COMMITMENT OF, OR THE ISSUANCE OF,
A VDOT LAND USE PERMIT. WITHIN THE 10' CLEAR ZONE
(MEASURED FROM THE EDGE OF THE ROADWAY'S PAVEMENT OUT
10'), NO STRUCTURE EMBELLISHMENT WILL BE PERMITTED THAT IS
CLOSER THAN 3' FROM THE EDGE OF PAVEMENT OF THE PUBLIC
STREET OR HIGHER THAN 6" ABOVE THE SURFACE OF THE DRIVE."
I WILL DO ALL POSSIBLE TO PROVIDE THE CORRECT INFORMATION
FOR
BUILDERS OR CITIZENS CONSTRUCTING ENTRANCE EMBELLISHMENTS.
I AM ALSO AWARE THAT, PRIOR TO STATE ACCEPTANCE OF THE
ROADS, I AM RESPONSIBLE FOR REMOVING EMBELLISHMENTS THAT
DO NOT MEET STATE STANDARDS.
SINCERELY,
DEVELOPER NAME (PRINTED)
DEVELOPER SIGNATURE (DATE)
**********************************
PLAN NAME: MILLERS RUN
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: REBECCAH P. WARD / 748-1977
PLAN NUMBER: 14TS0192
ORIGINAL PLAN DATE: 02/16/14
LATEST SUBMISSION DATE: 12/20/15
REVIEW DATE: 01/15/16
SUBMITTAL NUMBER: 3
STATUS: REVISION REQUESTED
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS THE
FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS PERTAINING
TO THE ABOVE REFERENCED PRELIMINARY PLAN DATED 12/20/15,
RECEIVED BY THE PLANNING DEPARTMENT ON 12/21/15, AND BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT ON 12/22/15.
1. NOTE 2 OF THE GENERAL NOTES ON SHEET 1 INDICATES THAT
CBPA COMPLIANCE IS ACHIEVED THROUGH THE PURCHASE OF CREDITS
FROM AN APPROVED OFFSITE CREDIT BANK. PROVIDE A COPY OF THE
AGREEMENT THAT CREDITS WILL BE PURCHASED FROM AN APPROVED
DEQ CREDIT BANK OR ADDRESS WATER QUALITY USING ONSITE BMPS.
2. ON WORKSHEET A FOR THE PART IIC POST-DEVELOPMENT LOCATING
CALCULATIONS, THE AVERAGE LOT SIZE SHOULD BE CALCULATED
USING THE AREA IN THE LOTS AND OPEN SPACE DIVIDED BY THE
TOTAL NUMBER OF LOTS. THIS NUMBER SHOULD BE USED TO
DETERMINE THE FPOST FOR THE ENTIRE SITE MINUS THE
NON-FRONTAGE RIGHT OF WAY FOR JACOBS ROAD. THE AREA OF THE
NON-FRONTAGE RIGHT OF WAY FOR JACOBS ROAD SHOULD BE
CALCULATED SEPARATE AND ADDED TO THE TOTAL LPOST FOR THE
REMAINDER OF THE SITE.
NOTES:
AN ASSESSMENT OF THE TOPOGRAPHY IN RELATION TO THE LOT
LAYOUT HAS REVEALED SEVERAL AREAS OF STORM WATER
CONCENTRATION WHICH ARE IN POTENTIAL CONFLICT WITH THE
DESIRE NOT TO HAVE STORM DRAINAGE PROBLEMS RELATED TO THE
DEVELOPMENT OF THE HOUSE AND LOT. THESE ARE ENGINEERING
ISSUES WHICH SHOULD BE ADDRESSED BY THE CONSTRUCTION PLANS
AND NOT LEFT TO THE INDIVIDUAL BUILDERS TO DEAL WITH. THE
PHYSICAL "LOW" OF THESE DRAINAGE CORRIDORS SHOULD BE FIELD
LOCATED AND APPROPRIATE ENGINEERING PROPOSALS WITH RESPECT
TO FILLING, GRADING, DRAINAGE STORM SEWERING, AND BUILDING
ENVELOPE LOCATIONS SHOULD BE MADE A PART OF THE CONSTRUCTION
PLANS. THESE AREAS ARE AS FOLLOWS:
A. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 6, PASSING
THROUGH THE CENTER OF LOT 10, CONTINUING ON THROUGH LOT 15
AND ULTIMATELY REACHING THE RPA, AFTER HAVING PASSED THROUGH
LOT 18.
B. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 36, PASSING
THROUGH LOT 39, BEFORE REACHING PEAKLAND DRIVE.
C. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 59, PASSING
THROUGH THE CENTER OF LOT 62 BEFORE REACHING THE RPA.
TENTATIVE CONDITIONS COULD INCLUDE, BUT NOT BE LIMITED TO
THE FOLLOWING:
1. A DAM-FAILURE ANALYSIS SHALL, AT A MINIMUM, BE PERFORMED
BASED ON AN OVER-TOPPING BREACH OF THE DAM EMBANKMENT DURING
A 100 YEAR STORM EVENT. CRITERIA PER THE VIRGINIA DAM
SAFETY ACT WILL TAKE PRECEDENCE. EXISTING OR PROPOSED HOMES
SHALL BE OUTSIDE OF THE DAM FAILURE INUNDATION LIMITS.
2. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
3. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE ENVIRONMENTAL
ENGINEERING DEPARTMENT MUST HAVE RECEIVED DOCUMENTATION THAT
THE SUB-DIVIDER OR HIS REPRESENTATIVE HAS NOTIFIED CERTAIN
PROPERTY OWNERS, DETERMINED BY THE DEPARTMENT, OF THE
PROPOSED ADJACENT CONSTRUCTION (PARKER, ANGELA JANE, 9001
DOUBLE TREE LANE).
4. ALL EXPENSES INVOLVED IN THE ELIMINATION OF THE TEMPORARY
CUL-DE-SAC ON EXISTING DOUBLE TREE LANE INTO THE PROJECT
WILL BE BORNE BY THE DEVELOPER.
5. THE AREAS OF STORMWATER RUNOFF CONCENTRATION AS DISCUSSED
IN THE ENVIRONMENTAL ENGINEERING DEPARTMENT TENTATIVE
REPORT, DATED JUNE 12, 2015, WILL BE FIELD LOCATED AND SHOWN
ON THE PLANS. THE CONSTRUCTION PLANS SHALL DESIGNATE THE
AFFECTED LOTS WITH AN NBP, AND AN ENGINEERED STORM SEWER,
FILLING, GRADING AND DRAINAGE PLAN SHALL BE INCLUDED IN THE
CONSTRUCTION PLANS.
6. THE SUB-DIVIDER SHALL POST SIGNS DEMARKING THE LIMITS OF
THE RPA AREA SO BUILDERS AND HOMEOWNERS MAY BE INFORMED AS
TO THE LIMITATIONS IMPOSED ON THESE AREAS. SPECIFIC PLANS
FOR THE EXACT NUMBER AND PLACEMENT OF THE SIGNS SHALL BE
APPROVED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT.
7. THE POINTS OF PERENNIAL FLOW ALONG WITH THEIR GPS
COORDINATE VALUES WILL BE SHOWN ON THE CONSTRUCTION PLAN AND
RECORD PLAT.ALL BE INCLUDED IN THE ROAD AND DRAINAGE PLANS
8. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE LAKE WILL BE RETROFITTED TO
ACHIEVE A MINIMUM SHALLOWNESS OF 3 FEET, TO ESTABLISH
FOREBAYS IN LOCATIONS TO BE DETERMINED AT THE TIME OF
CONSTRUCTION PLAN REVIEW, A MECHANICAL DEWATERING DEVICE
PLACED ON THE PRINCIPAL SPILLWAY AND ALL APPLICABLE SAFETY
MEASURES AS SPECIFIED IN THE CHESAPEAKE BAY ORDINANCE.
9. THE PEDESTRIAN-ACCESS FACILITIES DESIGN AS SHOWN ON THE
PRELIMINARY PLAT SHALL BE INCLUDED IN THE ROAD AND DRAINAGE
PLANS THAT MUST BE APPROVED BY BOTH VDOT AND THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. ROAD RIGHT-OF-WAY
SHALL BE WIDE ENOUGH TO ENCOMPASS THE PEDESTRIAN-ACCESS
FACILITIES IF THE SIDEWALKS MEET STATE CRITERIA.
10. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE SPILLWAY STRUCTURE FOR THE WET
POND(S) SHALL BE A CONCRETE WEIR.
11. APPROVAL OF THE ROAD AND DRAINAGE PLANS BY VIRGINIA
POWER IN RELATION TO ITS EASEMENT AND FACILITIES THEREIN IS
A PREREQUISITE TO CONSTRUCTION PLAN APPROVAL BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. A SUBORDINATION OF
RIGHTS TO VDOT OR A SATISFACTORY COMMITMENT THEREOF BY
VIRGINIA POWER FOR THE LOCATION WHERE JACOBS ROAD AND DOUBLE
TREE LANE RIGHTS-OF-WAY CROSS THE VIRGINIA POWER EASEMENT
SHALL BE A PREREQUISITE TO SUBDIVISION PLAT RECORDATION.
12. APPROVAL OF THE ROAD AND DRAINAGE PLANS BY COMMONWEALTH
GAS IN RELATION TO ITS EASEMENT AND FACILITIES THEREIN IS A
PREREQUISITE TO CONSTRUCTION PLAN APPROVAL BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. A SUBORDINATION OF
RIGHTS TO COMMONWEALTH GAS OR A SATISFACTORY COMMITMENT
THEREOF BY COMMONWEALTH GAS FOR THE LOCATION WHERE JACOBS
ROAD AND DOUBLE TREE LANE RIGHTS-OF-WAY WILL CROSS THE
COMMONWEALTH GAS EASEMENT SHALL BE A PREREQUISITE TO
SUBDIVISION PLAT RECORDATION.
13. WITH REFERENCE TO THE EXISTING POND WHICH IS TO REMAIN
AS AN AMENITY, AN ENGINEERING AND GEOTECHNICAL CLEAN BILL OF
HEALTH WILL BE ACHIEVED FOR THIS FACILITY. ALSO, THE RECORD
PLAT WILL CLARIFY THE SPECIFIC LOT OWNERS WHO WILL HAVE
PERMANENT MAINTENANCE AND OPERATIONS RESPONSIBILITIES.
14. UNLESS OTHERWISE APPROVED, THE CONSTRUCTION ACTIVITIES
ON THE AMENITY LAKE AND DAM WHICH WILL OCCUR WITHIN THE RPA
LIMITS SHALL BE AUTHORIZED BY ISSUANCE OF AN APPROVAL OF A
WQIA FROM THE WATER QUALITY SECTION OF THE ENVIRONMENTAL
ENGINEERING DEPARTMENT.
15. PRIOR TO CONSTRUCTION PLAN APPROVAL, DOCUMENTATION OF
THE OWNER'S ACQUISITION OF THE REQUIRED NONPOINT NUTRIENT
OFFSETS MUST BE PROVIDED IN A CERTIFICATION FROM THE OFFSET
BROKER DOCUMENTING THE NUMBER OF PHOSPHOROUS NONPOINT
NUTRIENT OFFSETS ACQUIRED AND THE ASSOCIATED RATIO OF
NITROGEN NONPOINT NUTRIENT OFFSETS AT THE OFFSET GENERATING
FACILITY.
****************************************
PLAN NAME: MILLERS RUN
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: REBECCAH P. WARD / 748-1977
PLAN NUMBER: 14TS0192
ORIGINAL PLAN DATE: 02/16/14
LATEST SUBMISSION DATE: 02/04/16
REVIEW DATE: 02/04/16
SUBMITTAL NUMBER: 4
STATUS: READY FOR APPROVAL
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS THE
FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS PERTAINING
TO THE ABOVE REFERENCED PRELIMINARY PLAN DATED 02/03/16,
RECEIVED BY THE PLANNING DEPARTMENT ON 02/04/16, AND BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT ON 02/04/16.
TENTATIVE CONDITIONS INCLUDE THE FOLLOWING:
1. A DAM-FAILURE ANALYSIS SHALL, AT A MINIMUM, BE PERFORMED
BASED ON AN OVER-TOPPING BREACH OF THE DAM EMBANKMENT DURING
A 100 YEAR STORM EVENT. CRITERIA PER THE VIRGINIA DAM
SAFETY ACT WILL TAKE PRECEDENCE. EXISTING OR PROPOSED HOMES
SHALL BE OUTSIDE OF THE DAM FAILURE INUNDATION LIMITS.
