Subdivision Review Comments
All Subdivision Review Comments for Case # 09TS0236




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 09TS0236 STATUS: PENDING APPROVAL
PROJECT NAME: DEBONAIRE ACRES - LAST INTERNET UPDATE: 11/20/17
SUBMITTAL TYPE: TENTATIVE SUBDIVISION
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 01 10/12/10 11/02/10 ******** ********
ENVIR.ENGR.-: 01 10/12/10 11/02/10 COMPLETE 10/26/10 LDP 748-1028
FIRE DEPT.--: 01 10/12/10 11/02/10 AMENDED* 11/03/10 JKL 748-1489
HOUSE NUMBER: 01 10/12/10 11/02/10 ******** ********
MAPPING/GIS-: 01 10/12/10 11/02/10 ******** ********
PLANNING----: 01 10/12/10 11/02/10 AMENDED* 11/03/10 RLC 748-1071
PARKS & REC.: 01 10/12/10 11/02/10 ******** ********
SCHOOL BOARD: 01 10/12/10 11/02/10 ******** ********
SOILS-------: 01 10/12/10 11/02/10 ******** ********
TRANSPORT.--: 01 10/12/10 11/02/10 COMPLETE 11/02/10 LWC 768-7386
UTIL.PLAN.--: 01 10/12/10 11/02/10 AMENDED* 10/25/10 TVM 751-4435
UTILITIES---: 01 10/12/10 11/02/10 ******** ********
UTIL.R.O.W.-: 01 10/12/10 11/02/10 ******** ********
VDOT--------: 01 10/12/10 11/02/10 ******** ********
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE # : TERRY MAPLES 751-4435
PLAN NAME: DEBONAIRE ACRES
PLAN NUMBER: 09TS0236
ORIGINAL PLAN DATE: 12/12/08
REVIEW DATE: 10/25/10
LATEST SUBMISSION DATE:10/01/10
SUBMITTAL NUMBER: 1
STATUS:
1. PRIOR TO TENTATIVE PLAN APPROVAL, THE UTILITIES DEPT.
WILL BE CONTACTING THE ENGINEER FOR THIS PROJECT TO
COME IN AND DISCUSS THE SIZE AND ROUTING OF THE WATER
LINES AND THE LOCATION OF THE PRESSURE ZONE BOUNDARY
(U)
2. A REVISED FIRE FLOW ANALYSIS MUST BE SUBMITTED TO THE
UTILITIES DEPT. FOR THE ENTIRE PROPOSED DEVELOPMENT
PRIOR TO TENTATIVE PLAN APPROVAL.
THE FIRE FLOW ANALYSIS SHALL INCLUDE A SCHEMATIC PLAN
LAYOUT SHOWING ALL WATER LINE SIZES AND LENGTHS,
NODE ELEVATIONS AND FIRE FLOW ANALYSIS AT ALL PROPOSED
FIRE HYDRANTS. A C-FACTOR OF 120 SHALL
3. PER ZONING CASE 07SN0342, AN OVERALL WATER
LINE PLAN FOR THE ENTIRE DEVELOPMENT FOR
REVIEW AND APPROVAL BY THE UTILITIES
DEPT. THE OVERALL WATER SYSTEM PLAN SHALL
BE ACCOMPANIED BY A WATER SYSTEM PHASING
PLAN DEPICTING THE CONSTRUCTION PHASING FOR
ALL NEW WATER INFRASTRUCTURE RELATED TO THIS
DEVELOPMENT. (U)
REVIEW DEPARTMENT: TRANSPORTATION
REVIEWER/PHONE #: LOUIS CORDE / 768-7386
PLAN NAME: DEBONAIRE ACRES
PLAN NUMBER: 09TS0236
ORIGINAL PLAN DATE: 12/12/08
REVIEW DATE: 01/09/09 12/19/08
LATEST SUBMISSION DATE: 12/15/08
SUBMITTAL NUMBER: 1
STATUS: NOT APPROVED, CORRECTIONS REQUIRED
THE TRANSPORTATION DEPARTMENT HAS THE FOLLOWING COMMENTS:
THE DEBONAIR DRIVE AND CLUBHOUSE TURN LANE LOOP SHALL BE
DESIGNED AS A NO LOT FRONTAGE ROADWAY AND SIDEWALK SHALL BE
CONSTRUCTED ON BOTH SIDES OF THE LOOP FOR THE ENTIRE LENGTH.
(T)
SPITE STRIPS SHOULD BE REMOVED FROM THE LAYOUT IN THE
VICINITY OF LOTS 2&3 AND IN THE VICINITY OF LOTS 113 THRU
110. (T)
STUBS SHOULD BE ADDED FOR FUTURE DEVELOPMENT ON OR
ADJACENT TO LOTS 138,137,109,88,27,18,8,5,219,215,214
AND AS AN EXTENSION OF SKIP AWAY TERRACE. (T)
PLEASE SHOW A DESIGN VOLUME OF 4,000 VPD ON GRAVES ROAD. (T)
PLEASE NOTE PROFFERED CONDITIONS OF ZONING RELATIVE TO
REQUIRED ROAD IMPROVEMENTS AND DEDICATION OF RIGHT-OF-WAY.
(T)
============================================================
REVIEW DEPARTMENT: CHESTERFIELD TRANSPORTATION DEPARTMENT
REVIEWER/PHONE#: JESSE W. SMITH, P.E. (804)748-1998
NAME OF PLAN: DEBONAIR ACRES
CASE NUMBER: 09TS0236
LATEST PLAN DATE: 10/01/10
DEPT. REC'D. DATE: 10/12/10
SUBMITTAL NUMBER: TWO
REVIEW DATE: 11/02/10
RECOMMENDATION: NOT APPROVED
TABLE REVIEW: NO
1. PROVIDE TRAFFIC PROJECTIONS FOR EACH ROAD SEGMENT SHOWN
ON THE PLAT. INCLUDE TRAFFIC FROM ADJACENT STUBS AND
PROVIDE AN ANALYSIS WITH HOW THE NUMBERS WERE DERIVED.
2. STUB ROADS MUST BE PROVIDED TO ALL ADJACENT PROPERTIES,
INCLUDING BUT NOT LIMITED TO: HAWKINS, EANES, PERKINSON,
REED, AND BAUGH.
3. ANY ROADS ANTICIPATED TO EXCEED THE VOLUME ESTABLISHED
IN THE PLANNING COMMISSION'S STUB ROAD POLICY MUST BE
DESIGNED AS NO-LOT-FRONTAGE ROADWAYS WITH SIDEWALK ALONG
BOTH SIDES.
4. RIGHT AND LEFT TURN LANES SHALL BE PROVIDED AT EACH
PROPOSED PUBLIC ROAD INTERSECTION ON GRAVES ROAD. THE
DEVELOPER SHALL DEDICATE ANY ADDITIONAL RIGHT OF WAY
REQUIRED FOR THESE IMPROVEMENTS.
============================================================
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : RAY CASH / 748-1071
PLAN NAME : DEBONAIR ACRES
PLAN NUMBER : 09TS0236
ORIGINAL PLAN DATE : 12/12/08
REVIEW DATE : 1/05/08
LATEST SUBMISSION DATE : 12/15/08
SUBMITTAL NUMBER : 1
STATUS : REVISIONS REQUESTED
PRIOR TO RESUBMITTAL ENSURE ALL REVIEWING DEPARTMENTS
COMMENTS HAVE BEEN RECIEVED AND ADDRESSED. PROVIDE
WITH EACH SUBMITTAL A LETTER THAT INCLUDES EACH COMMENT
AND STATES HOW IT WAS ADDRESSED. DETAIL ANY CHANGES THAT
WERE MADE TO THE PLAT THAT WERE NOT RESULT OF REVIEW
COMMENTS.
