Thanksgiving Holiday Closings... MORE

Hover here for Site Tools
Subdivision Review Comments
All Subdivision Review Comments for Case # 12FC0011




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 12FC0011 STATUS: PENDING APPROVAL
PROJECT NAME: FOXCREEK - PHASE II - LAST INTERNET UPDATE: 11/21/17
SUBMITTAL TYPE: FINAL CHECK
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 12/29/11 01/19/12 COMPLETE 01/04/12 LAH 748-1945
ENVIR.ENGR.-: 00 12/29/11 01/19/12 ******** ********
FIRE DEPT.--: 00 12/29/11 01/19/12 COMPLETE 01/17/12 JKL 748-1489
HOUSE NUMBER: 00 12/29/11 01/19/12 ******** ********
MAPPING/GIS-: 00 12/29/11 01/19/12 COMPLETE 01/10/12 NCP 751-4319
PLANNING----: 00 12/29/11 01/19/12 COMPLETE 02/01/12 RHM 796-7193
SOILS-------: 00 12/29/11 01/19/12 ******** ********
TRANSPORT.--: 00 12/29/11 01/19/12 COMPLETE 01/18/12 JWS 748-1037
UTIL.PLAN.--: 00 12/29/11 01/19/12 COMPLETE 01/05/12 TVM 751-4435
UTILITIES---: 00 12/29/11 01/19/12 ******** ********
UTIL.R.O.W.-: 00 12/29/11 01/19/12 COMPLETE 01/18/12 KIP 748-1376
VDOT--------: 00 12/29/11 01/19/12 ******** ********
REVIEW DEPARTMENT : UTILITIES RIGHT OF WAY
REVIEWER : KIMBERLY PULLEY / 748-1376
NAME OF PLAN & NO. : WEXLEY @ FOXCREEK SEC 3/12FC0011
ADDRESS :
RECEIVED DATE : 12/30/11
PLAN/REVISION DATED: N/A
REVIEW DATE : 1/18/12
STATUS :
1. SIGN SURVEYORS SEAL
2. FILL IN DATES AND DB & PG FOR DECLARATION OF COVENANTS
3. LOT 9 - EASEMENT LABELED AS 'B' SHOULD BE 'A'
4. FILL IN DB & PG FOR EASEMENT LABELED AS 'D'
5. SUBDIVISION CERTIFICATE - TAKE OFF 'AND TRUSTEES' IF
THERE IS NO MORTGAGE ON THIS PROPERTY
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE # : TERRY MAPLES 751-4435
PLAN NAME: WEXLEY - SEC. 3 AT FOXCREEK
PLAN NUMBER: 12FC0011
ORIGINAL PLAN DATE: 12/15/11
REVIEW DATE: 01/05/12
LATEST SUBMISSION DATE:
SUBMITTAL NUMBER:
STATUS:
TABLE REVIEW
1. NO ADDITIONAL PUBLIC WATER AND SEWER EASEMENTS
ARE REQUIRED FOR THE ABOVE REFERENCED. (U)
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: WEXLEY SECTION 3 AT FOXCREEK
CASE NUMBER: 12FC0011
DEPT. REC'D. DATE: 01/04/12
SUBMITTAL NUMBER: ONE
REVIEW DATE: 01/18/12
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: YES
THE RIGHT OF WAY DEDICATION ALONG WOOLRIDGE ROAD SHOULD BE
45' MEASURED FROM THE CENTERLINE OF THE ROAD ADJACENT TO
THE PROPERTY.
============================================================
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : RUSS MILLS / 796-7193
PLAN NAME : WEXLEY AT FOXCREEK SECTION 3
PLAN NUMBER : 12FC0011
TENTATIVE NUMBER : 06TS0208
ORIGINAL PLAN DATE : N/A
REVIEW DATE : 12/30/2011
LATEST SUBMISSION DATE : 12/28/2011
