Addition
 
FacebookTwitterYouTubeMedia CenterRSS
Contact Us

Building Inspection Director
Richard C. Witt

Phone/Fax
(804) 748-1057
(804) 751-4713 Fax

Get complete contact info 

Email us with questions about
Permits and Fees
Residential code requirements
Commercial code requirements
Residential inspection requirements
Commercial inspection requirements 


Hours
Office - M-F, 8:30 a.m. - 5 p.m.
Inspectors M-F, 8 a.m. - 4:30 p.m.

Mailing Address
Chesterfield County Department of Building Inspection
P.O. Box 40
Chesterfield, VA 23832-0040

Street Address
9800 Government Center Parkway
Chesterfield, VA 23832
Map this 

 
Construction Project Types
Addition

For additional information, download the Requirements for building a house or addition pamphlet.

Permits required:  

  1. Building permit
  2. Auxiliary permits: One or more of the permit types listed below depending on the scope of work being performed:
    • Electrical permit
    • Plumbing permit
    • Gas permit
    • Mechanical permit
     

Application Submittal Requirements: 

  1. One (1) copy of Client Registration Form – if the permit is being applied for by a contractor who has never performed work in Chesterfield County before.
  2. One (1) copy of the Residential Building Permit Application 
  3. One (1) copy of the plot plan showing setbacks from existing and proposed improvements. Acceptable plot plans contain the following:
    1. Entire property, showing all property line dimensions
    2. Existing dwelling, any other existing structures and location of proposed structure (all dimensions of proposed structure clearly indicated). For proposed accessory structures, indicate the overall height.
    3. Setbacks from the closest point of the proposed structure to property lines in each direction. Label the measurements from each property line to the closest point on the structure. Be as exact as possible and label the name of road clearly.
    4. All buffers, easements or floodplains located on your property (no structure may be located in these areas)
     
  4. Two (2) copies of the construction plans – One set will be returned to the applicant with the issued permit. (For more detail on exactly what the construction plans require, see Construction Plan Requirements listed below.)
  5. Two (2) copies of the engineered soil reports – Required to be prepared by a soil scientist or geotechnical engineer. A soils report is required for construction of any potentially habitable space (i.e. living space) where the property is deemed to be in the Triassic Basin, that area of the county with an increased potential of “shrink-swell” soil. For more information see the Requirements for Soil Reports and Footings. 
  6. One (1) copy of the Residential Plans Review Delivery form - Indicates whether you would like the permit and forms mailed to you or held for three days at the Building Inspection office for you to pick up
  7. Payment of permit and other related fees – Residential Fee Schedule
    Cash, checks, MasterCard, Visa, Discover and American Express cards are accepted.

Construction Plan Requirements: Minimum of two copies of plans 

  1. Footing and foundation plan
  2. Basement plan
  3. First floor and first floor framing plan
  4. Second floor and second floor framing plan
  5. Attic and attic floor framing plan
  6. Roof and roof framing plan
  7. Elevations
  8. Structural cross section(s)

Plan Detail Requirements: 

  1. General Requirements for all Construction Drawings:
    1. Numbered – Every sheet of the plans numbered
    2. Scale – Structural plans drawn to architectural scale, typically 1/4”, 3/16” or 1/8”
    3. Legible - Neat and legible; void of handwritten notes
    4. Orientation – All drawings in the same orientation on the sheets
    5. Non-structural details - Do not submit mechanical, electrical or plumbing (MEP) drawings. Plan reviewers do not review these for residential plans; the field inspectors check for those issues. Do not submit cabinetry, stair, or non-structural details; they are not reviewed.
     
  2. Plan Views - Footing and Foundation, Basement, First Floor, Second Floor, Attic, Roof, and Framing Plans - Show the following details:
    1. Perimeter and interior dimensions
    2. Room names on each floor plan
    3. Size and location of all doors and windows
    4. All interior load-bearing walls identified
    5. All beams, including garage door headers, identified. All beams carrying more than 4000lbs – identify column on each end
    6. Size and direction of all floor joists and ceiling joists
      For I-joists or open-web joists, provide manufacturer’s layout plan. Identification on plans similar to:
      Nominal lumber: 2x8 SYP @ 16” o.c.
      I-joists: Truss Joist, Series 230, 11-7/8”, 16” o.c.
    7. Braced wall lines and the accompanying braced wall panel method(s) with calculation(s) clearly listed on each floor plan
    8. Full height, two-story walls (i.e. walls over 12 feet tall) engineered by a registered design professional
    9. Attic plan for all attics accessed by a permanent stair.
    10. Any space intended for “future” use marked accordingly
    11. Each rafter or truss individually drawn to show bearing; all overbuilt roofs identified.
      • For structures with truss roofs – provide truss layout and individual truss detail sheets. Truss detail sheets do not need to be individually sealed for plan review, but must be sealed by a registered design professional at the time of inspection.
       
     
  3. Sections – Include the following:
    1. At least one “through-structure” section, cut from the front to the rear of the structure, in a location that will show any non-standard section, such as a two-story family room or a room with a vaulted ceiling
    2. If there are multiple complicated spaces - separate sections to show all of the structure
    3. Section cut lines (arrows) referenced on the plan views
     
  4. Elevations – Include the following:
    1. Two elevations: from the front and side, showing exterior finishes
    2. If it has a basement - elevations showing approximate grade changes, doors and windows
     

Return to Obtaining a Permit/Design Criteria – Residential 

Related Content

Florida Room