1. PROVIDE DETAILED PLAN SHEET AND REQUIRED CALCULATIONS
AS PER ORDINANCE 19-69. LOT SIZES, TOTAL NUMBER OF LOTS
AND BONUS LOTS SUBJECT TO ORDINANCE REQUIRED CALCULATIONS
AND MAY NEED TO BE REVISED ONCE PROVIDED.
2. NO MORE THAN FIFTY LOTS MAY BE RECORDED PRIOR TO
CONSTRUCTION OF SECOND ACCESS AS PER 17-76.
3. STUB ROADS APPEAR TO BE REQUIRED AT THE FOLLOWING
LOCATIONS. ADDITIONAL STUBS MAY BE REQUIRED PER THE
STUB ROAD POLICY AND THE CONNECTIVITY POLICY. EXACT
LOCATIONS AND NUMBER OF CONNECTIONS MAY VARY AS
DETERMINED BY CDOT AND PLANNING:
GPIN 7606157583,7596169523,7606175175,7636192919,7706200238,
7716205833, 7696152891, 7686156400, 7646151922, 7646157374,
7656156298, 7706188847, 7716170374, 7706177356, 7706177614,
7706166126, 7706164384
4. VERIFY AND CLEARLY MARK/LABEL PROPERTY LINE WITH GPIN
7676147583 AND 7676145600. PREVIOUSLY RECORDED PLATS SEEM
TO DIFFER FROM SHOWN.
5. GPIN 7646168303 WAS NOT INCLUDED IN APPLICATION AND
IS NOT SHOWN AS PART OF THIS TENTATIVE. PARCEL WAS PART OF
THIS TENTATIVE. AMEND PLAT AND APPLICATION.
6. THERE APPEARS TO BE EXISTING ACCESS VIA 7646168303 TO
ADJACENT PARCELS. DETAIL.
7. LABEL AND SHOW ZONING BOUNDARIES ON PROPERTY AND
ZONING OF ADJACENT PROPERTIES.
8. LABEL CONTOURS PER 17-38 (D) (9).
9. LABEL ALL OPEN SPACE AND LABEL ANY PROPOSED USES.
CLEARLY DEFINE BOUNDARIES AND PROVIDE SIZE OF EACH OPEN
SPACE.
10. PROVIDE NOTE AS PER 17-38 (C) (8)
11.SHOW ANY RESIDENTIAL STOCK FARM USES. CLUBHOUSE NOT
AN ACCEPTABLE USE UNDER THIS ZONING. SHOWN TRACK MAY
NOT BE AN ACCEPTABLE USE. PROVIDE DETAIL ON WHAT USES ARE
PROPOSED FOR SITE.
12. SHOW ALL PROPOSED HORSE TRAILS ON PLAT.
13. AREA OF PROPOSED STOCK FARM USE WOULD REQUIRE SITE PLAN
APPROVAL AS PER ORDINANCE AND ZONING REQUIREMENTS.
14. SIDEWALKS WOULD BE REQUIRED AT A MINIMUM ALONG BOTH
SIDES OF PROPOSED DEBONAIR DRIVE AND CLUBHOUSE TURN
LANE PER CPC SIDEWALK POLICY AND OTHER LOCATIONS AS PER CDOT
DETERMINATION.
15. CLEARLY LABEL LIMITS OF TENTATIVE. NOT CLEAR IN SOME
LOCATIONS.
16. REVISE PLAT TO SHOW CEMETERY/GRAVE LOCATIONS AND
ACCESSES TO CEMETERY/GRAVE LOCATIONS. REVISE
INVESTIGATION SHEET FOR GRAVES, ETC. PROVIDED WITH
APPLICATION PACKET.
17. PROVIDE BUFFER ALONG DEBONAIR DRIVE AND CLUBHOUSE
TURN LANE AS REQUIRED.
18. ANY CHANGE IN THE CURRENT PLAN, WHETHER IT STEMS FROM
DEPARTMENT COMMENTS OR AN ENGINEERING CHANGE REQUESTED
BY THE APPLICANT, MAY GENERATE ADDITIONAL COMMENTS FROM
REVIEWING DEPARTMENTS RESULTING IN REQUIRED REVISIONS.
19. STANDARD CONDITIONS (SECTION 17-62)
20. IN CONJUNCTION WITH THE SUBMITTAL OF THE FINAL CHECK
PLATS, THE SUBDIVIDER SHALL FLAG ALL BUFFERS FOR INSPECTION
BY THE PLANNING DEPARTMENT. IF INSUFFICIENT VEGETATION
REMAINS, THE SUBDIVIDER SHALL SUBMIT A LANDSCAPE PLAN TO
THE DIRECTOR OF PLANNING TO ENSURE COMPLIANCE WITH THIS
CONDITION. IF CONDITIONS ON SITE ARE NOT CONDUCIVE TO PLANT
SURVIVAL, THE SUBDIVIDER SHALL PROVIDE SURETY TO THE COUNTY
IN THE AMOUNT REQUIRED TO IMPLEMENT THE PLAN. AN ESTIMATE
FROM A LANDSCAPE CONTRACTOR SHALL SERVE AS THE BASIS FOR
THE SURETY AMOUNT. ALL BUFFERS SHALL COMPLY WITH SECTION
17-70.
21. LOTS FRONTING ON THE BULBS OF CUL-DE-SACS SHALL BE
DESIGNED SO THAT BUILDING LINES ARE UNIFORM AROUND THE BULB.
22. PLACE A NOTE ON THE FINAL CHECK AND RECORD PLAT STATING
THE BUFFER IS EXCLUSIVE OF EASEMENTS AND YARD REQUIREMENTS
23. IN CONJUNCTION WITH ALL APPLICABLE ROAD CONSTRUCTION,
THE SUBDIVIDER SHALL INSTALL A STANDARD BARRICADE AND
PLACE M 4-6 AND M 4-7 (MANUAL UNIFORM TRAFFIC DEVICES
REFERENCE MANUAL) SIGNS ON SAID BARRICADE AT THE END
OF ALL STUB LOCATIONS. PROVIDE A DETAIL OF THE SIGNS
ON THE BARRICADE DETAIL IN THE CONSTRUCTION PLANS.
24. HOMEOWNERS ASSOCIATION WITH MANDATORY MEMBERSHIP WILL
WILL BE REQUIRED. OWNERSHIP AND MAINTENANCE
RESPONSIBILITIES OF THE ASSOCIATION SHALL BE STATED ON ALL
FINAL CHECK AND RECORD PLATS. THE SUBDIVIDER SHALL SUBMIT
DRAFT BYLAWS AND COVENANTS OF THE ASSOCIATION TO THE
PLANNING DEPARTMENT AND COUNTY ATTORNEY'S OFFICE IN
CONJUNCTION WITH THE FINAL CHECK PLAT. THE SUBDIVIDER SHALL
ALSO INCORPORATE THE ASSOCIATION WITH THE STATE
CORPORATION COMMISSION. THE APPROVED BYLAWS AND COVENANTS
SHALL BE RECORDED PRIOR TO OR IN CONJUNCTION WITH THE RECORD
PLAT. THE RECORDATION INFORMATION SHALL BE SHOWN ON THE
RECORD PLAT AND EACH SUBSEQUENT FINAL CHECK AND RECORD PLAT.