SUBMITTAL NUMBER : 1
STATUS : PLANNING REVIEW COMPLETE
1. THE SUBDIVISION ID IS CORRECT. IT IS 016-0633-03
2. PLEASE ADD A NOTE THAT THE 50' BUFFER SHALL REMAIN IN A
NATURAL STATE AND REMAIN UNDISTURBED.
3. ON LOT 24, THE FRONT WOULD BE THE PROPERTY LINE FRONTING
BUGLERS TRAIL LANE, AND THE CORNERSIDE (BACK TO SIDE) WOULD
FRONT RAVENCHASE WAY. PLEASE FIX THE SETBACK LINES.
4. PROVIDE HOMEOWNERS ASSOCIATION (COVENANTS AND RESTRICTION
, BYLAWS, AND THE ARTICLES OF INCORPORATION) DB AND PG FOR
THE DOCUMENTS RECORDED WITH SECTION 1 OF WEXLEY. THESE MAY
USED FOR SECTION 3 AS WELL. YOU MAY OBTAIN THE RECORDED DB
AND PG FROM THE CIRCUIT COURTS RECORD ROOM.
5. FLAG/STAKE BUFFERS AND TREE PRESERVATION STRIP AND CALL
RUSS MILLS AT 796-7193 TO SCHEDULE AN INSPECTION. BUFFERS
MUST MEET STANDARDS OF 17-70 AND 19-518. IF BUFFER HAS BEEN
DAMAGED OR CLEARED, A LANDSCAPE PLAN AND BOND WILL BE
REQUIRED BEFORE RECORD PLAT SUBMITTAL.CALL FOR INSPECTION
AS SOON AS THE BUFFER IS FLAGGED/STAKED.
6. STANDARD CONDITIONS PER 17-43 OF THE SUBDIVISION
ORDINANCE.
7. PROVIDE ALL REQUIRED SIGNATURES, SIGN SEALS, UPDATE ALL
DATES.
8. NOTARIZE ALL SIGNATURES; PROVIDE NOTARY STAMPED SEALS ON
PLAT.
9. PLEASE BE SURE YOU HAVE ADDRESSED ALL REVIEW COMMENTS
FROM ALL REVIEWING DEPARTMENTS BEFORE SUBMITTING THE RECORD
PLAT TO PRECLUDE ANY UNNECCESSARY DELAYS.
10.WHEN ALL COMMENTS ADDRESSED FROM ALL REVIEWING
DEPARTMENTS SUBMIT 2 MYLAR COPIES AND 1 PAPER COPY OF THE
RECORD PLAT.
11. PLEASE NOTE THAT FINAL CHECK COMMENTS ARE VALID FOR 6
MONTHS AFTER THE LAST REQUIRED REVIEWING DEPARTMENT SUBMITS
COMMENTS, PER THE SUBDIVISION ORDINANCE 17-32 (E) (6).
***END OF REVIEW***
==========================================================
==========================================================
REVIEW DEPARTMENT: IST / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PROJECT : WEXLEY AT FOXCREEK SEC 3
PROJECT PLAN NO. : 12FC0011
ADDRESS :
LATEST PLAN DATE : 12/15/11
RECEIVED DATE : 12/28/11
SUBMITTAL NUMBER : 1
REVIEW DATE : 1/10/12
RECOMMENDATION : APPROVED
REVIEW DEPARTMENT: FIRE DEPARTMENT
REVIEWER / PHONE #: KIM LESTER / 804-748-1489
PLAN NAME: WEXLEY @ FOXCREEK
PLAN NUMBER: 12FC0011
PLAN RECEIVED DATE: 12/29/11
ORIGINAL PLAN DATE : 12/15/11
REVIEW DATE: 01/17/12
SUBMITTAL NUMBER: 1ST REVIEW
STATUS: APPROVED
TABLE REVEW:
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT :ASSESSORS
REVIEWER / PHONE # :LINDA HUMPHRIES / 748-1945
PLAN NAME :WEXLEY SECTION 3
PLAN NUMBER :12FC0011
ORIGINAL PLAN DATE :
REVIEW DATE :1/4/12
LATEST SUBMISSION DATE :
SUBMITTAL NUMBER :
STATUS :NO COMMENTS

Go to Case Selection Form or Go to Project List