2. THE NAME OF THE GEOTECHNICAL PROFESSIONAL WHO WILL
PROVIDE THE GEOTECHNICAL APPROVAL ON THE DAM WILL BE
FURNISHED PRIOR TO THE ISSUANCE OF THE LAND DISTURBANCE
PERMIT.
3. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE ENVIRONMENTAL
ENGINEERING DEPARTMENT MUST HAVE RECEIVED DOCUMENTATION THAT
THE SUB-DIVIDER OR HIS REPRESENTATIVE HAS NOTIFIED CERTAIN
PROPERTY OWNERS, DETERMINED BY THE DEPARTMENT, OF THE
PROPOSED ADJACENT CONSTRUCTION (PARKER, ANGELA JANE, 9001
DOUBLE TREE LANE).
4. ALL EXPENSES INVOLVED IN THE ELIMINATION OF THE TEMPORARY
CUL-DE-SAC ON EXISTING DOUBLE TREE LANE INTO THE PROJECT
WILL BE BORNE BY THE DEVELOPER.
5. THE AREAS OF STORMWATER RUNOFF CONCENTRATION AS DISCUSSED
IN THE ENVIRONMENTAL ENGINEERING DEPARTMENT TENTATIVE
REPORT, DATED JUNE 12, 2015, WILL BE FIELD LOCATED AND SHOWN
ON THE PLANS. THE CONSTRUCTION PLANS SHALL DESIGNATE THE
AFFECTED LOTS WITH AN NBP, AND AN ENGINEERED STORM SEWER,
FILLING, GRADING AND DRAINAGE PLAN SHALL BE INCLUDED IN THE
CONSTRUCTION PLANS.
6. THE SUB-DIVIDER SHALL POST SIGNS DEMARKING THE LIMITS OF
THE RPA AREA SO BUILDERS AND HOMEOWNERS MAY BE INFORMED AS
TO THE LIMITATIONS IMPOSED ON THESE AREAS. SPECIFIC PLANS
FOR THE EXACT NUMBER AND PLACEMENT OF THE SIGNS SHALL BE
APPROVED BY THE ENVIRONMENTAL ENGINEERING DEPARTMENT.
7. THE POINTS OF PERENNIAL FLOW ALONG WITH THEIR GPS
COORDINATE VALUES WILL BE SHOWN ON THE CONSTRUCTION PLAN AND
RECORD PLAT.
8. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE LAKE WILL BE RETROFITTED TO
ACHIEVE A MINIMUM SHALLOWNESS OF 3 FEET, TO ESTABLISH
FOREBAYS IN LOCATIONS TO BE DETERMINED AT THE TIME OF
CONSTRUCTION PLAN REVIEW, A MECHANICAL DEWATERING DEVICE
PLACED ON THE PRINCIPAL SPILLWAY AND ALL APPLICABLE SAFETY
MEASURES AS SPECIFIED IN THE CHESAPEAKE BAY ORDINANCE.
9. THE PEDESTRIAN-ACCESS FACILITIES DESIGN AS SHOWN ON THE
PRELIMINARY PLAT SHALL BE INCLUDED IN THE ROAD AND DRAINAGE
PLANS THAT MUST BE APPROVED BY BOTH VDOT AND THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. ROAD RIGHT-OF-WAY
SHALL BE WIDE ENOUGH TO ENCOMPASS THE PEDESTRIAN-ACCESS
FACILITIES IF THE SIDEWALKS MEET STATE CRITERIA.
10. UNLESS OTHERWISE APPROVED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT, THE SPILLWAY STRUCTURE FOR THE WET
POND(S) SHALL BE A CONCRETE WEIR.
11. APPROVAL OF THE ROAD AND DRAINAGE PLANS BY VIRGINIA
POWER IN RELATION TO ITS EASEMENT AND FACILITIES THEREIN IS
A PREREQUISITE TO CONSTRUCTION PLAN APPROVAL BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. A SUBORDINATION OF
RIGHTS TO VDOT OR A SATISFACTORY COMMITMENT THEREOF BY
VIRGINIA POWER FOR THE LOCATION WHERE JACOBS ROAD AND DOUBLE
TREE LANE RIGHTS-OF-WAY CROSS THE VIRGINIA POWER EASEMENT
SHALL BE A PREREQUISITE TO SUBDIVISION PLAT RECORDATION.