THE SUBDIVIDER SHALL FUND THE FIRST YEAR OPERATIONAL EXPENSE
OF THE ASSOCIATION. (SEC. 19-559)
25. INSERT THE TENTATIVE CASE NUMBER IN THE SITE STATISTICS
NOTE ON THE CONSTRUCTION PLANS.
26. ON THE CONSTRUCTION PLANS, IN THE EROSION CONTROL
NARRATIVE, INSERT THE PROVISIONS FOR THE INSTALLATION OF
TREE PROTECTION FENCING OR TREE PROTECTION TAPE TO
PROTECT THE REQUIRED BUFFERS.
27. AT TIME OF FINAL CHECK, PLEASE SUBMIT THE HEALTH
DEPARTMENT REVIEW FEE FOR THE SEPTIC SYSTEMS TO BE
UTILIZED ON EACH LOT.
PLEASE NOTE THAT DUE TO THE INSUFFICIENT INFORMATION
SUBMITTED WITH THE TENTATIVE PLAN THAT A COMPLETE REVIEW
OF THE PLAN IS NOT POSSIBLE. FUTURE REVIEWS OF THE PLAN
MAY GENERATE NEW REVIEW COMMENTS AND REVISIONS.
END REVIEW
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : RAY CASH / 748-1071
PLAN NAME : DEBONAIR ACRES
PLAN NUMBER : 09TS0236
ORIGINAL PLAN DATE : 12/12/08
REVIEW DATE : 11/2/10
LATEST SUBMISSION DATE : 10/08/10 (10/1/10 REV DATE)
SUBMITTAL NUMBER : 2
STATUS : REVISIONS REQUESTED
PRIOR TO RESUBMITTAL ENSURE ALL REVIEWING DEPARTMENTS
COMMENTS HAVE BEEN RECIEVED AND ADDRESSED. PROVIDE
WITH EACH SUBMITTAL A LETTER THAT INCLUDES EACH COMMENT
AND STATES HOW IT WAS ADDRESSED. DETAIL ANY CHANGES THAT
WERE MADE TO THE PLAT THAT WERE NOT RESULT OF REVIEW
COMMENTS.
1. PROVIDE DETAILED PLAN SHEET AND REQUIRED CALCULATIONS
AS PER ORDINANCE 19-69. LOT SIZES, TOTAL NUMBER OF LOTS
AND BONUS LOTS SUBJECT TO ORDINANCE REQUIRED CALCULATIONS
AND MAY NEED TO BE REVISED ONCE PROVIDED. CURRENT SUBMITTAL
PROVIDES ACERAGE IN CHART AND ON PLAT MAP THAT DO NOT MATCH.
CALCULATIONS AS PROVIDE IN CHART DO NOT CALCULATE CORRECTLY.
IN ADDITION NUMBERS DO NOT MATCH PROVIDED NUMBERS ON SHEET 1
2. PROPERTY PROPOSED TO BE PROVIDED TO COUNTY IN PERPETUAL
EASEMENT MUST MEET APPROVAL OF SITE SELECTION COMMITTEE
PRIOR TO TENTATIVE APPOVAL. THIS AFFECTS BONUS LOT
CALCULATIONS UNDER 19-69 (10). UNTIL SUCH TIME BONUS LOTS
MAY NOT BE APPROVED.
3. NUMBER OF LOTS. LOT AND AREA SIZE CALCULATIONS UNDER NOTE
AREA OF SHEET 1 NEED TO BE REVISED.
4. STUBS NEED TO BE PROVIDED PER PREVIOUS REVIEW COMMENTS.
STILL NEED FOR GPINS 7646151922, 7646157374, 7686156400,
7696152891, 7706188847, 7716170374, 7706177356, 7706177614,
7706166126, 7706164384, 7686185363,7656156298
5. UNCLEAR WHAT HEAVY DARK LINE IS ON PLAT MAP AS IT IS
INSIDE OF BOUNDRY AND COVERS GOOD PORTION OF DEVELOPMENT,
LABEL LINES. LINE ALSO OBSCURES MEASUREMENTS ADJUST.
6. LABEL TENTATIVE BOUNDARIES.
7. LABEL AND SHOW ZONING CASE LINE.
8. PROVIDE SIDEWALKS AS PER CPC SIDEWALK POLICY ALONG GRAVES
ROAD. PROVIDE SIDEWALKS PER CPC POLICY SHOULD ANY ROAD
MEET CRITERIA.
9. NO MORE THAN FIFTY LOTS MAY BE RECORDED PRIOR TO
CONSTRUCTION OF SECOND ACCESS AS PER 17-76.
10. IT IS UNCLEAR THE AMOUNT OF SEPARATION BETWEEN PHOTO
FINISH TERRACE AND ADJACENT PROPERTY LINE. PROVIDE ON PLAT.
11. THIS SUBMITTAL DOES NOT SHOW ANY PROPOSE EQUESTRIAN USES
OR FACILITIES. SHOULD ANY BE PROPOSED AT A MINIMUM
TENTATIVE PLAT AND SITE PLAN WOULD BE REQUIRED. SHOW ANY
PROPOSED PEDESTRIAN OF EQUESTIAN TRAILS ON PLANS AS WELL.
12. THERE APPEARS TO BE A CHOKE POINT AT PACE SETTER DR
AND DEBONAIR DRIVE THAT DOES NOT MEET SEC. 17-76.
13. SHOULD ROAD CLASSIFICATIONS BE CHANGED BUFFERS MAY
BE REQUIRED BASED UPON CLASSIFICATION PER SEC. 17-70.
14. GPIN 7646168303 IS PART OF TENTATIVE BUT DOES NOT APPEAR
TO BE DESIGNATED FOR ANY USE OR WITHIN LABELED BOUNDARY.
REVISE AND LABEL APPROPIATELY.
15. ANY CHANGE IN THE CURRENT PLAN, WHETHER IT STEMS FROM
DEPARTMENT COMMENTS OR AN ENGINEERING CHANGE REQUESTED
BY THE APPLICANT, MAY GENERATE ADDITIONAL COMMENTS FROM
REVIEWING DEPARTMENTS RESULTING IN REQUIRED REVISIONS.
16. STANDARD CONDITIONS (SECTION 17-62)
17. IN CONJUNCTION WITH THE SUBMITTAL OF THE FINAL CHECK
PLATS, THE SUBDIVIDER SHALL FLAG ALL BUFFERS FOR INSPECTION
BY THE PLANNING DEPARTMENT. IF INSUFFICIENT VEGETATION
REMAINS, THE SUBDIVIDER SHALL SUBMIT A LANDSCAPE PLAN TO
THE DIRECTOR OF PLANNING TO ENSURE COMPLIANCE WITH THIS
CONDITION. IF CONDITIONS ON SITE ARE NOT CONDUCIVE TO PLANT
SURVIVAL, THE SUBDIVIDER SHALL PROVIDE SURETY TO THE COUNTY
IN THE AMOUNT REQUIRED TO IMPLEMENT THE PLAN. AN ESTIMATE
FROM A LANDSCAPE CONTRACTOR SHALL SERVE AS THE BASIS FOR
THE SURETY AMOUNT. ALL BUFFERS SHALL COMPLY WITH SECTION
17-70.
18.LOTS FRONTING ON THE BULBS OF CUL-DE-SACS SHALL BE
DESIGNED SO THAT BUILDING LINES ARE UNIFORM AROUND THE BULB.
