Thanksgiving Holiday Closings... MORE

Hover here for Site Tools
Subdivision Review Comments
All Subdivision Review Comments for Case # 07FC0052




For VDOT’s comments please contact Virginia Department of Transportation at (804) 674-2814 or send e-mail to Boris.Solomonov@VDOT.Virginia.gov

For Tentative Subdivision resubmittals:

1. Please note that submittal fees include the original submittal and two (2) additional reviews.

2. A letter of transmittal is required to accompany each submittal.

3. Please verify that Environmental Engineering, Fire, CDOT, VDOT, and Planning have reviewed the submittal before resubmitting. A resubmittal tendered, prior to receiving all the required departments’ review, will be counted as an additional submittal. Go to Case Selection Form or Go to Project List


 
CASE NO: 07FC0052 STATUS: APPROVED- ADMIN
PROJECT NAME: MAGNOLIA GREEN - LAST INTERNET UPDATE: 11/22/17
SUBMITTAL TYPE: FINAL CHECK
DEPARTMENT...REV..ROUTED..RESPONSE..STATUS....DATE...RVW..PHONE
ASSESSOR----: 00 12/05/06 12/27/06 COMPLETE 12/07/06 LAH 748-1945
ENVIR.ENGR.-: 00 12/05/06 12/27/06 COMPLETE 02/05/07 LPD 748-1036
HOUSE NUMBER: 00 12/05/06 12/27/06 ******** ********
MAPPING/GIS-: 00 12/05/06 12/27/06 COMPLETE 12/21/06 NCP 751-4319
PLANNING----: 00 12/05/06 12/27/06 COMPLETE 01/29/07 RHM 796-7193
TRANSPORT.--: 00 12/05/06 12/27/06 COMPLETE 12/18/06 LWC 768-7386
UTIL.PLAN.--: 00 12/05/06 12/27/06 COMPLETE 12/06/06 TVM 751-4435
UTILITIES---: 00 12/05/06 12/27/06 ******** ********
UTIL.R.O.W.-: 00 12/05/06 12/27/06 COMPLETE 12/22/06 KIP 748-1376
VDOT--------: 00 12/05/06 12/27/06 ******** ********
REVIEW DEPARTMENT : UTILITIES RIGHT OF WAY
REVIEWER : KIMBERLY PULLEY / 748-1376
NAME OF PLAN & NO. : MAGNOLIA GREEN SEC B/07FC0052
ADDRESS :
RECEIVED DATE : 12/6/06
PLAN/REVISION DATED: N/A
REVIEW DATE : 12/22/06
STATUS :
1. SIGN SURVEYORS SEAL
2. FILL IN DATE
3. FILL IN DB & PG FOR NOTE # 11 ON SHEET 1
4. FILL IN PG & PG FOR MAGNOLIA GREEN - SEC A ON SHEET 2 & 3
5. FILL IN DB & PG FOR EXISTING EASEMENTS
REVIEW DEPARTMENT: UTILITIES
REVIEWER / PHONE # : TERRY MAPLES 751-4435
PLAN NAME: MAGNOLIA GREEN SEC. B
PLAN NUMBER: 07FC0052
ORIGINAL PLAN DATE: 10/31/06
REVIEW DATE: 12/06/06
LATEST SUBMISSION DATE:
SUBMITTAL NUMBER:
STATUS:
NO ADDITIONAL PUBLIC WATER AND SEWER EASEMENTS
ARE REQUIRED FOR THE ABOVE REFERENCED PROJECT.
REVIEW DEPARTMENT: TRANSPORTATION
REVIEWER/PHONE #: LOUIS CORDE / 768-7386
PLAN NAME: MAGNOLIA BREEN SECTION 2
PLAN NUMBER: 07FC0052
ORIGINAL PLAN DATE: 10/31/06
REVIEW DATE: 12/18/06 12/05/06
LATEST SUBMISSION DATE: 11/30/06
SUBMITTAL NUMBER: 1
STATUS: NOT APPROVED - SEE COMMENTS
THE TRANSPORTATION DEPARTMENT HAS THE FOLLOWING COMMENTS:
THIS PLAT CANNOT BE APPROVED UNTIL ALL REQUIRED RIGHT-OF-WAY
DEDICATIONS, STIPULATED WITH THE APPROVED TRANSPORTATION
PHASING PLAN, ARE RECORDED. (T)
SHEETS 4, 5 & 6 NEED TO SHOW BUILDING ENVELOPE AREAS TO
INSURE THAT ALL BUILDINGS ON BLACK ALDER DRIVE ARE SET BACK