12. APPROVAL OF THE ROAD AND DRAINAGE PLANS BY COMMONWEALTH
GAS IN RELATION TO ITS EASEMENT AND FACILITIES THEREIN IS A
PREREQUISITE TO CONSTRUCTION PLAN APPROVAL BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. A SUBORDINATION OF
RIGHTS TO COMMONWEALTH GAS OR A SATISFACTORY COMMITMENT
THEREOF BY COMMONWEALTH GAS FOR THE LOCATION WHERE JACOBS
ROAD AND DOUBLE TREE LANE RIGHTS-OF-WAY WILL CROSS THE
COMMONWEALTH GAS EASEMENT SHALL BE A PREREQUISITE TO
SUBDIVISION PLAT RECORDATION.
13. WITH REFERENCE TO THE EXISTING POND WHICH IS TO REMAIN
AS AN AMENITY, AN ENGINEERING AND GEOTECHNICAL CLEAN BILL OF
HEALTH WILL BE ACHIEVED FOR THIS FACILITY. ALSO, THE RECORD
PLAT WILL CLARIFY THE SPECIFIC LOT OWNERS WHO WILL HAVE
PERMANENT MAINTENANCE AND OPERATIONS RESPONSIBILITIES.
14. UNLESS OTHERWISE APPROVED, THE CONSTRUCTION ACTIVITIES
ON THE AMENITY LAKE AND DAM WHICH WILL OCCUR WITHIN THE RPA
LIMITS SHALL BE AUTHORIZED BY ISSUANCE OF AN APPROVAL OF A
WQIA FROM THE WATER QUALITY SECTION OF THE ENVIRONMENTAL
ENGINEERING DEPARTMENT.
15. PRIOR TO CONSTRUCTION PLAN APPROVAL, DOCUMENTATION OF
THE OWNER'S ACQUISITION OF THE REQUIRED NONPOINT NUTRIENT
OFFSETS MUST BE PROVIDED IN A CERTIFICATION FROM THE OFFSET
BROKER DOCUMENTING THE NUMBER OF PHOSPHOROUS NONPOINT
NUTRIENT OFFSETS ACQUIRED AND THE ASSOCIATED RATIO OF
NITROGEN NONPOINT NUTRIENT OFFSETS AT THE OFFSET GENERATING
FACILITY.
REVIEW NOTES:
AN ASSESSMENT OF THE TOPOGRAPHY IN RELATION TO THE LOT
LAYOUT HAS REVEALED SEVERAL AREAS OF STORM WATER
CONCENTRATION WHICH ARE IN POTENTIAL CONFLICT WITH THE
DESIRE NOT TO HAVE STORM DRAINAGE PROBLEMS RELATED TO THE
DEVELOPMENT OF THE HOUSE AND LOT. THESE ARE ENGINEERING
ISSUES WHICH SHOULD BE ADDRESSED BY THE CONSTRUCTION PLANS
AND NOT LEFT TO THE INDIVIDUAL BUILDERS TO DEAL WITH. THE
PHYSICAL "LOW" OF THESE DRAINAGE CORRIDORS SHOULD BE FIELD
LOCATED AND APPROPRIATE ENGINEERING PROPOSALS WITH RESPECT
TO FILLING, GRADING, DRAINAGE STORM SEWERING, AND BUILDING
ENVELOPE LOCATIONS SHOULD BE MADE A PART OF THE CONSTRUCTION
PLANS. THESE AREAS ARE AS FOLLOWS:
A. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 6, PASSING
THROUGH THE CENTER OF LOT 10, CONTINUING ON THROUGH LOT 15
AND ULTIMATELY REACHING THE RPA, AFTER HAVING PASSED THROUGH
LOT 18.
B. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 36, PASSING
THROUGH LOT 39, BEFORE REACHING PEAKLAND DRIVE.
C. THE DRAINAGE CORRIDOR WHICH BEGINS IN LOT 59, PASSING
THROUGH THE CENTER OF LOT 62 BEFORE REACHING THE RPA.
****************************************