19. PLACE A NOTE ON THE FINAL CHECK AND RECORD PLAT STATING
THE BUFFER IS EXCLUSIVE OF EASEMENTS AND YARD REQUIREMENTS
20. IN CONJUNCTION WITH ALL APPLICABLE ROAD CONSTRUCTION,
THE SUBDIVIDER SHALL INSTALL A STANDARD BARRICADE AND
PLACE M 4-6 AND M 4-7 (MANUAL UNIFORM TRAFFIC DEVICES
REFERENCE MANUAL) SIGNS ON SAID BARRICADE AT THE END
OF ALL STUB LOCATIONS. PROVIDE A DETAIL OF THE SIGNS
ON THE BARRICADE DETAIL IN THE CONSTRUCTION PLANS.
21. HOMEOWNERS ASSOCIATION WITH MANDATORY MEMBERSHIP WILL
WILL BE REQUIRED. OWNERSHIP AND MAINTENANCE
RESPONSIBILITIES OF THE ASSOCIATION SHALL BE STATED ON ALL
FINAL CHECK AND RECORD PLATS. THE SUBDIVIDER SHALL SUBMIT
DRAFT BYLAWS AND COVENANTS OF THE ASSOCIATION TO THE
PLANNING DEPARTMENT AND COUNTY ATTORNEY'S OFFICE IN
CONJUNCTION WITH THE FINAL CHECK PLAT. THE SUBDIVIDER SHALL
ALSO INCORPORATE THE ASSOCIATION WITH THE STATE
CORPORATION COMMISSION. THE APPROVED BYLAWS AND COVENANTS
SHALL BE RECORDED PRIOR TO OR IN CONJUNCTION WITH THE RECORD
PLAT. THE RECORDATION INFORMATION SHALL BE SHOWN ON THE
RECORD PLAT AND EACH SUBSEQUENT FINAL CHECK AND RECORD PLAT.
THE SUBDIVIDER SHALL FUND THE FIRST YEAR OPERATIONAL EXPENSE
OF THE ASSOCIATION. (SEC. 19-559)
22. INSERT THE TENTATIVE CASE NUMBER IN THE SITE STATISTICS
NOTE ON THE CONSTRUCTION PLANS.
23. ON THE CONSTRUCTION PLANS, IN THE EROSION CONTROL
NARRATIVE, INSERT THE PROVISIONS FOR THE INSTALLATION OF
TREE PROTECTION FENCING OR TREE PROTECTION TAPE TO
PROTECT THE REQUIRED BUFFERS.
24. AT TIME OF FINAL CHECK, PLEASE SUBMIT THE HEALTH
DEPARTMENT REVIEW FEE FOR THE SEPTIC SYSTEMS TO BE
UTILIZED ON EACH LOT.
PLEASE NOTE THAT DUE TO THE INSUFFICIENT INFORMATION
SUBMITTED WITH THE TENTATIVE PLAN THAT A COMPLETE REVIEW
OF THE PLAN IS NOT POSSIBLE. FUTURE REVIEWS OF THE PLAN
REVIEW DEPARTMENT: FIRE DEPARTMENT
REVIEWER / PHONE#: KIM LESTER, 748-1489
NAME OF PLAN: DEBONAIRE ACRES
SUBDIVISION PLAN NUMBER: 09TS0236
LATEST PLAN DATE: 12/12/08
DEPARTMENT RECEIVED DATE: 12/18/09
SUBMITTAL NUMBER: 1ST REVIEW
REVIEW DATE: 01/13/09
COMMENTS:
A SECOND STREET, PROVIDING ACCESS TO ALL LOTS, SHALL
BE CONSTRUCTED PRIOR TO, OR IN CONJUNCTION WITH, THE
RECORDATION OF THE FIFTY-FIRST LOT.
THE MINIMUM TURNING RADIUS TO BE PROVIDED FOR THE
EMERGENCY FIRE APPARATUS TO TRAVEL, INCLUDING CUL-DE-SACS,
SHALL BE AT LEAST 42' (OUTSIDE).
THE APPLICANT DOES NOT SHOW ANY CONNECTIONS TO THE
ADJACENT PROPERTY THAT CAN BE DEVELOPMENT. THE FIRE
DEPARTMENT CONTINUES TO SUPPORT CONNECTIVITY BETWEEN
SUBDIVISIONS SO THAT MULTIPLE ACCESS POINTS ARE AVAILABLE
TO ASSIST IN AN EMERGENCY RESPONSE. PLEASE SHOW THE
CONNECTIONS THAT THE PROPERTY AFFECTS.
NOTE: NOTE: HYDRANT REQUIREMENTS AND LOCATIONS SHOWN
ON THE TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S)
REQUIRED AND THEIR LOCATION WILL BE EVALUATED AT THE TIME OF
CONSTRUCTION PLAN REVIEW.
WHEN SUBMITTING THE CONSTRUCTION PLANS, PROVIDE AN
ADDITIONAL COPY TO GO TO THE FIRE DEPARTMENT FOR REVIEW.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
REVIEW DEPARTMENT: FIRE DEPARTMENT
REVIEWER / PHONE#: KIM LESTER, 748-1489
NAME OF PLAN: DEBONAIRE ACRES
SUBDIVISION PLAN NUMBER: 09TS0236
LATEST PLAN DATE10/01/10
DEPARTMENT RECEIVED DATE: 10/12/10
SUBMITTAL NUMBER: 2ND REVIEW
REVIEW DATE: 11/03/10
COMMENTS:
THERE'S A CHOKE POINT OF 68 LOTS COMING AT THE
INTERSECTION OF PACE SETTLERS DRIVE AND DEBONAIR
DRIVE.
A SECOND STREET, PROVIDING ACCESS TO ALL LOTS, SHALL
BE CONSTRUCTED PRIOR TO, OR IN CONJUNCTION WITH, THE
RECORDATION OF THE FIFTY-FIRST LOT.
DEAD-END FIRE APPARTUS ACCESS ROADS IN EXCESS OF 150'
IN LENGTH SHALL BE PROVIDED WITH AN APPROVED AREA FOR
TURNING AROUND FIRE APPARATUS. IN ACCORDANCE WITH TABLE
D103.4. THE STUB ROAD THAT IS SHOWN BY LOT 1 IS LONGER
THAN 150' A TURN AROUND NEEDS TO BE PROVIDED AT THE
END OF THE STUB ROAD TOWARDS THE PRIOR PROPERTY.
IFC 2006,503.2.5
THE CUL-DE-SAC BY LOT 111 ON DEBONAIR DRIVE NEEDS
TO BE PUSH BACK TO THE ADJACENT PARCEL.
CONDITIONS:
THE APPLICANT DOES NOT SHOW ANY CONNECTIONS TO THE
ADJACENT PROPERTY THAT CAN BE DEVELOPMENT. THE FIRE
DEPARTMENT CONTINUES TO SUPPORT CONNECTIVITY BETWEEN
SUBDIVISIONS SO THAT MULTIPLE ACCESS POINTS ARE AVAILABLE
TO ASSIST IN AN EMERGENCY RESPONSE. PLEASE SHOW THE
CONNECTIONS THAT THE PROPERTY AFFECTS.
FIRE APPARTUS ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED
WIDTH OF NOT LESS THAN 20 FEET EXCLUSIVE OF SHOULDERS.