AT LEAST 130 FEET FROM THE CENTERLINE OF WEEPING WILLOW
DRIVE. (T)
REVIEW DEPARTMENT: TRANSPORTATION
REVIEWER/PHONE #: LOUIS CORDE / 768-7386
PLAN NAME: MAGNOLIA BREEN SECTION 2
PLAN NUMBER: 07FC0052
ORIGINAL PLAN DATE: 10/31/06
REVIEW DATE: 09/21/07
LATEST SUBMISSION DATE: 11/30/06
SUBMITTAL NUMBER: 1
STATUS: APPROVED
THE TRANSPORTATION DEPARTMENT HAS NO COMMENT.
REVIEW DEPARTMENT : PLANNING
REVIEWER / PHONE # : RUSS MILLS / 796-7193
PLAN NAME : MAGNOLIA GREEN SECTION B
PLAN NUMBER : 07FC0052
ORIGINAL PLAN DATE : 10/31/2006
REVIEW DATE : 01/29/2007
LATEST SUBMISSION DATE : 11/30/2006
SUBMITTAL NUMBER : 1
STATUS : REVISIONS REQUESTED
1. INSERT SUBDIVISION ID # 015-0426-02
2. CORRECT ALL DATES
3. UNDER NOTES, STATE THE SPECIFIC RESIDENTIAL USE
4. BEFORE RECORD PLAT SUBMITTAL, PLEASE FLAG ALL BUFFERS
AND CALL RUSS MILLS AT 796-7193 FOR INSPECTION
5. FILL IN THE DB AND PG FOR RECORDED HOA DOCUMENTS
6. REMOVE NOTE 19
7. FILL IN DB AND PG ON ALL LABELED EASEMENTS
8. PROVIDE SETBACK LINES OFF OF BUFFERS WHERE BUFFER RUNS
ONTO THE ACTUAL LOT AND GIVE DIMENSIONS (LOT 1, 43, 44, 45,
46, 59, 60)
9. SIGN THE SEALS
==========================================================
==========================================================
REVIEW DEPARTMENT: ENVIRONMENTAL ENGINEERING / GIS
REVIEWER : NANCY PARKER 751-4319
NAME OF PLAN : MAGNOLIA GREEN SEC 2
PLAN CASE NO. : 07FC0052
ADDRESS :
LATEST PLAN DATE : 10/31/06
RECEIVED DATE : 12/5/06
SUBMITTAL NUMBER : 1
REVIEW DATE : 12/21/06
RECOMMENDATION : APPROVED WITH COMMENT
PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONCERNING
THE COMMENTS BELOW.
1. THE PARENT PARCEL ID NUMBER WILL CHANGE FOLLOWING THE
RECORDATION OF SECTION 1. PLEASE NOTE THE NEW PARCEL
ID NUMBER AND SHOW IT IN NOTE #5 ON THIS PLAT.
REVIEWER / PHONE #: LARRY DOUBERLY (804) 748-1036
PLAN NUMBER: 07FC0052
ORIGINAL PLAN DATE: 10/31/06
REVIEW DATE: FEBRUARY 5, 2007
LATEST SUBMISSION DATE:
SUBMITTAL NUMBER:
STATUS:
EE FILE 202705
I. ADDITIONS OR DELETIONS TO PLAT.
THE SUBDIVISION MUST COMPLY WITH THE PROVISIONS OF
THE CHESAPEAKE BAY ORDINANCE.
PROVIDE NOTE TO INDICATE THE METHOD OF CBPA
COMPLIANCE, THE TYPE OF FACILITY UTILIZED, AS WELL AS
THE RECORDATION INFORMATION.
PROVIDE NOTE WITH ASTERISK ON EACH LOT BETWEEN RPA
LIMITS AND CREEK."CONSERVATION AREA TO REMAIN IN ITS
NATURAL STATE, NO STRUCTURE TO BE LOCATED WITHIN
THE RPA."
PLACE REFERENCE SYMBOL ON EACH LOT WITH WETLANDS.
GRAPHICALLY SHOW THE 25' SETBACK ADJACENT TO ALL
WETLAND, FLOODPLAIN AND BACKWATER LIMITS.
PROVIDE NOTE WITH CORRESPONDING REFERENCE SYMBOL
FOR WETLANDS AS SHOWN "U.S. ARMY CORPS OF ENGINEERS
OR COMMONWEALTH OF VIRGINIA JURISDICTIONAL
WETLANDS NOT TO BE DISTURBED WITHOUT WRITTEN
PERMISSION FROM THE CORPS OR VIRGINIA DEPARTMENT OF
ENVIRONMENTAL QUALITY"
PROVIDE A NOTE FOR NO MASONRY EMBELLISHED
ENTRANCE STRUCTURES. THE NOTE SHOULD REFLECT 3'
FROM THE EDGE OF PAVEMENT RATHER THAN 2' FEET.
ALL EASEMENTS, STRIPS, AND RIGHTS OF WAY MUST BE
CHECKED AND APPROVED BY THE RIGHT OF WAY