IFC 2006, 503.2.1
NOTE: HYDRANT REQUIREMENTS AND LOCATIONS SHOWN
ON THE TENTATIVE PLAN MAY NOT BE ACCEPTABLE. HYDRANT(S)
REQUIRED AND THEIR LOCATION WILL BE EVALUATED AT THE TIME OF
CONSTRUCTION PLAN REVIEW.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
PLAN NAME: DEBONAIR ACRES
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: L. D. PRITCHARD, JR. / 748-1028
PLAN NUMBER: 09TS0236
ORIGINAL PLAN DATE: DECEMBER 12, 008
LATEST SUBMISSION DATE: DECEMBER 12, 2008
REVIEW DATE: MAY 6, 2009
SUBMITTAL NUMBER: 1
STATUS: REVISIONS REQUESTED
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS
THE FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS
PERTAINING TO THE ABOVE REFERENCED TENTATIVE PLAT DATED
DECEMBER 12, 2008, RECEIVED BY THE PLANNING
DEPARTMENT ON DECEMBER 15, 2008 AND BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT ON DECEMBER 18,
2008.
WITH RESPECT TO ROAD NAMES, THE RRPDC STREET NAME
CLEARING HOUSE REQUEST SHEET WAS SUBMITTED WITHOUT FIRST
HAVING IT SUBMITTED TO RRPDC FOR THEIR APPROVAL. THE
SECTION OF THE CLEARING HOUSE REQUEST SHEET UNDER "RRPDC
USE ONLY" IS BLANK. PLEASE HAVE THE TWO SHEETS SENT TO
RRPDC FOR THEIR APPROVAL AND RE-SUBMIT TO THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. PHOTO FINISH
PLACE AND PHOTO FINISH COURT SHOULD BE ONE NAME OF PHOTO
FINISH TERRACE.
PLEASE PROVIDE A COPY OF THE OFFICE OF WATER QUALITY'S
CONFIRMATION OF THE PERENNIALITY SO THAT THE EXTENT TO
WHICH THE RPAS ARE SHOWN ON THE TENTATIVE PLAT CAN BE
CORRELATED WITH WHAT HAS BEEN CONFIRMED TO BE PERENNIAL
STREAMS.
PLEASE PROVIDE ON THE TENTATIVE PLAT THE SPECIFIC NAME
OF THE INDIVIDUAL WHO PERFORMED THE WETLANDS DELINEATION
SO THAT IT MAY BE CONFIRMED THAT HE OR SHE IS ON THE
APPROVED WETLANDS DELINEATOR LIST AND INDICATE THE STATUS
OF CONFIRMATION OF THE WETLANDS BY THE U.S. ARMY CORPS
OF ENGINEERS.
PLEASE PROVIDE A LETTER FROM THE RECOGNIZED WETLAND
EXPERT REGARDING THE ACCURACY OF THE WETLANDS DELINEATION
PORTRAYED ON THE TENTATIVE PLAT THAT IS THE BASIS FOR THE
RPA-LIMITS ESTABLISHMENT. SUGGESTED WORDING IS, "I HAVE
VIEWED THE TENTATIVE PLAT FOR DEBONAIR ACRES DATED
DECEMBER 12, 2008 BY HIGHMARK ENGINEERING AND FIND THAT
IT PORTRAYS AN ACCURATE REPRESENTATION OF MY FIELD
DELINEATION OF THE WETLANDS LOCATED ADJACENT TO THE PERENNIA
STREAMS.
IN ORDER TO ENSURE THE ACCURACY OF THE RPA ESTABLISHMENT,
THE COORDINATE POINTS WHICH CAPTURE THE POINT OF PERENNIAL
FLOW MUST BE SHOWN ON THE TENTATIVE PLAT. IF THE WETLANDS
UPSTREAM OF THE POINT OF PERENNIALITY ARE CONFINED TO WITHIN
A BED AND BANK BECOMING "WATERS OF THE U.S.", THE LIMITS OF
THE RPA AS THEY EXTEND UPSTREAM FROM THE POINT OF
PERENNIALITY ARE ESTABLISHED BY A 100 FOOT RADIUS BUFFER OFF
OF THAT POINT OF PERENNIAL FLOW. IF FROM THAT POINT OF
PERENNIAL FLOW, WETLANDS EXTEND ON UPSTREAM THAT ARE
CONNECTED AND CONTIGUOUS, THE RPA WOULD EXTEND A
DISTANCE NO GREATER THAN 500' IN ACCORDANCE WITH THE
ENVIRONMENTAL ENGINEERING POLICY OF APRIL 30, 2008.
BASED ON THE ABOVE DISCUSSION, THERE MAY NEED TO BE AN
EXTENSION OF THE RPA PRESENTLY TERMINATING IN LOT 102 INTO
LOT 97. PLEASE ADDRESS. IF THE COORDINATE POINTS NORTH AND
EAST VALUES ARE NOT PRESENTLY IN YOUR POSSESSION, PLEASE
CONTACT SCOTT WILLIAMS OF THE OFFICE OF WATER QUALITY IN THE
ENVIRONMENTAL ENGINEERING DEPARTMENT AT 768-7805.
FOR THOSE RPAS WHICH ARE VALIDLY CONSISTENT WITH THE
ENVIRONMENTAL ENGINEERING POLICY OF APRIL 30, 2008, PLEASE
SHOW THE ANNOTATED 500 FOOT DISTANCE BETWEEN THE PERENNIAL
STREAM AND THE TERMINUS OF THE RPA.
AN ASSESSMENT OF THE TOPOGRAPHY IN RELATION TO THE LOT
LAYOUT HAS REVEALED SEVERAL AREAS OF STORM WATER
CONCENTRATION WHICH ARE IN POTENTIAL CONFLICT WITH THE
DESIRE NOT TO HAVE STORM DRAINAGE PROBLEMS RELATED TO THE
DEVELOPMENT OF THE HOUSE AND LOT. THESE ARE ENGINEERING
ISSUES WHICH SHOULD BE ADDRESSED BY THE CONSTRUCTION
PLANS AND NOT LEFT TO THE INDIVIDUAL BUILDERS TO DEAL WITH.
THE PHYSICAL "LOW" OF THESE DRAINAGE CORRIDORS SHOULD BE
FIELD LOCATED AND APPROPRIATE ENGINEERING PROPOSALS WITH
RESPECT TO FILLING, GRADING, DRAINAGE STORM SEWERING AND
BUILDING ENVELOPE LOCATIONS SHOULD BE MADE A PART OF THE
CONSTRUCTION PLANS. THESE AREAS ARE AS FOLLOWS:
A. THE DRAINAGE CORRIDOR BETWEEN LOTS 232 AND 236.
B. THE DRAINAGE CORRIDOR BEGINNING IN LOT 179 DOWN TO
LOT 170.
C. THE DRAINAGE CORRIDOR BEGINNING IN LOT 54 DOWN
THROUGH LOT 47.
D. THE DRAINAGE CORRIDOR BEGINNING IN LOT 32, DOWN
THROUGH LOT 35.
PRIOR TO APPROVAL OF THE DEBONAIR ACRES TENTATIVE, THE
DEVELOPER WILL SUBMIT A LETTER OF ACKNOWLEDGEMENT OF THE
CONDITION REGARDING MASONRY EMBELLISHMENTS WITHIN THE
VDOT CLEAR ZONE. THIS ACKNOWLEDGEMENT IS THE
RESPONSIBILITY OF THE DEVELOPER AND NOT HIS REPRESENTATIVE A
HE IS ULTIMATELY RESPONSIBLE FOR REMOVAL OF HEADWALLS IN ALL
NEW SUBDIVISIONS SHOULD IT BECOME NECESSARY. A DRAFT OF
THAT LETTER IS ENCLOSED FOR YOUR CONVENIENCE.
TENTATIVE CONDITIONS COULD INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
1. PER SECTION 8-4 OF THE EROSION CONTROL ORDINANCE, PRIOR
TO THE ISSUANCE OF A LAND DISTURBANCE PERMIT, THE
ENVIRONMENTAL ENGINEERING DEPARTMENT SHALL REQUIRE
COPIES OF APPLICABLE CORRESPONDENCE FROM THE USACOE SO
THAT IT MAY BE DETERMINED THAT ALL WETLANDS PERMITS HAVE
BEEN RECEIVED.
2. ANY TIMBERING THAT IS TO OCCUR AS THE FIRST PHASE OF
INFRASTRUCTURE CONSTRUCTION WILL BE INCORPORATED INTO THE
PROJECT'S EROSION-AND-SEDIMENT CONTROL PLAN NARRATIVE AND
WILL NOT COMMENCE UNTIL THE ISSUANCE OF A LAND DISTURBANCE
PERMIT FOR SUBDIVISION CONSTRUCTION AND PROPER INSTALLATION
OF EROSION CONTROL MEASURES.
3. THE USACOE JURISDICTIONAL WETLANDS SHALL BE SHOWN
ON THE CONSTRUCTION PLANS AND SUBDIVISION PLAT
4. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE APPLICANT WILL
PROVIDE THE ENVIRONMENTAL ENGINEERING DEPARTMENT
INFORMATION CONFIRMING THAT THERE WILL BE NO ENCROACHMENT
OF THE PRIMARY OR SECONDARY DRAIN FIELDS OR HOME
CONSTRUCTION INTO THE RPA. THIS WILL BE DOCUMENTED BY
THE INCLUSION OF A PLAN VIEW SHEET IN THE CONSTRUCTION PLANS
5. THE AREAS OF STORM-WATER RUNOFF CONCENTRATION AS
DISCUSSED IN THE ENVIRONMENTAL ENGINEERING DEPARTMENT
TENTATIVE REPORT DATED MAY 6, 2009 WILL BE FIELD LOCATED
AND SHOWN ON THE PLANS. THE CONSTRUCTION PLANS SHALL
DESIGNATE THE AFFECTED LOTS WITH AN NBP, AND AN
ENGINEERED STORM SEWER, FILLING, GRADING, AND DRAINAGE
PLAN SHALL BE INCLUDED IN THE CONSTRUCTION PLANS.
6. THE SUB-DIVIDER SHALL POST SIGNS DEMARKING THE LIMITS
OF THE RPA AREA SO BUILDERS AND HOMEOWNERS MAY BE
INFORMED AS TO THE LIMITATIONS IMPOSED ON THESE AREAS.
SPECIFIC PLANS FOR THE EXACT NUMBER AND PLACEMENT OF THE
SIGNS SHALL BE APPROVED BY THE ENVIRONMENTAL ENGINEERING
DEPARTMENT.
7. THE EROSION AND SEDIMENT CONTROL PLAN FOR THE PROJECT
SHALL CALL FOR THE PLACEMENT OF POLYETHYLENE FENCE OR ITS
EQUIVALENT IN ACCORDANCE WITH STD & SPEC 3.01 OF THE
VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK ALONG
THE RPA LIMITS PRIOR TO THE ISSUANCE OF A LAND DISTURBANCE
PERMIT.
8. BUILDING ENVELOPES AS SHOWN ON THE TENTATIVE PLAN
ALONG WITH ANY OTHER DIRECTED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT SHALL BE PLACED ON THE
CONSTRUCTION PLANS AND SUBDIVISION PLAT.
9. THE FLOODPLAIN AS SHOWN ON THE APPROVED
CONSTRUCTION PLANS AND THE RECORDED SUBDIVISION PLAT SHALL
BE THE RESULT OF HYDROLOGIC AND HYDRAULIC ENGINEERING
METHODS AND ASSUMPTIONS WHICH ARE APPROVED BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT.
10. THE ACHIEVEMENT OF ADEQUATE SURFACE DRAINAGE ON LOTS
WILL BE THE RESPONSIBILITY OF THE SUBDIVIDER. THE SALE OF
LOTS DOES NOT ABSOLVE THE SUBDIVIDER FROM THIS
RESPONSIBILITY PRIOR TO STATE ACCEPTANCE OF THE STREETS AND
FOR A PERIOD OF ONE YEAR AFTER THE STREETS ARE TAKEN INTO TH
STATE SYSTEM.
11. PRIOR TO RECORDATION, THE ENVIRONMENTAL ENGINEERING
DEPARTMENT MUST HAVE RECEIVED NOTIFICATION FROM VDOT
THAT IMPROVEMENTS TO THE STATE ROAD(S) INTO WHICH THIS
PROJECT INTERSECTS AND WHICH, HAVE BEEN AUTHORIZED BY AN
ISSUED LAND USE PERMIT, HAVE BEEN SATISFACTORILY
COMPLETED.
12. THE POINTS OF PERENNIAL FLOW ALONG WITH THEIR GPS
COORDINATE VALUES WILL BE SHOWN ON THE CONSTRUCTION PLAN
AND RECORD PLAT.
(PLEASE PLACE ON DEVELOPER LETTERHEAD)
(DATE)
KIRKLAND A. TURNER, DIRECTOR
CHESTERFIELD COUNTY PLANNING DEPARTMENT
P. O. BOX 40
CHESTERFIELD, VIRGINIA 23832
RE: ENTRANCE EMBELLISHMENTS (____________ TENTATIVE)
DEAR MR. TURNER:
AS DEVELOPER OF THE PROPOSED __________________
SUBDIVISION, I AM AWARE THAT THE FOLLOWING NOTE IS NOW
REQUIRED NOT ONLY ON TENTATIVES BUT ALSO ON RECORD PLATS.
"NO STRUCTURE EMBELLISHMENTS WILL BE ALLOWED ON VDOT
RIGHT-OF-WAY WITHOUT THE COMMITMENT OF, OR THE ISSUANCE OF,
A VDOT LAND USE PERMIT. WITHIN THE 10' CLEAR ZONE
(MEASURED FROM THE EDGE OF THE ROADWAY'S PAVEMENT OUT
10'), NO STRUCTURE EMBELLISHMENT WILL BE PERMITTED THAT IS
CLOSER THAN 3' FROM THE EDGE OF PAVEMENT OF THE PUBLIC
STREET OR HIGHER THAN 6" ABOVE THE SURFACE OF THE DRIVE."
I WILL DO ALL POSSIBLE TO PROVIDE THE CORRECT INFORMATION FO
BUILDERS OR CITIZENS CONSTRUCTING ENTRANCE EMBELLISHMENTS.
I AM ALSO AWARE THAT, PRIOR TO STATE ACCEPTANCE OF THE
ROADS, I AM RESPONSIBLE FOR REMOVING EMBELLISHMENTS THAT
DO NOT MEET STATE STANDARDS.