DEPARTMENT TO VERIFY THEY ARE UNRESTRICTED BY ANY
PREVIOUS AGREEMENTS OR EASEMENTS, PRIOR TO
RECORDATION.
PROVIDE DB. & PG. FOR ALL EXISTING OFFSITE EASEMENTS.
ALL EXISTING DOMINION VIRGINIA POWER, C&P TELEPHONE,
AND/OR COMMONWEALTH/COLONIAL GAS PIPELINE
EASEMENTS/RIGHTS_OF_WAY MUST BE QUIT CLAIMED PRIOR
TO PLAT RECORDATION DUE TO VDOT RIGHT_OF_WAY
CONFLUENCE.
THE VIRGINIA STATE REGISTRATION BOARD CERTIFICATION
STAMP MUST APPEAR ON THE LINENS/ MYLARS AND BE
SIGNED.
COMPLETE SUBDIVISION CERTIFICATE.
PROVIDE SUBDIVISION IDENTIFICATION NUMBER.
COMPLETE SURVEYOR'S CERTIFICATE.
COMPLETE SOURCE OF TITLE.
THE COUNTY RESERVES THE RIGHT TO MAKE ADDITIONAL
REQUIREMENTS FOR ON_SITE AND OFF_SITE EASEMENTS, AS
DEEMED NECESSARY BY AN ON_SITE REVIEW OF THE ROAD
AND DRAINAGE PLANS.
II. APPROVALS.
RELEASE FROM GIS TO INCLUDE HOUSE NUMBERING.
RELEASE FROM RIGHT OF WAY DEPARTMENT.
RELEASE FROM ASSESSOR'S OFFICE.
IF PRIVATE ROAD NAME SIGNS ARE TO UTILIZED, PROVIDE A
DETAIL OF THE PROPOSED DESIGN TO BE REVIEWED AND
APPROVED.
PROVIDE VDOT APPROVAL OF GEOTECHNICAL
CONFIRMATION OF TRENCH AND FILL COMPACTION, FOR
ROADWAYS.
PROVIDE COMMITMENT LETTER FROM THE APPROPRIATE
PIPELINE ENTITIES FOR QUIT CLAIM OF THE EASEMENT AT
THE TIME OF STATE ACCEPTANCE.
III. MONETARY REQUIREMENTS.
PER ORDINANCE SEC.19_233, AMENDED MARCH 14, 2001,
PROVIDE $100.00 PER LOT BMP MAINTENANCE FEE IN AN
AMOUNT OF $__6,700.00_________________, PAYABLE TO THE
TREASURER OF CHESTERFIELD COUNTY.
PER ORDINANCE SEC.19_233, AMENDED MARCH 14, 2001,
PROVIDE UPPER SWIFT CREEK REGIONAL BMP
CONSTRUCTION FEE IN AN AMOUNT TO BE DETERMINED
UPON SUBMISSION AND RECIEPT OF THE LINEN AND MYLARS
TO ENGINEERING. THIS ALLOWS FOR ACCURATE
CALCULATIONS UTILIZING THE CURRENT "ENR" COST INDEX,
PAYABLE TO THE TREASURER OF CHESTERFIELD COUNTY.
PROVIDE STREET SIGN FEE ( $150.00 PER INTERSECTION) IN
THE AMOUNT OF $___1,050.00__, PAYABLE TO THE TREASURER
OF CHESTERFIELD COUNTY.
PROVIDE STREETLIGHT FEES TO INCLUDE THE $50.00
PROGRAM ADMINISTRATION FEE, PAYABLE TO THE
TREASURER OF CHESTERFIELD COUNTY.
AN ITEMIZED COST ESTIMATE OF THE PROPOSED UTILITIES,
DRAINAGE AND ROAD IMPROVEMENTS, PLUS SNOW
REMOVAL, SHOWING HOW THE TOTAL ON THE SUBDIVISION
BOND WAS DERIVED, MUST BE APPROVED PRIOR TO SURETY
SUBMITTAL.
COPY OF THE VALID CONTRACT THAT THE DEVELOPER HAS
FOR SNOW REMOVAL.
A 100% SURETY FOR THE REMAINING IMPROVEMENTS AND
10% FOR COMPLETED WORK, MUST BE DULY EXECUTED
PRIOR TO RECORDATION.
IV. EROSION CONTROL
ALL EROSION CONTROL ORDINANCE REQUIREMENTS,
INCLUDING SATISFACTORY IMPLEMENTATION AND/OR
MAINTENANCE OF EROSION CONTROL MEASURES IN THE
FIELD, SHALL BE FULFILLED PRIOR TO RECORDATION.
************************************************************
REVIEW DEPARTMENT :ASSESSORS
REVIEWER / PHONE # :LINDA HUMPHRIES/748-1945
PLAN NAME :MAGNOLIA GREEN SECTION B
PLAN NUMBER :07FC0052
ORIGINAL PLAN DATE :10/31/06
REVIEW DATE :12/7/06
LATEST SUBMISSION DATE :
SUBMITTAL NUMBER :1
STATUS :NO COMMENTS

Go to Case Selection Form or Go to Project List