SINCERELY,
DEVELOPER NAME (PRINTED)
DEVELOPER SIGNATURE (DATE
*******************************************
PLAN NAME: DEBONAIR ACRES
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING
REVIEWER/PHONE: L. D. PRITCHARD, JR. / 748-1028
PLAN NUMBER: 09TS0236
CONSULTANT: HIGHMARK ENGINEERING
PLANNER: RAY CASH
ORIGINAL PLAN DATE: DECEMBER 12, 008
LATEST SUBMISSION DATE: DECEMBER 12, 2008
UPDATED: MAY 6, 2009
REVIEW DATE: OCTOBER 26, 2010
SUBMITTAL NUMBER: 2
STATUS: REVISIONS REQUESTED
THE ENVIRONMENTAL ENGINEERING DEPARTMENT PRESENTS
THE FOLLOWING PRELIMINARY COMMENTS AND OBSERVATIONS
PERTAINING TO THE ABOVE REFERENCED TENTATIVE PLAT DATED
DECEMBER 12, 2008, RECEIVED BY THE PLANNING
DEPARTMENT ON DECEMBER 15, 2008 AND BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT ON DECEMBER 18,
2008.
WITH RESPECT TO ROAD NAMES, THE RRPDC STREET NAME
CLEARING HOUSE REQUEST SHEET WAS SUBMITTED WITHOUT FIRST
HAVING IT SUBMITTED TO RRPDC FOR THEIR APPROVAL. THE
SECTION OF THE CLEARING HOUSE REQUEST SHEET UNDER "RRPDC
USE ONLY" IS BLANK. PLEASE HAVE THE TWO SHEETS SENT TO
RRPDC FOR THEIR APPROVAL AND RE-SUBMIT TO THE
ENVIRONMENTAL ENGINEERING DEPARTMENT. WE ARE AWAITING
THIS SUBMITTAL.
A COPY OF THE DEBONAIR PROPERTY PERENNIAL STREAM
STUDY, PD269, HAS SHOWN THAT THE PERENNIALITY
DETERMINATION FOR THIS PROJECT HAS BEEN COMPLETED.
PLEASE PROVIDE A LETTER FROM THE RECOGNIZED WETLAND
EXPERT REGARDING THE ACCURACY OF THE WETLANDS DELINEATION
PORTRAYED ON THE TENTATIVE PLAT THAT IS THE BASIS FOR THE
RPA-LIMITS ESTABLISHMENT. SUGGESTED WORDING IS, "I HAVE
VIEWED THE TENTATIVE PLAT FOR DEBONAIR ACRES DATED
DECEMBER 12, 2008 BY HIGHMARK ENGINEERING AND FIND THAT
IT PORTRAYS AN ACCURATE REPRESENTATION OF MY FIELD
DELINEATION OF THE WETLANDS LOCATED ADJACENT TO THE PERENNIA
STREAMS. THE WRITTEN RESPONSE COMMENT TO THIS
CONDITION WAS "ATTACHED 5 PAGE LETTER" WHICH IS
PRESUMED
TO BE THE CORPS OF ENGINEERS PRELIMINARY JURISDICTIONAL
DETERMINATION DATED APRIL 2, 2009. THAT LETTER DOES NOT
TELL ME WHETHER OR NOT THE WETLANDS ARE ACCURATELY
PRESENTED ON THE TENTATIVE PLAT. PLEASE ADDRESS.
IN ORDER TO ENSURE THE ACCURACY OF THE RPA ESTABLISHMENT,
THE COORDINATE POINTS WHICH CAPTURE THE POINT OF PERENNIAL
FLOW MUST BE SHOWN ON THE TENTATIVE PLAT. IF THE WETLANDS
UPSTREAM OF THE POINT OF PERENNIALITY ARE CONFINED TO WITHIN
A BED AND BANK BECOMING "WATERS OF THE U.S.", THE LIMITS OF
THE RPA AS THEY EXTEND UPSTREAM FROM THE POINT OF
PERENNIALITY ARE ESTABLISHED BY A 100 FOOT RADIUS BUFFER OFF
OF THAT POINT OF PERENNIAL FLOW. IF FROM THAT POINT OF
PERENNIAL FLOW, WETLANDS EXTEND ON UPSTREAM THAT ARE
CONNECTED AND CONTIGUOUS, THE RPA WOULD EXTEND A
DISTANCE NO GREATER THAN 500' IN ACCORDANCE WITH THE
ENVIRONMENTAL ENGINEERING POLICY OF APRIL 30, 2008. ON
SHEET 4,IN THE OPEN SPACE BETWEEN LOTS 90 AND 91, THE
ORIGIN OF PERENNIAL FLOW COORDINATES ARE INCORRECT.
THESE COORDINATES APPEAR TO BE A DUPLICATION OF THE
COORDINATE VALUES ON SHEET 3, LOT 165, WHICH ARE CORRECT
AS ARE THE COORDINATE VALUES ON SHEET 2, BEHIND LOT 223.
PLEASE ADDRESS.
THE 500 FOOT DISTANCE FROM THE ORIGIN OF PERENNIAL FLOW
IS NOT A REQUIREMENT, ONLY A MAXIMUM DISTANCE.
THEREFORE, THE RPA IN LOTS 186 AND 187 ON SHEET 3 DOES
NOT NEED TO BE EXTENDED THE FULL 500 FEET, BUT ONLY 100
FEET BEYOND THE WETLAND LIMITS IN 186. PLEASE ADDRESS.
PLEASE CLARIFY ON SHEET 3 WHY THE RPA TERMINATES AT THE
REAR OF LOTS 42 AND 66. ON SHEET 4, PLEASE CLARIFY WHY
THE RPA TERMINATES AT THE REAR OF LOT 158.
PLEASE PROVIDE, AT STRATEGIC POINTS ON ALL SHEETS, THE
DOUBLE SIDED ARROW WHICH SCALES OUT AT 100 FEET PLACED
BETWEEN THE LIMITS OF THE RPA AND THE ENVIRONMENTAL
RESOURCE AND ANNOTATE IT AS "100 FOOT RPA BUFFER."
WITH RESPECT TO ROAD NAMES, THE REVISION IN THE ROAD
AND LOT LAYOUT HAS CREATED A FEW ISSUES THAT WERE NOT ON
THE FIRST PLAN. THE PACE SETTER DRIVE/TERRACE/COURT
COMBO IS NOT CONSISTENT WITH STANDARDS USED. ONE
SUGGESTED FIX WOULD BE TO EXTEND THE CLUBHOUSE TURN
LANE ALL THE WAY TO PACE SETTER TERRACE AND CHANGE THE
NAME OF PACE SETTER TERRACE TO PACE SETTER LANE. PLEASE
ADDRESS THE EARLY FOOT LANE DUPLICATION BY HAVING
EARLY FOOT LANE, WHICH PROVIDES FRONTAGE FOR LOTS 204
THROUGH 211, BE CALLED EARLY FOOT TERRACE.
THE RIGHT OF WAY STUB COMING OFF THE CUL-DE-SAC BULB
BETWEEN LOTS 1 AND 2 IS QUESTIONABLE. A CONCURRENCE
WITH THAT LAYOUT BY VDOT IS NEEDED. PLEASE ADDRESS.
THE QUALITY OF THE TOPOGRAPHY INFORMATION HAS
DETERIORATED CONSIDERABLY FROM THE ORIGINAL SUBMITTAL IN
DECEMBER, 2008.
PLEASE SHOW THE EXISTING TRACK AND INDICATE ITS INDICATED
DISPOSITION.
ON THE COVER SHEET, SINCE THE ENVIRONMENTAL
ENGINEERING RPA POLICY OF APRIL 30, 2008 IS NO LONGER IN
EFFECT, PLEASE DOCUMENT WHY THE 500 FOOT RPA LIMITATION
IS STILL APPLICABLE TO THIS PROJECT. "THE INITIAL SUBMITTAL
DATE OF THIS TENTATIVE PLAT (DECEMBER 12, 2008) PREDATES
THE SEPTEMBER 23, 2009 DATE BEYOND WHICH
ENVIRONMENTAL ENGINEERING DEPARTMENT POLICY NO
LONGER PERMITS THE 500 FOOT RPA LIMITATION BUT REQUIRES
ADHERENCE TO THE DCR GUIDANCE ADOPTED JUNE 18,
2007."
AN ASSESSMENT OF THE TOPOGRAPHY IN RELATION TO THE LOT
LAYOUT HAS REVEALED SEVERAL AREAS OF STORM WATER
CONCENTRATION WHICH ARE IN POTENTIAL CONFLICT WITH THE
DESIRE NOT TO HAVE STORM DRAINAGE PROBLEMS RELATED TO THE
DEVELOPMENT OF THE HOUSE AND LOT. THESE ARE ENGINEERING
ISSUES WHICH SHOULD BE ADDRESSED BY THE CONSTRUCTION
PLANS AND NOT LEFT TO THE INDIVIDUAL BUILDERS TO DEAL WITH.
THE PHYSICAL "LOW" OF THESE DRAINAGE CORRIDORS SHOULD BE
FIELD LOCATED AND APPROPRIATE ENGINEERING PROPOSALS WITH
RESPECT TO FILLING, GRADING, DRAINAGE STORM SEWERING AND
BUILDING ENVELOPE LOCATIONS SHOULD BE MADE A PART OF THE
CONSTRUCTION PLANS. THESE AREAS ARE AS FOLLOWS:
A. THE DRAINAGE CORRIDOR BETWEEN LOTS 261 AND 264.
B. THE DRAINAGE CORRIDOR BEGINNING IN LOT 199 DOWN TO
LOT 189.
C. THE DRAINAGE CORRIDOR BEGINNING IN LOT 54 DOWN
THROUGH LOT 47.
D. THE DRAINAGE CORRIDOR BEGINNING IN LOT 32, DOWN
THROUGH LOT 35.
TENTATIVE CONDITIONS COULD INCLUDE BUT NOT BE LIMITED TO THE
FOLLOWING:
1. PER SECTION 8-4 OF THE EROSION CONTROL ORDINANCE, PRIOR
TO THE ISSUANCE OF A LAND DISTURBANCE PERMIT, THE
ENVIRONMENTAL ENGINEERING DEPARTMENT SHALL REQUIRE
COPIES OF APPLICABLE CORRESPONDENCE FROM THE USACOE SO
THAT IT MAY BE DETERMINED THAT ALL WETLANDS PERMITS HAVE
BEEN RECEIVED.
2. ANY TIMBERING THAT IS TO OCCUR AS THE FIRST PHASE OF
INFRASTRUCTURE CONSTRUCTION WILL BE INCORPORATED INTO THE
PROJECT'S EROSION-AND-SEDIMENT CONTROL PLAN NARRATIVE AND
WILL NOT COMMENCE UNTIL THE ISSUANCE OF A LAND DISTURBANCE
PERMIT FOR SUBDIVISION CONSTRUCTION AND PROPER INSTALLATION
OF EROSION CONTROL MEASURES.
3. THE USACOE JURISDICTIONAL WETLANDS SHALL BE SHOWN
ON THE CONSTRUCTION PLANS AND SUBDIVISION PLAT
4. PRIOR TO CONSTRUCTION PLAN APPROVAL, THE APPLICANT WILL
PROVIDE THE ENVIRONMENTAL ENGINEERING DEPARTMENT
INFORMATION CONFIRMING THAT THERE WILL BE NO ENCROACHMENT
OF THE PRIMARY OR SECONDARY DRAIN FIELDS OR HOME
CONSTRUCTION INTO THE RPA. THIS WILL BE DOCUMENTED BY
THE INCLUSION OF A PLAN VIEW SHEET IN THE CONSTRUCTION PLANS
WHICH MUST ALSO BE APPROVED BY THE HEALTH DEPARTMENT.
5. THE AREAS OF STORM-WATER RUNOFF CONCENTRATION AS
DISCUSSED IN THE ENVIRONMENTAL ENGINEERING DEPARTMENT
TENTATIVE REPORT DATED OCTOBER 26, 2010 WILL BE FIELD
LOCATED AND SHOWN ON THE PLANS. THE CONSTRUCTION PLANS
SHALL DESIGNATE THE AFFECTED LOTS WITH AN NBP, AND AN
ENGINEERED STORM SEWER, FILLING, GRADING, AND DRAINAGE
PLAN SHALL BE INCLUDED IN THE CONSTRUCTION PLANS.
6. THE SUB-DIVIDER SHALL POST SIGNS DEMARKING THE LIMITS
OF THE RPA AREA SO BUILDERS AND HOMEOWNERS MAY BE
INFORMED AS TO THE LIMITATIONS IMPOSED ON THESE AREAS.
SPECIFIC PLANS FOR THE EXACT NUMBER AND PLACEMENT OF THE
SIGNS SHALL BE APPROVED BY THE ENVIRONMENTAL ENGINEERING
DEPARTMENT.
7. THE EROSION AND SEDIMENT CONTROL PLAN FOR THE PROJECT
SHALL CALL FOR THE PLACEMENT OF POLYETHYLENE FENCE OR ITS
EQUIVALENT IN ACCORDANCE WITH STD & SPEC 3.01 OF THE
VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK ALONG
THE RPA LIMITS PRIOR TO THE ISSUANCE OF A LAND DISTURBANCE
PERMIT.
8. BUILDING ENVELOPES AS SHOWN ON THE TENTATIVE PLAN
ALONG WITH ANY OTHER DIRECTED BY THE ENVIRONMENTAL
ENGINEERING DEPARTMENT SHALL BE PLACED ON THE
CONSTRUCTION PLANS AND SUBDIVISION PLAT.
9. THE FLOODPLAIN AS SHOWN ON THE APPROVED
CONSTRUCTION PLANS AND THE RECORDED SUBDIVISION PLAT SHALL
BE THE RESULT OF HYDROLOGIC AND HYDRAULIC ENGINEERING
METHODS AND ASSUMPTIONS WHICH ARE APPROVED BY THE
ENVIRONMENTAL ENGINEERING DEPARTMENT.
10. THE ACHIEVEMENT OF ADEQUATE SURFACE DRAINAGE ON LOTS
WILL BE THE RESPONSIBILITY OF THE SUBDIVIDER. THE SALE OF
LOTS DOES NOT ABSOLVE THE SUBDIVIDER FROM THIS
RESPONSIBILITY PRIOR TO STATE ACCEPTANCE OF THE STREETS AND
FOR A PERIOD OF ONE YEAR AFTER THE STREETS ARE TAKEN INTO TH
STATE SYSTEM.
11. PRIOR TO RECORDATION, THE ENVIRONMENTAL ENGINEERING
DEPARTMENT MUST HAVE RECEIVED NOTIFICATION FROM VDOT
THAT IMPROVEMENTS TO THE STATE ROAD(S) INTO WHICH THIS
PROJECT INTERSECTS AND WHICH, HAVE BEEN AUTHORIZED BY AN
ISSUED LAND USE PERMIT, HAVE BEEN SATISFACTORILY
COMPLETED.
12. THE POINTS OF PERENNIAL FLOW ALONG WITH THEIR GPS
COORDINATE VALUES WILL BE SHOWN ON THE CONSTRUCTION PLAN
AND RECORD PLAT.
**********************************